-
Microwave Frequency Fiber Interferometry in Submarine Deployed Telecommunication Cables
Authors:
A. Bogris,
C. Simos,
I. Simos,
Y. Wang,
A. Fichtner,
S. Deligiannidis,
N. S. Melis,
C. Mesaritakis
Abstract:
We operated a microwave frequency fiber interferometer in a telecommunication cable in the Ionian Sea, Greece, for two months. The capability of detecting undersea micro earthquakes (magnitude~1.5), tides and ocean waves is reported
We operated a microwave frequency fiber interferometer in a telecommunication cable in the Ionian Sea, Greece, for two months. The capability of detecting undersea micro earthquakes (magnitude~1.5), tides and ocean waves is reported
△ Less
Submitted 7 April, 2025;
originally announced April 2025.
-
Linking distributed and integrated fiber-optic sensing
Authors:
Daniel C. Bowden,
Andreas Fichtner,
Thomas Nikas,
Adonis Bogris,
Christos Simos,
Krystyna Smolinski,
Maria Koroni,
Konstantinos Lentas,
Iraklis Simos,
Nikolaos S. Melis
Abstract:
Distributed Acoustic Sensing (DAS) has become a popular method of observing seismic wavefields: backscattered pulses of light reveal strains or strain-rates at any location along a fiber-optic cable. In contrast, a few newer systems transmit light through a cable and collect integrated phase delays over the entire cable, such as the Microwave Frequency Fiber Interferometer (MFFI). These integrated…
▽ More
Distributed Acoustic Sensing (DAS) has become a popular method of observing seismic wavefields: backscattered pulses of light reveal strains or strain-rates at any location along a fiber-optic cable. In contrast, a few newer systems transmit light through a cable and collect integrated phase delays over the entire cable, such as the Microwave Frequency Fiber Interferometer (MFFI). These integrated systems can be deployed over significantly longer distances, may be used in conjunction with live telecommunications, and can be significantly cheaper. However, they provide only a single time series representing strain over the entire length of fiber. This work discusses theoretically how a distributed and integrated system can be quantitatively compared, and we note that the sensitivity depends strongly on points of curvature. Importantly, this work presents the first results of a quantitative, head-to-head comparison of a DAS and the integrated MFFI system using pre-existing telecommunications fibers in Athens, Greece.
△ Less
Submitted 23 May, 2022;
originally announced May 2022.
-
Introduction to phase transmission fibre-optic sensing of seismic waves
Authors:
Andreas Fichtner,
Adonis Bogris,
Thomas Nikas,
Daniel Bowden,
Konstantinos Lentas,
Nikolaos S. Melis,
Christos Simos,
Iraklis Simos,
Krystyna Smolinski
Abstract:
This manuscript is concerned with phase changes of signals transmitted through deforming optical fibres. As a first result, it establishes an exact relation between observable phase changes and the deformation tensor along the fibre. This relation is non-linear, and it includes effects related to both local changes in fibre length and deformation-induced changes of the local speed of light or refr…
▽ More
This manuscript is concerned with phase changes of signals transmitted through deforming optical fibres. As a first result, it establishes an exact relation between observable phase changes and the deformation tensor along the fibre. This relation is non-linear, and it includes effects related to both local changes in fibre length and deformation-induced changes of the local speed of light or refractive index. In seismic applications, where the norm of the earthquake-induced deformation tensor is orders of magnitude smaller than 1, a useful first-order relation can be derived. It simply connects phase changes to an integral over in-line strain along the fibre times the local refractive index. Under the assumption that spatial variations of the refractive index are fast compared to the seismic wavelength, this permits a direct synthesis of phase change measurements from distributed strain measurements, for instance, from Distributed Acoustic Sensing (DAS). A more detailed analysis of the first-order relation reveals that a perfectly straight fibre would produce zero phase change measurements, unless deformation was sufficiently widespread to affect the starting and end points of the fibre. If this condition is not met, non-zero measurements can only result from curvature of the fibre or from a heterogeneous distribution of the refractive index. Segments of the fibre that are strongly curved generally make larger contributions to the observed phase change.
△ Less
Submitted 28 February, 2022;
originally announced February 2022.
-
Microwave frequency dissemination systems as sensitive and low-cost interferometers for earthquake detection on commercially deployed fiber cables
Authors:
Adonis Bogris,
Christos Simos,
Iraklis Simos,
Thomas Nikas,
Nikolaos S. Melis,
Konstantinos Lentas,
Charis Mesaritakis,
Ioannis Chochliouros,
Christina Lessi
Abstract:
We experimentally demonstrate a microwave frequency dissemination system operating as a sensitive interferometric sensor of seismic waves on commercially deployed fiber networks in Attika, Greece. Efficient detection of seismic waves from distant epicenters (>400km)
We experimentally demonstrate a microwave frequency dissemination system operating as a sensitive interferometric sensor of seismic waves on commercially deployed fiber networks in Attika, Greece. Efficient detection of seismic waves from distant epicenters (>400km)
△ Less
Submitted 25 October, 2021;
originally announced November 2021.
-
Post-spontaneous-symmetry-breaking power-laws after a very strong earthquake: Indication for the preparation of a new strong earthquake or not?
Authors:
Stelios M. Potirakis,
Yiannis Contoyiannis,
Konstantinos Eftaxias,
Nikolaos S. Melis,
Constantinos Nomicos
Abstract:
It has recently been found that the evolution of the preparation of a strong earthquake (EQ), as it is monitored through fracture-induced electromagnetic emissions (EME) in the MHz band, presents striking similarity with the evolution of a thermal system as temperature drops, since distinct steps of the evolution of the phenomenon of spontaneous symmetry breaking (SSB) can be identified. Here, the…
▽ More
It has recently been found that the evolution of the preparation of a strong earthquake (EQ), as it is monitored through fracture-induced electromagnetic emissions (EME) in the MHz band, presents striking similarity with the evolution of a thermal system as temperature drops, since distinct steps of the evolution of the phenomenon of spontaneous symmetry breaking (SSB) can be identified. Here, the study of fracture-induced EME in the MHz band in analogy to thermal systems is extended to the phase of local fracture structures that follow after the SSB (and the occurrence of the main EQ). By comparing fracture-induced MHz EME associated with the strongest EQs (Mw=6.9) that occurred in Greece during the last twenty years with the 3D Ising model, a way to distinguish whether a possible identification of post-SSB power-laws immediately after a very strong EQ is a sign for the preparation of a new strong EQ or not is provided. In the suggested approach, the time series analysis method known as the method of critical fluctuations is used, enhanced by the autocorrelation function, while the role of the latter proves to be decisive.
△ Less
Submitted 11 April, 2021;
originally announced April 2021.
-
Pre-earthquake electromagnetic emissions with critical and tricritical behavior before the recent Durrës (Albania) (Mw=6.4, 26-11-2019) and Chania (Greece) (Mw=6.1, 27-11-2019) earthquakes
Authors:
Stelios M. Potirakis,
Yiannis Contoyiannis,
Grigorios E. Koulouras,
Nikolaos S. Melis,
Konstantinos Eftaxias,
Constantinos Nomicos
Abstract:
In this brief report we present evidence for the dynamics of the earthquake (EQ) preparation processes that led to two strong events (Mw>6) that took place in Durrës (Albania) and Chania (West-Crete, Greece) on 26 and 27-11-2019, respectively. Specifically, MHz fracto-electromagnetic emissions (EME) recorded by our telemetric stations presented critical fluctuations prior to each one of these EQs.…
▽ More
In this brief report we present evidence for the dynamics of the earthquake (EQ) preparation processes that led to two strong events (Mw>6) that took place in Durrës (Albania) and Chania (West-Crete, Greece) on 26 and 27-11-2019, respectively. Specifically, MHz fracto-electromagnetic emissions (EME) recorded by our telemetric stations presented critical fluctuations prior to each one of these EQs. Subsequently, the EME possibly related to each one of these EQs evolved differently towards the occurrence of the EQ event: the ones possibly related to Chania EQ departed from critical state according to the symmetry breaking phenomenon, while the ones possibly related to Durrës EQ departed from critical state according to the tricritical crossover phenomenon. The analysis was performed by means of the method of critical fluctuations (MCF).
△ Less
Submitted 11 December, 2019;
originally announced December 2019.
-
Preliminary results concerning the fracture-induced electromagnetic emissions recorded prior to the Mw 6.7 Earthquake on October 25, 2018 south of Zakynthos
Authors:
S. M. Potirakis,
Y. Contoyiannis,
N. S. Melis,
G. Koulouras,
J. Kopanas,
G. Antonopoulos,
K. Eftaxias,
C. Nomicos
Abstract:
In this letter we present preliminary results concerning precursors to the recent significant (Mw 6.7) earthquake (EQ) that took place in the region south of the Greek Island of Zakynthos (October 25, 2018). We show, in terms of fracture-induced electromagnetic emissions (EME), that the Earth system around the focal area was at critical state up to a few hours before the occurrence of the EQ. Impo…
▽ More
In this letter we present preliminary results concerning precursors to the recent significant (Mw 6.7) earthquake (EQ) that took place in the region south of the Greek Island of Zakynthos (October 25, 2018). We show, in terms of fracture-induced electromagnetic emissions (EME), that the Earth system around the focal area was at critical state up to a few hours before the occurrence of the EQ. Importantly, departure from the critical state, in terms of the symmetry breaking phenomenon, was also identified in the EME recorded after the appearance of the last signatures of criticality. The analysis was performed by means of the method of critical fluctuations (MCF).
△ Less
Submitted 24 November, 2018;
originally announced November 2018.
-
Robust seismic velocity change estimation using ambient noise recordings
Authors:
E. Daskalakis,
C. P. Evangelidis,
J. Garnier,
N. S. Melis,
G. Papanicolaou,
C. Tsogka
Abstract:
We consider the problem of seismic velocity change estimation using ambient noise recordings. Motivated by [23] we study how the velocity change estimation is affected by seasonal fluctuations in the noise sources. More precisely, we consider a numerical model and introduce spatio-temporal seasonal fluctuations in the noise sources. We show that indeed, as pointed out in [23], the stretching metho…
▽ More
We consider the problem of seismic velocity change estimation using ambient noise recordings. Motivated by [23] we study how the velocity change estimation is affected by seasonal fluctuations in the noise sources. More precisely, we consider a numerical model and introduce spatio-temporal seasonal fluctuations in the noise sources. We show that indeed, as pointed out in [23], the stretching method is affected by these fluctuations and produces misleading apparent velocity variations which reduce dramatically the signal to noise ratio of the method. We also show that these apparent velocity variations can be eliminated by an adequate normalization of the cross-correlation functions. Theoretically we expect our approach to work as long as the seasonal fluctuations in the noise sources are uniform, an assumption which holds for closely located seismic stations. We illustrate with numerical simulations and real measurements that the proposed normalization significantly improves the accuracy of the velocity change estimation.
△ Less
Submitted 18 February, 2016;
originally announced February 2016.