-
Performance of the electromagnetic and hadronic prototype segments of the ALICE Forward Calorimeter
Authors:
M. Aehle,
J. Alme,
C. Arata,
I. Arsene,
I. Bearden,
T. Bodova,
V. Borshchov,
O. Bourrion,
M. Bregant,
A. van den Brink,
V. Buchakchiev,
A. Buhl,
T. Chujo,
L. Dufke,
V. Eikeland,
M. Fasel,
N. Gauger,
A. Gautam,
A. Ghimouz,
Y. Goto,
R. Guernane,
T. Hachiya,
H. Hassan,
L. He,
H. Helstrup
, et al. (52 additional authors not shown)
Abstract:
We present the performance of a full-length prototype of the ALICE Forward Calorimeter (FoCal). The detector is composed of a silicon-tungsten electromagnetic sampling calorimeter with longitudinal and transverse segmentation (FoCal-E) of about 20$X_0$ and a hadronic copper-scintillating-fiber calorimeter (FoCal-H) of about 5$λ_{\rm int}$. The data were taken between 2021 and 2023 at the CERN PS a…
▽ More
We present the performance of a full-length prototype of the ALICE Forward Calorimeter (FoCal). The detector is composed of a silicon-tungsten electromagnetic sampling calorimeter with longitudinal and transverse segmentation (FoCal-E) of about 20$X_0$ and a hadronic copper-scintillating-fiber calorimeter (FoCal-H) of about 5$λ_{\rm int}$. The data were taken between 2021 and 2023 at the CERN PS and SPS beam lines with hadron (electron) beams up to energies of 350 (300) GeV. Regarding FoCal-E, we report a comprehensive analysis of its response to minimum ionizing particles across all pad layers. The longitudinal shower profile of electromagnetic showers is measured with a layer-wise segmentation of 1$X_0$. As a projection to the performance of the final detector in electromagnetic showers, we demonstrate linearity in the full energy range, and show that the energy resolution fulfills the requirements for the physics needs. Additionally, the performance to separate two-showers events was studied by quantifying the transverse shower width. Regarding FoCal-H, we report a detailed analysis of the response to hadron beams between 60 and 350 GeV. The results are compared to simulations obtained with a Geant4 model of the test beam setup, which in particular for FoCal-E are in good agreement with the data. The energy resolution of FoCal-E was found to be lower than 3% at energies larger than 100 GeV. The response of FoCal-H to hadron beams was found to be linear, albeit with a significant intercept that is about factor 2 larger than in simulations. Its resolution, which is non-Gaussian and generally larger than in simulations, was quantified using the FWHM, and decreases from about 16% at 100 GeV to about 11% at 350 GeV. The discrepancy to simulations, which is particularly evident at low hadron energies, needs to be further investigated.
△ Less
Submitted 16 July, 2024; v1 submitted 13 November, 2023;
originally announced November 2023.
-
A Large-Scale Pad-Sensor Based Prototype of the Silicon Tungsten Electromagnetic Calorimeter for the Forward Direction in ALICE at LHC
Authors:
R. G. E. Barthel,
T. Chujo,
T. Hachiya,
M. Hatakeyama,
Y. Hoshi,
M. Inaba,
Y.,
Kawamura,
D. Kawana,
C. Loizides,
Y. Miake,
Y. Minato,
K. Nakagawa,
N. Novitzky,
T. Peitzmann,
M. Rossewij,
M. Shimomura,
T. Sugitate,
T. Suzuki,
K. Tadokoro,
M. Takamura,
S. Takasu,
A. van den Brink,
M. van Leeuwen
Abstract:
We constructed a large-scale electromagnetic calorimeter prototype as a part of the Forward Calorimeter upgrade project (FoCal) for the ALICE experiment at the Large Hadron Collider (LHC). The prototype, also known as ``Mini FoCal'', consists of 20 layers of silicon pad sensors and tungsten alloy plates with printed circuit boards and readout electronics. The constructed detector was tested at the…
▽ More
We constructed a large-scale electromagnetic calorimeter prototype as a part of the Forward Calorimeter upgrade project (FoCal) for the ALICE experiment at the Large Hadron Collider (LHC). The prototype, also known as ``Mini FoCal'', consists of 20 layers of silicon pad sensors and tungsten alloy plates with printed circuit boards and readout electronics. The constructed detector was tested at the test beam facility of the Super Proton Synchrotron (SPS) at CERN. We obtain an energy resolution of about 4.3% for electron beams at both 150 and 250 GeV/$c$, which is consistent with realistic detector response simulations. Longitudinal profiles of electromagnetic shower were also measured and found to agree with the simulations. The same prototype detector was installed in the ALICE experimental area about 7.5m away from the interaction point. It was used to measure inclusive electromagnetic cluster energy distributions and neutral-pion candidate invariant mass distributions for pseudo-rapidity of $η$=3.7-4.5 in proton-proton collisions at $\sqrt{s}$ = 13 TeV at LHC. The measured distributions in different $η$ regions are similar to those obtained from PYTHIA simulations.
△ Less
Submitted 18 March, 2024; v1 submitted 9 June, 2023;
originally announced June 2023.
-
Design and Performance of a Silicon Tungsten Calorimeter Prototype Module and the Associated Readout
Authors:
T. Awes,
C. L. Britton,
T. Chujo,
T. Cormier,
M. N. Ericson,
N. B. Ezell,
D. Fehlker,
S. S. Frank,
Y. Fukuda,
T. Gunji,
T. Hachiya,
H. Hamagaki,
S. Hayashi,
M. Hirano,
R. Hosokawa,
M. Inaba,
K. Ito,
Y. Kawamura,
D. Kawana,
B. Kim,
S. Kudo,
C. Loizides,
Y. Miake,
G. Nooren,
N. Novitzky
, et al. (19 additional authors not shown)
Abstract:
We describe the details of a silicon-tungsten prototype electromagnetic calorimeter module and associated readout electronics. Detector performance for this prototype has been measured in test beam experiments at the CERN PS and SPS accelerator facilities in 2015/16. The results are compared to those in Monte Carlo Geant4 simulations. This is the first real-world demonstration of the performance o…
▽ More
We describe the details of a silicon-tungsten prototype electromagnetic calorimeter module and associated readout electronics. Detector performance for this prototype has been measured in test beam experiments at the CERN PS and SPS accelerator facilities in 2015/16. The results are compared to those in Monte Carlo Geant4 simulations. This is the first real-world demonstration of the performance of a custom ASIC designed for fast, lower-power, high-granularity applications.
△ Less
Submitted 9 December, 2020; v1 submitted 23 December, 2019;
originally announced December 2019.
-
A self-injected, diode-pumped, solid-state ring laser for laser cooling of Li atoms
Authors:
Yudai Miake,
Takashi Mukaiyama,
Kenneth M. O'Hara,
Stephen Gensemer
Abstract:
We have constructed a solid-state light source for experiments with laser cooled lithium atoms based on a Nd:YVO$_4$ ring laser with second-harmonic generation. Unidirectional lasing, an improved mode selection, and a high output power of the ring laser was achieved by weak coupling to an external cavity which contained the lossy elements required for single frequency operation. Continuous frequen…
▽ More
We have constructed a solid-state light source for experiments with laser cooled lithium atoms based on a Nd:YVO$_4$ ring laser with second-harmonic generation. Unidirectional lasing, an improved mode selection, and a high output power of the ring laser was achieved by weak coupling to an external cavity which contained the lossy elements required for single frequency operation. Continuous frequency tuning is accomplished by controlling two PZTs in the internal and the external cavities simultaneously. The light source has been utilized to trap and cool fermionic lithium atoms into the quantum degenerate regime.
△ Less
Submitted 9 April, 2015;
originally announced April 2015.