-
Wafer-level fabrication of all-dielectric vapor cells enabling optically addressed Rydberg atom electrometry
Authors:
Alexandra B. Artusio-Glimpse,
Adil Meraki,
Hunter Shillingburg,
Guy Lavallee,
Miao Liu,
Chad Eichfeld,
Matthew T. Simons,
Glenn Holland,
Christopher L. Holloway,
Vladimir A. Aksyuk,
Daniel Lopez
Abstract:
Rydberg-atom electrometry enables highly sensitive electric-field measurements by exploiting the extreme polarizability of Rydberg states in alkali atoms. Millimeter-scale atomic vapor cells can be accurately and economically batch-fabricated by anodically bonding silicon and glass wafers, enabling the large-volume manufacturing of miniature atomic clocks and quantum sensors. However, silicon is n…
▽ More
Rydberg-atom electrometry enables highly sensitive electric-field measurements by exploiting the extreme polarizability of Rydberg states in alkali atoms. Millimeter-scale atomic vapor cells can be accurately and economically batch-fabricated by anodically bonding silicon and glass wafers, enabling the large-volume manufacturing of miniature atomic clocks and quantum sensors. However, silicon is not always an ideal constitutive material for electric-field sensing because of its high dielectric constant and conductive losses at millimeter wave frequencies. A broader selection of low-loss all-dielectric alternatives may be beneficial for specific applications. Here, we present an all-glass wafer-level microfabrication process that eliminates silicon, creating hermetically sealed vapor cells that are stable over long timelines with embedded cesium dispensers. Femtosecond laser machining precisely defines the cell geometry, and laser-activated alkali loading ensures reliable filling. We demonstrate long-term vacuum stability and robust Rydberg excitation through electromagnetically induced transparency measurements of several Rydberg states. We then use these cells to measure a 34 GHz millimeter wave field resonant with the 58D$_{5/2}\rightarrow$60P$_{3/2}$ transition using Autler-Townes splitting showing expected linear dependence with field strength. This work demonstrates that the all-glass approach offers a highly durable low-loss cell alternative for miniaturized millimeter wave and microwave quantum sensing, with the potential to flexibly incorporate a range of other dielectric and semiconductor materials and integrated photonic and electronic technologies.
△ Less
Submitted 17 April, 2025; v1 submitted 19 March, 2025;
originally announced March 2025.
-
Primary quantum thermometry of mm-wave blackbody radiation via induced state transfer in Rydberg states of cold atoms
Authors:
Noah Schlossberger,
Andrew P. Rotunno,
Stephen P. Eckel,
Eric B. Norrgard,
Dixith Manchaiah,
Nikunjkumar Prajapati,
Alexandra B. Artusio-Glimpse,
Samuel Berweger,
Matthew T. Simons,
Dangka Shylla,
William J. Watterson,
Charles Patrick,
Adil Meraki,
Rajavardhan Talashila,
Amanda Younes,
David S. La Mantia,
Christopher L. Holloway
Abstract:
Rydberg states of alkali atoms are highly sensitive to electromagnetic radiation in the GHz-to-THz regime because their transitions have large electric dipole moments. Consequently, environmental blackbody radiation (BBR) can couple Rydberg states together at $μ$s timescales. Here, we track the BBR-induced transfer of a prepared Rydberg state to its neighbors and use the evolution of these state p…
▽ More
Rydberg states of alkali atoms are highly sensitive to electromagnetic radiation in the GHz-to-THz regime because their transitions have large electric dipole moments. Consequently, environmental blackbody radiation (BBR) can couple Rydberg states together at $μ$s timescales. Here, we track the BBR-induced transfer of a prepared Rydberg state to its neighbors and use the evolution of these state populations to characterize the BBR field at the relevant wavelengths, primarily at 130 GHz. We use selective field ionization readout of Rydberg states with principal quantum number $n\sim30$ in $^{85}$Rb and substantiate our ionization signal with a theoretical model. With this detection method, we measure the associated blackbody-radiation-induced time dynamics of these states, reproduce the results with a simple semi-classical population transfer model, and demonstrate that this measurement is temperature sensitive with a statistical sensitivity to the fractional temperature uncertainty of 0.09 Hz$^{-1/2}$, corresponding to 26 K$\cdot$Hz$^{-1/2}$ at room temperature. This represents a calibration-free SI-traceable temperature measurement, for which we calculate a systematic fractional temperature uncertainty of 0.006, corresponding to 2 K at room temperature when used as a primary temperature standard.
△ Less
Submitted 15 October, 2024; v1 submitted 15 October, 2024;
originally announced October 2024.
-
Optimized detection modality for double resonance alignment based optical magnetometer
Authors:
A. Akbar,
M. Kozbiál,
L. Elson,
A. Meraki,
J. Kolodyński,
K. Jensen
Abstract:
In this work, we present a comprehensive and comparative analysis of two detection modalities, i.e., polarization rotation and absorption measurement of light, for a double resonance alignment based optical magnetometer (DRAM). We derive algebraic expressions for magnetometry signals based on multipole moments description. Experiments are carried out using a room-temperature paraffin-coated Caesiu…
▽ More
In this work, we present a comprehensive and comparative analysis of two detection modalities, i.e., polarization rotation and absorption measurement of light, for a double resonance alignment based optical magnetometer (DRAM). We derive algebraic expressions for magnetometry signals based on multipole moments description. Experiments are carried out using a room-temperature paraffin-coated Caesium vapour cell and measuring either the polarization rotation or absorption of the transmitted laser light. A detailed experimental analysis of the resonance spectra is performed to validate the theoretical findings for various input parameters. The results signify the use of a single isotropic relaxation rate thus simplifying the data analysis for optimization of the DRAM. The sensitivity measurements are performed and reveal that the polarization rotation detection mode yields larger signals and better sensitivity than absorption measurement of light.
△ Less
Submitted 8 March, 2024;
originally announced March 2024.
-
Spin noise spectroscopy of an alignment-based atomic magnetometer
Authors:
Marcin Kozbial,
Lucy Elson,
Lucas M. Rushton,
Ali Akbar,
Adil Meraki,
Kasper Jensen,
Jan Kolodynski
Abstract:
Optically pumped magnetometers (OPMs) are revolutionising the task of magnetic-field sensing due to their extremely high sensitivity combined with technological improvements in miniaturisation which have led to compact and portable devices. OPMs can be based on spin-oriented or spin-aligned atomic ensembles which are spin-polarized through optical pumping with circular or linear polarized light, r…
▽ More
Optically pumped magnetometers (OPMs) are revolutionising the task of magnetic-field sensing due to their extremely high sensitivity combined with technological improvements in miniaturisation which have led to compact and portable devices. OPMs can be based on spin-oriented or spin-aligned atomic ensembles which are spin-polarized through optical pumping with circular or linear polarized light, respectively. Characterisation of OPMs and the dynamical properties of their noise is important for applications in real-time sensing tasks. In our work, we experimentally perform spin noise spectroscopy of an alignment-based magnetometer. Moreover, we propose a stochastic model that predicts the noise power spectra exhibited by the device when, apart from the strong magnetic field responsible for the Larmor precession of the spin, white noise is applied in the perpendicular direction aligned with the pumping-probing beam. By varying the strength of the noise applied as well as the linear-polarisation angle of incoming light, we verify the model to accurately predict the heights of the Larmor-induced spectral peaks and their corresponding line-widths. Our work paves the way for alignment-based magnetometers to become operational in real-time sensing tasks.
△ Less
Submitted 30 July, 2024; v1 submitted 9 December, 2023;
originally announced December 2023.
-
Zero-field optical magnetometer based on spin-alignment
Authors:
Adil Meraki,
Lucy Elson,
Nok Ho,
Ali Akbar,
Marcin Koźbiał,
Jan Kołodyński,
Kasper Jensen
Abstract:
Optically-pumped magnetometers are an important instrument for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-al…
▽ More
Optically-pumped magnetometers are an important instrument for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-aligned atomic ensemble for magnetometry at zero-field. A novel approach is introduced, which involves evaluating how the linear polarization of light rotates as it passes through the atomic vapor to null the magnetic field. Analytical expressions are derived for the resulting spin alignment and photodetection signals. Experimental results are provided, demonstrating good agreement with the theoretical predictions. The sensitivity and bandwidth of the magnetometer are characterized based on the detected polarization rotation signal. Lastly, the practical utility of the magnetometer for medical applications is demonstrated by successfully detecting a synthetic cardiac signal.
△ Less
Submitted 23 August, 2023;
originally announced August 2023.
-
Alignment-based optically pumped magnetometer using a buffer gas cell
Authors:
L. M. Rushton,
L. Elson,
A. Meraki,
K. Jensen
Abstract:
Alignment-based optically pumped magnetometers (OPMs) are capable of measuring oscillating magnetic fields with high sensitivity in the fT/sqrt(Hz) range. Until now, alignment-based magnetometers have only used paraffin-coated vapour cells to extend the spin relaxation lifetimes of the alkali vapour. The drawback of these cells is that they are hand-blown and are therefore time-intensive, and some…
▽ More
Alignment-based optically pumped magnetometers (OPMs) are capable of measuring oscillating magnetic fields with high sensitivity in the fT/sqrt(Hz) range. Until now, alignment-based magnetometers have only used paraffin-coated vapour cells to extend the spin relaxation lifetimes of the alkali vapour. The drawback of these cells is that they are hand-blown and are therefore time-intensive, and somewhat unreliable, to produce. Buffer gas cells, on the other hand, can be manufactured on a mass scale using microfabrication techniques. We present the first demonstration of an alignment-based magnetometer using a buffer gas vapour cell containing caesium (Cs) alkali vapour and nitrogen (N2) buffer gas. The OPM is operated at 55 degrees C and we achieve a 325 fT/sqrt(Hz) sensitivity to 10 kHz oscillating magnetic fields with an 800 Hz bandwidth. The alignment-based magnetometer uses a single laser beam for optical pumping and probing and could potentially allow for more rapid commercialisation of radio-frequency OPMs, due to the robustness of the one-beam geometry and the potential for mass-scale microfabrication of buffer gas cells.
△ Less
Submitted 18 January, 2023;
originally announced January 2023.
-
Detection and characterisation of conductive objects using electromagnetic induction and a fluxgate magnetometer
Authors:
Lucy Elson,
Adil Meraki,
Lucas M. Rushton,
Tadas Pyragius,
Kasper Jensen
Abstract:
Eddy currents induced in electrically conductive objects can be used to locate metallic objects as well as to assess the properties of materials non-destructively without physical contact. This technique is useful for material identification, such as measuring conductivity and for discriminating whether a sample is magnetic or non-magnetic. In this study, we carried out experiments and numerical s…
▽ More
Eddy currents induced in electrically conductive objects can be used to locate metallic objects as well as to assess the properties of materials non-destructively without physical contact. This technique is useful for material identification, such as measuring conductivity and for discriminating whether a sample is magnetic or non-magnetic. In this study, we carried out experiments and numerical simulations for the evaluation of conductive objects. We investigated the frequency dependence of the secondary magnetic field generated by induced eddy currents when a conductive object is placed in a primary oscillating magnetic field. According to the electromagnetic theory, conductive objects have different responses at different frequencies. Using a table-top setup consisting of a fluxgate magnetometer and a primary coil generating a magnetic field with frequency up to 1 kHz, we are able to detect aluminium and steel cylinders using the principle of electromagnetic induction. The experimental results are compared with numerical simulations and we find overall a good agreement. This technique enables identification and characterisation of objects using their electrical conductivity and magnetic permeability.
△ Less
Submitted 24 June, 2022;
originally announced June 2022.
-
Unshielded portable optically pumped magnetometer for the remote detection of conductive objects using eddy current measurements
Authors:
L. M. Rushton,
T. Pyragius,
A. Meraki,
L. Elson,
K. Jensen
Abstract:
Electrically conductive objects can be detected using the principle of electromagnetic induction where a primary oscillating magnetic field induces eddy currents in the object, which in turn produce a secondary magnetic field that can be measured with a magnetometer. We have developed a portable radio-frequency optically pumped magnetometer (RF OPM) working in unshielded conditions with sub-pT/sqr…
▽ More
Electrically conductive objects can be detected using the principle of electromagnetic induction where a primary oscillating magnetic field induces eddy currents in the object, which in turn produce a secondary magnetic field that can be measured with a magnetometer. We have developed a portable radio-frequency optically pumped magnetometer (RF OPM) working in unshielded conditions with sub-pT/sqrt(Hz) magnetic field sensitivity when used for the detection of small oscillating magnetic fields, setting a new benchmark for the sensitivity of a portable RF OPM in unshielded conditions. Using this OPM, we have detected the induced magnetic field from aluminium disks with diameters as small as 1.5 cm and with the disks being ~25 cm from both the excitation coil and the magnetometer. When used for eddy current detection, our magnetometer achieves a sensitivity of a 2-6 pT/sqrt(Hz). We have also detected a moving aluminium disk using our RF OPM and analysed the magnetometer signals which depend on the position of the disk, illustrating the potential of high sensitivity RF OPMs for remote sensing applications.
△ Less
Submitted 1 December, 2022; v1 submitted 9 June, 2022;
originally announced June 2022.