-
First measurement of muon-neutrino disappearance in NOvA
Authors:
P. Adamson,
C. Ader,
M. Andrews,
N. Anfimov,
I. Anghel,
K. Arms,
E. Arrieta-Diaz,
A. Aurisano,
D. Ayres,
C. Backhouse,
M. Baird,
B. A. Bambah,
K. Bays,
R. Bernstein,
M. Betancourt,
V. Bhatnagar,
B. Bhuyan,
J. Bian,
K. Biery,
T. Blackburn,
V. Bocean,
D. Bogert,
A. Bolshakova,
M. Bowden,
C. Bower
, et al. (235 additional authors not shown)
Abstract:
This paper reports the first measurement using the NOvA detectors of $ν_μ$ disappearance in a $ν_μ$ beam. The analysis uses a 14 kton-equivalent exposure of $2.74 \times 10^{20}$ protons-on-target from the Fermilab NuMI beam. Assuming the normal neutrino mass hierarchy, we measure $Δm^{2}_{32}=(2.52^{+0.20}_{-0.18})\times 10^{-3}$ eV$^{2}$ and $\sin^2θ_{23}$ in the range 0.38-0.65, both at the 68%…
▽ More
This paper reports the first measurement using the NOvA detectors of $ν_μ$ disappearance in a $ν_μ$ beam. The analysis uses a 14 kton-equivalent exposure of $2.74 \times 10^{20}$ protons-on-target from the Fermilab NuMI beam. Assuming the normal neutrino mass hierarchy, we measure $Δm^{2}_{32}=(2.52^{+0.20}_{-0.18})\times 10^{-3}$ eV$^{2}$ and $\sin^2θ_{23}$ in the range 0.38-0.65, both at the 68% confidence level, with two statistically-degenerate best fit points at $\sin^2θ_{23} = $ 0.43 and 0.60. Results for the inverted mass hierarchy are also presented.
△ Less
Submitted 20 January, 2016; v1 submitted 19 January, 2016;
originally announced January 2016.
-
First measurement of electron neutrino appearance in NOvA
Authors:
P. Adamson,
C. Ader,
M. Andrews,
N. Anfimov,
I. Anghel,
K. Arms,
E. Arrieta-Diaz,
A. Aurisano,
D. S. Ayres,
C. Backhouse,
M. Baird,
B. A. Bambah,
K. Bays,
R. Bernstein,
M. Betancourt,
V. Bhatnagar,
B. Bhuyan,
J. Bian,
K. Biery,
T. Blackburn,
V. Bocean,
D. Bogert,
A. Bolshakova,
M. Bowden,
C. Bower
, et al. (235 additional authors not shown)
Abstract:
We report results from the first search for $ν_μ\toν_e$ transitions by the NOvA experiment. In an exposure equivalent to $2.74\times10^{20}$ protons-on-target in the upgraded NuMI beam at Fermilab, we observe 6 events in the Far Detector, compared to a background expectation of $0.99\pm0.11$ (syst.) events based on the Near Detector measurement. A secondary analysis observes 11 events with a backg…
▽ More
We report results from the first search for $ν_μ\toν_e$ transitions by the NOvA experiment. In an exposure equivalent to $2.74\times10^{20}$ protons-on-target in the upgraded NuMI beam at Fermilab, we observe 6 events in the Far Detector, compared to a background expectation of $0.99\pm0.11$ (syst.) events based on the Near Detector measurement. A secondary analysis observes 11 events with a background of $1.07\pm0.14$ (syst.). The $3.3σ$ excess of events observed in the primary analysis disfavors $0.1π< δ_{CP} < 0.5π$ in the inverted mass hierarchy at the 90% C.L.
△ Less
Submitted 2 May, 2016; v1 submitted 19 January, 2016;
originally announced January 2016.
-
The NuMI Neutrino Beam
Authors:
P. Adamson,
K. Anderson,
M. Andrews,
R. Andrews,
I. Anghel,
D. Augustine,
A. Aurisano,
S. Avvakumov,
D. S. Ayres,
B. Baller,
B. Barish,
G. Barr,
W. L. Barrett,
R. H. Bernstein,
J. Biggs,
M. Bishai,
A. Blake,
V. Bocean,
G. J. Bock,
D. J. Boehnlein,
D. Bogert,
K. Bourkland,
S. V. Cao,
C. M. Castromonte,
S. Childress
, et al. (165 additional authors not shown)
Abstract:
This paper describes the hardware and operations of the Neutrinos at the Main Injector (NuMI) beam at Fermilab. It elaborates on the design considerations for the beam as a whole and for individual elements. The most important design details of individual components are described. Beam monitoring systems and procedures, including the tuning and alignment of the beam and NuMI long-term performance,…
▽ More
This paper describes the hardware and operations of the Neutrinos at the Main Injector (NuMI) beam at Fermilab. It elaborates on the design considerations for the beam as a whole and for individual elements. The most important design details of individual components are described. Beam monitoring systems and procedures, including the tuning and alignment of the beam and NuMI long-term performance, are also discussed.
△ Less
Submitted 29 July, 2015; v1 submitted 23 July, 2015;
originally announced July 2015.
-
Comparisons of the MINOS Near and Far Detector Readout Systems at a Test Beam
Authors:
A. Cabrera,
P. Adamson,
M. Barker,
A. Belias,
S. Boyd,
G. Crone,
G. Drake,
E. Falk,
P. G. Harris,
J. Hartnell,
L. Jenner,
M. Kordosky,
K. Lang,
R. P. Litchfield,
D. Michael,
P. S. Miyagawa,
R. Morse,
S. Murgia,
R. Nichol,
T. Nicholls,
G. F. Pearce,
D. Petyt,
D. Reyna,
R. Saakyan,
P. Shanahan
, et al. (6 additional authors not shown)
Abstract:
MINOS is a long baseline neutrino oscillation experiment that uses two detectors separated by 734 km. The readout systems used for the two detectors are different and have to be independently calibrated. To verify and make a direct comparison of the calibrated response of the two readout systems, test beam data were acquired using a smaller calibration detector. This detector was simultaneously in…
▽ More
MINOS is a long baseline neutrino oscillation experiment that uses two detectors separated by 734 km. The readout systems used for the two detectors are different and have to be independently calibrated. To verify and make a direct comparison of the calibrated response of the two readout systems, test beam data were acquired using a smaller calibration detector. This detector was simultaneously instrumented with both readout systems and exposed to the CERN PS T7 test beam. Differences in the calibrated response of the two systems are shown to arise from differences in response non-linearity, photomultiplier crosstalk, and threshold effects at the few percent level. These differences are reproduced by the Monte Carlo (MC) simulation to better than 1% and a scheme that corrects for these differences by calibrating the MC to match the data in each detector separately is presented. The overall difference in calorimetric response between the two readout systems is shown to be consistent with zero to a precision of 1.3% in data and 0.3% in MC with no significant energy dependence.
△ Less
Submitted 20 September, 2011; v1 submitted 6 February, 2009;
originally announced February 2009.
-
The magnetized steel and scintillator calorimeters of the MINOS experiment
Authors:
MINOS Collaboration,
D. G. Michael
Abstract:
The Main Injector Neutrino Oscillation Search (MINOS) experiment uses an accelerator-produced neutrino beam to perform precision measurements of the neutrino oscillation parameters in the "atmospheric neutrino" sector associated with muon neutrino disappearance. This long-baseline experiment measures neutrino interactions in Fermilab's NuMI neutrino beam with a near detector at Fermilab and agai…
▽ More
The Main Injector Neutrino Oscillation Search (MINOS) experiment uses an accelerator-produced neutrino beam to perform precision measurements of the neutrino oscillation parameters in the "atmospheric neutrino" sector associated with muon neutrino disappearance. This long-baseline experiment measures neutrino interactions in Fermilab's NuMI neutrino beam with a near detector at Fermilab and again 735 km downstream with a far detector in the Soudan Underground Laboratory in northern Minnesota. The two detectors are magnetized steel-scintillator tracking calorimeters. They are designed to be as similar as possible in order to ensure that differences in detector response have minimal impact on the comparisons of event rates, energy spectra and topologies that are essential to MINOS measurements of oscillation parameters. The design, construction, calibration and performance of the far and near detectors are described in this paper.
△ Less
Submitted 1 August, 2008; v1 submitted 20 May, 2008;
originally announced May 2008.
-
Performance of Hamamatsu 64-anode photomultipliers for use with wavelength--shifting optical fibres
Authors:
N. Tagg,
A. De Santo,
A. Weber,
A. Cabrera,
P. S. Miyagawa,
M. A. Barker,
K. Lang,
D. Michael,
R. Saakyan,
J. Thomas
Abstract:
Hamamatsu R5900-00-M64 and R7600-00-M64 photomultiplier tubes will be used with wavelength--shifting optical fibres to read out scintillator strips in the MINOS near detector. We report on measurements of the gain, efficiency, linearity, crosstalk, and dark noise of 232 of these PMTs, of which 219 met MINOS requirements.
Hamamatsu R5900-00-M64 and R7600-00-M64 photomultiplier tubes will be used with wavelength--shifting optical fibres to read out scintillator strips in the MINOS near detector. We report on measurements of the gain, efficiency, linearity, crosstalk, and dark noise of 232 of these PMTs, of which 219 met MINOS requirements.
△ Less
Submitted 26 October, 2004; v1 submitted 12 August, 2004;
originally announced August 2004.