-
waveOrder: generalist framework for label-agnostic computational microscopy
Authors:
Talon Chandler,
Eduardo Hirata-Miyasaki,
Ivan E. Ivanov,
Ziwen Liu,
Deepika Sundarraman,
Allyson Quinn Ryan,
Adrian Jacobo,
Keir Balla,
Shalin B. Mehta
Abstract:
Correlative computational microscopy is accelerating the mapping of dynamic biological systems by integrating morphological and molecular measurements across spatial scales, from organelles to entire organisms. Visualization, measurement, and prediction of interactions among the components of biological systems can be accelerated by generalist computational imaging frameworks that relax the trade-…
▽ More
Correlative computational microscopy is accelerating the mapping of dynamic biological systems by integrating morphological and molecular measurements across spatial scales, from organelles to entire organisms. Visualization, measurement, and prediction of interactions among the components of biological systems can be accelerated by generalist computational imaging frameworks that relax the trade-offs imposed by multiplex dynamic imaging. This work reports a generalist framework for wave optical imaging of the architectural order (waveOrder) among biomolecules for encoding and decoding multiple specimen properties from a minimal set of acquired channels, with or without fluorescent labels. waveOrder expresses material properties in terms of elegant physically motivated basis vectors directly interpretable as phase, absorption, birefringence, diattenuation, and fluorophore density; and it expresses image data in terms of directly measurable Stokes parameters. We report a corresponding multi-channel reconstruction algorithm to recover specimen properties in multiple contrast modes. With this framework, we implement multiple 3D computational microscopy methods, including quantitative phase imaging, quantitative label-free imaging with phase and polarization, and fluorescence deconvolution imaging, across scales ranging from organelles to whole zebrafish. These advances are available via an extensible open-source computational imaging library, waveOrder, and a napari plugin, recOrder.
△ Less
Submitted 20 December, 2024; v1 submitted 12 December, 2024;
originally announced December 2024.
-
Dead-zone-free single-beam atomic magnetometer based on free-induction-decay of Rb atoms
Authors:
Shrey Mehta,
G. K. Samanta,
Raghwinder Singh Grewal
Abstract:
Free-induction-decay (FID) magnetometers have evolved as simple magnetic sensors for sensitive detection of unknown magnetic fields. However, these magnetometers suffer from a fundamental problem known as a "dead zone," making them insensitive to certain magnetic field directions. Here, we demonstrate a simple experimental scheme for the dead-zone-free operation of a FID atomic magnetometer. Using…
▽ More
Free-induction-decay (FID) magnetometers have evolved as simple magnetic sensors for sensitive detection of unknown magnetic fields. However, these magnetometers suffer from a fundamental problem known as a "dead zone," making them insensitive to certain magnetic field directions. Here, we demonstrate a simple experimental scheme for the dead-zone-free operation of a FID atomic magnetometer. Using a single laser beam containing equal strength of linear- and circular-polarization components and amplitude-modulation at a low-duty cycle, we have synchronously pumped the rubidium-87 atoms with both first- and second-order frequency harmonics. Such a pumping scheme has enabled us to observe the free Larmor precession of atomic spins at a frequency of $Ω_L$ (orientation) and/or 2$Ω_L$ (alignment) in a single FID signal, depending on the direction of the external magnetic field. We observed that the amplitude of the FID signal does not go to zero for any magnetic field direction, proving the absence of dead zones in the magnetometer. The magnetometer has a sensitivity in the range of 3.2 - 8.4 pT/$\sqrt{Hz}$ in all directions. Our experimental scheme can be crucial in developing miniaturized atomic magnetometers for various practical applications, including geomagnetic applications.
△ Less
Submitted 12 January, 2025; v1 submitted 21 October, 2024;
originally announced October 2024.
-
Unveiling nutrient flow mediated stress in the plant roots using on-chip phytofluidic device
Authors:
Kaushal Agarwal,
Sumit Kumar Mehta,
Pranab Kumar Mondal
Abstract:
The initial emergence of the primary root from a germinating seed is a pivotal phase that influences a plant's survival. Abiotic factors such as pH, nutrient availability, and soil composition significantly affect root morphology and architecture. Of particular interest is the impact of nutrient flow on thigmomorphogenesis, a response to mechanical stimulation in early root growth, which remains l…
▽ More
The initial emergence of the primary root from a germinating seed is a pivotal phase that influences a plant's survival. Abiotic factors such as pH, nutrient availability, and soil composition significantly affect root morphology and architecture. Of particular interest is the impact of nutrient flow on thigmomorphogenesis, a response to mechanical stimulation in early root growth, which remains largely unexplored. This study explores the intricate factors influencing early root system development, with a focus on the cooperative correlation between nutrient uptake and its flow dynamics. Using physiologically relevant, portable, and cost-effective microfluidic system for the controlled fluid environments offering hydraulic conductivity comparable to that of the soil, this study analyzes the interplay between nutrient flow and root growth post-germination. Emphasizing the relationship between root growth and nitrogen uptake, the findings reveal that nutrient flow significantly influences early root morphology, leading to increased length and improved nutrient uptake, varying with the flow rate. The experimental findings are supported by stress-related fluid flow-root interaction simulations and quantitative determination of nitrogen uptake using the Total Kjeldahl Nitrogen (TKN) method. The microfluidic approach offers novel insights into plant root dynamics under controlled flow conditions, filling a critical research gap. By providing a high-resolution platform, this study contributes to the understanding of how fluid-flow assisted nutrient uptake and pressure affect root-cell behavior, which, in turn, induces mechanical stress leading to thigmomorphogenesis. The findings hold implications for comprehending root responses to changing environmental conditions, paving the way for innovative agricultural and environmental management strategies.
△ Less
Submitted 6 March, 2024;
originally announced March 2024.
-
Capability enhancement of the X-ray micro-tomography system via ML-assisted approaches
Authors:
Dhruvi Shah,
Shruti Mehta,
Ashish Agrawal,
Shishir Purohit,
Bhaskar Chaudhury
Abstract:
Ring artifacts in X-ray micro-CT images are one of the primary causes of concern in their accurate visual interpretation and quantitative analysis. The geometry of X-ray micro-CT scanners is similar to the medical CT machines, except the sample is rotated with a stationary source and detector. The ring artifacts are caused by a defect or non-linear responses in detector pixels during the MicroCT d…
▽ More
Ring artifacts in X-ray micro-CT images are one of the primary causes of concern in their accurate visual interpretation and quantitative analysis. The geometry of X-ray micro-CT scanners is similar to the medical CT machines, except the sample is rotated with a stationary source and detector. The ring artifacts are caused by a defect or non-linear responses in detector pixels during the MicroCT data acquisition. Artifacts in MicroCT images can often be so severe that the images are no longer useful for further analysis. Therefore, it is essential to comprehend the causes of artifacts and potential solutions to maximize image quality. This article presents a convolution neural network (CNN)-based Deep Learning (DL) model inspired by UNet with a series of encoder and decoder units with skip connections for removal of ring artifacts. The proposed architecture has been evaluated using the Structural Similarity Index Measure (SSIM) and Mean Squared Error (MSE). Additionally, the results are compared with conventional filter-based non-ML techniques and are found to be better than the latter.
△ Less
Submitted 8 February, 2024;
originally announced February 2024.
-
From 3D to 5D tracking: SMX ASIC-based Double-Sided Micro-Strip detectors for comprehensive space, time, and energy measurements
Authors:
M. Teklishyn,
A. Rodríguez Rodríguez,
K. Agarwal,
M. Bajdel,
L. M. Collazo Sánchez,
U. Frankenfeld,
J. M. Heuser,
J. Lehnert,
S. Mehta,
D. Rodríguez Garcés,
D. A. Ramírez Zaldívar,
C. J. Schmidt,
H. R. Schmidt,
A. Toia
Abstract:
We present the recent development of a lightweight detector capable of accurate spatial, timing, and amplitude resolution of charged particles. The technology is based on double-sided double-metal p+\,--\,n\,--\,n+ micro-strip silicon sensors, ultra-light long aluminum-polyimide micro-cables for the analogue signal transfer, and a custom-developed SMX read-out ASIC capable of measurement of the ti…
▽ More
We present the recent development of a lightweight detector capable of accurate spatial, timing, and amplitude resolution of charged particles. The technology is based on double-sided double-metal p+\,--\,n\,--\,n+ micro-strip silicon sensors, ultra-light long aluminum-polyimide micro-cables for the analogue signal transfer, and a custom-developed SMX read-out ASIC capable of measurement of the time ($Δt \lesssim 5 \,\mathrm{ns}$) and amplitude. Dense detector integration enables a material budget $>0.3\,\% X_0$. A sophisticated powering and grounding scheme keeps the noise under control.
In addition to its primary application in Silicon Tracking System of the future CBM experiment in Darmstadt, our detector will be utilized in other research applications.
△ Less
Submitted 3 November, 2023;
originally announced November 2023.
-
Multimodal Optical Techniques in Pre-Clinical Evaluation of Oral Cancer: Fluorescence Imaging and Spectroscopic Devices
Authors:
Pramila Thapa,
Veena Singh,
Virendra Kumar,
Sunil Bhatt,
Kiran Maurya,
Vivek Nayyar,
Kiran Jot,
Deepika Mishra,
Anurag Shrivastava,
Dalip Singh Mehta
Abstract:
Objective: Survival rate of oral squamous cell carcinoma (OSCC) patients is very poor and can be improved using highly sensitive, specific and accurate techniques. Autofluorescence and fluorescence techniques are very sensitive and useful in cancer screening. Furthermore, fluorescence spectroscopy is directly linked with molecular levels of human tissue and can be used as quantitative tool for can…
▽ More
Objective: Survival rate of oral squamous cell carcinoma (OSCC) patients is very poor and can be improved using highly sensitive, specific and accurate techniques. Autofluorescence and fluorescence techniques are very sensitive and useful in cancer screening. Furthermore, fluorescence spectroscopy is directly linked with molecular levels of human tissue and can be used as quantitative tool for cancer detection. Materials and Methods: Here, we report development of multi-modal autofluorescence and fluorescence imaging and spectroscopic (MAF-IS) smartphone-based systems for fast and real time oral cancer screening. Fluorescence-autofluorescence images and spectroscopic datasets shows significant change in oral cancer and normal tissue in terms of fluorescence-intensity, spectral-shape, and red-shift respectively. Results: In this study, total 68 samples (33 cancerous and 35 normal) of 18 OSCC patients and 13 patients of precancerous tissues (dysplasia and fibrosis) are screened. Main remarkable finding of the study is presence of three peaks viz ~636 nm, ~680 nm and ~705 nm with decrease in intensity around 450 nm ~ 520 nm in OSCC in case of autofluorescence. Another finding is red shift in fluorescence spectroscopy of OSCC, dysplasia and fibrosis from normal which is 6.59+-4.54 nm, 3+-4.78 nm and 1.5+-0.5 nm respectively and can be used as cancer marker in real-time screening. Finally, support vector machine (SVM) based classifier is applied for classification of OSCC tissue from normal tissue. The average sensitivity, specificity and accuracy are found as 88.89% ,100 %, and 95%, respectively. Conclusion: Autofluorescence and fluorescence-based imaging and spectroscopy is used for pre-clinical screening of different oral lesions.
△ Less
Submitted 3 November, 2022;
originally announced November 2022.
-
Single-shot multispectral quantitative phase imaging using deep neural network
Authors:
Sunil Bhatt,
Ankit Butola,
Anand Kumar,
Pramila Thapa,
Akshay Joshi,
Neetu Singh,
Krishna Agarwal,
Dalip Singh Mehta
Abstract:
Multi-spectral quantitative phase imaging (MS-QPI) is a cutting-edge label-free technique to determine the morphological changes, refractive index variations and spectroscopic information of the specimens. The bottleneck to implement this technique to extract quantitative information, is the need of more than two measurements for generating MS-QPI images. We propose a single-shot MS-QPI technique…
▽ More
Multi-spectral quantitative phase imaging (MS-QPI) is a cutting-edge label-free technique to determine the morphological changes, refractive index variations and spectroscopic information of the specimens. The bottleneck to implement this technique to extract quantitative information, is the need of more than two measurements for generating MS-QPI images. We propose a single-shot MS-QPI technique using highly spatially sensitive digital holographic microscope assisted with deep neural network (DNN). Our method first acquires the interferometric datasets corresponding to multiple wavelengths (λ=532, 633 and 808 nm used here). The acquired datasets are used to train generative adversarial network (GAN) to generate multi-spectral quantitative phase maps from a single input interferogram. The network is trained and validated on two different samples, the optical waveguide and a MG63 osteosarcoma cells. Further, validation of the framework is performed by comparing the predicted phase maps with experimentally acquired and processed multi-spectral phase maps. The current MS-QPI+DNN framework can further empower spectroscopic QPI to improve the chemical specificity without complex instrumentation and color-cross talk.
△ Less
Submitted 5 January, 2022;
originally announced January 2022.
-
Statistical topology of the streamlines of a two-dimensional flow
Authors:
M. Kamb,
J. Byrum,
G. Huber,
G. Le Treut,
S. Mehta,
B. Veytsman,
D. Yllanes
Abstract:
Recent experiments on mucociliary clearance, an important defense against airborne pathogens, have raised questions about the topology of two-dimensional (2D) flows. We introduce a framework for studying ensembles of 2D time-invariant flow fields and estimating the probability for a particle to leave a finite area (to clear out). We establish two upper bounds on this probability by leveraging diff…
▽ More
Recent experiments on mucociliary clearance, an important defense against airborne pathogens, have raised questions about the topology of two-dimensional (2D) flows. We introduce a framework for studying ensembles of 2D time-invariant flow fields and estimating the probability for a particle to leave a finite area (to clear out). We establish two upper bounds on this probability by leveraging different insights about the distribution of flow velocities on the closed and open streamlines. We also deduce an exact power-series expression for the trapped area based on the asymptotic dynamics of flow-field trajectories and complement our analytical results with numerical simulations.
△ Less
Submitted 11 February, 2023; v1 submitted 20 October, 2021;
originally announced October 2021.
-
High throughput spatially sensitive single-shot quantitative phase microscopy
Authors:
Azeem Ahmad,
Vishesh Dubey,
Nikhil Jayakumar,
Anowarul Habib,
Ankit Butola,
Mona Nystad,
Ganesh Acharya,
Purusotam Basnet,
Dalip Singh Mehta,
Balpreet Singh Ahluwalia
Abstract:
High space-bandwidth product with high spatial phase sensitivity is indispensable for a single-shot quantitative phase microscopy (QPM) system. It opens avenue for widespread applications of QPM in the field of biomedical imaging. Temporally low coherence length light sources are generally implemented to achieve high spatial phase sensitivity in QPM at the cost of either reduced temporal resolutio…
▽ More
High space-bandwidth product with high spatial phase sensitivity is indispensable for a single-shot quantitative phase microscopy (QPM) system. It opens avenue for widespread applications of QPM in the field of biomedical imaging. Temporally low coherence length light sources are generally implemented to achieve high spatial phase sensitivity in QPM at the cost of either reduced temporal resolution or smaller field of view (FOV). On the contrary, high temporal coherence light sources like lasers are capable of exploiting the full FOV of the QPM systems at the expense of less spatial phase sensitivity. In the present work, we employed pseudo-thermal light source (PTLS) in QPM which overcomes the limitations of conventional light sources. The capabilities of PTLS over conventional light sources are systematically studied and demonstrated on various test objects like USAF resolution chart and thin optical waveguide (height ~ 8 nm). The spatial phase sensitivity of QPM in case of PTLS is measured to be equivalent to that for white light source. The high-speed and large FOV capabilities of PTLS based QPM is demonstrated by high-speed imaging of live sperm cells that is limited by the camera speed and by imaging extra-ordinary large FOV phase imaging on histopathology placenta tissue samples.
△ Less
Submitted 11 December, 2020;
originally announced December 2020.
-
High-resolution single-shot phase-shifting interference microscopy using deep neural network for quantitative phase imaging of biological samples
Authors:
Sunil Bhatt,
Ankit Butola,
Sheetal Raosaheb Kanade,
Anand Kumar,
Dalip Singh Mehta
Abstract:
White light phase-shifting interference microscopy (WL-PSIM) is a prominent technique for high-resolution quantitative phase imaging (QPI) of industrial and biological specimens. However, multiple interferograms with accurate phase-shifts are essentially required in WL-PSIM for measuring the accurate phase of the object. Here, we present single-shot phase-shifting interferometric techniques for ac…
▽ More
White light phase-shifting interference microscopy (WL-PSIM) is a prominent technique for high-resolution quantitative phase imaging (QPI) of industrial and biological specimens. However, multiple interferograms with accurate phase-shifts are essentially required in WL-PSIM for measuring the accurate phase of the object. Here, we present single-shot phase-shifting interferometric techniques for accurate phase measurement using filtered white light phase-shifting interference microscopy (F-WL-PSIM) and deep neural network (DNN). The methods are incorporated by training the DNN to generate 1) four phase-shifted frames and 2) direct phase from a single interferogram. The training of network is performed on two different samples i.e., optical waveguide and MG63 osteosarcoma cells. Further, performance of F-WL-PSIM+DNN framework is validated by comparing the phase map extracted from network generated and experimentally recorded interferograms. The current approach can further strengthen QPI techniques for high-resolution phase recovery using a single frame for different biomedical applications.
△ Less
Submitted 3 May, 2021; v1 submitted 14 October, 2020;
originally announced October 2020.
-
Multi-modal on-chip nanoscopy and quantitative phase image reveals the morphology of liver sinusoidal enodthelial cells
Authors:
David A. Coucheron,
Ankit Butola,
Karolina Szafranska,
Azeem Ahmad,
Jean-Claude Tinguely,
Peter McCourt,
Paramasivam Senthilkumaran,
Dalip Singh Mehta,
Balpreet Singh Ahluwalia
Abstract:
Visualization of three-dimensional morphological changes in the subcellular structures of a biological specimen is one of the greatest challenges in life science. Despite conspicuous refinements in optical nanoscopy, determination of quantitative changes in subcellular structure, i.e., size and thickness, remains elusive. We present an integrated chip-based optical nanoscopy set-up that provides a…
▽ More
Visualization of three-dimensional morphological changes in the subcellular structures of a biological specimen is one of the greatest challenges in life science. Despite conspicuous refinements in optical nanoscopy, determination of quantitative changes in subcellular structure, i.e., size and thickness, remains elusive. We present an integrated chip-based optical nanoscopy set-up that provides a lateral optical resolution of 61 nm combined with a highly sensitive quantitative phase microscopy (QPM) system with a spatial phase sensitivity of $\pm$20 mrad. We use the system to obtain the 3D morphology of liver sinusoidal endothelial cells (LSECs) combined with super-resolved spatial information. LSECs have a unique morphology with nanopores that are present in the plasma membrane, called fenestration. The fenestrations are grouped in clusters called sieve plates, which are around 100 nm thick. Thus, imaging and quantification of fenestration and sieve plate thickness requires resolution and sensitivity of sub-100 nm along both lateral and axial directions. In the chip-based nanoscope, the optical waveguides are used both for hosting and illuminating the sample. A strong evanescent field is generated on top of the waveguide surface for single molecule fluorescence excitation. The fluorescence signal is captured by an upright microscope, which is converted into a Linnik-type interferometer to sequentially acquire both super-resolved images and quantitative phase information of the sample. The multi-modal microscope provided an estimate of the fenestration diameter of 124$\pm$41 nm and revealed the average estimated thickness of the sieve plates in the range of 91.2$\pm$43.5 nm for two different cells. The combination of these techniques offers visualization of both the lateral size (using nanoscopy) and the thickness map of sieve plates, i.e. discrete clusters fenestrations in QPM mode.
△ Less
Submitted 22 July, 2020;
originally announced July 2020.
-
High space-bandwidth in quantitative phase imaging using partially spatially coherent optical coherence microscopy and deep neural network
Authors:
Ankit Butola,
Sheetal Raosaheb Kanade,
Sunil Bhatt,
Vishesh Kumar Dubey,
Anand Kumar,
Azeem Ahmad,
Dilip K Prasad,
Paramasivam Senthilkumaran,
Balpreet Singh Ahluwalia,
Dalip Singh Mehta
Abstract:
Quantitative phase microscopy (QPM) is a label-free technique that enables to monitor morphological changes at subcellular level. The performance of the QPM system in terms of spatial sensitivity and resolution depends on the coherence properties of the light source and the numerical aperture (NA) of objective lenses. Here, we propose high space-bandwidth QPM using partially spatially coherent opt…
▽ More
Quantitative phase microscopy (QPM) is a label-free technique that enables to monitor morphological changes at subcellular level. The performance of the QPM system in terms of spatial sensitivity and resolution depends on the coherence properties of the light source and the numerical aperture (NA) of objective lenses. Here, we propose high space-bandwidth QPM using partially spatially coherent optical coherence microscopy (PSC-OCM) assisted with deep neural network. The PSC source synthesized to improve the spatial sensitivity of the reconstructed phase map from the interferometric images. Further, compatible generative adversarial network (GAN) is used and trained with paired low-resolution (LR) and high-resolution (HR) datasets acquired from PSC-OCM system. The training of the network is performed on two different types of samples i.e. mostly homogenous human red blood cells (RBC) and on highly heterogenous macrophages. The performance is evaluated by predicting the HR images from the datasets captured with low NA lens and compared with the actual HR phase images. An improvement of 9 times in space-bandwidth product is demonstrated for both RBC and macrophages datasets. We believe that the PSC-OCM+GAN approach would be applicable in single-shot label free tissue imaging, disease classification and other high-resolution tomography applications by utilizing the longitudinal spatial coherence properties of the light source.
△ Less
Submitted 5 July, 2020;
originally announced July 2020.
-
High spatially sensitive quantitative phase imaging assisted with deep neural network for classification of human spermatozoa under stressed condition
Authors:
Ankit Butola,
Daria Popova,
Dilip K Prasad,
Azeem Ahmad,
Anowarul Habib,
Jean Claude Tinguely,
Purusotam Basnet,
Ganesh Acharya,
Paramasivam Senthilkumaran,
Dalip Singh Mehta,
Balpreet Singh Ahluwalia
Abstract:
Sperm cell motility and morphology observed under the bright field microscopy are the only criteria for selecting particular sperm cell during Intracytoplasmic Sperm Injection (ICSI) procedure of Assisted Reproductive Technology (ART). Several factors such as, oxidative stress, cryopreservation, heat, smoking and alcohol consumption, are negatively associated with the quality of sperm cell and fer…
▽ More
Sperm cell motility and morphology observed under the bright field microscopy are the only criteria for selecting particular sperm cell during Intracytoplasmic Sperm Injection (ICSI) procedure of Assisted Reproductive Technology (ART). Several factors such as, oxidative stress, cryopreservation, heat, smoking and alcohol consumption, are negatively associated with the quality of sperm cell and fertilization potential due to the changing of sub-cellular structures and functions which are overlooked. A bright field imaging contrast is insufficient to distinguish tiniest morphological cell features that might influence the fertilizing ability of sperm cell. We developed a partially spatially coherent digital holographic microscope (PSC-DHM) for quantitative phase imaging (QPI) in order to distinguish normal sperm cells from sperm cells under different stress conditions such as cryopreservation, exposure to hydrogen peroxide and ethanol without any labeling. Phase maps of 10,163 sperm cells (2,400 control cells, 2,750 spermatozoa after cryopreservation, 2,515 and 2,498 cells under hydrogen peroxide and ethanol respectively) are reconstructed using the data acquired from PSC-DHM system. Total of seven feedforward deep neural networks (DNN) were employed for the classification of the phase maps for normal and stress affected sperm cells. When validated against the test dataset, the DNN provided an average sensitivity, specificity and accuracy of 84.88%, 95.03% and 85%, respectively. The current approach DNN and QPI techniques of quantitative information can be applied for further improving ICSI procedure and the diagnostic efficiency for the classification of semen quality in regards to their fertilization potential and other biomedical applications in general.
△ Less
Submitted 18 February, 2020;
originally announced February 2020.
-
Influence of laser spot size at diffuser plane on the longitudinal spatial coherence function of optical coherence microscopy system
Authors:
Kashif Usmani,
Azeem Ahmad,
Rakesh Joshi,
Vishesh Dubey,
Ankit Butola,
Dalip Singh Mehta
Abstract:
Coherence properties and wavelength of light sources are indispensable for optical coherence microscopy/tomography as they greatly influence the signal to noise ratio, axial resolution, and penetration depth of the system. In the present letter, we investigated the longitudinal spatial coherence properties of the pseudo-thermal light source (PTS) as a function of spot size at the diffuser plane, w…
▽ More
Coherence properties and wavelength of light sources are indispensable for optical coherence microscopy/tomography as they greatly influence the signal to noise ratio, axial resolution, and penetration depth of the system. In the present letter, we investigated the longitudinal spatial coherence properties of the pseudo-thermal light source (PTS) as a function of spot size at the diffuser plane, which is controlled by translating microscope objective lens towards or away from the diffuser plane. The axial resolution of PTS is found to be maximum ~ 13 microns for the beam spot size of 3.5 mm at the diffuser plane. The change in the axial resolution of the system as the spot size is increased at the diffuser plane is further confirmed by performing experiments on standard gauge blocks of height difference of 15 microns. Thus, by appropriately choosing the beam spot size at the diffuser plane, any monochromatic laser light source depending on the biological window can be utilized to obtain high axial-resolution with large penetration depth and speckle-free tomographic images of multilayered biological specimens irrespective of the source temporal coherence length. In addition, PTS could be an attractive alternative light source for achieving high axial-resolution without needing chromatic aberration corrected optics and dispersion-compensation mechanism, unlike conventional setups.
△ Less
Submitted 7 April, 2019;
originally announced April 2019.
-
Deep learning architecture LightOCT for diagnostic decision support using optical coherence tomography images of biological samples
Authors:
Ankit Butola,
Dilip K. Prasad,
Azeem Ahmad,
Vishesh Dubey,
Darakhshan Qaiser,
Anurag Srivastava,
Paramsivam Senthilkumaran,
Balpreet Singh Ahluwalia,
Dalip Singh Mehta
Abstract:
Optical coherence tomography (OCT) is being increasingly adopted as a label-free and non-invasive technique for biomedical applications such as cancer and ocular disease diagnosis. Diagnostic information for these tissues is manifest in textural and geometric features of the OCT images, which are used by human expertise to interpret and triage. However, it suffers delays due to the long process of…
▽ More
Optical coherence tomography (OCT) is being increasingly adopted as a label-free and non-invasive technique for biomedical applications such as cancer and ocular disease diagnosis. Diagnostic information for these tissues is manifest in textural and geometric features of the OCT images, which are used by human expertise to interpret and triage. However, it suffers delays due to the long process of the conventional diagnostic procedure and shortage of human expertise. Here, a custom deep learning architecture, LightOCT, is proposed for the classification of OCT images into diagnostically relevant classes. LightOCT is a convolutional neural network with only two convolutional layers and a fully connected layer, but it is shown to provide excellent training and test results for diverse OCT image datasets. We show that LightOCT provides 98.9% accuracy in classifying 44 normal and 44 malignant (invasive ductal carcinoma) breast tissue volumetric OCT images. Also, >96% accuracy in classifying public datasets of ocular OCT images as normal, age-related macular degeneration and diabetic macular edema. Additionally, we show ~96% test accuracy for classifying retinal images as belonging to choroidal neovascularization, diabetic macular edema, drusen, and normal samples on a large public dataset of more than 100,000 images. The performance of the architecture is compared with transfer learning based deep neural networks. Through this, we show that LightOCT can provide significant diagnostic support for a variety of OCT images with sufficient training and minimal hyper-parameter tuning. The trained LightOCT networks for the three-classification problem will be released online to support transfer learning on other datasets.
△ Less
Submitted 6 July, 2020; v1 submitted 6 December, 2018;
originally announced December 2018.
-
Highly stable common-path quantitative phase microscope for biomedical imaging
Authors:
Azeem Ahmad,
Vishesh Dubey,
Ankit Butola,
Balpreet Singh Ahluwalia,
Dalip Singh Mehta
Abstract:
High temporal stability is the primary requirement of any quantitative phase microscope (QPM) systems for the early stage detection of various human related diseases. The high temporal stability of the system provides accurate measurement of membrane fluctuations of the biological cells, which can be good indicator of various diseases. We developed a single element highly stable common-path QPM sy…
▽ More
High temporal stability is the primary requirement of any quantitative phase microscope (QPM) systems for the early stage detection of various human related diseases. The high temporal stability of the system provides accurate measurement of membrane fluctuations of the biological cells, which can be good indicator of various diseases. We developed a single element highly stable common-path QPM system to obtain temporally stable holograms of the biological specimens. With the proposed system, the temporal stability is obtained ~ 15 mrad without using any vibration isolation table. The capability of the proposed system is demonstrated on USAF resolution chart, polystyrene spheres (dia. 4.5 micron) and human red blood cells (RBCs). The membrane fluctuation of healthy human RBCs is further successfully measured and found to be equal to 63 nm. Contrary to its counterparts, present system offers energy efficient, cost effective and simple way of generating object and reference beam for the development of common-path QPM.
△ Less
Submitted 3 December, 2018;
originally announced December 2018.
-
High-Precision Contactless Optical 3D-Metrology of Silicon Sensors
Authors:
E. Lavrik,
I. Panasenko,
S. Mehta,
U. Frankenfeld,
H. R. Schmidt
Abstract:
We describe a setup and procedures for contactless optical 3D-metrology of silicon micro-strip sensors. Space points are obtained by video microscopy and a high precision XY-table. The XY-dimensions are obtained from the movement of the table and pattern recognition, while the Z-dimension results from a Fast Fourier Transformation analyses of microscopic images taken at various distances of the op…
▽ More
We describe a setup and procedures for contactless optical 3D-metrology of silicon micro-strip sensors. Space points are obtained by video microscopy and a high precision XY-table. The XY-dimensions are obtained from the movement of the table and pattern recognition, while the Z-dimension results from a Fast Fourier Transformation analyses of microscopic images taken at various distances of the optical system from the object under investigation. The setup is employed to measure the position of silicon sensors mounted onto a carbon fibre structure with a precision of a few microns.
△ Less
Submitted 3 December, 2018;
originally announced December 2018.
-
Sub-nanometer height sensitivity by phase shifting interference microscopy under ambient environmental fluctuations
Authors:
Azeem Ahmad,
Vishesh Dubey,
Ankit Butola,
Jean-Claude Tinguely,
Balpreet Singh Ahluwalia,
Dalip Singh Mehta
Abstract:
Phase shifting interferometric (PSI) techniques are among the most sensitive phase measurement methods. Owing to its high sensitivity, any minute phase change caused due to environmental instability results into, inaccurate phase measurement. Consequently, a well calibrated piezo electric transducer (PZT) and highly-stable environment is mandatory for measuring accurate phase map using PSI impleme…
▽ More
Phase shifting interferometric (PSI) techniques are among the most sensitive phase measurement methods. Owing to its high sensitivity, any minute phase change caused due to environmental instability results into, inaccurate phase measurement. Consequently, a well calibrated piezo electric transducer (PZT) and highly-stable environment is mandatory for measuring accurate phase map using PSI implementation. Here, we present a new method of recording temporal phase shifted interferograms and a numerical algorithm, which can retrieve phase maps of the samples with negligible errors under the ambient environmental fluctuations. The method is implemented by recording a video of continuous temporally phase shifted interferograms and phase shifts were calculated between all the data frames using newly developed algorithm with a high accuracy less than or equal to 5.5*10-4*pi rad. To demonstrate the robustness of the proposed method, a manual translation of the stage was employed to introduce continuous temporal phase shift between data frames. The developed algorithm is first verified by performing quantitative phase imaging of optical waveguide and red blood cells using uncalibrated PZT under the influence of vibrations/air turbulence and compared with the well calibrated PZT results. Furthermore, we demonstrated the potential of the proposed approach by acquiring the quantitative phase imaging of an optical waveguide with a rib height of only 2 nm. By using 12-bit CMOS camera the height of shallow rib waveguide is measured with a height sensitivity of 4 Angstrom without using PZT and in presence of environmental fluctuations.
△ Less
Submitted 2 December, 2018;
originally announced December 2018.
-
Characterization of color cross-talk of CCD detectors and its influence in multispectral quantitative phase imaging
Authors:
Azeem Ahmad,
Anand Kumar,
Vishesh Dubey,
Ankit Butola,
Balpreet Singh Ahluwalia,
Dalip Singh Mehta
Abstract:
Multi-spectral quantitative phase imaging (QPI) is an emerging imaging modality for wavelength dependent studies of several biological and industrial specimens. Simultaneous multi-spectral QPI is generally performed with color CCD cameras. However, color CCD cameras are suffered from the color crosstalk issue, which needed to be explored. Here, we present a new approach for accurately measuring th…
▽ More
Multi-spectral quantitative phase imaging (QPI) is an emerging imaging modality for wavelength dependent studies of several biological and industrial specimens. Simultaneous multi-spectral QPI is generally performed with color CCD cameras. However, color CCD cameras are suffered from the color crosstalk issue, which needed to be explored. Here, we present a new approach for accurately measuring the color crosstalk of 2D area detectors, without needing prior information about camera specifications. Color crosstalk of two different cameras commonly used in QPI, single chip CCD (1-CCD) and three chip CCD (3-CCD), is systematically studied and compared using compact interference microscopy. The influence of color crosstalk on the fringe width and the visibility of the monochromatic constituents corresponding to three color channels of white light interferogram are studied both through simulations and experiments. It is observed that presence of color crosstalk changes the fringe width and visibility over the imaging field of view. This leads to an unwanted non-uniform background error in the multi-spectral phase imaging of the specimens. It is demonstrated that the color crosstalk of the detector is the key limiting factor for phase measurement accuracy of simultaneous multi-spectral QPI systems.
△ Less
Submitted 5 October, 2018;
originally announced October 2018.
-
Study of longitudinal coherence properties of pseudo thermal light source as a function of source size and temporal coherence
Authors:
Azeem Ahmad,
Tanmoy Mahanty,
Vishesh Dubey,
Ankit Butola,
Balpreet Singh Ahluwalia,
Dalip Singh Mehta
Abstract:
In conventional OCT, broadband light sources are generally utilized to obtain high axial resolution due to their low temporal coherence (TC) length. Purely monochromatic (i.e., high TC length) light sources like laser cannot be implemented to acquire high resolution optically sectioned images of the specimen. Contrary to this, pseudo thermal light source having high TC and low spatial coherence (S…
▽ More
In conventional OCT, broadband light sources are generally utilized to obtain high axial resolution due to their low temporal coherence (TC) length. Purely monochromatic (i.e., high TC length) light sources like laser cannot be implemented to acquire high resolution optically sectioned images of the specimen. Contrary to this, pseudo thermal light source having high TC and low spatial coherence (SC) property can be employed to achieve high axial resolution comparable to broadband light source. In the present letter, a pseudo thermal light source is synthesized by passing a purely monochromatic laser beam through a rotating diffuser. The longitudinal coherence (LC) property of the pseudo thermal light source is studied as a function of source size and TC length. The LC length of the synthesized light source decreased as the source size increased. It is found that LC length of such light source becomes independent of the parent laser TC length for source size of greater than or equal to 3.3 mm and become almost constant at around 30 micron for both the lasers. Thus any monochromatic laser light source can be utilized to obtain high axial resolution in OCT system irrespective of its TC length. The maximum achievable axial resolution is found to be equal to 650 nm corresponding to 1.2 numerical aperture (NA) objective lens at 632 nm wavelength. The findings elucidate that pseudo thermal source being monochromatic in nature can improve the performance of existing OCT systems significantly.
△ Less
Submitted 3 October, 2018;
originally announced October 2018.
-
A Proof-of-principle for Time-Of-Flight Positron Emission Tomography Imaging
Authors:
Rajesh Ganai,
Shaifali Mehta,
Mehulkumar Shiroya,
Mitali Mondal,
Zubayer Ahammed,
Subhasis Chattopadhyay
Abstract:
Time-Of-Flight (TOF) is a noble technique that is used in Positron Emission Tomography (PET) imaging worldwide. The scintillator based imaging system that is being used around the world for TOF-PET is very expensive. Multi-gap Resistive Plate Chambers (MRPCs) are gaseous detectors which are easy to fabricate, inexpensive and have excellent position and timing resolution. They can be used as a suit…
▽ More
Time-Of-Flight (TOF) is a noble technique that is used in Positron Emission Tomography (PET) imaging worldwide. The scintillator based imaging system that is being used around the world for TOF-PET is very expensive. Multi-gap Resistive Plate Chambers (MRPCs) are gaseous detectors which are easy to fabricate, inexpensive and have excellent position and timing resolution. They can be used as a suitable alternative to highly expensive scintillators. For the sole purpose of TOF-PET, a pair of 18 cm $\times$ 18 cm, 5 gap, glass-based MRPC modules have been fabricated. Our main aim was to determine the shift in the position of the source (Na-22) with these fabricated MRPCs. In this document, the details of the experimental results will be presented.
△ Less
Submitted 27 June, 2018;
originally announced June 2018.
-
Development and Characterization of 6-gap Bakelite Multi-gap Resistive Plate Chamber
Authors:
Rajesh Ganai,
Mitali Mondal,
Shaifali Mehta,
Zubayer Ahammed,
Subhasis Chattopadhyay
Abstract:
The Multi-gap Resistive Plate Chamber (MRPC) is an advanced form of Resistive Plate Chamber (RPC) detector where the gas gap is divided into sub-gaps. MRPCs are known for their good time resolution and detection efficiency for charged particles. They have found suitable applications in several high energy physics experiments like ALICE in LHC, CERN, Geneva, Switzerland, and STAR in RHIC, BNL, USA.…
▽ More
The Multi-gap Resistive Plate Chamber (MRPC) is an advanced form of Resistive Plate Chamber (RPC) detector where the gas gap is divided into sub-gaps. MRPCs are known for their good time resolution and detection efficiency for charged particles. They have found suitable applications in several high energy physics experiments like ALICE in LHC, CERN, Geneva, Switzerland, and STAR in RHIC, BNL, USA. As they have very good time resolution and are of low cost, they can be a suitable replacement for very expensive scintillators used in Positron Emission Tomography Imaging. The MRPCs that are being used nowadays are developed with glass electrodes. We have made an attempt to develop a 6-gap MRPC using bakelite electrodes. The outer electrodes are of dimensions 15 cm $\times$ 15 cm $\times$ 0.3 cm and the inner electrodes are of dimension 14 cm $\times$ 14 cm $\times$ 0.05 cm. The glossy finished electrode surfaces have not been treated with any oil like linseed, silicone for smoothness. The performance of the detector has been studied measuring the efficiency, noise rate and time resolution with cosmic rays. This effort is towards the development of a prototype for Positron Emission Tomography with the Time-Of-Flight technique using MRPCs. Details of the development procedure and performance studies have been presented here.
△ Less
Submitted 21 June, 2018;
originally announced June 2018.
-
Polarized light imaging of birefringence and diattenuation at highresolution and high sensitivity
Authors:
Shalin B. Mehta,
Michael Shribak,
Rudolf Oldenbourg
Abstract:
Polarized light microscopy provides unique opportunities for analyzing the molecular order in man-made and natural materials, including biological structures inside living cells, tissues, and whole organisms. 20 years ago, the LC-PolScope was introduced as a modern version of the traditional polarizing microscope enhanced by liquid crystal devices for the control of polarization, and by electronic…
▽ More
Polarized light microscopy provides unique opportunities for analyzing the molecular order in man-made and natural materials, including biological structures inside living cells, tissues, and whole organisms. 20 years ago, the LC-PolScope was introduced as a modern version of the traditional polarizing microscope enhanced by liquid crystal devices for the control of polarization, and by electronic imaging and digital image processing for fast and comprehensive image acquisition and analysis. The LC- PolScope is commonly used for birefringence imaging, analyzing the spatial and temporal variations of the differential phase delay in ordered and transparent materials. Here we describe an alternative use of the LC-PolScope for imaging the polarization dependent transmittance of dichroic materials. We explain the minor changes needed to convert the instrument between the two imaging modes, discuss the relationship between the quantities measured with either instrument, and touch on the physical connection between refractive index, birefringence, transmittance, diattenuation, and dichroism.
△ Less
Submitted 29 June, 2013;
originally announced July 2013.
-
Image simulation for biological microscopy: microlith
Authors:
Shalin B. Mehta,
Rudolf Oldenbourg
Abstract:
Image simulation remains under-exploited for the most widely used biological phase microscopy methods, because of difficulties in simulating partially coherent illumination. We describe an open-source toolbox, microlith (https://code.google.com/p/microlith), which accurately predicts three-dimensional images of a thin specimen observed with any partially coherent imaging system, including coherent…
▽ More
Image simulation remains under-exploited for the most widely used biological phase microscopy methods, because of difficulties in simulating partially coherent illumination. We describe an open-source toolbox, microlith (https://code.google.com/p/microlith), which accurately predicts three-dimensional images of a thin specimen observed with any partially coherent imaging system, including coherently illuminated and incoherent, self-luminous specimens. Its accuracy is demonstrated by comparing simulated and experimental bright-field and dark-field images of well-characterized amplitude and phase targets, respectively. The comparison provides new insights about the sensitivity of the dark-field microscope to mass distributions in isolated or periodic specimens at the length-scale of 10nm. Based on predictions using microlith, we propose a novel approach for detecting nanoscale structural changes in a beating axoneme using a dark-field microscope.
△ Less
Submitted 31 March, 2014; v1 submitted 30 May, 2013;
originally announced May 2013.