-
Accurate determination of the Boltzmann constant by Doppler spectroscopy: Towards a new definition of the kelvin
Authors:
Benoît Darquié,
Sinda Mejri,
Papa Lat Tabara Sow,
Cyril Lemarchand,
Meriam Triki,
Sean Tokunaga,
Christian J. Bordé,
Christian Chardonnet,
Christophe Daussy
Abstract:
Accurate molecular spectroscopy in the mid-infrared region allows precision measurements of fundamental constants. For instance, measuring the linewidth of an isolated Doppler-broadened absorption line of ammonia around 10 $μ$m enables a determination of the Boltzmann constant k B. We report on our latest measurements. By fitting this lineshape to several models which include Dicke narrowing or sp…
▽ More
Accurate molecular spectroscopy in the mid-infrared region allows precision measurements of fundamental constants. For instance, measuring the linewidth of an isolated Doppler-broadened absorption line of ammonia around 10 $μ$m enables a determination of the Boltzmann constant k B. We report on our latest measurements. By fitting this lineshape to several models which include Dicke narrowing or speed-dependent collisional effects, we find that a determination of k B with an uncertainty of a few ppm is reachable. This is comparable to the best current uncertainty obtained using acoustic methods and would make a significant contribution to any new value of k B determined by the CODATA. Furthermore, having multiple independent measurements at these accuracies opens the possibility of defining the kelvin by fixing k B, an exciting prospect considering the upcoming redefinition of the International System of Units.
△ Less
Submitted 22 June, 2015;
originally announced June 2015.
-
Measuring the Boltzmann constant by mid-infrared laser spectroscopy of ammonia
Authors:
S. Mejri,
Papa Sow,
O. Kozlova,
C. Ayari,
Sean Tokunaga,
C. Chardonnet,
S. Briaudeau,
B. Darquié,
F. Rohart,
C. Daussy
Abstract:
We report on our ongoing effort to measure the Boltzmann constant, $k_B,$ using the Doppler broadening technique on ammonia. This paper presents some of the improvements made to the mid-infrared spectrometer including the use of a phase-stabilized quantum cascade laser, a lineshape analysis based on a refined physical model and an improved fitting program 2 increasing the confidence in our estimat…
▽ More
We report on our ongoing effort to measure the Boltzmann constant, $k_B,$ using the Doppler broadening technique on ammonia. This paper presents some of the improvements made to the mid-infrared spectrometer including the use of a phase-stabilized quantum cascade laser, a lineshape analysis based on a refined physical model and an improved fitting program 2 increasing the confidence in our estimates of the relevant molecular parameters, and a first evaluation of the saturation parameter and its impact on the measurement of k B. A summary of the systematic effects contributing to the measurement is given and the optimal experimental conditions for mitigating those effects in order to reach a competitive measurement of $k_B$ at a part per million accuracy level are outlined.
△ Less
Submitted 5 June, 2015;
originally announced June 2015.
-
Absorption line shape recovery beyond the detection bandwidth limit: application to the precision spectroscopic measurement of the Boltzmann constant
Authors:
François Rohart,
Sinda Mejri,
Papa Lat Tabara Sow,
Sean K. Tokunaga,
Christian Chardonnet,
Benoît Darquié,
H. Dinesan,
E. Fasci,
A. Castrillo,
L. Gianfrani,
Christophe Daussy
Abstract:
A theoretical model of the influence of detection bandwidth properties on observed line shapes in laser absorption spectroscopy is described. The model predicts artificial frequency shifts, extra broadenings and line asymmetries which must be taken into account in order to obtain accurate central frequencies and other spectroscopic parameters. This reveals sources of systematic effects most probab…
▽ More
A theoretical model of the influence of detection bandwidth properties on observed line shapes in laser absorption spectroscopy is described. The model predicts artificial frequency shifts, extra broadenings and line asymmetries which must be taken into account in order to obtain accurate central frequencies and other spectroscopic parameters. This reveals sources of systematic effects most probably underestimated so far potentially affecting spectroscopic measurements. This may impact many fields of research, from atmospheric and interstellar physics to precision spectroscopic measurements devoted to metrological applications, tests of quantum electrodynamics or other fundamental laws of nature. Our theoretical model is validated by linear absorption experiments performed on H2O and NH3 molecular lines recorded by precision laser spectroscopy in two distinct spectral regions, near- and mid-infrared. Possible means of recovering original line shape parameters or experimental conditions under which the detection bandwidth has a negligible impact, given a targeted accuracy, are proposed. Particular emphasis is put on the detection bandwidth adjustments required to use such high-quality molecular spectra for a spectroscopic determination of the Boltzmann constant at the 1 ppm level of accuracy.
△ Less
Submitted 9 July, 2014; v1 submitted 11 June, 2014;
originally announced June 2014.
-
A widely tunable 10-$μ$m quantum cascade laser phase-locked to a state-of-the-art mid-infrared reference for precision molecular spectroscopy
Authors:
Papa Lat Tabara Sow,
Sinda Mejri,
Sean K. Tokunaga,
Olivier Lopez,
Andrey Goncharov,
Bérengère Argence,
Christian Chardonnet,
Anne Amy-Klein,
Christophe Daussy,
Benoît Darquié
Abstract:
We report the coherent phase-locking of a quantum cascade laser (QCL) at 10-$μ$m to the secondary frequency standard of this spectral region, a CO2 laser stabilized on a saturated absorption line of OsO4. The stability and accuracy of the standard are transferred to the QCL resulting in a line width of the order of 10 Hz, and leading to our knowledge to the narrowest QCL to date. The locked QCL is…
▽ More
We report the coherent phase-locking of a quantum cascade laser (QCL) at 10-$μ$m to the secondary frequency standard of this spectral region, a CO2 laser stabilized on a saturated absorption line of OsO4. The stability and accuracy of the standard are transferred to the QCL resulting in a line width of the order of 10 Hz, and leading to our knowledge to the narrowest QCL to date. The locked QCL is then used to perform absorption spectroscopy spanning 6 GHz of NH3 and methyltrioxorhenium, two species of interest for applications in precision measurements.
△ Less
Submitted 4 April, 2014;
originally announced April 2014.
-
A revised uncertainty budget for measuring the Boltzmann constant using the Doppler Broadening Technique on ammonia
Authors:
Cyril Lemarchand,
Sinda Mejri,
Papa Lat Tabara Sow,
Meriam Triki,
Sean K. Tokunaga,
Stephan Briaudeau,
Christian Chardonnet,
Benoît Darquié,
Christophe Daussy
Abstract:
We report on our on-going effort to measure the Boltzmann constant, kB, using the Doppler Broadening Technique. The main systematic effects affecting the measurement are discussed. A revised error budget is presented in which the global uncertainty on systematic effects is reduced to 2.3 ppm. This corresponds to a reduction of more than one order of magnitude compared to our previous Boltzmann con…
▽ More
We report on our on-going effort to measure the Boltzmann constant, kB, using the Doppler Broadening Technique. The main systematic effects affecting the measurement are discussed. A revised error budget is presented in which the global uncertainty on systematic effects is reduced to 2.3 ppm. This corresponds to a reduction of more than one order of magnitude compared to our previous Boltzmann constant measurement. Means to reach a determination of kB at the part per million accuracy level are outlined.
△ Less
Submitted 18 September, 2013;
originally announced September 2013.
-
A neutral atom frequency reference in the deep UV with 10^(-15) range uncertainty
Authors:
J. J. McFerran,
L. Yi,
S. Mejri,
S. Di Manno,
W. Zhang,
J. Guéna,
Y. Le Coq,
S. Bize
Abstract:
We present an assessment of the (6s^{2})1S0 -> (6s7s)3P0 clock transition frequency in 199Hg with an uncertainty reduction of nearly three orders of magnitude and demonstrate an atomic quality factor, Q, of ~10^(14). The 199Hg atoms are confined in a vertical lattice trap with light at the newly determined magic wavelength of 362.5697 +/-0.0011 nm and at a lattice depth of 20Er. The atoms are load…
▽ More
We present an assessment of the (6s^{2})1S0 -> (6s7s)3P0 clock transition frequency in 199Hg with an uncertainty reduction of nearly three orders of magnitude and demonstrate an atomic quality factor, Q, of ~10^(14). The 199Hg atoms are confined in a vertical lattice trap with light at the newly determined magic wavelength of 362.5697 +/-0.0011 nm and at a lattice depth of 20Er. The atoms are loaded from a single stage magneto-optical trap with cooling light at 253.7 nm. The high Q factor is obtained with an 80 ms Rabi pulse at 265.6 nm. The frequency of the clock transition is found to be 1 128 575 290 808 162.0 +/-6.4 (sys.) +/-0.3 (stat.) Hz (fractional uncertainty = 5.7x10^(-15)). Neither an atom number nor second order Zeeman dependence have yet to be detected. Only three laser wavelengths are used for the cooling, lattice trapping, probing and detection.
△ Less
Submitted 17 January, 2012;
originally announced January 2012.