Search for hidden-photon cold dark matter using a K-band cryogenic receiver
Abstract: We search for hidden-photon cold dark matter (HP-CDM) using a spectroscopic system in a K-band frequency range. Our system comprises a planar metal plate and cryogenic receiver. This is the first time a cryogenic receiver has been used in the search for HP-CDM. Such use helps reduce thermal noise. We recorded data for 9.3 hours using an effective aperture area of 14.8 cm$^2$. No signal was found i… ▽ More
Submitted 8 September, 2020; v1 submitted 4 June, 2020; originally announced June 2020.
Comments: 14 pages, 7 figures
Journal ref: JCAP 09 (2020) 012
-
arXiv:1601.06349 [pdf, ps, other]
Observation of gamma ray bursts at ground level under the thunderclouds
Abstract: We observed three $γ$-ray bursts related to thunderclouds in winter using the prototype of anti-neutrino detector PANDA made of 360-kg plastic scintillator deployed at Ohi Power Station at the coastal area of the Japan Sea. The maximum rate of the events which deposited the energy higher than $3\,$MeV was $(5.5 \pm 0.1) \times 10^2 {\rm /s}$. Monte Carlo simulation showed that electrons with app… ▽ More
Submitted 12 May, 2016; v1 submitted 24 January, 2016; originally announced January 2016.
Comments: 16 pages, 7 figures; Accepted for publication in Physics Letters B; Figure 5 added, some minor changes in the text
Journal ref: Physics Letters B, 758 (2016), pp. 286-291
-
Hidden photon CDM search at Tokyo
Abstract: We report on a search for hidden photon cold dark matter (HP CDM) using a novel technique with a dish antenna. We constructed two independent apparatus: one is aiming at the detection of the HP with a mass of $\sim\,\rm{eV}$ which employs optical instruments, and the other is for a mass of $\sim5\times10^{-5}\, \rm{eV}$ utilizing a commercially available parabolic antenna facing on a plane reflect… ▽ More
Submitted 2 September, 2015; originally announced September 2015.
Comments: Contributed to the 11th Patras Workshop on Axions, WIMPs and WISPs, Zaragoza, June 22 to 26, 2015
-
Experimental Search for Hidden Photon CDM in the eV mass range with a Dish Antenna
Abstract: A search for hidden photon cold dark matter (HP CDM) using a new technique with a dish antenna is reported. From the result of the measurement, we found no evidence for the existence of HP CDM and set an upper limit on the photon-HP mixing parameter $χ$ of $\sim 6\times 10^{-12}$ for the hidden photon mass $m_γ= 3.1 \pm 1.2$ eV.
Submitted 1 April, 2015; originally announced April 2015.
Comments: 10 pages, 5 figures. To be submitted to JCAP
-
arXiv:1404.7309 [pdf, ps, other]
Reactor antineutrino monitoring with a plastic scintillator array as a new safeguards method
Abstract: We developed a segmented reactor-antineutrino detector made of plastic scintillators for application as a tool in nuclear safeguards inspection and performed mostly unmanned field operations at a commercial power plant reactor. At a position outside the reactor building, we measured the difference in reactor antineutrino flux above the ground when the reactor was active and inactive.
Submitted 23 May, 2014; v1 submitted 29 April, 2014; originally announced April 2014.
Comments: 25 pages, 9 figures; Typos in Figure 6 corrected
Journal ref: Nuclear Instruments and Methods in Physics Research Section A 757 (2014) 33-39
-
arXiv:1312.7245 [pdf, ps, other]
Search for Hidden photons with Sumico
Abstract: We searched for solar hidden photons in the visible photon energy range using a hidden photon detector add-on attached to Sumico. It consists of a parabolic mirror of dia. 0.5m and f=1m installed in a vacuum chamber, and a low noise photomultiplier tube at the focal point. No evidence for the existence of hidden photons was found in the latest measurement giving a new limit on the photon-hidden ph… ▽ More
Submitted 27 December, 2013; originally announced December 2013.
Comments: 6 pages. Contributed to the 9th Patras Workshop on Axions, WIMPs and WISPs, Mainz, June 24-28, 2013
-
arXiv:1302.1000 [pdf, ps, other]
Experimental search for solar hidden photons in the eV energy range using kinetic mixing with photons
Abstract: We have searched for solar hidden photons in the eV energy range using a dedicated hidden photon detector. The detector consisted of a parabolic mirror with a diameter of 500mm and a focal length of 1007mm installed in a vacuum chamber, and a photomultiplier tube at its focal point. The detector was attached to the Tokyo axion helioscope, Sumico which has a mechanism to track the sun. From the res… ▽ More
Submitted 18 June, 2013; v1 submitted 5 February, 2013; originally announced February 2013.
Comments: 11 pages, 4 figures. To be submitted to JCAP. Added fig.2. Added references to some recent theoretical developments. Added results of new references to the exclusion plot(fig.5). Our results remain unchanged
Report number: RESCEU-18/13
Journal ref: JCAP07(2013)013
-
arXiv:1206.6566 [pdf, ps, other]
A mobile antineutrino detector with plastic scintillators
Abstract: We propose a new type segmented antineutrino detector made of plastic scintillators for the nuclear safeguard application. A small prototype was built and tested to measure background events. A satisfactory unmanned field operation of the detector system was demonstrated. Besides, a detailed Monte Carlo simulation code was developed to estimate the antineutrino detection efficiency of the detector… ▽ More
Submitted 28 June, 2012; originally announced June 2012.
Comments: 23 pages, 11 figures; accepted for publication in Nuclear Instruments and Methods in Physics Research A
Journal ref: Nucl.Instrum.Meth.A690:41-47,2012
-
arXiv:1010.5902 [pdf, ps, other]
Development of a Compact Resonance Ionization Mass Spectrometer for Trace Element Analysis of Potassium
Abstract: A compact resonance ionization mass spectrometer is developed using two laser diodes and a quadrupole mass spectrometer to perform trace element analysis of potassium. With the help of a narrow linewidth of the laser diode, the isotope shifts of $^{40}{\rm K}$ and $^{41}{\rm K}$ of the 405 nm line with respect to $^{39}{\rm K}$, corresponding to the transition of $4\,^2$S$_{1/2}\rightarrow$… ▽ More
Submitted 26 November, 2010; v1 submitted 28 October, 2010; originally announced October 2010.
Comments: 9 pages, 4 figures
-
arXiv:1007.4750 [pdf, ps, other]
Pulse-Shape Discrimination of CaF2(Eu)
Abstract: We measured the decay time of the scintillation pulses produced by electron and nuclear recoils in CaF2(Eu) by a new fitting method. In the recoil energy region 5-30 keVee, we found differences of the decay time between electron and nuclear recoil events. In the recoil energy region above 20 keVee, we found that the decay time is independent of the recoil energy.
Submitted 28 July, 2010; v1 submitted 27 July, 2010; originally announced July 2010.
Comments: 10 pages, 4 figures
Journal ref: Nucl.Instrum.Meth.A622:588-591,2010
-
arXiv:1004.1308 [pdf, ps, other]
Tokyo Axion Helioscope
Abstract: The idea of a magnetic axion helioscope was first proposed by Pierre Sikivie in 1983. Tokyo axion helioscope was built exploiting its detection principle with a dedicated cryogen-free superconducting magnet and PIN photodiodes for x-ray detectors. Solar axions, if exist, would be converted into x-ray photons in the magnetic field. Conversion is coherently enhanced even for massive axions by fillin… ▽ More
Submitted 8 April, 2010; originally announced April 2010.
Comments: 5 pages, 3 figures, AXIONS 2010
Report number: RESCEU-38/10
-
arXiv:1002.0468 [pdf, ps, other]
Tokyo axion helioscope experiment
Abstract: A search for solar axions has been performed using an axion helioscope which is equipped with a 2.3m x 4T superconducting magnet, a gas container to hold dispersion-matching gas, PIN-photodiode X-ray detectors, and a telescope mount mechanism to track the sun. In the past measurements, axion mass up to 0.27eV have been scanned. It has been upgraded to handle dispersion-matching gas (He-4) of hig… ▽ More
Submitted 2 February, 2010; originally announced February 2010.
Comments: 5 pages, 4 figures. Identification of dark matter 2008 (idm2008), August 18-22, 2008, Stockholm, Sweden
Report number: RESCEU-27/10
Journal ref: PoS(idm2008)067
-
arXiv:0808.4020 [pdf, ps, other]
Trace Element Analysis of Potassium by Resonance Ionization Mass Spectrometry
Abstract: A simple resonance ionization mass spectrometer is built with a Quadrupole Mass Spectrometer (QMS) and two laser diodes aiming at trace analysis of potassium. The overall detection efficiency is estimated comparing the yields of resonance ionization and electron-impact ionization in the same QMS. A clear discrimination of $^{39}\rm K$, $^{40}\rm K$ and $^{41}\rm K$ is demonstrated with a help of… ▽ More
Submitted 8 December, 2008; v1 submitted 29 August, 2008; originally announced August 2008.
Comments: 14 pages, 9 figures, submitted to JJAP
Report number: RESCEU-56/08
-
Measurement of the thickness of an insensitive surface layer of a PIN photodiode
Abstract: We measured the thickness of an insensitive surface layer of a PIN photodiode, Hamamatsu S3590-06, used in the Tokyo Axion Helioscope. We made alpha-particles impinge on the PIN photodiode in various incidence angles and measured the pulse height to estimate the thickness of the insensitive surface layer. This measurement showed its thickness was $0.31 \pm 0.02 μm$ on the assumption that the ins… ▽ More
Submitted 23 August, 2005; v1 submitted 21 April, 2005; originally announced April 2005.
Comments: 7 pages, 7 figures
Journal ref: Nucl.Instrum.Meth. A557 (2006) 684-687