-
Active Eye Lens Dosimetry With Dosepix: Influence of Measurement Position and Lead Glass Shielding
Authors:
Leonie Ullmann,
Florian Beißer,
Rolf Behrens,
Stefan Funk,
Gerhard Hilgers,
Oliver Hupe,
Jürgen Roth,
Tom Tröltzsch,
Hayo Zutz,
Thilo Michel
Abstract:
In this work, the effect of the measurement position on measurements of $H_\text{p}(3)$ of a new active eye lens dosemeter prototype based on the Dosepix detector is examined. A comparison between measuring directly in front of the eye and measuring at the side of the head of an Alderson phantom showed no significant influence on the resulting $H_\text{p}(3)$ for different radiation qualities and…
▽ More
In this work, the effect of the measurement position on measurements of $H_\text{p}(3)$ of a new active eye lens dosemeter prototype based on the Dosepix detector is examined. A comparison between measuring directly in front of the eye and measuring at the side of the head of an Alderson phantom showed no significant influence on the resulting $H_\text{p}(3)$ for different radiation qualities and angles. In addition, to account for the absorption effect of radiation safety glasses, pieces of lead glass were attached to the front and side of the dosemeter. Corresponding effects and consequences for radiation protection measurements have been investigated by using a human like Alderson head phantom as well as thermoluminescent dosemeters (TLDs) and the active eye lens dosemeter prototype. For specific angles, the radiation was able to bypass the radiation safety glasses and lead glass pieces, leading to an increase in the measured $H_\text{p}(3)$. Compared to TLDs behind radiation safety glasses, measurements with the lead glass shielded prototype resulted in lower values for $H_\text{p}(3)$. Furthermore, the results did not reproduce previous findings where larger dose values were found for Dosepix behind lead glass pieces than for the TLDs behind radiation safety glasses. A possible reason might be that the dimensions of the lead glass pieces are not representative of the radiation safety glasses in front of the eye but, ultimately, it is not yet clear what the main reason for the deviation is. Therefore, it is advisable to test the same methodology in future investigations with other eyewear models and lead glass pieces to investigate whether similar behaviors occur.
△ Less
Submitted 9 May, 2025;
originally announced June 2025.
-
Future Circular Collider Feasibility Study Report: Volume 2, Accelerators, Technical Infrastructure and Safety
Authors:
M. Benedikt,
F. Zimmermann,
B. Auchmann,
W. Bartmann,
J. P. Burnet,
C. Carli,
A. Chancé,
P. Craievich,
M. Giovannozzi,
C. Grojean,
J. Gutleber,
K. Hanke,
A. Henriques,
P. Janot,
C. Lourenço,
M. Mangano,
T. Otto,
J. Poole,
S. Rajagopalan,
T. Raubenheimer,
E. Todesco,
L. Ulrici,
T. Watson,
G. Wilkinson,
A. Abada
, et al. (1439 additional authors not shown)
Abstract:
In response to the 2020 Update of the European Strategy for Particle Physics, the Future Circular Collider (FCC) Feasibility Study was launched as an international collaboration hosted by CERN. This report describes the FCC integrated programme, which consists of two stages: an electron-positron collider (FCC-ee) in the first phase, serving as a high-luminosity Higgs, top, and electroweak factory;…
▽ More
In response to the 2020 Update of the European Strategy for Particle Physics, the Future Circular Collider (FCC) Feasibility Study was launched as an international collaboration hosted by CERN. This report describes the FCC integrated programme, which consists of two stages: an electron-positron collider (FCC-ee) in the first phase, serving as a high-luminosity Higgs, top, and electroweak factory; followed by a proton-proton collider (FCC-hh) at the energy frontier in the second phase.
FCC-ee is designed to operate at four key centre-of-mass energies: the Z pole, the WW production threshold, the ZH production peak, and the top/anti-top production threshold - delivering the highest possible luminosities to four experiments. Over 15 years of operation, FCC-ee will produce more than 6 trillion Z bosons, 200 million WW pairs, nearly 3 million Higgs bosons, and 2 million top anti-top pairs. Precise energy calibration at the Z pole and WW threshold will be achieved through frequent resonant depolarisation of pilot bunches. The sequence of operation modes remains flexible.
FCC-hh will operate at a centre-of-mass energy of approximately 85 TeV - nearly an order of magnitude higher than the LHC - and is designed to deliver 5 to 10 times the integrated luminosity of the HL-LHC. Its mass reach for direct discovery extends to several tens of TeV. In addition to proton-proton collisions, FCC-hh is capable of supporting ion-ion, ion-proton, and lepton-hadron collision modes.
This second volume of the Feasibility Study Report presents the complete design of the FCC-ee collider, its operation and staging strategy, the full-energy booster and injector complex, required accelerator technologies, safety concepts, and technical infrastructure. It also includes the design of the FCC-hh hadron collider, development of high-field magnets, hadron injector options, and key technical systems for FCC-hh.
△ Less
Submitted 25 April, 2025;
originally announced May 2025.
-
Future Circular Collider Feasibility Study Report: Volume 3, Civil Engineering, Implementation and Sustainability
Authors:
M. Benedikt,
F. Zimmermann,
B. Auchmann,
W. Bartmann,
J. P. Burnet,
C. Carli,
A. Chancé,
P. Craievich,
M. Giovannozzi,
C. Grojean,
J. Gutleber,
K. Hanke,
A. Henriques,
P. Janot,
C. Lourenço,
M. Mangano,
T. Otto,
J. Poole,
S. Rajagopalan,
T. Raubenheimer,
E. Todesco,
L. Ulrici,
T. Watson,
G. Wilkinson,
P. Azzi
, et al. (1439 additional authors not shown)
Abstract:
Volume 3 of the FCC Feasibility Report presents studies related to civil engineering, the development of a project implementation scenario, and environmental and sustainability aspects. The report details the iterative improvements made to the civil engineering concepts since 2018, taking into account subsurface conditions, accelerator and experiment requirements, and territorial considerations. I…
▽ More
Volume 3 of the FCC Feasibility Report presents studies related to civil engineering, the development of a project implementation scenario, and environmental and sustainability aspects. The report details the iterative improvements made to the civil engineering concepts since 2018, taking into account subsurface conditions, accelerator and experiment requirements, and territorial considerations. It outlines a technically feasible and economically viable civil engineering configuration that serves as the baseline for detailed subsurface investigations, construction design, cost estimation, and project implementation planning. Additionally, the report highlights ongoing subsurface investigations in key areas to support the development of an improved 3D subsurface model of the region.
The report describes development of the project scenario based on the 'avoid-reduce-compensate' iterative optimisation approach. The reference scenario balances optimal physics performance with territorial compatibility, implementation risks, and costs. Environmental field investigations covering almost 600 hectares of terrain - including numerous urban, economic, social, and technical aspects - confirmed the project's technical feasibility and contributed to the preparation of essential input documents for the formal project authorisation phase. The summary also highlights the initiation of public dialogue as part of the authorisation process. The results of a comprehensive socio-economic impact assessment, which included significant environmental effects, are presented. Even under the most conservative and stringent conditions, a positive benefit-cost ratio for the FCC-ee is obtained. Finally, the report provides a concise summary of the studies conducted to document the current state of the environment.
△ Less
Submitted 25 April, 2025;
originally announced May 2025.
-
Future Circular Collider Feasibility Study Report: Volume 1, Physics, Experiments, Detectors
Authors:
M. Benedikt,
F. Zimmermann,
B. Auchmann,
W. Bartmann,
J. P. Burnet,
C. Carli,
A. Chancé,
P. Craievich,
M. Giovannozzi,
C. Grojean,
J. Gutleber,
K. Hanke,
A. Henriques,
P. Janot,
C. Lourenço,
M. Mangano,
T. Otto,
J. Poole,
S. Rajagopalan,
T. Raubenheimer,
E. Todesco,
L. Ulrici,
T. Watson,
G. Wilkinson,
P. Azzi
, et al. (1439 additional authors not shown)
Abstract:
Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model.…
▽ More
Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model. The report reviews the experimental opportunities offered by the staged implementation of FCC, beginning with an electron-positron collider (FCC-ee), operating at several centre-of-mass energies, followed by a hadron collider (FCC-hh). Benchmark examples are given of the expected physics performance, in terms of precision and sensitivity to new phenomena, of each collider stage. Detector requirements and conceptual designs for FCC-ee experiments are discussed, as are the specific demands that the physics programme imposes on the accelerator in the domains of the calibration of the collision energy, and the interface region between the accelerator and the detector. The report also highlights advances in detector, software and computing technologies, as well as the theoretical tools /reconstruction techniques that will enable the precision measurements and discovery potential of the FCC experimental programme. This volume reflects the outcome of a global collaborative effort involving hundreds of scientists and institutions, aided by a dedicated community-building coordination, and provides a targeted assessment of the scientific opportunities and experimental foundations of the FCC programme.
△ Less
Submitted 25 April, 2025;
originally announced May 2025.
-
Automating Experimental Optics with Sample Efficient Machine Learning Methods
Authors:
Arindam Saha,
Baramee Charoensombutamon,
Thibault Michel,
V. Vijendran,
Lachlan Walker,
Akira Furusawa,
Syed M. Assad,
Ben C. Buchler,
Ping Koy Lam,
Aaron D. Tranter
Abstract:
As free-space optical systems grow in scale and complexity, troubleshooting becomes increasingly time-consuming and, in the case of remote installations, perhaps impractical. An example of a task that is often laborious is the alignment of a high-finesse optical resonator, which is highly sensitive to the mode of the input beam. In this work, we demonstrate how machine learning can be used to achi…
▽ More
As free-space optical systems grow in scale and complexity, troubleshooting becomes increasingly time-consuming and, in the case of remote installations, perhaps impractical. An example of a task that is often laborious is the alignment of a high-finesse optical resonator, which is highly sensitive to the mode of the input beam. In this work, we demonstrate how machine learning can be used to achieve autonomous mode-matching of a free-space optical resonator with minimal supervision. Our approach leverages sample-efficient algorithms to reduce data requirements while maintaining a simple architecture for easy deployment. The reinforcement learning scheme that we have developed shows that automation is feasible even in systems prone to drift in experimental parameters, as may well be the case in real-world applications.
△ Less
Submitted 18 March, 2025;
originally announced March 2025.
-
A color-corrected, high-contrast catadioptric relay for high-resolution biological photolithography
Authors:
Timm Michel,
Jürgen Behr,
Hamed Sabzalipoor,
Gisela Ibáñez-Redín,
Jory Lietard,
Thomas Schletterer,
Max Funck,
Mark M. Somoza
Abstract:
Large-scale synthesis of DNA and RNA is a crucial technology for modern biological research ranging from genomics to nucleic acid therapeutics and for technological research ranging from nanofabrication of materials to molecular-level writing of digital data. Maskless Array Synthesis (MAS) is a versatile and efficient approach for creating the required complex microarrays and libraries of DNA and…
▽ More
Large-scale synthesis of DNA and RNA is a crucial technology for modern biological research ranging from genomics to nucleic acid therapeutics and for technological research ranging from nanofabrication of materials to molecular-level writing of digital data. Maskless Array Synthesis (MAS) is a versatile and efficient approach for creating the required complex microarrays and libraries of DNA and other nucleic acids for these applications and, more generally, for the synthesis of sequence-defined engineered and biological oligomers. MAS uses digital photomasks displayed by a digital micromirror device (DMD) illuminated by an appropriate light source and imaged into a photochemical reaction chamber with an optical relay system. Previously, Offner relay systems were used for imaging, but modern DMD formats with more and smaller micromirrors favor a different solution. We present a desktop MAS optical system with the larger numerical aperture and larger field of view required by 1080p and other large-format DMDs. The resulting catadioptric relay is well suited to modern DMDs in this application, and is corrected for first order axial and lateral color, enabling the use of high-power LEDs as inexpensive and long-lasting light sources spanning the ultraviolet-to-violet to perform the required photochemistry. Additional characteristics of the system, including high contrast and low scatter, make it ideal for reducing the error rates in photochemical synthesis of biomolecules.
△ Less
Submitted 10 November, 2024;
originally announced November 2024.
-
Active Personal Eye Lens Dosimetry with the Hybrid Pixelated Dosepix Detector
Authors:
Florian Beißer,
Dennis Haag,
Rafael Ballabriga,
Rolf Behrens,
Michael Campbell,
Christian Fuhg,
Patrick Hufschmidt,
Oliver Hupe,
Carolin Kupillas,
Xavier Llopart,
Jürgen Roth,
Sebastian Schmidt,
Markus Schneider,
Lukas Tlustos,
Winnie Wong,
Hayo Zutz,
Thilo Michel,
Erlangen Centre for Astroparticle Physics,
CERN,
Physikalisch-Technische Bundesantalt,
was with the Erlangen Centre for Astroparticle Physics,
is now with Helene-Lange-Gymnasium,
was with the Erlangen Centre for Astroparticle Physics,
is now with CodeCamp,
:
, et al. (6 additional authors not shown)
Abstract:
Eye lens dosimetry has been an important field of research in the last decade. Dose measurements with a prototype of an active personal eye lens dosemeter based on the Dosepix detector are presented. The personal dose equivalent at $3\,$mm depth of soft tissue, $H_\text{p}(3)$, was measured in the center front of a water-filled cylinder phantom with a height and diameter of $20\,$cm. The energy de…
▽ More
Eye lens dosimetry has been an important field of research in the last decade. Dose measurements with a prototype of an active personal eye lens dosemeter based on the Dosepix detector are presented. The personal dose equivalent at $3\,$mm depth of soft tissue, $H_\text{p}(3)$, was measured in the center front of a water-filled cylinder phantom with a height and diameter of $20\,$cm. The energy dependence of the normalized response is investigated for mean photon energies between $12.4\,$keV and $248\,$keV for continuous reference radiation fields (N-series) according to ISO 4037. The response normalized to N-60 ($\overline{E}=47.9\,\text{keV}$) at $0^\circ$ angle of irradiation stays within the approval limits of IEC 61526 for angles of incidence between $-75^\circ$ and $+75^\circ$. Performance in pulsed photon fields was tested for varying dose rates from $0.1\,\frac{\text{Sv}}{\text{h}}$ up to $1000\,\frac{\text{Sv}}{\text{h}}$ and pulse durations from $1\,\text{ms}$ up to $10\,\text{s}$. The dose measurement works well within the approval limits (acc. to IEC 61526) up to $1\,\frac{\text{Sv}}{\text{h}}$. No significant influence of the pulse duration on the measured dose is found. Reproducibility measurements yield a coefficient of variation which does not exceed $1\,\%$ for two tested eye lens dosemeter prototypes.
△ Less
Submitted 1 August, 2023; v1 submitted 9 May, 2023;
originally announced May 2023.
-
Generative Adversarial Networks for Scintillation Signal Simulation in EXO-200
Authors:
S. Li,
I. Ostrovskiy,
Z. Li,
L. Yang,
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian
, et al. (65 additional authors not shown)
Abstract:
Generative Adversarial Networks trained on samples of simulated or actual events have been proposed as a way of generating large simulated datasets at a reduced computational cost. In this work, a novel approach to perform the simulation of photodetector signals from the time projection chamber of the EXO-200 experiment is demonstrated. The method is based on a Wasserstein Generative Adversarial N…
▽ More
Generative Adversarial Networks trained on samples of simulated or actual events have been proposed as a way of generating large simulated datasets at a reduced computational cost. In this work, a novel approach to perform the simulation of photodetector signals from the time projection chamber of the EXO-200 experiment is demonstrated. The method is based on a Wasserstein Generative Adversarial Network - a deep learning technique allowing for implicit non-parametric estimation of the population distribution for a given set of objects. Our network is trained on real calibration data using raw scintillation waveforms as input. We find that it is able to produce high-quality simulated waveforms an order of magnitude faster than the traditional simulation approach and, importantly, generalize from the training sample and discern salient high-level features of the data. In particular, the network correctly deduces position dependency of scintillation light response in the detector and correctly recognizes dead photodetector channels. The network output is then integrated into the EXO-200 analysis framework to show that the standard EXO-200 reconstruction routine processes the simulated waveforms to produce energy distributions comparable to that of real waveforms. Finally, the remaining discrepancies and potential ways to improve the approach further are highlighted.
△ Less
Submitted 8 May, 2023; v1 submitted 11 March, 2023;
originally announced March 2023.
-
Dynamic instability of individual carbon nanotube growth revealed by in situ homodyne polarization microscopy
Authors:
Vladimir Pimonov,
Huy-Nam Tran,
Léonard Monniello,
Saïd Tahir,
Thierry Michel,
Renaud Podor,
Michaël Odorico,
Christophe Bichara,
Vincent Jourdain
Abstract:
Understanding the kinetic selectivity of carbon nanotube growth at the scale of individual nanotubes is essential for the development of high chiral selectivity growth methods. Here we demonstrate that homodyne polarization microscopy can be used for high-throughput imaging of long individual carbon nanotubes under real growth conditions (at ambient pressure, on a substrate), and with sub-second t…
▽ More
Understanding the kinetic selectivity of carbon nanotube growth at the scale of individual nanotubes is essential for the development of high chiral selectivity growth methods. Here we demonstrate that homodyne polarization microscopy can be used for high-throughput imaging of long individual carbon nanotubes under real growth conditions (at ambient pressure, on a substrate), and with sub-second time resolution. Our in situ observations on hundreds of individual nanotubes reveal that about half of them grow at a constant rate all along their lifetime while the other half exhibits stochastic changes in growth rates, and switches between growth, pause and shrinkage. Statistical analysis shows that the growth rate of a given nanotube essentially varies between two values, with similar average ratio (~1.7) regardless of whether the rate change is accompanied by a change in chirality. These switches indicate that the nanotube edge or the catalyst nanoparticle fluctuates between different configurations during growth.
△ Less
Submitted 4 October, 2021;
originally announced October 2021.
-
Enhancing the precision limits of interferometric satellite geodesy missions
Authors:
Lorcan Conlon,
Thibault Michel,
Giovanni Guccione,
Kirk McKenzie,
Syed M. Assad,
Ping Koy Lam
Abstract:
Satellite geodesy uses the measurement of the motion of one or more satellites to infer precise information about the Earth's gravitational field. In this work, we consider the achievable precision limits on such measurements by examining approximate models for the three main noise sources in the measurement process of the current Gravitational Recovery and Climate Experiment (GRACE) Follow-On mis…
▽ More
Satellite geodesy uses the measurement of the motion of one or more satellites to infer precise information about the Earth's gravitational field. In this work, we consider the achievable precision limits on such measurements by examining approximate models for the three main noise sources in the measurement process of the current Gravitational Recovery and Climate Experiment (GRACE) Follow-On mission: laser phase noise, accelerometer noise and quantum noise. We show that, through time-delay interferometry, it is possible to remove the laser phase noise from the measurement, allowing for almost three orders of magnitude improvement in the signal-to-noise ratio. Several differential mass satellite formations are presented which can further enhance the signal-to-noise ratio through the removal of accelerometer noise. Finally, techniques from quantum optics have been studied, and found to have great promise for reducing quantum noise in other alternative mission configurations. We model the spectral noise performance using an intuitive 1D model and verify that our proposals have the potential to greatly enhance the performance of near-future satellite geodesy missions.
△ Less
Submitted 8 June, 2022; v1 submitted 15 September, 2021;
originally announced September 2021.
-
Laser astrophysics experiment on the amplification of magnetic fields by shock-induced interfacial instabilities
Authors:
Takayoshi Sano,
Shohei Tamatani,
Kazuki Matsuo,
King Fai Farley Law,
Taichi Morita,
Shunsuke Egashira,
Masato Ota,
Rajesh Kumar,
Hiroshi Shimogawara,
Yukiko Hara,
Seungho Lee,
Shohei Sakata,
Gabriel Rigon,
Thibault Michel,
Paul Mabey,
Bruno Albertazzi,
Michel Koenig,
Alexis Casner,
Keisuke Shigemori,
Shinsuke Fujioka,
Masakatsu Murakami,
Youichi Sakawa
Abstract:
Laser experiments are becoming established as a new tool for astronomical research that complements observations and theoretical modeling. Localized strong magnetic fields have been observed at a shock front of supernova explosions. Experimental confirmation and identification of the physical mechanism for this observation are of great importance in understanding the evolution of the interstellar…
▽ More
Laser experiments are becoming established as a new tool for astronomical research that complements observations and theoretical modeling. Localized strong magnetic fields have been observed at a shock front of supernova explosions. Experimental confirmation and identification of the physical mechanism for this observation are of great importance in understanding the evolution of the interstellar medium. However, it has been challenging to treat the interaction between hydrodynamic instabilities and an ambient magnetic field in the laboratory. Here, we developed an experimental platform to examine magnetized Richtmyer-Meshkov instability (RMI). The measured growth velocity was consistent with the linear theory, and the magnetic-field amplification was correlated with RMI growth. Our experiment validated the turbulent amplification of magnetic fields associated with the shock-induced interfacial instability in astrophysical conditions for the first time. Experimental elucidation of fundamental processes in magnetized plasmas is generally essential in various situations such as fusion plasmas and planetary sciences.
△ Less
Submitted 26 August, 2021;
originally announced August 2021.
-
The EXO-200 detector, part II: Auxiliary Systems
Authors:
N. Ackerman,
J. Albert,
M. Auger,
D. J. Auty,
I. Badhrees,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
V. Belov,
C. Benitez-Medina,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
R. Conley,
S. Cook,
M. Coon,
W. Craddock,
A. Craycraft,
W. Cree,
T. Daniels,
L. Darroch
, et al. (135 additional authors not shown)
Abstract:
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector op…
▽ More
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.
△ Less
Submitted 22 October, 2021; v1 submitted 13 July, 2021;
originally announced July 2021.
-
NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity
Authors:
nEXO Collaboration,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
G. Anton,
I. J. Arnquist,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
D. Chernyak,
M. Chiu,
B. Cleveland
, et al. (136 additional authors not shown)
Abstract:
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the…
▽ More
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of $10^{28}$ years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. The effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.
△ Less
Submitted 22 February, 2022; v1 submitted 30 June, 2021;
originally announced June 2021.
-
Personal Dosimetry in Direct Pulsed Photon Fields with the Dosepix Detector
Authors:
Dennis Haag,
Sebastian Schmidt,
Patrick Hufschmidt,
Gisela Anton,
Rafael Ballabriga,
Rolf Behrens,
Michael Campbell,
Franziska Eberle,
Christian Fuhg,
Oliver Hupe,
Xavier Llopart,
Jürgen Roth,
Lukas Tlustos,
Winnie Wong,
Hayo Zutz,
Thilo Michel
Abstract:
First investigations regarding dosimetric properties of the hybrid, pixelated, photon-counting Dosepix detector in the direct beam of a pulsed photon field (RQR8) for the personal dose equivalent $H\mathrm{_p(10)}$ are presented. The influence quantities such as pulse duration and dose rate were varied, and their responses were compared to the legal limits provided in PTB-A 23.2. The variation of…
▽ More
First investigations regarding dosimetric properties of the hybrid, pixelated, photon-counting Dosepix detector in the direct beam of a pulsed photon field (RQR8) for the personal dose equivalent $H\mathrm{_p(10)}$ are presented. The influence quantities such as pulse duration and dose rate were varied, and their responses were compared to the legal limits provided in PTB-A 23.2. The variation of pulse duration at a nearly constant dose rate of about 3.7$\,$Sv/h shows a flat response around 1.0 from 3.6$\,$s down to 2$\,$ms. A response close to 1.0 is achieved for dose rates from 0.07$\,$Sv/h to 35$\,$Sv/h for both pixel sizes. Above this dose rate, the large pixels (220$\,μ$m edge length) are below the lower limit. The small pixels (55$\,μ$m edge length) stay within limits up to 704$\,$Sv/h. The count rate linearity is compared to previous results, confirming the saturating count rate for high dose rates.
△ Less
Submitted 30 November, 2022; v1 submitted 12 June, 2021;
originally announced June 2021.
-
Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon
Authors:
M. Wagenpfeil,
T. Ziegler,
J. Schneider,
A. Fieguth,
M. Murra,
D. Schulte,
L. Althueser,
C. Huhmann,
C. Weinheimer,
T. Michel,
G. Anton,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
I. Badhrees,
J. Bane,
D. Beck,
V. Belov,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (118 additional authors not shown)
Abstract:
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows t…
▽ More
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. The reflectivity is determined to be 25-36% at an angle of incidence of 20° for the four samples and increases to up to 65% at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.
△ Less
Submitted 26 May, 2021; v1 submitted 16 April, 2021;
originally announced April 2021.
-
Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage
Authors:
T. Stiegler,
S. Sangiorgio,
J. P. Brodsky,
M. Heffner,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon
, et al. (126 additional authors not shown)
Abstract:
nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier…
▽ More
nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. In this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the $γ$-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Second, background from ${}^{222}Rn$ dissolved in the skin LXe can be efficiently rejected by tagging the $α$ decay in the ${}^{214}Bi-{}^{214}Po$ chain in the skin LXe.
△ Less
Submitted 24 March, 2021; v1 submitted 21 September, 2020;
originally announced September 2020.
-
Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths
Authors:
P. Lv,
G. F. Cao,
L. J. Wen,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
S. Byrne Mamahit,
E. Caden,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon,
A. Craycraft
, et al. (126 additional authors not shown)
Abstract:
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinct…
▽ More
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinction coefficient of the thin silicon-dioxide film deposited on the surface of the FBK SiPMs are derived from reflectance data of a FBK silicon wafer with the same deposited oxide film as SiPMs. The diffuse reflectance of SiPMs is also measured at 193 nm. We use the VUV spectral dependence of the optical constants to predict the reflectance of the FBK silicon wafer and FBK SiPMs in liquid xenon.
△ Less
Submitted 4 December, 2019;
originally announced December 2019.
-
Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode
Authors:
O. Njoya,
T. Tsang,
M. Tarka,
W. Fairbank,
K. S. Kumar,
T. Rao,
T. Wager,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
B. Chana,
S. A. Charlebois
, et al. (131 additional authors not shown)
Abstract:
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measur…
▽ More
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measured drift velocities and corresponding temperature coefficients respectively are $1.97 \pm 0.04$ mm/$μ$s and $(-0.69\pm0.05)$\%/K for liquid xenon, and $1.42 \pm 0.03$ mm/$μ$s and $(+0.11\pm0.01)$\%/K for gaseous xenon at 1.5 bar. In addition, we measure longitudinal diffusion coefficients of $25.7 \pm 4.6$ cm$^2$/s and $149 \pm 23$ cm$^2$/s, for liquid and gas, respectively. The quantum efficiency of the gold photocathode is studied at the photon energy of 4.73 eV in liquid and gaseous xenon, and vacuum. These charge transport properties and the behavior of photocathodes in a xenon environment are important in designing and calibrating future large scale noble liquid detectors.
△ Less
Submitted 24 November, 2019;
originally announced November 2019.
-
Reflectivity and PDE of VUV4 Hamamatsu SiPMs in Liquid Xenon
Authors:
P. Nakarmi,
I. Ostrovskiy,
A. K. Soma,
F. Retiere,
S. Al Kharusi,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. Blatchford,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
S. Byrne Mamahit,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois
, et al. (130 additional authors not shown)
Abstract:
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently a…
▽ More
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 micrometer micro-cells conducted with xenon scintillation light (~175 nm) in liquid xenon. The specular reflectivity at 15 deg. incidence of three samples of VUV4 SiPMs is found to be 30.4+/-1.4%, 28.6+/-1.3%, and 28.0+/-1.3%, respectively. The PDE at normal incidence differs by +/-8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was also measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.
△ Less
Submitted 24 December, 2019; v1 submitted 14 October, 2019;
originally announced October 2019.
-
Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment
Authors:
EXO-200 Collaboration,
:,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling,
A. Dolgolenko
, et al. (78 additional authors not shown)
Abstract:
Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by $γ$ interactions from $^{228}$Th (2615~keV), $^{226}$Ra (1764~keV) and $^{60}$Co (1332~keV and 1173~keV) calibration sources, over a range of electric fields. The $W$-value that defines the…
▽ More
Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by $γ$ interactions from $^{228}$Th (2615~keV), $^{226}$Ra (1764~keV) and $^{60}$Co (1332~keV and 1173~keV) calibration sources, over a range of electric fields. The $W$-value that defines the recombination-independent energy scale is measured to be $11.5~\pm~0.5$~(syst.)~$\pm~0.1$~(stat.) eV. These data are also used to measure the recombination fluctuations in the number of electrons and photons produced by the calibration sources at the MeV-scale, which deviate from extrapolations of lower-energy data. Additionally, a semi-empirical model for the energy resolution of the detector is developed, which is used to constrain the recombination efficiency, i.e., the fraction of recombined electrons that result in the emission of a detectable photon. Detailed measurements of the absolute charge and light yields for MeV-scale electron recoils are important for predicting the performance of future neutrinoless double beta decay detectors.
△ Less
Submitted 15 June, 2020; v1 submitted 12 August, 2019;
originally announced August 2019.
-
Simulation of charge readout with segmented tiles in nEXO
Authors:
Z. Li,
W. R. Cen,
A. Robinson,
D. C. Moore,
L. J. Wen,
A. Odian,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland
, et al. (128 additional authors not shown)
Abstract:
nEXO is a proposed experiment to search for the neutrino-less double beta decay ($0νββ$) of $^{136}$Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC will be equipped with charge collection tiles to form the anode. In this work, the charge reconstruction performance of this anode design is studied with a dedicated simulation package. A multi-variate method and a deep neu…
▽ More
nEXO is a proposed experiment to search for the neutrino-less double beta decay ($0νββ$) of $^{136}$Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC will be equipped with charge collection tiles to form the anode. In this work, the charge reconstruction performance of this anode design is studied with a dedicated simulation package. A multi-variate method and a deep neural network are developed to distinguish simulated $0νββ$ signals from backgrounds arising from trace levels of natural radioactivity in the detector materials. These simulations indicate that the nEXO TPC with charge-collection tiles shows promising capability to discriminate the $0νββ$ signal from backgrounds. The estimated half-life sensitivity for $0νββ$ decay is improved by $\sim$20$~(32)\%$ with the multi-variate~(deep neural network) methods considered here, relative to the sensitivity estimated in the nEXO pre-conceptual design report.
△ Less
Submitted 11 October, 2019; v1 submitted 17 July, 2019;
originally announced July 2019.
-
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
Authors:
G. Gallina,
P. Giampa,
F. Retiere,
J. Kroeger,
G. Zhang,
M. Ward,
P. Margetak,
G. Lic,
T. Tsang,
L. Doria,
S. Al Kharusi,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. Blatchford,
J. P. Brodsky,
E. Brown,
T. Brunner,
G. F. Cao,
L. Cao
, et al. (126 additional authors not shown)
Abstract:
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency…
▽ More
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233 \text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163 \text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse in the $1 \upmu\text{s}$ interval following the trigger pulse of $0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is $0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of $189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both values are well below the $24\text{ }\%$ saturation PDE advertised by Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
△ Less
Submitted 7 June, 2019; v1 submitted 8 March, 2019;
originally announced March 2019.
-
A comprehensive model of the optical spectra of carbon nanotubes on substrate by polarized microscopy
Authors:
Léonard Monniello,
Huy-Nam Tran,
Rémy Vialla,
Guillaume Prévot,
Said Tahir,
Thierry Michel,
Vincent Jourdain
Abstract:
Polarized optical microscopy and spectroscopy are progressively becoming key methods for the high-throughput characterization of individual carbon nanotubes (CNTs) and other one-dimensional nanostructures, on substrate and in devices. The optical response of CNTs on substrate in cross polarization experiments is usually limited by the polarization conservation of the optical elements in the experi…
▽ More
Polarized optical microscopy and spectroscopy are progressively becoming key methods for the high-throughput characterization of individual carbon nanotubes (CNTs) and other one-dimensional nanostructures, on substrate and in devices. The optical response of CNTs on substrate in cross polarization experiments is usually limited by the polarization conservation of the optical elements in the experimental setup. We developed a theoretical model taking into account the depolarization by the setup and the optical response of the substrate. We show that proper modelization of the experimental data requires to take into account both non-coherent and coherent light depolarization by the optical elements. We also show how the nanotube signal can be decoupled from the complex reflection factor of the anti-reflection substrate which is commonly used to enhance the optical contrast. Finally, we describe an experimental protocol to extract the depolarization parameters and the complex nanotube susceptibility, and how it can improve the chirality assignment of individual carbon nanotubes in complex cases.
△ Less
Submitted 23 November, 2018;
originally announced November 2018.
-
Study of Silicon Photomultiplier Performance in External Electric Fields
Authors:
X. L. Sun,
T. Tolba,
G. F. Cao,
P. Lv,
L. J. Wen,
A. Odian,
F. Vachon,
A. Alamre,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois
, et al. (127 additional authors not shown)
Abstract:
We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estima…
▽ More
We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estimated uncertainties. No observable physical damage to the bulk or surface of the devices was caused by the exposure.
△ Less
Submitted 9 July, 2018;
originally announced July 2018.
-
Imaging individual barium atoms in solid xenon for barium tagging in nEXO
Authors:
C. Chambers,
T. Walton,
D. Fairbank,
A. Craycraft,
D. R. Yahne,
J. Todd,
A. Iverson,
W. Fairbank,
A. Alamare,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen
, et al. (126 additional authors not shown)
Abstract:
The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a…
▽ More
The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a technique for eliminating backgrounds in the nEXO neutrinoless double beta decay experiment. The tagging scheme studied in this work utilizes a cryogenic probe to trap the barium atom in solid xenon, where the barium atom is tagged via fluorescence imaging in the solid xenon matrix. Here we demonstrate imaging and counting of individual atoms of barium in solid xenon by scanning a focused laser across a solid xenon matrix deposited on a sapphire window. When the laser sits on an individual atom, the fluorescence persists for $\sim$30~s before dropping abruptly to the background level, a clear confirmation of one-atom imaging. No barium fluorescence persists following evaporation of a barium deposit to a limit of $\leq$0.16\%. This is the first time that single atoms have been imaged in solid noble element. It establishes the basic principle of a barium tagging technique for nEXO.
△ Less
Submitted 12 December, 2018; v1 submitted 27 June, 2018;
originally announced June 2018.
-
VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO
Authors:
A. Jamil,
T. Ziegler,
P. Hufschmidt,
G. Li,
L. Lupin-Jimenez,
T. Michel,
I. Ostrovskiy,
F. Retière,
J. Schneider,
M. Wagenpfeil,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. Barbeau,
D. Beck,
V. Belov,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers
, et al. (118 additional authors not shown)
Abstract:
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area avalanche photodiodes. The next generation double beta decay experiment, nEXO, with a 5 tonne liquid xenon time projection chamber, will use SiPMs for detecting t…
▽ More
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area avalanche photodiodes. The next generation double beta decay experiment, nEXO, with a 5 tonne liquid xenon time projection chamber, will use SiPMs for detecting the $178\,\text{nm}$ xenon scintillation light, in order to achieve an energy resolution of $σ/ Q_{ββ} = 1\, \%$. This paper presents recent measurements of the VUV-HD generation SiPMs from Fondazione Bruno Kessler in two complementary setups. It includes measurements of the photon detection efficiency with gaseous xenon scintillation light in a vacuum setup and dark measurements in a dry nitrogen gas setup. We report improved photon detection efficiency at $175\,\text{nm}$ compared to previous generation devices, that would meet the criteria of nEXO. Furthermore, we present the projected nEXO detector light collection and energy resolution that could be achieved by using these SiPMs.
△ Less
Submitted 13 March, 2019; v1 submitted 6 June, 2018;
originally announced June 2018.
-
nEXO Pre-Conceptual Design Report
Authors:
nEXO Collaboration,
S. Al Kharusi,
A. Alamre,
J. B. Albert,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
R. Conley
, et al. (149 additional authors not shown)
Abstract:
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of app…
▽ More
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of approximately $10^{28}$ years. This represents an improvement in sensitivity of about two orders of magnitude with respect to current results. Based on the experience gained from EXO-200 and the effectiveness of xenon purification techniques, we expect the background to be dominated by external sources of radiation. The sensitivity increase is, therefore, entirely derived from the increase of active mass in a monolithic and homogeneous detector, along with some technical advances perfected in the course of a dedicated R&D program. Hence the risk which is inherent to the construction of a large, ultra-low background detector is reduced, as the intrinsic radioactive contamination requirements are generally not beyond those demonstrated with the present generation $0νββ$ decay experiments. Indeed, most of the required materials have been already assayed or reasonable estimates of their properties are at hand. The details described herein represent the base design of the detector configuration as of early 2018. Where potential design improvements are possible, alternatives are discussed.
This design for nEXO presents a compelling path towards a next generation search for $0νββ$, with a substantial possibility to discover physics beyond the Standard Model.
△ Less
Submitted 13 August, 2018; v1 submitted 28 May, 2018;
originally announced May 2018.
-
Phase-Sensitive Region-of-Interest Computed Tomography
Authors:
Lina Felsner,
Martin Berger,
Sebastian Kaeppler,
Johannes Bopp,
Veronika Ludwig,
Thomas Weber,
Georg Pelzer,
Thilo Michel,
Andreas Maier,
Gisela Anton,
Christian Riess
Abstract:
X-Ray Phase-Contrast Imaging (PCI) yields absorption, differential phase, and dark-field images. Computed Tomography (CT) of grating-based PCI can in principle provide high-resolution soft-tissue contrast. Recently, grating-based PCI took several hurdles towards clinical implementation by addressing, for example, acquisition speed, high X-ray energies, and system vibrations. However, a critical im…
▽ More
X-Ray Phase-Contrast Imaging (PCI) yields absorption, differential phase, and dark-field images. Computed Tomography (CT) of grating-based PCI can in principle provide high-resolution soft-tissue contrast. Recently, grating-based PCI took several hurdles towards clinical implementation by addressing, for example, acquisition speed, high X-ray energies, and system vibrations. However, a critical impediment in all grating-based systems lies in limits that constrain the grating diameter to few centimeters. In this work, we propose a system and a reconstruction algorithm to circumvent this constraint in a clinically compatible way. We propose to perform a phase-sensitive Region-of-Interest (ROI) CT within a full-field absorption CT. The biggest advantage of this approach is that it allows to correct for phase truncation artifacts, and to obtain quantitative phase values. Our method is robust, and shows high-quality results on simulated data and on a biological mouse sample. This work is a proof of concept showing the potential to use PCI in CT on large specimen, such as humans, in clinical applications.
△ Less
Submitted 24 May, 2018;
originally announced May 2018.
-
Deep Neural Networks for Energy and Position Reconstruction in EXO-200
Authors:
S. Delaquis,
M. J. Jewell,
I. Ostrovskiy,
M. Weber,
T. Ziegler,
J. Dalmasson,
L. J. Kaufman,
T. Richards,
J. B. Albert,
G. Anton,
I. Badhrees,
P. S. Barbeau,
R. Bayerlein,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
W. Cree,
T. Daniels
, et al. (69 additional authors not shown)
Abstract:
We apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters - total energy and position - directly from raw digitized waveforms, with minimal exceptions. For the first time, the developed algorithms are evaluated on real detector calibration data. The accuracy of reconstruction either reaches or exceeds what…
▽ More
We apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters - total energy and position - directly from raw digitized waveforms, with minimal exceptions. For the first time, the developed algorithms are evaluated on real detector calibration data. The accuracy of reconstruction either reaches or exceeds what was achieved by the conventional approaches developed by EXO-200 over the course of the experiment. Most existing DNN approaches to event reconstruction and classification in particle physics are trained on Monte Carlo simulated events. Such algorithms are inherently limited by the accuracy of the simulation. We describe a unique approach that, in an experiment such as EXO-200, allows to successfully perform certain reconstruction and analysis tasks by training the network on waveforms from experimental data, either reducing or eliminating the reliance on the Monte Carlo.
△ Less
Submitted 30 August, 2018; v1 submitted 25 April, 2018;
originally announced April 2018.
-
Search for nucleon decays with EXO-200
Authors:
J. B. Albert,
G. Anton,
I. Badhrees,
P. S. Barbeau,
R. Bayerlein,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
W. Cree,
T. Daniels,
M. Danilov,
S. J. Daugherty,
J. Daughhetee,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
T. Didberidze
, et al. (70 additional authors not shown)
Abstract:
A search for instability of nucleons bound in $^{136}$Xe nuclei is reported with 223 kg$\cdot$yr exposure of $^{136}$Xe in the EXO-200 experiment. Lifetime limits of 3.3$\times 10^{23}$ and 1.9$\times 10^{23}$ yrs are established for nucleon decay to $^{133}$Sb and $^{133}$Te, respectively. These are the most stringent to date, exceeding the prior decay limits by a factor of 9 and 7, respectively.
A search for instability of nucleons bound in $^{136}$Xe nuclei is reported with 223 kg$\cdot$yr exposure of $^{136}$Xe in the EXO-200 experiment. Lifetime limits of 3.3$\times 10^{23}$ and 1.9$\times 10^{23}$ yrs are established for nucleon decay to $^{133}$Sb and $^{133}$Te, respectively. These are the most stringent to date, exceeding the prior decay limits by a factor of 9 and 7, respectively.
△ Less
Submitted 11 April, 2018; v1 submitted 20 October, 2017;
originally announced October 2017.
-
Characterization of an Ionization Readout Tile for nEXO
Authors:
nEXO Collaboration,
M. Jewell,
A. Schubert,
W. R. Cen,
J. Dalmasson,
R. DeVoe,
L. Fabris,
G. Gratta,
A. Jamil,
G. Li,
A. Odian,
M. Patel,
A. Pocar,
D. Qiu,
Q. Wang,
L. J. Wen,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. Barbeau,
D. Beck,
V. Belov,
F. Bourque,
J. P. Brodsky
, et al. (120 additional authors not shown)
Abstract:
A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3~mm wide, on a 10~\si{\cm} $\times$ 10~\si{\cm} fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale n…
▽ More
A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3~mm wide, on a 10~\si{\cm} $\times$ 10~\si{\cm} fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale nEXO experiment to search for neutrinoless double-beta decay. Modular by design, an array of tiles can cover a sizable area. The width of each strip is small compared to the size of the tile, so a Frisch grid is not required. A grid-less, tiled anode design is beneficial for an experiment such as nEXO, where a wire tensioning support structure and Frisch grid might contribute radioactive backgrounds and would have to be designed to accommodate cycling to cryogenic temperatures. The segmented anode also reduces some degeneracies in signal reconstruction that arise in large-area crossed-wire time projection chambers. A prototype tile was tested in a cell containing liquid xenon. Very good agreement is achieved between the measured ionization spectrum of a $^{207}$Bi source and simulations that include the microphysics of recombination in xenon and a detailed modeling of the electrostatic field of the detector. An energy resolution $σ/E$=5.5\% is observed at 570~\si{keV}, comparable to the best intrinsic ionization-only resolution reported in literature for liquid xenon at 936~V/\si{cm}.
△ Less
Submitted 19 January, 2018; v1 submitted 13 October, 2017;
originally announced October 2017.
-
Sensitivity and discovery potential of the proposed nEXO experiment to neutrinoless double beta decay
Authors:
nEXO Collaboration,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon,
M. Côté,
A. Craycraft,
W. Cree,
J. Dalmasson
, et al. (121 additional authors not shown)
Abstract:
The next-generation Enriched Xenon Observatory (nEXO) is a proposed experiment to search for neutrinoless double beta ($0νββ$) decay in $^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years using $5\times10^3$ kg of isotopically enriched liquid-xenon in a time projection chamber. This improvement of two orders of magnitude in sensitivity over current limits is obtained by…
▽ More
The next-generation Enriched Xenon Observatory (nEXO) is a proposed experiment to search for neutrinoless double beta ($0νββ$) decay in $^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years using $5\times10^3$ kg of isotopically enriched liquid-xenon in a time projection chamber. This improvement of two orders of magnitude in sensitivity over current limits is obtained by a significant increase of the $^{136}$Xe mass, the monolithic and homogeneous configuration of the active medium, and the multi-parameter measurements of the interactions enabled by the time projection chamber. The detector concept and anticipated performance are presented based upon demonstrated realizable background rates.
△ Less
Submitted 19 October, 2018; v1 submitted 13 October, 2017;
originally announced October 2017.
-
Trace radioactive impurities in final construction materials for EXO-200
Authors:
D. S. Leonard,
D. Auty,
T. Didberidze,
R. Gornea,
P. Grinberg,
R. MacLellan,
B. Methven,
A. Piepke,
J. -L. Vuilleumier,
J. B. Albert,
G. Anton,
I. Badhrees,
P. S. Barbeau,
R. Bayerlein,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
W. Cree
, et al. (76 additional authors not shown)
Abstract:
We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial results from this campaign have already been reported in a 2008 paper by the EXO collaboration. Here we release the remaining data, collected since 2007, to the public. The data reported were obtained using a variety of…
▽ More
We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial results from this campaign have already been reported in a 2008 paper by the EXO collaboration. Here we release the remaining data, collected since 2007, to the public. The data reported were obtained using a variety of analytic techniques. The measurement sensitivities are among the best in the field. Construction of the EXO-200 detector has been concluded, and Phase-I data was taken from 2011 to 2014. The detector's extremely low background implicitly verifies the measurements and the analysis assumptions made during construction and reported in this paper.
△ Less
Submitted 31 March, 2017;
originally announced March 2017.
-
The COBRA demonstrator at the LNGS underground laboratory
Authors:
The COBRA collaboration,
J. Ebert,
M. Fritts,
D. Gehre,
C. Gößling,
T. Göpfert,
C. Hagner,
N. Heidrich,
R. Klingenberg,
T. Köttig,
K. Kröninger,
T. Michel,
T. Neddermann,
C. Nitsch,
C. Oldorf,
T. Quante,
S. Rajek,
H. Rebber,
O. Reinecke,
K. Rohatsch,
O. Schulz,
A. Sörensen,
I. Stekl,
J. Tebrügge,
R. Temminghoff
, et al. (6 additional authors not shown)
Abstract:
The COBRA demonstrator, a prototype for a large-scale experiment searching for neutrinoless double beta-decay, was built at the underground laboratory Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It consists of an array of 64 monolithic, calorimetric CdZnTe semiconductor detectors with a coplanar-grid design and a total mass of 380g. It is used to investigate the experimental challenges fa…
▽ More
The COBRA demonstrator, a prototype for a large-scale experiment searching for neutrinoless double beta-decay, was built at the underground laboratory Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It consists of an array of 64 monolithic, calorimetric CdZnTe semiconductor detectors with a coplanar-grid design and a total mass of 380g. It is used to investigate the experimental challenges faced when operating CdZnTe detectors in low-background mode, to identify potential background sources and to show the long-term stability of the detectors. The first data-taking period started in 2011 with a subset of the detectors, while the demonstrator was completed in November 2013. To date, more than 250kg d of data have been collected. This paper describes technical details of the experimental setup and the hardware components.
△ Less
Submitted 18 November, 2015; v1 submitted 29 July, 2015;
originally announced July 2015.
-
Detection of non-classical space-time correlations with a novel type of single-photon camera
Authors:
Felix Just,
Mykhaylo Filipenko,
Andrea Cavanna,
Thilo Michel,
Thomas Gleixner,
Michael Taheri,
John Vallerga,
Michael Campbell,
Timo Tick,
Gisela Anton,
Maria V. Chekhova,
Gerd Leuchs
Abstract:
During the last decades, multi-pixel detectors have been developed capable of registering single photons. The newly developed Hybrid Photon Detector camera has a remarkable property that it has not only spatial but also temporal resolution. In this work, we use this device for the detection of non-classical light from spontaneous parametric down-conversion and use two-photon correlations for the a…
▽ More
During the last decades, multi-pixel detectors have been developed capable of registering single photons. The newly developed Hybrid Photon Detector camera has a remarkable property that it has not only spatial but also temporal resolution. In this work, we use this device for the detection of non-classical light from spontaneous parametric down-conversion and use two-photon correlations for the absolute calibration of its quantum efficiency.
△ Less
Submitted 28 April, 2014;
originally announced April 2014.
-
Three dimensional photograph of single electron tracks through a scintillator
Authors:
Mykhaylo Filipenko,
Timur Ishakov,
Patrick Hufschmidt,
Gisela Anton,
Michael Campbell,
Thomas Gleixner,
Gerd Leuchs,
Timo Tick,
John Vallerga,
Michael Wagenpfeil,
Thilo Michel
Abstract:
The reconstruction of particle trajectories makes it possible to distinguish between different types of charged particles. In high-energy physics, where trajectories are rather long, large size trackers must be used to achieve sufficient position resolution. However, in low-background experiments tracks are rather short and three dimensional trajectories could only be resolved in time-projection c…
▽ More
The reconstruction of particle trajectories makes it possible to distinguish between different types of charged particles. In high-energy physics, where trajectories are rather long, large size trackers must be used to achieve sufficient position resolution. However, in low-background experiments tracks are rather short and three dimensional trajectories could only be resolved in time-projection chambers so far. For detectors of large volume and therefore large drift distances, which are inevitable for low-background experiments, this technique is limited by diffusion of charge carriers. In this work we present a "proof-of-principle" experiment for a new method for the three dimensional tracking of charged particles by scintillation light: We used a setup consisting of a scintillator, mirrors, lenses and a novel imaging device (the hybrid photo detector) in order to image two projections of electron tracks through the scintillator. We took data at the T-24 beam-line at DESY with relativistic electrons with a kinetic energy of 5 GeV and from this data successfully reconstructed their three dimensional propagetion path in the scintillator. With our setup we achieved a position resolution of about 28 mum in the best case.
△ Less
Submitted 22 April, 2014; v1 submitted 15 April, 2014;
originally announced April 2014.
-
3D Particle Track Reconstrution in a Single Layer Cadmium-Telluride Hybrid Active Pixel Detector
Authors:
Mykhaylo Filipenko,
Thomas Gleixner,
Gisela Anton,
Thilo Michel
Abstract:
In the past 20 years the search for neutrinoless double beta decay has driven many developements in all kind of detector technology. A new branch in this field are highly-pixelated semiconductor detectors - such as the CdTe-Timepix detectors. It compromises a cadmium-telluride sensor of 14 mm x 14 mm x 1 mm size with an ASIC which has 256 x 256 pixel of 55 \textmu m pixel pitch and can be used to…
▽ More
In the past 20 years the search for neutrinoless double beta decay has driven many developements in all kind of detector technology. A new branch in this field are highly-pixelated semiconductor detectors - such as the CdTe-Timepix detectors. It compromises a cadmium-telluride sensor of 14 mm x 14 mm x 1 mm size with an ASIC which has 256 x 256 pixel of 55 \textmu m pixel pitch and can be used to obtain either spectroscopic or timing information in every pixel. In regular operation it can provide a 2D projection of particle trajectories; however, three dimensional trajectories are desirable for neutrinoless double beta decay and other applications. In this paper we present a method to obtain such trajectories. The method was developed and tested with simulations that assume some minor modifications to the Timepix ASIC. Also, we were able to test the method experimentally and in the best case achieved a position resolution of about 90 \textmu m with electrons of 4.4 GeV.
△ Less
Submitted 24 March, 2014;
originally announced March 2014.
-
Simultaneous maximum-likelihood reconstruction for x-ray grating based phase-contrast tomography avoiding intermediate phase retrieval
Authors:
André Ritter,
Florian Bayer,
Jürgen Durst,
Karl Gödel,
Wilhelm Haas,
Thilo Michel,
Jens Rieger,
Thomas Weber,
Lukas Wucherer,
Gisela Anton
Abstract:
Phase-wrapping artifacts, statistical image noise and the need for a minimum amount of phase steps per projection limit the practicability of x-ray grating based phase-contrast tomography, when using filtered back projection reconstruction. For conventional x-ray computed tomography, the use of statistical iterative reconstruction algorithms has successfully reduced artifacts and statistical issue…
▽ More
Phase-wrapping artifacts, statistical image noise and the need for a minimum amount of phase steps per projection limit the practicability of x-ray grating based phase-contrast tomography, when using filtered back projection reconstruction. For conventional x-ray computed tomography, the use of statistical iterative reconstruction algorithms has successfully reduced artifacts and statistical issues. In this work, an iterative reconstruction method for grating based phase-contrast tomography is presented. The method avoids the intermediate retrieval of absorption, differential phase and dark field projections. It directly reconstructs tomographic cross sections from phase stepping projections by the use of a forward projecting imaging model and an appropriate likelihood function. The likelihood function is then maximized with an iterative algorithm. The presented method is tested with tomographic data obtained through a wave field simulation of grating based phase-contrast tomography. The reconstruction results are in agreement with the expectations and proof the validity of the concept.
△ Less
Submitted 30 July, 2013;
originally announced July 2013.
-
Investigation of the signature of lung tissue in X-ray grating-based phase-contrast imaging
Authors:
Thomas Weber,
Florian Bayer,
Wilhelm Haas,
Georg Pelzer,
Jens Rieger,
André Ritter,
Lukas Wucherer,
Jan Matthias Braun,
Jürgen Durst,
Thilo Michel,
Gisela Anton
Abstract:
Purpose: Grating-based X-ray phase-contrast imaging is a promising modality increasing the soft tissue contrast in medical imaging. In this work, the signature of lung tissue in X-ray grating-based physe-contrast imaging is investigated. Methods: We used a Talbot-Lau interferometer for our investigations of two C57BL/6 mice. Both underwent projection imaging and computed tomography. Results: The r…
▽ More
Purpose: Grating-based X-ray phase-contrast imaging is a promising modality increasing the soft tissue contrast in medical imaging. In this work, the signature of lung tissue in X-ray grating-based physe-contrast imaging is investigated. Methods: We used a Talbot-Lau interferometer for our investigations of two C57BL/6 mice. Both underwent projection imaging and computed tomography. Results: The results show that the three images obtained by X-ray phase-contrast imaging show complementary anatomical structures. Especially the dark field image allows a more-exact determination of the position of the lung in the chest cavity. Conclusion: Due to its sensitivity to granular structures, the dark field image may be used for the diagnosis of lung diseases in earlier stages or without a CT scan. Furthermore, X-ray phase-contrast imaging may also have great potential in the application of animal laboratory sciences to reduce the number of required animals used in long-term translational, toxicity, and regenerative medicine studies.
△ Less
Submitted 20 December, 2012;
originally announced December 2012.
-
Charged Particle Tracking with the Timepix ASIC
Authors:
Kazuyoshi Akiba,
Marina Artuso,
Ryan Badman,
Alessandra Borgia,
Richard Bates,
Florian Bayer,
Martin van Beuzekom,
Jan Buytaert,
Enric Cabruja,
Michael Campbell,
Paula Collins,
Michael Crossley,
Raphael Dumps,
Lars Eklund,
Daniel Esperante,
Celeste Fleta,
Abraham Gallas,
Miriam Gandelman,
Justin Garofoli,
Marco Gersabeck,
Vladimir V. Gligorov,
Hamish Gordon,
Erik H. M. Heijne,
Veerle Heijne,
Daniel Hynds
, et al. (17 additional authors not shown)
Abstract:
A prototype particle tracking telescope has been constructed using Timepix and Medipix ASIC hybrid pixel assemblies as the six sensing planes. Each telescope plane consisted of one 1.4 cm2 assembly, providing a 256x256 array of 55 micron square pixels. The telescope achieved a pointing resolution of 2.3 micron at the position of the device under test. During a beam test in 2009 the telescope was u…
▽ More
A prototype particle tracking telescope has been constructed using Timepix and Medipix ASIC hybrid pixel assemblies as the six sensing planes. Each telescope plane consisted of one 1.4 cm2 assembly, providing a 256x256 array of 55 micron square pixels. The telescope achieved a pointing resolution of 2.3 micron at the position of the device under test. During a beam test in 2009 the telescope was used to evaluate in detail the performance of two Timepix hybrid pixel assemblies; a standard planar 300 micron thick sensor, and 285 micron thick double sided 3D sensor. This paper describes a detailed charge calibration study of the pixel devices, which allows the true charge to be extracted, and reports on measurements of the charge collection characteristics and Landau distributions. The planar sensor achieved a best resolution of 4.0 micron for angled tracks, and resolutions of between 4.4 and 11 micron for perpendicular tracks, depending on the applied bias voltage. The double sided 3D sensor, which has significantly less charge sharing, was found to have an optimal resolution of 9.0 micron for angled tracks, and a resolution of 16.0 micron for perpendicular tracks. Based on these studies it is concluded that the Timepix ASIC shows an excellent performance when used as a device for charged particle tracking.
△ Less
Submitted 14 June, 2011; v1 submitted 14 March, 2011;
originally announced March 2011.