Alignment of the CLAS12 central hybrid tracker with a Kalman Filter
Authors:
S. J. Paul,
A. Peck,
M. Arratia,
Y. Gotra,
V. Ziegler,
R. De Vita,
F. Bossu,
M. Defurne,
H. Atac,
C. Ayerbe Gayoso,
L. Baashen,
N. A. Baltzell,
L. Barion,
M. Bashkanov,
M. Battaglieri,
I. Bedlinskiy,
B. Benkel,
F. Benmokhtar,
A. Bianconi,
L. Biondo,
A. S. Biselli,
M. Bondi,
S. Boiarinov,
K. Th. Brinkmann,
W. J. Briscoe
, et al. (109 additional authors not shown)
Abstract:
Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these factors apply to the CLAS12 CVT, which is a hybrid detector consisting of planar silicon sensors with non-parallel strips, and cylindrical micromegas sensors wit…
▽ More
Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these factors apply to the CLAS12 CVT, which is a hybrid detector consisting of planar silicon sensors with non-parallel strips, and cylindrical micromegas sensors with longitudinal and arc-shaped strips located within a 5~T superconducting solenoid. To align this detector, we used the Kalman Alignment Algorithm, which accounts for correlations between the alignment parameters without requiring the time-consuming inversion of large matrices. This is the first time that this algorithm has been adapted for use with hybrid technologies, non-parallel strips, and curved sensors. We present the results for the first alignment of the CLAS12 CVT using straight tracks from cosmic rays and from a target with the magnetic field turned off. After running this procedure, we achieved alignment at the level of 10~$μ$m, and the widths of the residual spectra were greatly reduced. These results attest to the flexibility of this algorithm and its applicability to future use in the CLAS12 CVT and other hybrid or curved trackers, such as those proposed for the future Electron-Ion Collider.
△ Less
Submitted 9 August, 2022;
originally announced August 2022.
Decoupling of a Neutron Interferometer from Temperature Gradients
Authors:
Parminder Saggu,
Taisiya Mineeva,
Muhammad Arif,
David Cory,
Robert Haun,
Ben Heacock,
Michael Huber,
Ke Li,
Joachim Nsofini,
Dusan Sarenac,
Chandra Shahi,
Vladimir Skavysh,
William Snow,
Samuel Werner,
Albert Young,
Dmitriy Pushin
Abstract:
Neutron interferometry enables precision measurements that are typically operated within elaborate, multi-layered facilities which provide substantial shielding from environmental noise. These facilities are necessary to maintain the coherence requirements in a perfect crystal neutron interferometer which is extremely sensitive to local environmental conditions such as temperature gradients across…
▽ More
Neutron interferometry enables precision measurements that are typically operated within elaborate, multi-layered facilities which provide substantial shielding from environmental noise. These facilities are necessary to maintain the coherence requirements in a perfect crystal neutron interferometer which is extremely sensitive to local environmental conditions such as temperature gradients across the interferometer, external vibrations, and acoustic waves. The ease of operation and breadth of applications of perfect crystal neutron interferometry would greatly benefit from a mode of operation which relaxes these stringent isolation requirements. Here, the INDEX Collaboration and National Institute of Standards and Technology demonstrates the functionality of a neutron interferometer in vacuum and characterize the use of a compact vacuum chamber enclosure as a means to isolate the interferometer from spatial temperature gradients and time-dependent temperature fluctuations. The vacuum chamber is found to have no depreciable effect on the performance of the interferometer (contrast) while improving system stability, thereby showing that it is feasible to replace large temperature isolation and control systems with a compact vacuum enclosure for perfect crystal neutron interferometry.
△ Less
Submitted 29 November, 2016;
originally announced November 2016.