Evidence for Charge Exchange Emission in Supernova Remnant N132D from XRISM/Resolve Observations
Authors:
Liyi Gu,
Hiroya Yamaguchi,
Adam Foster,
Satoru Katsuda,
Hiroyuki Uchida,
Makoto Sawada,
Frederick Scott Porter,
Brian J. Williams,
Robert Petre,
Aya Bamba,
Yukikatsu Terada,
Manan Agarwal,
Anne Decourchelle,
Matteo Guainazzi,
Richard Kelley,
Caroline Kilbourne,
Michael Loewenstein,
Hironori Matsumoto,
Eric D. Miller,
Yuken Ohshiro,
Paul Plucinsky,
Hiromasa Suzuki,
Makoto Tashiro,
Jacco Vink,
Yuichiro Ezoe
, et al. (2 additional authors not shown)
Abstract:
XRISM has delivered one of its first light observations on N132D, the X-ray brightest supernova remnant in the Large Magellanic Cloud. Utilizing 193 ks of high-resolution X-ray spectroscopy data, we conduct a comprehensive search for charge exchange emission. By incorporating a charge exchange model into our spectral analysis, we observe an improvement in the fits of two weak features at 2.41 keV…
▽ More
XRISM has delivered one of its first light observations on N132D, the X-ray brightest supernova remnant in the Large Magellanic Cloud. Utilizing 193 ks of high-resolution X-ray spectroscopy data, we conduct a comprehensive search for charge exchange emission. By incorporating a charge exchange model into our spectral analysis, we observe an improvement in the fits of two weak features at 2.41 keV and 2.63 keV. These features, with a combined significance of 99.6%, are consistent with transitions from highly ionized silicon ions in high Rydberg states, which are unique indicators of charge exchange. Our analysis constrains the charge exchange flux to no more than 4% of the total source flux within the 1.7-3.0 keV band, and places an upper limit on the charge exchange interaction velocity at 450 km/s. This result supports ongoing shock-cloud interactions within N132D and highlights the unique capabilities of XRISM to probe the complex physical processes at play.
△ Less
Submitted 4 April, 2025;
originally announced April 2025.
X-ray spectral performance of the Sony IMX290 CMOS sensor near Fano limit after a per-pixel gain calibration
Authors:
Benjamin Schneider,
Gregory Prigozhin,
Richard F. Foster,
Marshall W. Bautz,
Hope Fu,
Catherine E. Grant,
Sarah Heine,
Jill Juneau,
Beverly LaMarr,
Olivier Limousin,
Nathan Lourie,
Andrew Malonis,
Eric D. Miller
Abstract:
The advent of back-illuminated complementary metal-oxide-semiconductor (CMOS) sensors and their well-known advantages over charge-coupled devices (CCDs) make them an attractive technology for future X-ray missions. However, numerous challenges remain, including improving their depletion depth and identifying effective methods to calculate per-pixel gain conversion. We have tested a commercial Sony…
▽ More
The advent of back-illuminated complementary metal-oxide-semiconductor (CMOS) sensors and their well-known advantages over charge-coupled devices (CCDs) make them an attractive technology for future X-ray missions. However, numerous challenges remain, including improving their depletion depth and identifying effective methods to calculate per-pixel gain conversion. We have tested a commercial Sony IMX290LLR CMOS sensor under X-ray light using an $^{55}$Fe radioactive source and collected X-ray photons for $\sim$15 consecutive days under stable conditions at regulated temperatures of 21°C and 26°C. At each temperature, the data set contained enough X-ray photons to produce one spectrum per pixel consisting only of single-pixel events. We determined the gain dispersion of its 2.1 million pixels using the peak fitting and the Energy Calibration by Correlation (ECC) methods. We measured a gain dispersion of 0.4\% at both temperatures and demonstrated the advantage of the ECC method in the case of spectra with low statistics. The energy resolution at 5.9 keV after the per-pixel gain correction is improved by $\gtrsim$10 eV for single-pixel and all event spectra, with single-pixel event energy resolution reaching $123.6\pm 0.2$ eV, close to the Fano limit of silicon sensors at room temperature. Finally, our long data acquisition demonstrated the excellent stability of the detector over more than 30 days under a flux of $10^4$ photons per second.
△ Less
Submitted 9 September, 2024;
originally announced September 2024.