-
Identification and Removal of System-Induced Autofluorescence in Miniaturized Fiber-optic Fluorescence Endoscopes
Authors:
Lei Xiang,
Rouyan Chen,
Joanne Tan,
Victoria Nankivell,
Christina A. Bursill,
Robert A. McLaughlin,
Jiawen Li
Abstract:
Miniaturized fiber-optic fluorescence endoscopes play a crucial role in medical diagnostics and research, but system-induced autofluorescence remains a significant challenge, particularly in single-fiber setups. While recent advances, such as double-clad fiber (DCF) and DCF couplers, have reduced background noise, complete elimination remains challenging. Research on the various sources of system-…
▽ More
Miniaturized fiber-optic fluorescence endoscopes play a crucial role in medical diagnostics and research, but system-induced autofluorescence remains a significant challenge, particularly in single-fiber setups. While recent advances, such as double-clad fiber (DCF) and DCF couplers, have reduced background noise, complete elimination remains challenging. Research on the various sources of system-induced autofluorescence and the methods to remove them are scarce. This study seeks to fulfill this need by proposing practical approaches to removal of system-induced autofluorescence. This study presents the methods to suppress static background noise and proposes an algorithm based on least-squares linear spectral unmixing to remove variable system-induced autofluorescence artifacts. The algorithm was evaluated on a single-fiber DCF intravascular imaging system, with phantom and rodent in vivo experiments confirming its effectiveness. Results showed accurate differentiation between true sample fluorescence and system-induced autofluorescence artifacts through the validation with optical coherence tomography images and histology results, further verified by statistical analysis. Unlike simple background subtraction, the method addresses dynamic variations in background noise and incidental artifacts, providing robust performance under varying conditions. Our method may be adapted to various fiber-based endoscopy setups and be compatible with different fluorescent agents and autofluorescence imaging, broadening its applicability in biomedical imaging.
△ Less
Submitted 10 March, 2025;
originally announced March 2025.
-
Continuous Phase-Shifting Holography Utilizing a Moving Diffraction Grating
Authors:
G. S. Kalenkov,
S. G. Kalenkov,
A. E. Shtanko,
B. C. Quirk,
R. A. Mclaughlin
Abstract:
Fabrication of optical coherence tomography (OCT) fiber probes in cardiology involves sequentially splicing and cleaving multiple fibers to form a lens. During this process, the splice location-normally invisible under standard illumination-must be identified with micron-level accuracy. This paper presents an approach for splice detection using digital lensless microscopy, which is well-suited for…
▽ More
Fabrication of optical coherence tomography (OCT) fiber probes in cardiology involves sequentially splicing and cleaving multiple fibers to form a lens. During this process, the splice location-normally invisible under standard illumination-must be identified with micron-level accuracy. This paper presents an approach for splice detection using digital lensless microscopy, which is well-suited for deployment within the restricted space constraints typically found in fiber-fabrication setups. The optical setup incorporates a movable Ronchi grating that simultaneously acts as a beam splitter and a phase modulator. This design enables spatial separation of the reference and object beams while preserving the inherent stability of common-path interferometry. The acquired hologram set is processed using the continuous phase-shifting technique, which is known for its robustness against phase-shifting errors. The theoretical foundations for recording such holograms have been developed, and the conditions under which background noise and the conjugate order are suppressed have been identified. Experiments demonstrated the acquisition of high-contrast quantitative phase images of fiber splices with a spatial resolution down to 1 $μm$.
△ Less
Submitted 27 February, 2025;
originally announced February 2025.
-
3D-printed axicon enables extended depth-of-focus intravascular optical coherence tomography
Authors:
Pavel Ruchka,
Alok Kushwaha,
Jessica A. Marathe,
Lei Xiang,
Rouyan Chen,
Rodney Kirk,
Joanne T. M. Tan,
Christina A. Bursill,
Johan Verjans,
Simon Thiele,
Robert Fitridge,
Robert A. McLaughlin,
Peter J. Psaltis,
Harald Giessen,
Jiawen Li
Abstract:
A fundamental challenge in endoscopy is how to fabricate a small fiber-optic probe that can achieve comparable function to probes with large, complicated optics (e.g., high resolution and extended depth of focus). To achieve high resolution over an extended depth of focus (DOF), the application of needle-like beams has been proposed. However, existing methods using miniaturized needle beam designs…
▽ More
A fundamental challenge in endoscopy is how to fabricate a small fiber-optic probe that can achieve comparable function to probes with large, complicated optics (e.g., high resolution and extended depth of focus). To achieve high resolution over an extended depth of focus (DOF), the application of needle-like beams has been proposed. However, existing methods using miniaturized needle beam designs fail to adequately correct astigmatism and other monochromatic aberrations, limiting the resolution of at least one axis. Here, we describe a novel approach to realize freeform beam-shaping endoscopic probes via two-photon direct laser writing, also known as micro 3D-printing. We present a design achieving approximately 8-micron resolution with a DOF of >0.8 mm at a central wavelength of 1310 nm. The probe has a diameter of 0.25 mm (without the catheter sheaths) and is fabricated using a single printing step directly on the optical fiber. We demonstrate our device in intravascular imaging of living atherosclerotic pigs at multiple time points, as well as human arteries with plaques ex vivo. This is the first step to enable beam-tailoring endoscopic probes which achieve diffraction-limited resolution over a large DOF.
△ Less
Submitted 20 July, 2024;
originally announced July 2024.
-
Continuous spatial field confocal thermometry using lanthanide doped tellurite glass
Authors:
D. Stavrevski,
E. Schartner,
I. S. Maksymov,
R. A. McLaughlin,
Heike Ebendorff-Heidepriem,
A. D. Greentree
Abstract:
Quantifying temperature variations at the micron scale can provide new opportunities in optical sensing. In this paper, we present a novel approach using the temperature-dependent variations in fluorescence of rare-earth doped tellurite glass to provide a micron-scale image of temperature variations over a 200 micrometre field of view. We demonstrate the system by monitoring the evaporation of a w…
▽ More
Quantifying temperature variations at the micron scale can provide new opportunities in optical sensing. In this paper, we present a novel approach using the temperature-dependent variations in fluorescence of rare-earth doped tellurite glass to provide a micron-scale image of temperature variations over a 200 micrometre field of view. We demonstrate the system by monitoring the evaporation of a water droplet and report a net temperature change of 7.04 K with a sensitivity of at least 0.12 K. These results establish the practicality of this confocal-based approach to provide high-resolution marker-free optical temperature sensing.
△ Less
Submitted 12 February, 2020;
originally announced February 2020.