Dual-energy X-ray dark-field material decomposition
Authors:
Thorsten Sellerer,
Korbinian Mechlem,
Ruizhi Tang,
Kirsten Taphorn,
Franz Pfeiffer,
Julia Herzen
Abstract:
Dual-energy imaging is a clinically well-established technique that offers several advantages over conventional X-ray imaging. By performing measurements with two distinct X-ray spectra, differences in energy-dependent attenuation are exploited to obtain material-specific information. This information is used in various imaging applications to improve clinical diagnosis. In recent years, grating-b…
▽ More
Dual-energy imaging is a clinically well-established technique that offers several advantages over conventional X-ray imaging. By performing measurements with two distinct X-ray spectra, differences in energy-dependent attenuation are exploited to obtain material-specific information. This information is used in various imaging applications to improve clinical diagnosis. In recent years, grating-based X-ray dark-field imaging has received increasing attention in the imaging community. The X-ray dark-field signal originates from ultra small-angle scattering within an object and thus provides information about the microstructure far below the spatial resolution of the imaging system. This property has led to a number of promising future imaging applications that are currently being investigated. However, different microstructures can hardly be distinguished with current X-ray dark-field imaging techniques, since the detected dark-field signal only represents the total amount of ultra small-angle scattering. To overcome these limitations, we present a novel concept called dual-energy X-ray dark-field material decomposition, which transfers the basic material decomposition approach from attenuation-based dual-energy imaging to the dark-field imaging modality. We develop a physical model and algorithms for dual-energy dark-field material decomposition and evaluate the proposed concept in experimental measurements. Our results suggest that by sampling the energy-dependent dark-field signal with two different X-ray spectra, a decomposition into two different microstructured materials is possible. Similar to dual-energy imaging, the additional microstructure-specific information could be useful for clinical diagnosis.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
A theoretical framework for comparing noise characteristics of spectral, differential phase-contrast and spectral differential phase-contrast X-ray imaging
Authors:
Korbinian Mechlem,
Thorsten Sellerer,
Manuel Viermetz,
Julia Herzen,
Franz Pfeiffer
Abstract:
Spectral and grating-based differential phase-contrast X-ray imaging are two emerging technologies that offer additional information compared with conventional attenuation-based X-ray imaging. In the case of spectral imaging, energy-resolved measurements allow the generation of material-specific images by exploiting differences in the energy-dependent attenuation. Differential phase-contrast imagi…
▽ More
Spectral and grating-based differential phase-contrast X-ray imaging are two emerging technologies that offer additional information compared with conventional attenuation-based X-ray imaging. In the case of spectral imaging, energy-resolved measurements allow the generation of material-specific images by exploiting differences in the energy-dependent attenuation. Differential phase-contrast imaging uses the phase shift that an X-ray wave exhibits when traversing an object as contrast generation mechanism. Recently, we have investigated the combination of these two imaging techniques (spectral differential phase-contrast imaging) and demonstrated potential advantages compared with spectral imaging. In this work, we present a noise analysis framework that allows the prediction of (co-) variances and noise power spectra for all three imaging methods. Moreover, the optimum acquisition parameters for a particular imaging task can be determined. We use this framework for a performance comparison of all three imaging methods. The comparison is focused on (projected) electron density images since they can be calculated with all three imaging methods. Our study shows that spectral differential phase-contrast imaging enables the calculation of electron density images with strongly reduced noise levels compared with the other two imaging methods for a large range of clinically relevant pixel sizes. In contrast to conventional differential phase-contrast imaging, there are no long-range noise correlations for spectral differential phase-contrast imaging. This means that excessive low frequency noise can be avoided. We confirm the analytical predictions by numerical simulations.
△ Less
Submitted 17 January, 2020; v1 submitted 2 October, 2019;
originally announced October 2019.