-
Partial-Field Illumination Ophthalmoscope: improving the contrast of a camera-based retinal imager
Authors:
Léa Krafft,
Elena Gofas-Salas,
Yann Lai-Tim,
Michel Paques,
Laurent Mugnier,
Olivier Thouvenin,
Pedro Mecê,
Serge Meimon
Abstract:
Effective and accurate in-vivo diagnosis of retinal pathologies requires high performance imaging devices, combining a large field of view and the ability to discriminate the ballistic signal from the diffuse background in order to provide a highly contrasted image of the retinal structures. Here, we have implemented the Partial-Field Illumination Ophthalmoscope, a patterned illumination modality,…
▽ More
Effective and accurate in-vivo diagnosis of retinal pathologies requires high performance imaging devices, combining a large field of view and the ability to discriminate the ballistic signal from the diffuse background in order to provide a highly contrasted image of the retinal structures. Here, we have implemented the Partial-Field Illumination Ophthalmoscope, a patterned illumination modality, integrated on a high pixel rate adaptive optics full-field microscope. This non-invasive technique enables us to mitigate the low signal-to-noise ratio, intrinsic of full-field ophthalmoscopes, by partially illuminating the retina with complementary patterns to reconstruct a wide field image. This new modality provides an image contrast spanning from the full-field to the confocal contrast, depending on the pattern size. As a result, it offers various trade-offs in terms of contrast and acquisition speed, guiding the users towards the most efficient system for a particular clinical application.
△ Less
Submitted 2 September, 2021;
originally announced September 2021.
-
Manifestation of aberrations in full-field optical coherence tomography
Authors:
Victor Barolle,
Jules Scholler,
Pedro Mecê,
Jean-Marie Chassot,
Kassandra Groux,
Mathias Fink,
A. Claude Boccara,
Alexandre Aubry
Abstract:
We report on a theoretical model for image formation in full-field optical coherence tomography (FFOCT). Because the spatial incoherence of the illumination acts as a virtual confocal pinhole in FFOCT, its imaging performance is equivalent to a scanning time-gated coherent confocal microscope. In agreement with optical experiments enabling a precise control of aberrations, FFOCT is shown to have n…
▽ More
We report on a theoretical model for image formation in full-field optical coherence tomography (FFOCT). Because the spatial incoherence of the illumination acts as a virtual confocal pinhole in FFOCT, its imaging performance is equivalent to a scanning time-gated coherent confocal microscope. In agreement with optical experiments enabling a precise control of aberrations, FFOCT is shown to have nearly twice the resolution of standard imaging at moderate aberration level. Beyond a rigorous study on the sensitivity of FFOCT with respect to aberrations, this theoretical model paves the way towards an optimized design of adaptive optics and \rev{computational tools} for high-resolution and deep imaging of biological tissues.
△ Less
Submitted 2 July, 2021; v1 submitted 25 January, 2021;
originally announced January 2021.
-
Super-resolution in vivo retinal imaging using structured illumination ophthalmoscopy
Authors:
Yann Lai-Tim,
Laurent Mugnier,
Léa Krafft,
Antoine Chen,
Cyril Petit,
Pedro Mecê,
Kate Grieve,
Michel Paques,
Serge Meimon
Abstract:
Structured illumination microscopy (SIM) is one of the most versatile super-resolution techniques. Yet, its application to live imaging has been so far mainly limited to fluorescent and stationary specimens. Here, we present advancements in SIM to jointly tackle all the challenges of imaging living samples, i.e., obtaining super-resolution over an undistorted wide-field while dealing with sample m…
▽ More
Structured illumination microscopy (SIM) is one of the most versatile super-resolution techniques. Yet, its application to live imaging has been so far mainly limited to fluorescent and stationary specimens. Here, we present advancements in SIM to jointly tackle all the challenges of imaging living samples, i.e., obtaining super-resolution over an undistorted wide-field while dealing with sample motion, scattering, sample-induced optical aberrations and low signal-to-noise ratio. By using adaptive optics to compensate for optical aberrations and a reconstruction algorithm tailored for a moving and thick tissue, we successfully applied SIM to in vivo retinal imaging and demonstrated structured illumination ophthalmoscopy for high contrast super-resolution in vivo imaging of the human retina.
△ Less
Submitted 15 October, 2020; v1 submitted 30 July, 2020;
originally announced July 2020.
-
Adaptive-glasses wavefront sensorless full-field OCT for high-resolution retinal imaging over a wide field-of-view
Authors:
Jules Scholler,
Kassandra Groux,
Kate Grieve,
Claude Boccara,
Pedro Mecê
Abstract:
The highest three-dimensional (3D) resolution possible in in-vivo retinal imaging is achieved by combining optical coherence tomography (OCT) and adaptive optics (AO). However, this combination brings important limitations, such as small field-of-view and complex, cumbersome systems, preventing so far the translation of this technology from the research lab to clinics. In this Letter, we introduce…
▽ More
The highest three-dimensional (3D) resolution possible in in-vivo retinal imaging is achieved by combining optical coherence tomography (OCT) and adaptive optics (AO). However, this combination brings important limitations, such as small field-of-view and complex, cumbersome systems, preventing so far the translation of this technology from the research lab to clinics. In this Letter, we introduce an approach that avoids these limitations by using a multi-actuator adaptive lens just in front of the eye, in a technique we call the adaptive-glasses wavefront sensorless approach. We implemented this approach on our compact full-field OCT (FFOCT) retinal imager without increasing its footprint or optical complexity. The correction of ocular aberrations through the adaptive-glasses approach increased the FFOCT signal-to-noise ratio and enabled us to image different retinal layers with a 3D cellular resolution in a 5° $\times$ 5° field-of-view, without apparent anisoplanatism.
△ Less
Submitted 9 July, 2020;
originally announced July 2020.
-
Optical Incoherence Tomography: a method to generate tomographic retinal cross-sections with non-interferometric imaging systems
Authors:
Pedro Mecê,
Elena Gofas-Salas,
Michel Paques,
Kate Grieve,
Serge Meimon
Abstract:
Optical tomographic cross-sectional images of biological samples were made possible by interferometric imaging techniques such as Optical Coherence Tomography (OCT). Owing to its unprecedented view of the sample, OCT has become a gold standard, namely for human retinal imaging in the clinical environment. In this Letter, we present Optical Incoherence Tomography (OIT): a completely digital method…
▽ More
Optical tomographic cross-sectional images of biological samples were made possible by interferometric imaging techniques such as Optical Coherence Tomography (OCT). Owing to its unprecedented view of the sample, OCT has become a gold standard, namely for human retinal imaging in the clinical environment. In this Letter, we present Optical Incoherence Tomography (OIT): a completely digital method extending the possibility to generate tomographic retinal cross-sections to non-interferometric imaging systems such as en-face AO-ophthalmoscopes. We demonstrate that OIT can be applied to different imaging modalities using back-scattered and multiply-scattered light including systems without inherent optical sectioning. We show that OIT can be further used to guide focus position when the user is "blind" focusing, allowing precise imaging of translucent retinal structures, the vascular plexuses and the retinal pigment epithelium using respectively split detection, motion contrast, and autofluorescence techniques.
△ Less
Submitted 27 February, 2020;
originally announced February 2020.
-
Curved-Full-Field OCT for high-resolution imaging of living human retina over a large field-of-view
Authors:
Pedro Mecê,
Kassandra Groux,
Jules Scholler,
Olivier Thouvenin,
Mathias Fink,
Kate Grieve,
Claude Boccara
Abstract:
Allying high-resolution with a large field-of-view (FOV) is of great importance in the fields of biology and medicine, but particularly challenging when imaging non-flat living samples such as the human retina. Indeed, high-resolution is normally achieved with adaptive optics (AO) and scanning methods, which considerably reduce the useful FOV and increase the system complexity. An alternative tech…
▽ More
Allying high-resolution with a large field-of-view (FOV) is of great importance in the fields of biology and medicine, but particularly challenging when imaging non-flat living samples such as the human retina. Indeed, high-resolution is normally achieved with adaptive optics (AO) and scanning methods, which considerably reduce the useful FOV and increase the system complexity. An alternative technique is time-domain Full-Field Optical Coherence Tomography (FF-OCT), which has already shown its potential for in-vivo high-resolution retinal imaging. Here, we introduce curved-field FF-OCT, capable of matching the coherence gate geometry to the sample curvature, thus achieving a larger FOV than previously possible. Using this instrument, we obtained high-resolution images of living human photoreceptors close to the foveal center without AO and with a 1 mm x 1 mm FOV in a single shot. This novel advance enables the extraction of photoreceptor-based biomarkers with ease and spatiotemporal monitoring of individual photoreceptors. We compare our findings with AO-assisted ophthalmoscopes, highlighting the potential of FF-OCT, as a relatively simple, compact and low-cost system, to become a routine clinical imaging technique.
△ Less
Submitted 19 January, 2020;
originally announced January 2020.