-
High-Sensitivity Fiber Interferometer for Gravitational Phase Shift Measurement on Entangled States
Authors:
Eleonora Polini,
Piotr Chruściel,
Georgi Dvali,
Christopher Hilweg,
Begüm Kabagöz,
Dorotea Macri,
Thomas Mieling,
Thomas Morling,
Eric Oelker,
Elisabeth Steininger,
Xinghui Yin,
Haocun Yu,
Sebastian Zell,
Tongxuan Zhang,
Nergis Mavalvala,
Philip Walther
Abstract:
In this contribution, we describe the status of our experiment aimed at measuring the gravitationally induced phase shift on path-entangled photons. We use a kilometer-scale fiber interferometer whose arms are vertically displaced in the Earth gravitational potential, allowing photons propagating at different heights to accumulate different phases. To date, this is the first experiment to measure…
▽ More
In this contribution, we describe the status of our experiment aimed at measuring the gravitationally induced phase shift on path-entangled photons. We use a kilometer-scale fiber interferometer whose arms are vertically displaced in the Earth gravitational potential, allowing photons propagating at different heights to accumulate different phases. To date, this is the first experiment to measure this effect on massless particles, thereby experimentally combining general relativity and quantum mechanics.
△ Less
Submitted 25 June, 2025; v1 submitted 11 June, 2025;
originally announced June 2025.
-
A Trade-Off Between Path Entanglement and Quantum Sensitivity
Authors:
Benjamin Lou,
Hudson A. Loughlin,
Nergis Mavalvala
Abstract:
Entanglement often increases quantum measurement schemes' sensitivity. However, we find that in precision measurements with zero-mean Gaussian states, such as squeezed states, entanglement between different paths degrades measurement sensitivity. We prove an inverse relationship between entanglement entropy and sensitivity for measurements of single-mode phase shifts in multimode systems and for p…
▽ More
Entanglement often increases quantum measurement schemes' sensitivity. However, we find that in precision measurements with zero-mean Gaussian states, such as squeezed states, entanglement between different paths degrades measurement sensitivity. We prove an inverse relationship between entanglement entropy and sensitivity for measurements of single-mode phase shifts in multimode systems and for phase shifts on both modes in two-mode systems. In the two-mode case, which models devices such as interferometers, we find that entanglement strongly degrades differential phase sensitivity. Finally, we show that minimizing entanglement between paths maximizes the phase sensitivity of $N$-mode systems with zero-mean Gaussian state inputs.
△ Less
Submitted 24 April, 2025; v1 submitted 27 November, 2024;
originally announced November 2024.
-
Advanced LIGO detector performance in the fourth observing run
Authors:
E. Capote,
W. Jia,
N. Aritomi,
M. Nakano,
V. Xu,
R. Abbott,
I. Abouelfettouh,
R. X. Adhikari,
A. Ananyeva,
S. Appert,
S. K. Apple,
K. Arai,
S. M. Aston,
M. Ball,
S. W. Ballmer,
D. Barker,
L. Barsotti,
B. K. Berger,
J. Betzwieser,
D. Bhattacharjee,
G. Billingsley,
S. Biscans,
C. D. Blair,
N. Bode,
E. Bonilla
, et al. (171 additional authors not shown)
Abstract:
On May 24th, 2023, the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO), joined by the Advanced Virgo and KAGRA detectors, began the fourth observing run for a two-year-long dedicated search for gravitational waves. The LIGO Hanford and Livingston detectors have achieved an unprecedented sensitivity to gravitational waves, with an angle-averaged median range to binary neutron st…
▽ More
On May 24th, 2023, the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO), joined by the Advanced Virgo and KAGRA detectors, began the fourth observing run for a two-year-long dedicated search for gravitational waves. The LIGO Hanford and Livingston detectors have achieved an unprecedented sensitivity to gravitational waves, with an angle-averaged median range to binary neutron star mergers of 152 Mpc and 160 Mpc, and duty cycles of 65.0% and 71.2%, respectively, with a coincident duty cycle of 52.6%. The maximum range achieved by the LIGO Hanford detector is 165 Mpc and the LIGO Livingston detector 177 Mpc, both achieved during the second part of the fourth observing run. For the fourth run, the quantum-limited sensitivity of the detectors was increased significantly due to the higher intracavity power from laser system upgrades and replacement of core optics, and from the addition of a 300 m filter cavity to provide the squeezed light with a frequency-dependent squeezing angle, part of the A+ upgrade program. Altogether, the A+ upgrades led to reduced detector-wide losses for the squeezed vacuum states of light which, alongside the filter cavity, enabled broadband quantum noise reduction of up to 5.2 dB at the Hanford observatory and 6.1 dB at the Livingston observatory. Improvements to sensors and actuators as well as significant controls commissioning increased low frequency sensitivity. This paper details these instrumental upgrades, analyzes the noise sources that limit detector sensitivity, and describes the commissioning challenges of the fourth observing run.
△ Less
Submitted 21 November, 2024;
originally announced November 2024.
-
Quantum Metrology for Gravitational Wave Astronomy
Authors:
Roman Schnabel,
Nergis Mavalvala,
David E. McClelland,
Ping Koy Lam
Abstract:
Einstein's General Theory of Relativity predicts that accelerating mass distributions produce gravitational radiation, analogous to electromagnetic radiation from accelerating charges. These gravitational waves have not been directly detected to date, but are expected to open a new window to the Universe in the near future. Suitable telescopes are kilometre-scale laser interferometers measuring th…
▽ More
Einstein's General Theory of Relativity predicts that accelerating mass distributions produce gravitational radiation, analogous to electromagnetic radiation from accelerating charges. These gravitational waves have not been directly detected to date, but are expected to open a new window to the Universe in the near future. Suitable telescopes are kilometre-scale laser interferometers measuring the distance between quasi free-falling mirrors. Recent advances in quantum metrology may now provide the required sensitivity boost. So-called squeezed light is able to quantum entangle the high-power laser fields in the interferometer arms, and could play a key role in the realization of gravitational wave astronomy.
△ Less
Submitted 11 November, 2024;
originally announced November 2024.
-
Squeezing the quantum noise of a gravitational-wave detector below the standard quantum limit
Authors:
Wenxuan Jia,
Victoria Xu,
Kevin Kuns,
Masayuki Nakano,
Lisa Barsotti,
Matthew Evans,
Nergis Mavalvala,
Rich Abbott,
Ibrahim Abouelfettouh,
Rana Adhikari,
Alena Ananyeva,
Stephen Appert,
Koji Arai,
Naoki Aritomi,
Stuart Aston,
Matthew Ball,
Stefan Ballmer,
David Barker,
Beverly Berger,
Joseph Betzwieser,
Dripta Bhattacharjee,
Garilynn Billingsley,
Nina Bode,
Edgard Bonilla,
Vladimir Bossilkov
, et al. (146 additional authors not shown)
Abstract:
Precision measurements of space and time, like those made by the detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO), are often confronted with fundamental limitations imposed by quantum mechanics. The Heisenberg uncertainty principle dictates that the position and momentum of an object cannot both be precisely measured, giving rise to an apparent limitation called the Stan…
▽ More
Precision measurements of space and time, like those made by the detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO), are often confronted with fundamental limitations imposed by quantum mechanics. The Heisenberg uncertainty principle dictates that the position and momentum of an object cannot both be precisely measured, giving rise to an apparent limitation called the Standard Quantum Limit (SQL). Reducing quantum noise below the SQL in gravitational-wave detectors, where photons are used to continuously measure the positions of freely falling mirrors, has been an active area of research for decades. Here we show how the LIGO A+ upgrade reduced the detectors' quantum noise below the SQL by up to 3 dB while achieving a broadband sensitivity improvement, more than two decades after this possibility was first presented.
△ Less
Submitted 16 October, 2024; v1 submitted 22 April, 2024;
originally announced April 2024.
-
Limits and prospects for long-baseline optical fiber interferometry
Authors:
Christopher Hilweg,
Danial Shadmany,
Philip Walther,
Nergis Mavalvala,
Vivishek Sudhir
Abstract:
Today's most precise optical instruments -- gravitational-wave interferometers and optical atomic clocks -- rely on long storage times for photons to realize their exquisite sensitivity. Optical fiber technology is the most widely deployed platform for realizing long-distance optical propagation. Yet, their application to precision optical measurements is sparse. We review the state-of-the-art in…
▽ More
Today's most precise optical instruments -- gravitational-wave interferometers and optical atomic clocks -- rely on long storage times for photons to realize their exquisite sensitivity. Optical fiber technology is the most widely deployed platform for realizing long-distance optical propagation. Yet, their application to precision optical measurements is sparse. We review the state-of-the-art in the noise performance of conventional (solid-core) optical fibers from the perspective of precision optical measurements and quantum technology that rely on precise transfer of information over long distances. In doing so, we highlight the limitations of this platform and point to the opportunities that structured fiber technology offers to overcome some of these limitations.
△ Less
Submitted 19 March, 2024; v1 submitted 19 August, 2022;
originally announced August 2022.
-
Point Absorber Limits to Future Gravitational-Wave Detectors
Authors:
W. Jia,
H. Yamamoto,
K. Kuns,
A. Effler,
M. Evans,
P. Fritschel,
R. Abbott,
C. Adams,
R. X. Adhikari,
A. Ananyeva,
S. Appert,
K. Arai,
J. S. Areeda,
Y. Asali,
S. M. Aston,
C. Austin,
A. M. Baer,
M. Ball,
S. W. Ballmer,
S. Banagiri,
D. Barker,
L. Barsotti,
J. Bartlett,
B. K. Berger,
J. Betzwieser
, et al. (176 additional authors not shown)
Abstract:
High-quality optical resonant cavities require low optical loss, typically on the scale of parts per million. However, unintended micron-scale contaminants on the resonator mirrors that absorb the light circulating in the cavity can deform the surface thermoelastically, and thus increase losses by scattering light out of the resonant mode. The point absorber effect is a limiting factor in some hig…
▽ More
High-quality optical resonant cavities require low optical loss, typically on the scale of parts per million. However, unintended micron-scale contaminants on the resonator mirrors that absorb the light circulating in the cavity can deform the surface thermoelastically, and thus increase losses by scattering light out of the resonant mode. The point absorber effect is a limiting factor in some high-power cavity experiments, for example, the Advanced LIGO gravitational wave detector. In this Letter, we present a general approach to the point absorber effect from first principles and simulate its contribution to the increased scattering. The achievable circulating power in current and future gravitational-wave detectors is calculated statistically given different point absorber configurations. Our formulation is further confirmed experimentally in comparison with the scattered power in the arm cavity of Advanced LIGO measured by in-situ photodiodes. The understanding presented here provides an important tool in the global effort to design future gravitational wave detectors that support high optical power, and thus reduce quantum noise.
△ Less
Submitted 17 September, 2021;
originally announced September 2021.
-
LIGOs Quantum Response to Squeezed States
Authors:
L. McCuller,
S. E. Dwyer,
A. C. Green,
Haocun Yu,
L. Barsotti,
C. D. Blair,
D. D. Brown,
A. Effler,
M. Evans,
A. Fernandez-Galiana,
P. Fritschel,
V. V. Frolov,
N. Kijbunchoo,
G. L. Mansell,
F. Matichard,
N. Mavalvala,
D. E. McClelland,
T. McRae,
A. Mullavey,
D. Sigg,
B. J. J. Slagmolen,
M. Tse,
T. Vo,
R. L. Ward,
C. Whittle
, et al. (172 additional authors not shown)
Abstract:
Gravitational Wave interferometers achieve their profound sensitivity by combining a Michelson interferometer with optical cavities, suspended masses, and now, squeezed quantum states of light. These states modify the measurement process of the LIGO, VIRGO and GEO600 interferometers to reduce the quantum noise that masks astrophysical signals; thus, improvements to squeezing are essential to furth…
▽ More
Gravitational Wave interferometers achieve their profound sensitivity by combining a Michelson interferometer with optical cavities, suspended masses, and now, squeezed quantum states of light. These states modify the measurement process of the LIGO, VIRGO and GEO600 interferometers to reduce the quantum noise that masks astrophysical signals; thus, improvements to squeezing are essential to further expand our gravitational view of the universe. Further reducing quantum noise will require both lowering decoherence from losses as well more sophisticated manipulations to counter the quantum back-action from radiation pressure. Both tasks require fully understanding the physical interactions between squeezed light and the many components of km-scale interferometers. To this end, data from both LIGO observatories in observing run three are expressed using frequency-dependent metrics to analyze each detector's quantum response to squeezed states. The response metrics are derived and used to concisely describe physical mechanisms behind squeezing's simultaneous interaction with transverse-mode selective optical cavities and the quantum radiation pressure noise of suspended mirrors. These metrics and related analysis are broadly applicable for cavity-enhanced optomechanics experiments that incorporate external squeezing, and -- for the first time -- give physical descriptions of every feature so far observed in the quantum noise of the LIGO detectors.
△ Less
Submitted 25 May, 2021;
originally announced May 2021.
-
Point absorbers in Advanced LIGO
Authors:
Aidan F. Brooks,
Gabriele Vajente,
Hiro Yamamoto,
Rich Abbott,
Carl Adams,
Rana X. Adhikari,
Alena Ananyeva,
Stephen Appert,
Koji Arai,
Joseph S. Areeda,
Yasmeen Asali,
Stuart M. Aston,
Corey Austin,
Anne M. Baer,
Matthew Ball,
Stefan W. Ballmer,
Sharan Banagiri,
David Barker,
Lisa Barsotti,
Jeffrey Bartlett,
Beverly K. Berger,
Joseph Betzwieser,
Dripta Bhattacharjee,
Garilynn Billingsley,
Sebastien Biscans
, et al. (176 additional authors not shown)
Abstract:
Small, highly absorbing points are randomly present on the surfaces of the main interferometer optics in Advanced LIGO. The resulting nano-meter scale thermo-elastic deformations and substrate lenses from these micron-scale absorbers significantly reduces the sensitivity of the interferometer directly though a reduction in the power-recycling gain and indirect interactions with the feedback contro…
▽ More
Small, highly absorbing points are randomly present on the surfaces of the main interferometer optics in Advanced LIGO. The resulting nano-meter scale thermo-elastic deformations and substrate lenses from these micron-scale absorbers significantly reduces the sensitivity of the interferometer directly though a reduction in the power-recycling gain and indirect interactions with the feedback control system. We review the expected surface deformation from point absorbers and provide a pedagogical description of the impact on power build-up in second generation gravitational wave detectors (dual-recycled Fabry-Perot Michelson interferometers). This analysis predicts that the power-dependent reduction in interferometer performance will significantly degrade maximum stored power by up to 50% and hence, limit GW sensitivity, but suggests system wide corrections that can be implemented in current and future GW detectors. This is particularly pressing given that future GW detectors call for an order of magnitude more stored power than currently used in Advanced LIGO in Observing Run 3. We briefly review strategies to mitigate the effects of point absorbers in current and future GW wave detectors to maximize the success of these enterprises.
△ Less
Submitted 25 March, 2021; v1 submitted 14 January, 2021;
originally announced January 2021.
-
A Novel Modulation Scheme for Homodyne Detection Control
Authors:
Danial Shadmany,
Benjamin Lane,
Vivishek Sudhir,
Nergis Mavalvala
Abstract:
Controlling the quadrature measured by a homodyne detector is a universal task in continuous-variable quantum optics. However, deriving an error signal that is linear across theentire range of quadrature angles remains an open experimental problem. Here we propose a scheme to produce such an error signal through the use of a universally tunable modulator.
Controlling the quadrature measured by a homodyne detector is a universal task in continuous-variable quantum optics. However, deriving an error signal that is linear across theentire range of quadrature angles remains an open experimental problem. Here we propose a scheme to produce such an error signal through the use of a universally tunable modulator.
△ Less
Submitted 11 February, 2021; v1 submitted 5 January, 2021;
originally announced January 2021.
-
Demonstration of an amplitude filter cavity at gravitational-wave frequencies
Authors:
Kentaro Komori,
Dhruva Ganapathy,
Chris Whittle,
Lee McCuller,
Lisa Barsotti,
Nergis Mavalvala,
Matthew Evans
Abstract:
Quantum vacuum fluctuations fundamentally limit the precision of optical measurements, such as those in gravitational-wave detectors. Injection of conventional squeezed vacuum can be used to reduce quantum noise in the readout quadrature, but this reduction is at the cost of increasing noise in the orthogonal quadrature. For detectors near the limits imposed by quantum radiation pressure noise (QR…
▽ More
Quantum vacuum fluctuations fundamentally limit the precision of optical measurements, such as those in gravitational-wave detectors. Injection of conventional squeezed vacuum can be used to reduce quantum noise in the readout quadrature, but this reduction is at the cost of increasing noise in the orthogonal quadrature. For detectors near the limits imposed by quantum radiation pressure noise (QRPN), both quadratures impact the measurement, and the benefits of conventional squeezing are limited. In this paper, we demonstrate the use of a critically-coupled 16m optical cavity to diminish anti-squeezing at frequencies below 90Hz where it exacerbates QRPN, while preserving beneficial squeezing at higher frequencies. This is called an amplitude filter cavity, and it is useful for avoiding degradation of detector sensitivity at low frequencies. The attenuation from the cavity also provides technical advantages such as mitigating backscatter.
△ Less
Submitted 12 November, 2020; v1 submitted 18 August, 2020;
originally announced August 2020.
-
Optimal detuning for quantum filter cavities
Authors:
Chris Whittle,
Kentaro Komori,
Dhruva Ganapathy,
Lee McCuller,
Lisa Barsotti,
Nergis Mavalvala,
Matthew Evans
Abstract:
Vacuum quantum fluctuations impose a fundamental limit on the sensitivity of gravitational-wave interferometers, which rank among the most sensitive precision measurement devices ever built. The injection of conventional squeezed vacuum reduces quantum noise in one quadrature at the expense of increasing noise in the other. While this approach improved the sensitivity of the Advanced LIGO and Adva…
▽ More
Vacuum quantum fluctuations impose a fundamental limit on the sensitivity of gravitational-wave interferometers, which rank among the most sensitive precision measurement devices ever built. The injection of conventional squeezed vacuum reduces quantum noise in one quadrature at the expense of increasing noise in the other. While this approach improved the sensitivity of the Advanced LIGO and Advanced Virgo interferometers during their third observing run (O3), future improvements in arm power and squeezing levels will bring radiation pressure noise to the forefront. Installation of a filter cavity for frequency-dependent squeezing provides broadband reduction of quantum noise through the mitigation of this radiation pressure noise, and it is the baseline approach planned for all of the future gravitational-wave detectors currently conceived. The design and operation of a filter cavity requires careful consideration of interferometer optomechanics as well as squeezing degradation processes. In this paper, we perform an in-depth analysis to determine the optimal operating point of a filter cavity. We use our model alongside numerical tools to study the implications for filter cavities to be installed in the upcoming "A+" upgrade of the Advanced LIGO detectors.
△ Less
Submitted 12 November, 2020; v1 submitted 18 August, 2020;
originally announced August 2020.
-
Frequency-Dependent Squeezing for Advanced LIGO
Authors:
L. McCuller,
C. Whittle,
D. Ganapathy,
K. Komori,
M. Tse,
A. Fernandez-Galiana,
L. Barsotti,
P. Fritschel,
M. MacInnis,
F. Matichard,
K. Mason,
N. Mavalvala,
R. Mittleman,
Haocun Yu,
M. E. Zucker,
M. Evans
Abstract:
The first detection of gravitational waves by the Laser Interferometer Gravitational-wave Observatory (LIGO) in 2015 launched the era of gravitational wave astronomy. The quest for gravitational wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of li…
▽ More
The first detection of gravitational waves by the Laser Interferometer Gravitational-wave Observatory (LIGO) in 2015 launched the era of gravitational wave astronomy. The quest for gravitational wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light is being used to improve the shot noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above $\sim 50$ Hz. Below this frequency, quantum back action, in the form of radiation pressure induced motion of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30Hz, using a 16m long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as "A+."
△ Less
Submitted 26 March, 2020;
originally announced March 2020.
-
A compact actively damped vibration isolation platform for optical experiments in ultra-high vacuum
Authors:
Álvaro Fernández-Galiana,
Lee McCuller,
Jeff Kissel,
Lisa Barsotti,
John Miller,
Maggie Tse,
Matthew Evans,
Stuart M. Aston,
Thomas J. Shaffer,
Arnaud Pele,
Janeen H. Romie,
Betsy Weaver,
Richard Abbott,
Peter Fritschel,
Nergis Mavalvala,
Fabrice Matichard
Abstract:
We present a tabletop six-axis vibration isolation system, compatible with Ultra-High Vacuum (UHV), which is actively damped and provides 25 dB of isolation at 10 Hz and 65 dB at 100 Hz. While this isolation platform has been primarily designed to support optics in the Laser Interferometer Gravitational-Wave Observatory (LIGO) detectors, it is suitable for a variety of applications. The system has…
▽ More
We present a tabletop six-axis vibration isolation system, compatible with Ultra-High Vacuum (UHV), which is actively damped and provides 25 dB of isolation at 10 Hz and 65 dB at 100 Hz. While this isolation platform has been primarily designed to support optics in the Laser Interferometer Gravitational-Wave Observatory (LIGO) detectors, it is suitable for a variety of applications. The system has been engineered to facilitate the construction and assembly process, while minimizing cost. The platform provides passive isolation for six degrees of freedom using a combination of vertical springs and horizontal pendula. It is instrumented with voice-coil actuators and optical shadow sensors to damp the resonances. All materials are compatible with stringent vacuum requirements. Thanks to its architecture, the system's footprint can be adapted to meet spatial requirements, while maximizing the dimensions of the optical table. Three units are currently operating for LIGO. We present the design of the system, controls principle, and experimental results.
△ Less
Submitted 24 July, 2019; v1 submitted 24 January, 2019;
originally announced January 2019.
-
Sub-Hertz Optomechanically-Induced Transparency
Authors:
T. Bodiya,
V. Sudhir,
C. Wipf,
N. Smith,
A. Buikema,
A. Kontos,
H. Yu,
N. Mavalvala
Abstract:
Optical interferometers with suspended mirrors are the archetype of all current audio-frequency gravitational-wave detectors. The radiation pressure interaction between the motion of the mirror and the circulating optical field in such interferometers represents a pristine form of light-matter coupling, largely due to 30 years of effort in developing high quality optical materials with low mechani…
▽ More
Optical interferometers with suspended mirrors are the archetype of all current audio-frequency gravitational-wave detectors. The radiation pressure interaction between the motion of the mirror and the circulating optical field in such interferometers represents a pristine form of light-matter coupling, largely due to 30 years of effort in developing high quality optical materials with low mechanical dissipation. However, in all current suspended interferometers, the radiation pressure interaction is too weak to be useful as a resource, and too strong to be neglected. Here, we demonstrate a meter-long interferometer with suspended mirrors, of effective mass $~ 125$ g, where the radiation pressure interaction is enhanced by strong optical pumping to realize a cooperativity of $50$. We probe this regime by observing optomechanically-induced transparency of a weak on-resonant probe. The low resonant frequency and high-Q of the mechanical oscillator allows us to demonstrate transparency windows barely $100$ mHz wide at room temperature. Together with a near-unity ($\sim 99.9\%$) out-coupling efficiency, our system saturates the theoretical delay-bandwidth product, rendering it an optical buffer capable of seconds-long storage times.
△ Less
Submitted 25 December, 2018;
originally announced December 2018.
-
Room temperature optomechanical squeezing
Authors:
Nancy Aggarwal,
Torrey Cullen,
Jonathan Cripe,
Garrett D. Cole,
Robert Lanza,
Adam Libson,
David Follman,
Paula Heu,
Thomas Corbitt,
Nergis Mavalvala
Abstract:
The radiation-pressure driven interaction of a coherent light field with a mechanical oscillator induces correlations between the amplitude and phase quadratures of the light. These correlations result in squeezed light -- light with quantum noise lower than shot noise in some quadratures, and higher in others. Due to this lower quantum uncertainty, squeezed light can be used to improve the sensit…
▽ More
The radiation-pressure driven interaction of a coherent light field with a mechanical oscillator induces correlations between the amplitude and phase quadratures of the light. These correlations result in squeezed light -- light with quantum noise lower than shot noise in some quadratures, and higher in others. Due to this lower quantum uncertainty, squeezed light can be used to improve the sensitivity of precision measurements. In particular, squeezed light sources based on nonlinear optical crystals are being used to improve the sensitivity of gravitational wave (GW) detectors. For optomechanical squeezers, thermally driven fluctuations of the mechanical oscillator's position makes it difficult to observe the quantum correlations at room temperature, and at low frequencies. Here we present a measurement of optomechanically (OM) squeezed light, performed at room-temperature, in a broad band near audio-frequency regions relevant to GW detectors. We observe sub-poissonian quantum noise in a frequency band of 30 kHz to 70 kHz with a maximum reduction of 0.7 $\pm$ 0.1 dB below shot noise at 45 kHz. We present two independent methods of measuring this squeezing, one of which does not rely on calibration of shot noise.
△ Less
Submitted 24 December, 2018;
originally announced December 2018.
-
Relativistic coupling of phase and amplitude noise in optical interferometry
Authors:
Vivishek Sudhir,
Peter Fritschel,
Nergis Mavalvala
Abstract:
Extraneous motion of optical elements in an interferometer lead to excess noise. Typically, fluctuations in the effective path length lead to phase noise, while beam-pointing leads to apparent amplitude noise. For a transmissive optic moving along the optical axis, neither effect should exist. However, relativity of motion suggests that even in this case, small corrections of order $v/c$ ($v$ the…
▽ More
Extraneous motion of optical elements in an interferometer lead to excess noise. Typically, fluctuations in the effective path length lead to phase noise, while beam-pointing leads to apparent amplitude noise. For a transmissive optic moving along the optical axis, neither effect should exist. However, relativity of motion suggests that even in this case, small corrections of order $v/c$ ($v$ the velocity of the optic), give rise to phase and amplitude noise on the light. Here we calculate the effect of this relativistic mechanism of noise coupling, and discuss when such an effect would limit the sensitivity of optical interferometers.
△ Less
Submitted 19 June, 2018;
originally announced June 2018.
-
Radiation-Pressure-Mediated Control of an Optomechanical Cavity
Authors:
Jonathan Cripe,
Nancy Aggarwal,
Robinjeet Singh,
Robert Lanza,
Adam Libson,
Min Jet Yap,
Garrett D. Cole,
David E. McClelland,
Nergis Mavalvala,
Thomas Corbitt
Abstract:
We describe and demonstrate a method to control a detuned movable-mirror Fabry-Perot cavity using radiation pressure in the presence of a strong optical spring. At frequencies below the optical spring resonance, self-locking of the cavity is achieved intrinsically by the optomechanical (OM) interaction between the cavity field and the movable end mirror. The OM interaction results in a high rigidi…
▽ More
We describe and demonstrate a method to control a detuned movable-mirror Fabry-Perot cavity using radiation pressure in the presence of a strong optical spring. At frequencies below the optical spring resonance, self-locking of the cavity is achieved intrinsically by the optomechanical (OM) interaction between the cavity field and the movable end mirror. The OM interaction results in a high rigidity and reduced susceptibility of the mirror to external forces. However, due to a finite delay time in the cavity, this enhanced rigidity is accompanied by an anti-damping force, which destabilizes the cavity. The cavity is stabilized by applying external feedback in a frequency band around the optical spring resonance. The error signal is sensed in the amplitude quadrature of the transmitted beam with a photodetector. An amplitude modulator in the input path to the cavity modulates the light intensity to provide the stabilizing radiation pressure force.
△ Less
Submitted 4 December, 2017; v1 submitted 12 October, 2017;
originally announced October 2017.
-
Quantum correlation measurements in interferometric gravitational wave detectors
Authors:
D. V. Martynov,
V. V. Frolov,
S. Kandhasamy,
K. Izumi,
H. Miao,
N. Mavalvala,
E. D. Hall,
R. Lanza,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
C. Adams,
R. X. Adhikari,
S. B. Anderson,
A. Ananyeva,
S. Appert,
K. Arai,
S. M. Aston,
S. W. Ballmer,
D. Barker,
B. Barr,
L. Barsotti,
J. Bartlett,
I. Bartos,
J. C. Batch
, et al. (177 additional authors not shown)
Abstract:
Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational wave detectors, such as the Advanced Laser Interferometer Gravitational wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the…
▽ More
Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational wave detectors, such as the Advanced Laser Interferometer Gravitational wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the quantum properties of light can be used to distinguish these noises using correlation techniques. Particularly, in the first part of the paper we show estimations of the coating thermal noise and gas phase noise, hidden below the quantum shot noise in the Advanced LIGO sensitivity curve. We also make projections on the observatory sensitivity during the next science runs. In the second part of the paper we discuss the correlation technique that reveals the quantum radiation pressure noise from the background of classical noises and shot noise. We apply this technique to the Advanced LIGO data, collected during the first science run, and experimentally estimate the quantum correlations and quantum radiation pressure noise in the interferometer for the first time.
△ Less
Submitted 10 February, 2017;
originally announced February 2017.
-
The Sensitivity of the Advanced LIGO Detectors at the Beginning of Gravitational Wave Astronomy
Authors:
D. V. Martynov,
E. D. Hall,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
C. Adams,
R. X. Adhikari,
R. A. Anderson,
S. B. Anderson,
K. Arai,
M. A. Arain,
S. M. Aston,
L. Austin,
S. W. Ballmer,
M. Barbet,
D. Barker,
B. Barr,
L. Barsotti,
J. Bartlett,
M. A. Barton,
I. Bartos,
J. C. Batch,
A. S. Bell,
I. Belopolski,
J. Bergman
, et al. (239 additional authors not shown)
Abstract:
The Laser Interferometer Gravitational Wave Observatory (LIGO) consists of two widely separated 4 km laser interferometers designed to detect gravitational waves from distant astrophysical sources in the frequency range from 10 Hz to 10 kHz. The first observation run of the Advanced LIGO detectors started in September 2015 and ended in January 2016. A strain sensitivity of better than…
▽ More
The Laser Interferometer Gravitational Wave Observatory (LIGO) consists of two widely separated 4 km laser interferometers designed to detect gravitational waves from distant astrophysical sources in the frequency range from 10 Hz to 10 kHz. The first observation run of the Advanced LIGO detectors started in September 2015 and ended in January 2016. A strain sensitivity of better than $10^{-23}/\sqrt{\text{Hz}}$ was achieved around 100 Hz. Understanding both the fundamental and the technical noise sources was critical for increasing the observable volume in the universe. The average distance at which coalescing binary black hole systems with individual masses of 30 $M_\odot$ could be detected was 1.3 Gpc. Similarly, the range for binary neutron star inspirals was about 75 Mpc. With respect to the initial detectors, the observable volume of Universe increased respectively by a factor 69 and 43. These improvements allowed Advanced LIGO to detect the gravitational wave signal from the binary black hole coalescence, known as GW150914.
△ Less
Submitted 10 February, 2018; v1 submitted 1 April, 2016;
originally announced April 2016.
-
Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
Authors:
The LIGO Scientific Collaboration,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
M. R. Abernathy,
K. Ackley,
C. Adams,
P. Addesso,
R. X. Adhikari,
V. B. Adya,
C. Affeldt,
N. Aggarwal,
O. D. Aguiar,
A. Ain,
P. Ajith,
B. Allen,
P. A. Altin,
D. V. Amariutei,
S. B. Anderson,
W. G. Anderson,
K. Arai,
M. C. Araya,
C. C. Arceneaux,
J. S. Areeda,
K. G. Arun
, et al. (702 additional authors not shown)
Abstract:
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detec…
▽ More
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz.
△ Less
Submitted 28 February, 2017; v1 submitted 11 February, 2016;
originally announced February 2016.
-
Audio-band frequency-dependent squeezing
Authors:
Eric Oelker,
Tomoki Isogai,
John Miller,
Maggie Tse,
Lisa Barsotti,
Nergis Mavalvala,
Matthew Evans
Abstract:
Quantum vacuum fluctuations impose strict limits on precision displacement measurements, those of interferometric gravitational-wave detectors among them. Introducing squeezed states into an interferometer's readout port can improve the sensitivity of the instrument, leading to richer astrophysical observations. However, optomechanical interactions dictate that the vacuum's squeezed quadrature mus…
▽ More
Quantum vacuum fluctuations impose strict limits on precision displacement measurements, those of interferometric gravitational-wave detectors among them. Introducing squeezed states into an interferometer's readout port can improve the sensitivity of the instrument, leading to richer astrophysical observations. However, optomechanical interactions dictate that the vacuum's squeezed quadrature must rotate by 90 degrees around 50Hz. Here we use a 2-m-long, high-finesse optical resonator to produce frequency-dependent rotation around 1.2kHz. This demonstration of audio-band frequency-dependent squeezing uses technology and methods that are scalable to the required rotation frequency, heralding application of the technique in future gravitational-wave detectors.
△ Less
Submitted 18 August, 2015;
originally announced August 2015.
-
A continuously tunable modulation scheme for precision control of optical cavities with variable detuning
Authors:
William Yam,
Emily Davis,
Sarah Ackley,
Matthew Evans,
Nergis Mavalvala
Abstract:
We present a scheme for locking optical cavities with arbitrary detuning many line widths from resonance using an electro-optic modulator that can provide arbitrary ratios of amplitude to phase modulation. We demonstrate our scheme on a Fabry-Perot cavity, and show that a well-behaved linear error signal can be obtained by demodulating the reflected light from a cavity that is detuned by several l…
▽ More
We present a scheme for locking optical cavities with arbitrary detuning many line widths from resonance using an electro-optic modulator that can provide arbitrary ratios of amplitude to phase modulation. We demonstrate our scheme on a Fabry-Perot cavity, and show that a well-behaved linear error signal can be obtained by demodulating the reflected light from a cavity that is detuned by several line widths.
△ Less
Submitted 20 May, 2015;
originally announced May 2015.
-
Impact of backscattered light in a squeezing-enhanced interferometric gravitational-wave detector
Authors:
S. S. Y. Chua,
S. Dwyer,
L. Barsotti,
D. Sigg,
R. M. S. Schofield,
V. V. Frolov,
K. Kawabe,
M. Evans,
G. D. Meadors,
M. Factourovich,
R. Gustafson,
N. Smith-Lefebvre,
C. Vorvick,
M. Landry,
A. Khalaidovski,
M. S. Stefszky,
C. M. Mow-Lowry,
B. C. Buchler,
D. A. Shaddock,
P. K. Lam,
R. Schnabel,
N. Mavalvala,
D. E. McClelland
Abstract:
Squeezed states of light have been recently used to improve the sensitivity of laser interferometric gravitational-wave detectors beyond the quantum limit. To completely establish quantum engineering as a realistic option for the next generation of detectors, it is crucial to study and quantify the noise coupling mechanisms which injection of squeezed states could potentially introduce. We present…
▽ More
Squeezed states of light have been recently used to improve the sensitivity of laser interferometric gravitational-wave detectors beyond the quantum limit. To completely establish quantum engineering as a realistic option for the next generation of detectors, it is crucial to study and quantify the noise coupling mechanisms which injection of squeezed states could potentially introduce. We present a direct measurement of the impact of backscattered light from a squeezed-light source deployed on one of the 4 km long detectors of the Laser Interferometric Gravitational Wave Observatory (LIGO). We also show how our measurements inform the design of squeezed light sources compatible with the even more sensitive advanced detectors currently under construction, such as Advanced LIGO.
△ Less
Submitted 7 November, 2013; v1 submitted 30 July, 2013;
originally announced July 2013.
-
Optimal Alignment Sensing of a Readout Mode Cleaner Cavity
Authors:
Nicolas Smith-Lefebvre,
Stefan Ballmer,
Matt Evans,
Sam Waldman,
Keita Kawabe,
Valery Frolov,
Nergis Mavalvala
Abstract:
Critically coupled resonant optical cavities are often used as mode cleaners in optical systems to improve the signal to noise ratio (SNR) of a signal that is encoded as an amplitude modulation of a laser beam. Achieving the best SNR requires maintaining the alignment of the mode cleaner relative to the laser beam on which the signal is encoded. An automatic alignment system which is primarily sen…
▽ More
Critically coupled resonant optical cavities are often used as mode cleaners in optical systems to improve the signal to noise ratio (SNR) of a signal that is encoded as an amplitude modulation of a laser beam. Achieving the best SNR requires maintaining the alignment of the mode cleaner relative to the laser beam on which the signal is encoded. An automatic alignment system which is primarily sensitive to the carrier field component of the beam will not, in general, provide optimal SNR. We present an approach that modifies traditional dither alignment sensing by applying a large amplitude modulation on the signal field, thereby producing error signals that are sensitive to the signal sideband field alignment. When used in conjunction with alignment actuators, this approach can improve the detected SNR; we demonstrate a factor of 3 improvement in the SNR of a kilometer-scale detector of the Laser Interferometer Gravitational-wave Observatory. This approach can be generalized to other types of alignment sensors.
△ Less
Submitted 18 October, 2011;
originally announced October 2011.
-
Readout and Control of a Power-recycled Interferometric Gravitational-wave Antenna
Authors:
D. Sigg,
H. Rong,
P. Fritschel,
M. Zucker,
R. Bork,
N. Mavalvala,
D. Ouimette,
G. Gonzalez
Abstract:
Interferometric gravitational wave antennas are based on Michelson interferometers whose sensitivity to small differential length changes has been enhanced by adding multiple coupled optical resonators. The use of optical cavities is essential for reaching the required sensitivity, but sets challenges for the control system which must maintain the cavities near resonance. The goal for the strain…
▽ More
Interferometric gravitational wave antennas are based on Michelson interferometers whose sensitivity to small differential length changes has been enhanced by adding multiple coupled optical resonators. The use of optical cavities is essential for reaching the required sensitivity, but sets challenges for the control system which must maintain the cavities near resonance. The goal for the strain sensitivity of the Laser Interferometer Gravitational-wave Observatory (LIGO) is 10^-21 rms, integrated over a 100 Hz bandwidth centered at 150 Hz. We present the major design features of the LIGO length and frequency sensing and control system which will hold the differential length to within 5 10^-14 m of the operating point. We also highlight the restrictions imposed by couplings of noise into the gravitational wave readout signal and the required immunity against them.
△ Less
Submitted 8 November, 2001;
originally announced November 2001.