The JUNO experiment Top Tracker
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato
, et al. (592 additional authors not shown)
Abstract:
The main task of the Top Tracker detector of the neutrino reactor experiment Jiangmen Underground Neutrino Observatory (JUNO) is to reconstruct and extrapolate atmospheric muon tracks down to the central detector. This muon tracker will help to evaluate the contribution of the cosmogenic background to the signal. The Top Tracker is located above JUNO's water Cherenkov Detector and Central Detector…
▽ More
The main task of the Top Tracker detector of the neutrino reactor experiment Jiangmen Underground Neutrino Observatory (JUNO) is to reconstruct and extrapolate atmospheric muon tracks down to the central detector. This muon tracker will help to evaluate the contribution of the cosmogenic background to the signal. The Top Tracker is located above JUNO's water Cherenkov Detector and Central Detector, covering about 60% of the surface above them. The JUNO Top Tracker is constituted by the decommissioned OPERA experiment Target Tracker modules. The technology used consists in walls of two planes of plastic scintillator strips, one per transverse direction. Wavelength shifting fibres collect the light signal emitted by the scintillator strips and guide it to both ends where it is read by multianode photomultiplier tubes. Compared to the OPERA Target Tracker, the JUNO Top Tracker uses new electronics able to cope with the high rate produced by the high rock radioactivity compared to the one in Gran Sasso underground laboratory. This paper will present the new electronics and mechanical structure developed for the Top Tracker of JUNO along with its expected performance based on the current detector simulation.
△ Less
Submitted 9 March, 2023;
originally announced March 2023.
-
JUNO sensitivity to $^7$Be, $pep$, and CNO solar neutrinos
Authors:
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Marco Beretta
, et al. (592 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory (JUNO), the first multi-kton liquid scintillator detector, which is under construction in China, will have a unique potential to perform a real-time measurement of solar neutrinos well below the few MeV threshold typical for Water Cherenkov detectors. JUNO's large target mass and excellent energy resolution are prerequisites for reaching unprecedented…
▽ More
The Jiangmen Underground Neutrino Observatory (JUNO), the first multi-kton liquid scintillator detector, which is under construction in China, will have a unique potential to perform a real-time measurement of solar neutrinos well below the few MeV threshold typical for Water Cherenkov detectors. JUNO's large target mass and excellent energy resolution are prerequisites for reaching unprecedented levels of precision. In this paper, we provide estimation of the JUNO sensitivity to 7Be, pep, and CNO solar neutrinos that can be obtained via a spectral analysis above the 0.45 MeV threshold. This study is performed assuming different scenarios of the liquid scintillator radiopurity, ranging from the most opti mistic one corresponding to the radiopurity levels obtained by the Borexino experiment, up to the minimum requirements needed to perform the neutrino mass ordering determination with reactor antineutrinos - the main goal of JUNO. Our study shows that in most scenarios, JUNO will be able to improve the current best measurements on 7Be, pep, and CNO solar neutrino fluxes. We also perform a study on the JUNO capability to detect periodical time variations in the solar neutrino flux, such as the day-night modulation induced by neutrino flavor regeneration in Earth, and the modulations induced by temperature changes driven by helioseismic waves.
△ Less
Submitted 7 March, 2023;
originally announced March 2023.
-
Prospects for Detecting the Diffuse Supernova Neutrino Background with JUNO
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld,
Sylvie Blin
, et al. (577 additional authors not shown)
Abstract:
We present the detection potential for the diffuse supernova neutrino background (DSNB) at the Jiangmen Underground Neutrino Observatory (JUNO), using the inverse-beta-decay (IBD) detection channel on free protons. We employ the latest information on the DSNB flux predictions, and investigate in detail the background and its reduction for the DSNB search at JUNO. The atmospheric neutrino induced n…
▽ More
We present the detection potential for the diffuse supernova neutrino background (DSNB) at the Jiangmen Underground Neutrino Observatory (JUNO), using the inverse-beta-decay (IBD) detection channel on free protons. We employ the latest information on the DSNB flux predictions, and investigate in detail the background and its reduction for the DSNB search at JUNO. The atmospheric neutrino induced neutral current (NC) background turns out to be the most critical background, whose uncertainty is carefully evaluated from both the spread of model predictions and an envisaged \textit{in situ} measurement. We also make a careful study on the background suppression with the pulse shape discrimination (PSD) and triple coincidence (TC) cuts. With latest DSNB signal predictions, more realistic background evaluation and PSD efficiency optimization, and additional TC cut, JUNO can reach the significance of 3$σ$ for 3 years of data taking, and achieve better than 5$σ$ after 10 years for a reference DSNB model. In the pessimistic scenario of non-observation, JUNO would strongly improve the limits and exclude a significant region of the model parameter space.
△ Less
Submitted 13 October, 2022; v1 submitted 18 May, 2022;
originally announced May 2022.
-
Mass Testing and Characterization of 20-inch PMTs for JUNO
Authors:
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
Joao Pedro Athayde Marcondes de Andre,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli
, et al. (541 additional authors not shown)
Abstract:
Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program whic…
▽ More
Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program which began in 2017 and elapsed for about four years. Based on this mass characterization and a set of specific requirements, a good quality of all accepted PMTs could be ascertained. This paper presents the performed testing procedure with the designed testing systems as well as the statistical characteristics of all 20-inch PMTs intended to be used in the JUNO experiment, covering more than fifteen performance parameters including the photocathode uniformity. This constitutes the largest sample of 20-inch PMTs ever produced and studied in detail to date, i.e. 15,000 of the newly developed 20-inch MCP-PMTs from Northern Night Vision Technology Co. (NNVT) and 5,000 of dynode PMTs from Hamamatsu Photonics K. K.(HPK).
△ Less
Submitted 17 September, 2022; v1 submitted 17 May, 2022;
originally announced May 2022.
-
Potential for a precision measurement of solar $pp$ neutrinos in the Serappis Experiment
Authors:
Lukas Bieger,
Thilo Birkenfeld,
David Blum,
Wilfried Depnering,
Timo Enqvist,
Heike Enzmann,
Feng Gao,
Christoph Genster,
Alexandre Göttel,
Christian Grewing,
Maxim Gromov,
Paul Hackspacher,
Caren Hagner,
Tobias Heinz,
Philipp Kampmann,
Michael Karagounis,
Andre Kruth,
Pasi Kuusiniemi,
Tobias Lachenmaier,
Daniel Liebau,
Runxuan Liu,
Kai Loo,
Livia Ludhova,
David Meyhöfer,
Axel Müller
, et al. (34 additional authors not shown)
Abstract:
The Serappis (SEarch for RAre PP-neutrinos In Scintillator) project aims at a precision measurement of the flux of solar $pp$ neutrinos on the few-percent level. Such a measurement will be a relevant contribution to the study of solar neutrino oscillation parameters and a sensitive test of the solar luminosity constraint. The concept of Serappis relies on a small organic liquid scintillator detect…
▽ More
The Serappis (SEarch for RAre PP-neutrinos In Scintillator) project aims at a precision measurement of the flux of solar $pp$ neutrinos on the few-percent level. Such a measurement will be a relevant contribution to the study of solar neutrino oscillation parameters and a sensitive test of the solar luminosity constraint. The concept of Serappis relies on a small organic liquid scintillator detector ($\sim$20 m$^3$) with excellent energy resolution ($\sim$2.5 % at 1 MeV), low internal background and sufficient shielding from surrounding radioactivity. This can be achieved by a minor upgrade of the OSIRIS facility at the site of the JUNO neutrino experiment in southern China. To go substantially beyond current accuracy levels for the $pp$ flux, an organic scintillator with ultra-low $^{14}$C levels (below $10^{-18}$) is required. The existing OSIRIS detector and JUNO infrastructure will be instrumental in identifying suitable scintillator materials, offering a unique chance for a low-budget high-precision measurement of a fundamental property of our Sun that will be otherwise hard to access.
△ Less
Submitted 18 July, 2022; v1 submitted 22 September, 2021;
originally announced September 2021.
-
Radioactivity control strategy for the JUNO detector
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld,
Sylvie Blin
, et al. (578 additional authors not shown)
Abstract:
JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day, therefore a careful control of the background sources due to radioactivity is critical. In particula…
▽ More
JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day, therefore a careful control of the background sources due to radioactivity is critical. In particular, natural radioactivity present in all materials and in the environment represents a serious issue that could impair the sensitivity of the experiment if appropriate countermeasures were not foreseen. In this paper we discuss the background reduction strategies undertaken by the JUNO collaboration to reduce at minimum the impact of natural radioactivity. We describe our efforts for an optimized experimental design, a careful material screening and accurate detector production handling, and a constant control of the expected results through a meticulous Monte Carlo simulation program. We show that all these actions should allow us to keep the background count rate safely below the target value of 10 Hz in the default fiducial volume, above an energy threshold of 0.7 MeV.
△ Less
Submitted 13 October, 2021; v1 submitted 8 July, 2021;
originally announced July 2021.
-
The Design and Sensitivity of JUNO's scintillator radiopurity pre-detector OSIRIS
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld
, et al. (582 additional authors not shown)
Abstract:
The OSIRIS detector is a subsystem of the liquid scintillator fillling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator to assure that all components of the JUNO scintillator system work to specifications and only neutrino-grade scintillator is filled into the JUNO Central Detector. The aspired sensitivity level of $10^{-16}$ g/g of…
▽ More
The OSIRIS detector is a subsystem of the liquid scintillator fillling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator to assure that all components of the JUNO scintillator system work to specifications and only neutrino-grade scintillator is filled into the JUNO Central Detector. The aspired sensitivity level of $10^{-16}$ g/g of $^{238}$U and $^{232}$Th requires a large ($\sim$20 m$^3$) detection volume and ultralow background levels. The present paper reports on the design and major components of the OSIRIS detector, the detector simulation as well as the measuring strategies foreseen and the sensitivity levels to U/Th that can be reached in this setup.
△ Less
Submitted 31 March, 2021;
originally announced March 2021.
-
A container-based facility for testing 20'000 20-inch PMTs for JUNO
Authors:
Björn Wonsak,
Alexander Tietzsch,
Tobias Sterr,
Tobias Lachenmaier,
Nikolay Anfimov,
David Blum,
Caren Hagner,
Benedict Kaiser,
David Meyhöfer,
Alexander Olshevskiy,
Zhonghua Qin,
Henning Rebber,
Simon Reichert,
Malte Stender,
Wei Wang,
Zhimin Wang
Abstract:
The main goal of the JUNO experiment is the determination of the neutrino mass ordering. To achieve this, an extraordinary energy resolution of at least $3\,\%$ at $1\,$MeV is required for which all parts of the JUNO detector need to meet certain quality criteria. This is relevant in particular for those which are related to the energy resolution of the detector, such as the photomultiplier tubes…
▽ More
The main goal of the JUNO experiment is the determination of the neutrino mass ordering. To achieve this, an extraordinary energy resolution of at least $3\,\%$ at $1\,$MeV is required for which all parts of the JUNO detector need to meet certain quality criteria. This is relevant in particular for those which are related to the energy resolution of the detector, such as the photomultiplier tubes (PMTs) to be deployed in JUNO. This paper presents the setup and performance of a dedicated PMT mass testing facility to examine and characterize the performance of the 20-inch JUNO PMTs. Its quasi-industrial size and operation level allows to test all 20000 PMTs intended to be used in the JUNO experiment. With this PMT mass testing system, several key characteristics like dark count rate, peak-to-valley ratio, photon detection efficiency, and timing resolution have been determined at an operating gain of $1\times10^7$ and assessed with respect to the requirements of JUNO. Measurement conditions and modes for the PMTs as well as estimated accuracies for the determination of the individual PMT parameters with the system are presented as well.
△ Less
Submitted 14 May, 2021; v1 submitted 18 March, 2021;
originally announced March 2021.
-
Calibration Strategy of the JUNO Experiment
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
Thilo Birkenfeld
, et al. (571 additional authors not shown)
Abstract:
We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector ca…
▽ More
We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector can achieve a better than 1% energy linearity and a 3% effective energy resolution, required by the neutrino mass ordering determination.
△ Less
Submitted 20 January, 2021; v1 submitted 12 November, 2020;
originally announced November 2020.
-
Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector
Authors:
Daya Bay,
JUNO collaborations,
:,
A. Abusleme,
T. Adam,
S. Ahmad,
S. Aiello,
M. Akram,
N. Ali,
F. P. An,
G. P. An,
Q. An,
G. Andronico,
N. Anfimov,
V. Antonelli,
T. Antoshkina,
B. Asavapibhop,
J. P. A. M. de André,
A. Babic,
A. B. Balantekin,
W. Baldini,
M. Baldoncini,
H. R. Band,
A. Barresi,
E. Baussan
, et al. (642 additional authors not shown)
Abstract:
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were…
▽ More
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and <0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. To bridge the one order of magnitude in the detector size difference between Daya Bay and JUNO, the Daya Bay data were used to tune the parameters of a newly developed optical model. Then, the model and tuned parameters were used in the JUNO simulation. This enabled to determine the optimal composition for the JUNO LS: purified solvent LAB with 2.5 g/L PPO, and 1 to 4 mg/L bis-MSB.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
-
Feasibility and physics potential of detecting $^8$B solar neutrinos at JUNO
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Sebastiano Aiello,
Muhammad Akram,
Nawab Ali,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
David Biare
, et al. (572 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO's features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid s…
▽ More
The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO's features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid scintillator detectors. In this paper we present a comprehensive assessment of JUNO's potential for detecting $^8$B solar neutrinos via the neutrino-electron elastic scattering process. A reduced 2~MeV threshold on the recoil electron energy is found to be achievable assuming the intrinsic radioactive background $^{238}$U and $^{232}$Th in the liquid scintillator can be controlled to 10$^{-17}$~g/g. With ten years of data taking, about 60,000 signal and 30,000 background events are expected. This large sample will enable an examination of the distortion of the recoil electron spectrum that is dominated by the neutrino flavor transformation in the dense solar matter, which will shed new light on the tension between the measured electron spectra and the predictions of the standard three-flavor neutrino oscillation framework. If $Δm^{2}_{21}=4.8\times10^{-5}~(7.5\times10^{-5})$~eV$^{2}$, JUNO can provide evidence of neutrino oscillation in the Earth at the about 3$σ$~(2$σ$) level by measuring the non-zero signal rate variation with respect to the solar zenith angle. Moveover, JUNO can simultaneously measure $Δm^2_{21}$ using $^8$B solar neutrinos to a precision of 20\% or better depending on the central value and to sub-percent precision using reactor antineutrinos. A comparison of these two measurements from the same detector will help elucidate the current tension between the value of $Δm^2_{21}$ reported by solar neutrino experiments and the KamLAND experiment.
△ Less
Submitted 21 June, 2020;
originally announced June 2020.
-
TAO Conceptual Design Report: A Precision Measurement of the Reactor Antineutrino Spectrum with Sub-percent Energy Resolution
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Sebastiano Aiello,
Muhammad Akram,
Nawab Ali,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
David Biare
, et al. (568 additional authors not shown)
Abstract:
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future re…
▽ More
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future reactor neutrino experiments, and to provide a benchmark measurement to test nuclear databases. A spherical acrylic vessel containing 2.8 ton gadolinium-doped liquid scintillator will be viewed by 10 m^2 Silicon Photomultipliers (SiPMs) of >50% photon detection efficiency with almost full coverage. The photoelectron yield is about 4500 per MeV, an order higher than any existing large-scale liquid scintillator detectors. The detector operates at -50 degree C to lower the dark noise of SiPMs to an acceptable level. The detector will measure about 2000 reactor antineutrinos per day, and is designed to be well shielded from cosmogenic backgrounds and ambient radioactivities to have about 10% background-to-signal ratio. The experiment is expected to start operation in 2022.
△ Less
Submitted 18 May, 2020;
originally announced May 2020.
-
Combined sensitivity to the neutrino mass ordering with JUNO, the IceCube Upgrade, and PINGU
Authors:
IceCube-Gen2 Collaboration,
:,
M. G. Aartsen,
M. Ackermann,
J. Adams,
J. A. Aguilar,
M. Ahlers,
M. Ahrens,
C. Alispach,
K. Andeen,
T. Anderson,
I. Ansseau,
G. Anton,
C. Argüelles,
T. C. Arlen,
J. Auffenberg,
S. Axani,
P. Backes,
H. Bagherpour,
X. Bai,
A. Balagopal V.,
A. Barbano,
I. Bartos,
S. W. Barwick,
B. Bastian
, et al. (421 additional authors not shown)
Abstract:
The ordering of the neutrino mass eigenstates is one of the fundamental open questions in neutrino physics. While current-generation neutrino oscillation experiments are able to produce moderate indications on this ordering, upcoming experiments of the next generation aim to provide conclusive evidence. In this paper we study the combined performance of the two future multi-purpose neutrino oscill…
▽ More
The ordering of the neutrino mass eigenstates is one of the fundamental open questions in neutrino physics. While current-generation neutrino oscillation experiments are able to produce moderate indications on this ordering, upcoming experiments of the next generation aim to provide conclusive evidence. In this paper we study the combined performance of the two future multi-purpose neutrino oscillation experiments JUNO and the IceCube Upgrade, which employ two very distinct and complementary routes towards the neutrino mass ordering. The approach pursued by the $20\,\mathrm{kt}$ medium-baseline reactor neutrino experiment JUNO consists of a careful investigation of the energy spectrum of oscillated $\barν_e$ produced by ten nuclear reactor cores. The IceCube Upgrade, on the other hand, which consists of seven additional densely instrumented strings deployed in the center of IceCube DeepCore, will observe large numbers of atmospheric neutrinos that have undergone oscillations affected by Earth matter. In a joint fit with both approaches, tension occurs between their preferred mass-squared differences $ Δm_{31}^{2}=m_{3}^{2}-m_{1}^{2} $ within the wrong mass ordering. In the case of JUNO and the IceCube Upgrade, this allows to exclude the wrong ordering at $>5σ$ on a timescale of 3--7 years --- even under circumstances that are unfavorable to the experiments' individual sensitivities. For PINGU, a 26-string detector array designed as a potential low-energy extension to IceCube, the inverted ordering could be excluded within 1.5 years (3 years for the normal ordering) in a joint analysis.
△ Less
Submitted 15 November, 2019;
originally announced November 2019.
-
Topological track reconstruction in unsegmented, large-volume liquid scintillator detectors
Authors:
Björn S. Wonsak,
Caren I. Hagner,
Dominikus A. Hellgartner,
Kai Loo,
Sebastian Lorenz,
David J. Meyhöfer,
Lothar Oberauer,
Henning Rebber,
Wladyslaw H. Trzaska,
Michael Wurm
Abstract:
Unsegmented, large-volume liquid scintillator (LS) neutrino detectors have proven to be a key technology for low-energy neutrino physics. The efficient rejection of radionuclide background induced by cosmic muon interactions is of paramount importance for their success in high-precision MeV neutrino measurements. We present a novel technique to reconstruct GeV particle tracks in LS, whose main pro…
▽ More
Unsegmented, large-volume liquid scintillator (LS) neutrino detectors have proven to be a key technology for low-energy neutrino physics. The efficient rejection of radionuclide background induced by cosmic muon interactions is of paramount importance for their success in high-precision MeV neutrino measurements. We present a novel technique to reconstruct GeV particle tracks in LS, whose main property, the resolution of topological features and changes in the differential energy loss $\mathrm{d}E/\mathrm{d}x$, allows for improved rejection strategies. Different to common track reconstruction approaches, our method does not rely on concrete track / topology hypotheses. Instead, based on a reference point in space and time, the observed distribution of photon arrival times at the photosensors and the detector's characteristics in terms of photon production, propagation and detection (optical model), it reconstructs the voxelized distribution of optical photon emissions. Techniques from three-dimensional data analysis can then be applied to extract parameters describing the topology, e.g., the direction of a track. We performed a first performance evaluation of our method using single muon events with up to $10\,\mathrm{GeV}$ from a Geant4 simulation of the LENA detector. The current results indicate that our approach is competitive with existing reconstruction methods -- although its full potential has not yet been exploited. We also remark on other detector technologies in astroparticle physics as well as applications in medical imaging that could benefit from the fundamental ideas of our method.
△ Less
Submitted 19 June, 2018; v1 submitted 23 March, 2018;
originally announced March 2018.