-
Self-Organized Pattern Formation in Geological Soft Matter
Authors:
Julyan H. E. Cartwright,
Charles S. Cockell,
Lucas Goehring,
Silvia Holler,
Sean F. Jordan,
Pamela Knoll,
Electra Kotopoulou,
Corentin C. Loron,
Sean McMahon,
Stephen W. Morris,
Anna Neubeck,
Carlos Pimentel,
C. Ignacio Sainz-Díaz,
Noushine Shahidzadeh,
Piotr Szymczak
Abstract:
Geological materials are often seen as the antithesis of soft; rocks are hard. However, during the formation of minerals and rocks, all the systems we shall discuss, indeed geological materials in general, pass through a stage where they are soft. This occurs either because they are at a high temperature -- igneous or metamorphic rock -- or because they are at a lower temperature but in the presen…
▽ More
Geological materials are often seen as the antithesis of soft; rocks are hard. However, during the formation of minerals and rocks, all the systems we shall discuss, indeed geological materials in general, pass through a stage where they are soft. This occurs either because they are at a high temperature -- igneous or metamorphic rock -- or because they are at a lower temperature but in the presence of water -- sedimentary rock. For this reason it is useful to introduce soft-matter concepts into the geological domain. There is a universality in the diverse instances of geological patterns that may be appreciated by looking at the common aspect in their formation of having passed through a stage as soft matter.
△ Less
Submitted 25 December, 2024;
originally announced December 2024.
-
Single-pulse Gy-scale irradiation of biological cells at $10^{13}$ Gy/s average dose-rates from a laser-wakefield accelerator
Authors:
C. A. McAnespie,
P. Chaudhary,
M. J. V. Streeter,
S. W. Botchway,
N. Bourgeois,
L. Calvin,
N. Cavanagh,
K. Fleck,
D. Jaroszynski,
B. Kettle,
A. M. Lupu,
S. P. D. Mangles,
S. J. McMahon,
J. Mill,
S. R. Needham,
P. P. Rajeev,
J. Sarma,
K. M. Prise,
G. Sarri
Abstract:
We report on the first experimental characterization of a laser-wakefield accelerator able to deliver, in a single pulse, doses in excess of \unit[1]{Gy} on timescales of the order of a hundred femtoseconds, reaching unprecedented average dose-rates up to \unit[10$^{13}$]{Gy/s}. The irradiator is demonstrated to deliver doses tuneable up to \unit[2.2]{Gy} in a cm$^2$ area and with a high degree of…
▽ More
We report on the first experimental characterization of a laser-wakefield accelerator able to deliver, in a single pulse, doses in excess of \unit[1]{Gy} on timescales of the order of a hundred femtoseconds, reaching unprecedented average dose-rates up to \unit[10$^{13}$]{Gy/s}. The irradiator is demonstrated to deliver doses tuneable up to \unit[2.2]{Gy} in a cm$^2$ area and with a high degree of longitudinal and transverse uniformity in a single irradiation. In this regime, proof-of-principle irradiation of patient-derived glioblastoma stem-like cells and human skin fibroblast cells show indications of a differential cellular response, when compared to reference irradiations at conventional dose-rates. These include a statistically significant increase in relative biological effectiveness ($1.40\pm0.08$ at 50\% survival for both cell lines) and a significant reduction of the relative radioresistance of tumour cells. Data analysis provides preliminary indications that these effects might not be fully explained by induced oxygen depletion in the cells but may be instead linked to a higher complexity of the damages triggered by the ultra-high density of ionising tracks of femtosecond-scale radiation pulses. These results demonstrate an integrated platform for systematic radiobiological studies at unprecedented beam durations and dose-rates, a unique infrastructure for translational research in radiobiology at the femtosecond scale.
△ Less
Submitted 19 November, 2024; v1 submitted 3 September, 2024;
originally announced September 2024.
-
Laser-driven electron source suitable for single-shot Gy-scale irradiation of biological cells at dose-rates exceeding $10^{10}$ Gy/s
Authors:
C. A. McAnespie,
P. Chaudhary,
L. Calvin,
M. J. V. Streeter,
G. Nersysian,
S. J. McMahon,
K. M. Prise,
G. Sarri
Abstract:
We report on the first systematic characterisation of a tuneable laser-driven electron source capable of delivering Gy-scale doses in a duration of 10 - 20 ps, thus reaching unprecedented dose rates in the range of $10^{10} - 10^{12}$ Gy/s. Detailed characterisation of the source indicates, in agreement with Monte-Carlo simulations, single-shot delivery of multi-Gy doses per pulse over cm-scale ar…
▽ More
We report on the first systematic characterisation of a tuneable laser-driven electron source capable of delivering Gy-scale doses in a duration of 10 - 20 ps, thus reaching unprecedented dose rates in the range of $10^{10} - 10^{12}$ Gy/s. Detailed characterisation of the source indicates, in agreement with Monte-Carlo simulations, single-shot delivery of multi-Gy doses per pulse over cm-scale areas, with a high degree of spatial uniformity. The results reported here confirm that a laser-driven source of this kind can be used for systematic studies of the response of biological cells to picosecond-scale radiation at ultra-high dose rates.
△ Less
Submitted 13 September, 2023;
originally announced September 2023.
-
A new Standard DNA damage (SDD) data format
Authors:
J. Schuemann,
A. McNamara,
J. W. Warmenhoven,
N. T. Henthorn,
K. Kirkby,
M. J. Merchant,
S. Ingram,
H. Paganetti,
KD. Held,
J. Ramos-Mendez,
B. Faddegon,
J. Perl,
D. Goodhead,
I. Plante,
H. Rabus,
H. Nettelbeck,
W. Friedland,
P. Kundrat,
A. Ottolenghi,
G. Baiocco,
S. Barbieri,
M. Dingfelder,
S. Incerti,
C. Villagrasa,
M. Bueno
, et al. (26 additional authors not shown)
Abstract:
Our understanding of radiation induced cellular damage has greatly improved over the past decades. Despite this progress, there are still many obstacles to fully understanding how radiation interacts with biologically relevant cellular components to form observable endpoints. One hurdle is the difficulty faced by members of different research groups in directly comparing results. Multiple Monte Ca…
▽ More
Our understanding of radiation induced cellular damage has greatly improved over the past decades. Despite this progress, there are still many obstacles to fully understanding how radiation interacts with biologically relevant cellular components to form observable endpoints. One hurdle is the difficulty faced by members of different research groups in directly comparing results. Multiple Monte Carlo codes have been developed to simulate damage induction at the DNA scale, while at the same time various groups have developed models that describe DNA repair processes with varying levels of detail. These repair models are intrinsically linked to the damage model employed in their development, making it difficult to disentangle systematic effects in either part of the modelling chain. The modelling chain typically consists of track structure Monte Carlo simulations of the physics interactions creating direct damages to the DNA; followed by simulations of the production and initial reactions of chemical species causing indirect damages. After the DNA damage induction, DNA repair models combine the simulated damage patterns with biological models to determine the biological consequences of the damage. We propose a new Standard data format for DNA Damage to unify the interface between the simulation of damage induction and the biological modelling of cell repair processes. Such a standard greatly facilitates inter model comparisons, providing an ideal environment to tease out model assumptions and identify persistent, underlying mechanisms. Through inter model comparisons, this unified standard has the potential to greatly advance our understanding of the underlying mechanisms of radiation induced DNA damage and the resulting observable biological effects.
△ Less
Submitted 11 January, 2022;
originally announced January 2022.
-
Complexity-weighted doses reduce biological uncertainty in proton radiotherapy planning
Authors:
Stephen J McMahon,
Harald Paganetti,
Kevin M Prise
Abstract:
Purpose: Variations in proton Relative Biological Effectiveness (RBE) with Linear Energy Transfer (LET) remain one of the largest sources of uncertainty in proton radiotherapy. This work seeks to identify physics-based metrics which can be applied to reduce this biological uncertainty.
Materials and Methods: Three different physical metrics - dose, dose $\times$ LET and a complexity-weighted dos…
▽ More
Purpose: Variations in proton Relative Biological Effectiveness (RBE) with Linear Energy Transfer (LET) remain one of the largest sources of uncertainty in proton radiotherapy. This work seeks to identify physics-based metrics which can be applied to reduce this biological uncertainty.
Materials and Methods: Three different physical metrics - dose, dose $\times$ LET and a complexity-weighted dose (CWD, Dose $\times$ (1+$κLET_D$) ) were compared with in vitro experimental studies of proton RBE and clinical treatment plans analysed using RBE models. The biological effects of protons in each system were plotted against these metrics to quantify the degree of biological uncertainty introduced by RBE variations in each case.
Results: When the biological effects of protons were plotted against dose alone, significant biological uncertainty was introduced as the LET-dependence of RBE was neglected. Plotting biological effects against dose $\times$ LET significantly over-estimated the impact of LET on cell survival, leading to similar or greater levels of biological uncertainty. CWD, by contrast, significantly reduced biological uncertainties in both experiments and clinical plans. For prostate and medulloblastoma treatment plans, biological uncertainties were reduced from $\pm$ 5% to less than 1%.
Conclusions: While not a replacement for full RBE models, physics-based metrics such as CWD have the potential to significantly reduce the uncertainties in proton planning which result from variations in RBE. These metrics may be used to identify regions in normal tissues which may see unexpectedly high effects due to end-of-range elevations of RBE, or as a tool in optimisation to deliver uniform biological effects.
△ Less
Submitted 19 February, 2018;
originally announced February 2018.
-
Optimising Element Choice for Nanoparticle Radiosensitisers
Authors:
Stephen J. McMahon,
Harald Paganetti,
Kevin M. Prise
Abstract:
There is considerable interest in the use of heavy atom nanoparticles as theranostic contrast agents due to their high radiation cross-section compared to soft tissue. However, published studies have primarily focused on applications of gold nanoparticles. This study applies Monte Carlo radiation transport modelling using Geant4 to evaluate the macro- and micro-scale radiation dose enhancement fol…
▽ More
There is considerable interest in the use of heavy atom nanoparticles as theranostic contrast agents due to their high radiation cross-section compared to soft tissue. However, published studies have primarily focused on applications of gold nanoparticles. This study applies Monte Carlo radiation transport modelling using Geant4 to evaluate the macro- and micro-scale radiation dose enhancement following X-ray irradiation with both imaging and therapeutic energies on nanoparticles consisting of stable elements heavier than silicon. An approach based on the Local Effect Model was also used to assess potential biological impacts. While macroscopic dose enhancement is well predicted by simple absorption cross-sections, nanoscale dose deposition has a much more complex dependency on atomic number, with local maxima around germanium (Z=32) and gadolinium (Z=64), driven by variations in secondary Auger electron spectra, which translate into significant variations in biological effectiveness. These differences may provide a valuable tool for predicting and elucidating fundamental mechanisms of these agents as they move towards clinical application.
△ Less
Submitted 29 September, 2015;
originally announced September 2015.
-
Development of a custom on-line ultrasonic vapour analyzer/flowmeter for the ATLAS inner detector, with application to gaseous tracking and Cherenkov detectors
Authors:
R. Bates,
M. Battistin,
S. Berry,
J. Berthoud,
A. Bitadze,
P. Bonneau,
J. Botelho-Direito,
N. Bousson,
G. Boyd,
G. Bozza,
E. Da Riva,
C. Degeorge,
B. DiGirolamo,
M. Doubek,
J. Godlewski,
G. Hallewell,
S. Katunin,
D. Lombard,
M. Mathieu,
S. McMahon,
K. Nagai,
E. Perez-Rodriguez,
C. Rossi,
A. Rozanov,
V. Vacek
, et al. (2 additional authors not shown)
Abstract:
Precision sound velocity measurements can simultaneously determine binary gas composition and flow. We have developed an analyzer with custom electronics, currently in use in the ATLAS inner detector, with numerous potential applications. The instrument has demonstrated ~0.3% mixture precision for C3F8/C2F6 mixtures and < 10-4 resolution for N2/C3F8 mixtures. Moderate and high flow versions of the…
▽ More
Precision sound velocity measurements can simultaneously determine binary gas composition and flow. We have developed an analyzer with custom electronics, currently in use in the ATLAS inner detector, with numerous potential applications. The instrument has demonstrated ~0.3% mixture precision for C3F8/C2F6 mixtures and < 10-4 resolution for N2/C3F8 mixtures. Moderate and high flow versions of the instrument have demonstrated flow resolutions of +/- 2% F.S. for flows up to 250 l.min-1, and +/- 1.9% F.S. for linear flow velocities up to 15 ms-1; the latter flow approaching that expected in the vapour return of the thermosiphon fluorocarbon coolant recirculator being built for the ATLAS silicon tracker.
△ Less
Submitted 30 October, 2012;
originally announced October 2012.
-
A combined ultrasonic flow meter and binary vapour mixture analyzer for the ATLAS silicon tracker
Authors:
R. Bates,
M. Battistin,
S. Berry,
J. Berthoud,
A. Bitadze,
P. Bonneau,
J. Botelho-Direito,
N. Bousson,
G. Boyd,
G. Bozza,
E. Da Riva,
C. Degeorge,
B. DiGirolamo,
M. Doubek,
D. Giugni,
J. Godlewski,
G. Hallewell,
S. Katunin,
D. Lombard,
M. Mathieu,
S. McMahon,
K. Nagai,
E. Perez-Rodriguez,
C. Rossi,
A. Rozanov
, et al. (3 additional authors not shown)
Abstract:
An upgrade to the ATLAS silicon tracker cooling control system may require a change from C3F8 (octafluoro-propane) evaporative coolant to a blend containing 10-25% of C2F6 (hexafluoro-ethane). Such a change will reduce the evaporation temperature to assure thermal stability following radiation damage accumulated at full LHC luminosity. Central to this upgrade is a new ultrasonic instrument in whic…
▽ More
An upgrade to the ATLAS silicon tracker cooling control system may require a change from C3F8 (octafluoro-propane) evaporative coolant to a blend containing 10-25% of C2F6 (hexafluoro-ethane). Such a change will reduce the evaporation temperature to assure thermal stability following radiation damage accumulated at full LHC luminosity. Central to this upgrade is a new ultrasonic instrument in which sound transit times are continuously measured in opposite directions in flowing gas at known temperature and pressure to deduce the C3F8/C2F6 flow rate and mixture composition. The instrument and its Supervisory, Control and Data Acquisition (SCADA) software are described in this paper. Several geometries for the instrument are in use or under evaluation. An instrument with a pinched axial geometry intended for analysis and measurement of moderate flow rates has demonstrated a mixture resolution of 3.10-3 for C3F8/C2F6 molar mixtures with 20%C2F6, and a flow resolution of 2% of full scale for mass flows up to 30gs-1. In mixtures of widely-differing molecular weight (mw), higher mixture precision is possible: a sensitivity of <5.10-5 to leaks of C3F8 into part of the ATLAS tracker nitrogen envelope (mw difference 160) has been seen. An instrument with an angled sound path geometry has been developed for use at high fluorocarbon mass flow rates of around 1.2 kgs-1 - corresponding to full flow in a new 60kW thermosiphon recirculator under construction for the ATLAS silicon tracker. Extensive computational fluid dynamics studies were performed to determine the preferred geometry (ultrasonic transducer spacing and placement, together with the sound crossing angle with respect to the vapour flow direction). A prototype with 45deg crossing angle has demonstrated a flow resolution of 1.9% of full scale for linear flow velocities up to 15 ms-1. The instrument has many potential applications.
△ Less
Submitted 17 October, 2012;
originally announced October 2012.
-
A Combine On-Line Acoustic Flowmeter and Fluorocarbon Coolant Mixture Analyzer for The ATLAS Silicon Tracker
Authors:
A. Bitadze,
R. Bates,
M. Battistin,
S. Berry,
P. Bonneau,
J. Botelho-Direito,
B. DiGirolamo,
J. Godlewski,
E. Perez-Rodriguez,
L. Zwalinski,
N. Bousson,
G. Hallewell,
M. Mathieu,
A. Rozanov,
G. Boyd,
M. Doubek,
V. Vacek,
M. Vitek,
K. Egorov,
S. Katunin,
S. McMahon,
K. Nagai
Abstract:
An upgrade to the ATLAS silicon tracker cooling control system may require a change from C3F8 (octafluoro-propane) to a blend containing 10-30% of C2F6 (hexafluoro-ethane) to reduce the evaporation temperature and better protect the silicon from cumulative radiation damage with increasing LHC luminosity. Central to this upgrade is a new acoustic instrument for the real-time measurement of the C3F8…
▽ More
An upgrade to the ATLAS silicon tracker cooling control system may require a change from C3F8 (octafluoro-propane) to a blend containing 10-30% of C2F6 (hexafluoro-ethane) to reduce the evaporation temperature and better protect the silicon from cumulative radiation damage with increasing LHC luminosity. Central to this upgrade is a new acoustic instrument for the real-time measurement of the C3F8/C2F6 mixture ratio and flow. The instrument and its Supervisory, Control and Data Acquisition (SCADA) software are described in this paper. The instrument has demonstrated a resolution of 3.10-3 for C3F8/C2F6 mixtures with ~20%C2F6, and flow resolution of 2% of full scale for mass flows up to 30gs-1. In mixtures of widely-differing molecular weight (mw), higher mixture precision is possible: a sensitivity of < 5.10-4 to leaks of C3F8 into the ATLAS pixel detector nitrogen envelope (mw difference 160) has been seen. The instrument has many potential applications, including the analysis of mixtures of hydrocarbons, vapours for semi-conductor manufacture and anaesthesia.
△ Less
Submitted 12 January, 2012;
originally announced January 2012.