-
Stable beam operation of approximately 1 mA beam under highly efficient energy recovery conditions at compact energy-recovery linac
Authors:
Hiroshi Sakai,
Dai Arakawa,
Takaaki Furuya,
Kaiichi Haga,
Masayuki Hagiwara,
Kentaro Harada,
Yosuke Honda,
Teruya Honma,
Eiji Kako,
Ryukou Kato,
Yuuji Kojima,
Taro Konomi,
Hiroshi Matsumura,
Taichi Miura,
Takako Miura,
Shinya Nagahashi,
Hirotaka Nakai,
Norio Nakamura,
Kota Nakanishi,
Kazuyuki Nigorikawa,
Takashi Nogami,
Takashi Obina,
Feng Qiu,
Hidenori Sagehashi,
Shogo Sakanaka
, et al. (15 additional authors not shown)
Abstract:
A compact energy-recovery linac (cERL) has been un-der construction at KEK since 2009 to develop key technologies for the energy-recovery linac. The cERL began operating in 2013 to create a high-current beam with a low-emittance beam with stable continuous wave (CW) superconducting cavities. Owing to the development of critical components, such as the DC gun, superconducting cavities, and the desi…
▽ More
A compact energy-recovery linac (cERL) has been un-der construction at KEK since 2009 to develop key technologies for the energy-recovery linac. The cERL began operating in 2013 to create a high-current beam with a low-emittance beam with stable continuous wave (CW) superconducting cavities. Owing to the development of critical components, such as the DC gun, superconducting cavities, and the design of ideal beam transport optics, we have successfully established approximately 1 mA stable CW operation with a small beam emittance and extremely small beam loss. This study presents the details of our key technologies and experimental results for achieving 100% energy recovery operation with extremely small beam loss during a stable, approximately 1 mA CW beam operation.
△ Less
Submitted 24 August, 2024;
originally announced August 2024.
-
Evaluation of Kyoto's Event-Driven X-ray Astronomical SOI Pixel Sensor with a Large Imaging Area
Authors:
Hideki Hayashi,
Takeshi Go Tsuru,
Takaaki Tanaka,
Hiroyuki Uchida,
Hideaki Matsumura,
Katsuhiro Tachibana,
Sodai Harada,
Ayaki Takeda,
Koji Mori,
Yusuke Nishioka,
Nobuaki Takebayashi,
Shoma Yokoyama,
Kohei Fukuda,
Yasuo Arai,
Ikuo Kurachi,
Shoji Kawahito,
Keiichiro Kagawa,
Keita Yasutomi,
Sumeet Shrestha,
Syunta Nakanishi,
Hiroki Kamehama,
Takayoshi Kohmura,
Kouichi Hagino,
Kousuke Negishi,
Kenji Oono
, et al. (1 additional authors not shown)
Abstract:
We have been developing monolithic active pixel sensors, named ``XRPIX'', based on the silicon-on-insulator (SOI) pixel technology for future X-ray astronomy satellites. XRPIX has the function of event trigger and hit address outputs. This function allows us to read out analog signals only of hit pixels on trigger timing, which is referred to as the event-driven readout mode. Recently, we processe…
▽ More
We have been developing monolithic active pixel sensors, named ``XRPIX'', based on the silicon-on-insulator (SOI) pixel technology for future X-ray astronomy satellites. XRPIX has the function of event trigger and hit address outputs. This function allows us to read out analog signals only of hit pixels on trigger timing, which is referred to as the event-driven readout mode. Recently, we processed ``XRPIX5b'' with the largest imaging area of 21.9~mm $\times$ 13.8~mm in the XRPIX series. X-ray spectra are successfully obtained from all the pixels, and the readout noise is 46~e$^-$~(rms) in the frame readout mode. The gain variation was measured to be 1.2\%~(FWHM) among the pixels. We successfully obtain the X-ray image in the event-driven readout mode.
△ Less
Submitted 29 April, 2019;
originally announced April 2019.
-
Performance of SOI Pixel Sensors Developed for X-ray Astronomy
Authors:
Takaaki Tanaka,
Takeshi Go Tsuru,
Hiroyuki Uchida,
Sodai Harada,
Tomoyuki Okuno,
Kazuho Kayama,
Yuki Amano,
Hideaki Matsumura,
Ayaki Takeda,
Koji Mori,
Yusuke Nishioka,
Kohei Fukuda,
Takahiro Hida,
Masataka Yukumoto,
Yasuo Arai,
Ikuo Kurachi,
Shoji Kawahito,
Keiichiro Kagawa,
Keita Yasutomi,
Sumeet Shrestha,
Syunta Nakanishi,
Hiroki Kamehama,
Takayoshi Kohmura,
Kouichi Hagino,
Kousuke Negishi
, et al. (2 additional authors not shown)
Abstract:
We have been developing monolithic active pixel sensors for X-rays based on the silicon-on-insulator technology. Our device consists of a low-resistivity Si layer for readout CMOS electronics, a high-resistivity Si sensor layer, and a SiO$_2$ layer between them. This configuration allows us both high-speed readout circuits and a thick (on the order of $100~μ{\rm m}$) depletion layer in a monolithi…
▽ More
We have been developing monolithic active pixel sensors for X-rays based on the silicon-on-insulator technology. Our device consists of a low-resistivity Si layer for readout CMOS electronics, a high-resistivity Si sensor layer, and a SiO$_2$ layer between them. This configuration allows us both high-speed readout circuits and a thick (on the order of $100~μ{\rm m}$) depletion layer in a monolithic device. Each pixel circuit contains a trigger output function, with which we can achieve a time resolution of $\lesssim 10~μ{\rm s}$. One of our key development items is improvement of the energy resolution. We recently fabricated a device named XRPIX6E, to which we introduced a pinned depleted diode (PDD) structure. The structure reduces the capacitance coupling between the sensing area in the sensor layer and the pixel circuit, which degrades the spectral performance. With XRPIX6E, we achieve an energy resolution of $\sim 150$~eV in full width at half maximum for 6.4-keV X-rays. In addition to the good energy resolution, a large imaging area is required for practical use. We developed and tested XRPIX5b, which has an imaging area size of $21.9~{\rm mm} \times 13.8~{\rm mm}$ and is the largest device that we ever fabricated. We successfully obtain X-ray data from almost all the $608 \times 384$ pixels with high uniformity.
△ Less
Submitted 14 December, 2018;
originally announced December 2018.
-
X-ray response evaluation in subpixel level for X-ray SOI pixel detectors
Authors:
Kousuke Negishi,
Takayoshi Kohmura,
Kouichi Hagino,
Taku Kogiso,
Kenji Oono,
Keigo Yarita,
Akinori Sasaki,
Koki Tamasawa,
Takeshi G. Tsuru,
Takaaki Tanaka,
Hideaki Matsumura,
Katsuhiro Tachibana,
Hideki Hayashi,
Sodai Harada,
Koji Mori,
Ayaki Takeda,
Yusuke Nishioka,
Nobuaki Takebayashi,
Shoma Yokoyama,
Kohei Fukuda,
Yasuo Arai,
Toshinobu Miyoshi,
Shunji Kishimoto,
Ikuo Kurachi
Abstract:
We have been developing event-driven SOI Pixel Detectors, named `XRPIX' (X-Ray soiPIXel) based on the silicon-on-insulator (SOI) pixel technology, for the future X-ray astronomical satellite with wide band coverage from 0.5 keV to 40 keV. XRPIX has event trigger output function at each pixel to acquire a good time resolution of a few $μ\rm s$ and has Correlated Double Sampling function to reduce e…
▽ More
We have been developing event-driven SOI Pixel Detectors, named `XRPIX' (X-Ray soiPIXel) based on the silicon-on-insulator (SOI) pixel technology, for the future X-ray astronomical satellite with wide band coverage from 0.5 keV to 40 keV. XRPIX has event trigger output function at each pixel to acquire a good time resolution of a few $μ\rm s$ and has Correlated Double Sampling function to reduce electric noises. The good time resolution enables the XRPIX to reduce Non X-ray Background in the high energy band above 10\,keV drastically by using anti-coincidence technique with active shield counters surrounding XRPIX. In order to increase the soft X-ray sensitivity, it is necessary to make the dead layer on the X-ray incident surface as thin as possible. Since XRPIX1b, which is a device at the initial stage of development, is a front-illuminated (FI) type of XRPIX, low energy X-ray photons are absorbed in the 8 $\rm μ$m thick circuit layer, lowering the sensitivity in the soft X-ray band. Therefore, we developed a back-illuminated (BI) device XRPIX2b, and confirmed high detection efficiency down to 2.6 keV, below which the efficiency is affected by the readout noise. In order to further improve the detection efficiency in the soft X-ray band, we developed a back-illuminated device XRPIX3b with lower readout noise. In this work, we irradiated 2--5 keV X-ray beam collimated to 4 $\rm μm φ$ to the sensor layer side of the XRPIX3b at 6 $\rm μm$ pitch. In this paper, we reported the uniformity of the relative detection efficiency, gain and energy resolution in the subpixel level for the first time. We also confirmed that the variation in the relative detection efficiency at the subpixel level reported by Matsumura et al. has improved.
△ Less
Submitted 25 October, 2018;
originally announced October 2018.
-
Proton Radiation Damage Experiment for X-Ray SOI Pixel Detectors
Authors:
Keigo Yarita,
Takayoshi Kohmura,
Kouichi Hagino,
Taku Kogiso,
Kenji Oono,
Kousuke Negishi,
Koki Tamasawa,
Akinori Sasaki,
Satoshi Yoshiki,
Takeshi Go Tsuru,
Takaaki Tanaka,
Hideaki Matsumura,
Katsuhiro Tachibana,
Hideki Hayashi,
Sodai Harada,
Ayaki Takeda,
Koji Mori,
Yusuke Nishioka,
Nobuaki Takebayashi,
Shoma Yokoyama,
Kohei Fukuda,
Yasuo Arai,
Toshinobu Miyoshi,
Ikuo Kurachi,
Tsuyoshi Hamano
, et al. (1 additional authors not shown)
Abstract:
In low earth orbit, there are many cosmic rays composed primarily of high energy protons. These cosmic rays cause surface and bulk radiation effects, resulting in degradation of detector performance. Quantitative evaluation of radiation hardness is essential in development of X-ray detectors for astronomical satellites. We performed proton irradiation experiments on newly developed X-ray detectors…
▽ More
In low earth orbit, there are many cosmic rays composed primarily of high energy protons. These cosmic rays cause surface and bulk radiation effects, resulting in degradation of detector performance. Quantitative evaluation of radiation hardness is essential in development of X-ray detectors for astronomical satellites. We performed proton irradiation experiments on newly developed X-ray detectors called XRPIX based on silicon-on-insulator technology at HIMAC in National Institute of Radiological Sciences. We irradiated 6 MeV protons with a total dose of 0.5 krad, equivalent to 6 years irradiation in orbit. As a result, the gain increases by 0.2% and the energy resolution degrades by 0.5%. Finally we irradiated protons up to 20 krad and found that detector performance degraded significantly at 5 krad. With 5 krad irradiation corresponding to 60 years in orbit, the gain increases by 0.7% and the energy resolution worsens by 10%. By decomposing into noise components, we found that the increase of the circuit noise is dominant in the degradation of the energy resolution.
△ Less
Submitted 22 October, 2018;
originally announced October 2018.
-
Kyoto's Event-Driven X-ray Astronomy SOI pixel sensor for the FORCE mission
Authors:
Takeshi G. Tsuru,
Hideki Hayashi,
Katsuhiro Tachibana,
Sodai Harada,
Hiroyuki Uchida,
Takaaki Tanaka,
Yasuo Arai,
Ikuo Kurachi,
Koji Mori,
Ayaki Takeda,
Yusuke Nishioka,
Nobuaki Takebayashi,
Shoma Yokoyama,
Kohei Fukuda,
Takayoshi Kohmura,
Kouichi Hagino,
Kenji Ohno,
Kohsuke Negishi,
Keigo Yarita,
Shoji Kawahito,
Keiichiro Kagawa,
Keita Yasutomi,
Sumeet Shrestha,
Shunta Nakanishi,
Hiroki Kamehama
, et al. (1 additional authors not shown)
Abstract:
We have been developing monolithic active pixel sensors, X-ray Astronomy SOI pixel sensors, XRPIXs, based on a Silicon-On-Insulator (SOI) CMOS technology as soft X-ray sensors for a future Japanese mission, FORCE (Focusing On Relativistic universe and Cosmic Evolution). The mission is characterized by broadband (1-80 keV) X-ray imaging spectroscopy with high angular resolution ($<15$~arcsec), with…
▽ More
We have been developing monolithic active pixel sensors, X-ray Astronomy SOI pixel sensors, XRPIXs, based on a Silicon-On-Insulator (SOI) CMOS technology as soft X-ray sensors for a future Japanese mission, FORCE (Focusing On Relativistic universe and Cosmic Evolution). The mission is characterized by broadband (1-80 keV) X-ray imaging spectroscopy with high angular resolution ($<15$~arcsec), with which we can achieve about ten times higher sensitivity in comparison to the previous missions above 10~keV. Immediate readout of only those pixels hit by an X-ray is available by an event trigger output function implemented in each pixel with the time resolution higher than $10~{\rm μsec}$ (Event-Driven readout mode). It allows us to do fast timing observation and also reduces non-X-ray background dominating at a high X-ray energy band above 5--10~keV by adopting an anti-coincidence technique. In this paper, we introduce our latest results from the developments of the XRPIXs. (1) We successfully developed a 3-side buttable back-side illumination device with an imaging area size of 21.9~mm$\times$13.8~mm and an pixel size of $36~{\rm μm} \times 36~{\rm μm}$. The X-ray throughput with the device reaches higher than 0.57~kHz in the Event-Driven readout mode. (2) We developed a device using the double SOI structure and found that the structure improves the spectral performance in the Event-Driven readout mode by suppressing the capacitive coupling interference between the sensor and circuit layers. (3) We also developed a new device equipped with the Pinned Depleted Diode structure and confirmed that the structure reduces the dark current generated at the interface region between the sensor and the SiO$_2$ insulator layers. The device shows an energy resolution of 216~eV in FWHM at 6.4~keV in the Event-Driven readout mode.
△ Less
Submitted 29 July, 2018;
originally announced July 2018.
-
Improving Charge-Collection Efficiency of Kyoto's SOI Pixel Sensors
Authors:
Hideaki Matsumura,
Takeshi Go Tsuru,
Takaaki Tanaka,
Ayaki Takeda,
Makoto Ito,
Syunichi Ohmura,
Yasuo Arai,
Koji Mori,
Yusuke Nishioka,
Ryota Takenaka,
Takayoshi Kohmura
Abstract:
We have been developing X-ray SOIPIXs for next-generation satellites for X-ray astronomy. Their high time resolution ($\sim10~μ$s) and event-trigger-output function enable us to read out without pile-ups and to use anti-coincidence systems. Their performance in imaging spectroscopy is comparable to that in the CCDs. A problem in our previous model was degradation of charge-collection efficiency (C…
▽ More
We have been developing X-ray SOIPIXs for next-generation satellites for X-ray astronomy. Their high time resolution ($\sim10~μ$s) and event-trigger-output function enable us to read out without pile-ups and to use anti-coincidence systems. Their performance in imaging spectroscopy is comparable to that in the CCDs. A problem in our previous model was degradation of charge-collection efficiency (CCE) at pixel borders. We measured the response in the sub-pixel scale, using finely collimated X-ray beams at $10~μ$mΦ$ at SPring-8, and investigated the non-uniformity of the CCE within a pixel. We found that the X-ray detection efficiency and CCE degrade in the sensor region under the pixel circuitry placed outside the buried p-wells (BPW). A 2D simulation of the electric fields shows that the isolated pixel-circuitry outside the BPW creates local minimums in the electric potentials at the interface between the sensor and buried oxide layers. Thus, a part of signal charge is trapped there and is not collected to the BPW. Based on this result, we modified the placement of the in-pixel circuitry so that the electric fields would converge toward the BPW. We confirmed that the CCE at pixel borders is successfully improved with the updated model.
△ Less
Submitted 1 September, 2015;
originally announced September 2015.
-
Investigation of the Kyoto's X-ray Astronomical SOIPIXs with Double-SOI Wafer for Reduction of Cross-talks
Authors:
Shunichi Ohmura,
Takeshi Go Tsuru,
Takaaki Tanaka,
Ayaki Takeda,
Hideaki Matsumura,
Ito Makoto,
Shinya Nakashima,
Yasuo Arai,
Koji Mori,
Ryota Takenaka,
Yusuke Nishioka,
Takayoshi Kohmura,
Kouki Tamasawa
Abstract:
We have been developing X-ray SOIPIXs, "XRPIX", for future X-ray astronomy satellites. XRPIX is equipped with a function of "event-driven readout", which allows us to readout signal hit pixels only and realizes a high time resolution ($\sim10μ{\rm s}$). The current version of XRPIX suffers a problem that the readout noise in the event-driven readout mode is higher than that in the the frame readou…
▽ More
We have been developing X-ray SOIPIXs, "XRPIX", for future X-ray astronomy satellites. XRPIX is equipped with a function of "event-driven readout", which allows us to readout signal hit pixels only and realizes a high time resolution ($\sim10μ{\rm s}$). The current version of XRPIX suffers a problem that the readout noise in the event-driven readout mode is higher than that in the the frame readout mode, in which all the pixels are read out serially. Previous studies have clarified that the problem is caused by the cross-talks between buried P-wells (BPW) in the sensor layer and in-pixel circuits in the circuit layer. Thus, we developed new XRPIX having a Double SOI wafer (DSOI), which has an additional silicon layer (middle silicon) working as an electrical shield between the BPW and the in-pixel circuits. After adjusting the voltage applied to the middle silicon, we confirmed the reduction of the cross-talk by observing the analog waveform of the pixel circuit. We also successfully detected $^{241}$Am X-rays with XRPIX.
△ Less
Submitted 21 August, 2015;
originally announced August 2015.
-
Light Dark Matter Search with SOIPIX
Authors:
Naoya Oka,
Kentaro Miuchi,
Takeshi G. Tsuru,
Ayaki Takeda,
Hideaki Matsumura
Abstract:
We propose a light dark matter search experiment using an SOI pixel detector (SOIPIX). The event-driven SOIPIX can be a powerful tool for detecting light WIMPs because of its low energy threshold (< 1 keV) and high timing resolution (few μs). In this study, we evaluate the performance of an SOIPIX prototype detector and we examine the required specifications of SOIPIX for our target sensitivity.
We propose a light dark matter search experiment using an SOI pixel detector (SOIPIX). The event-driven SOIPIX can be a powerful tool for detecting light WIMPs because of its low energy threshold (< 1 keV) and high timing resolution (few μs). In this study, we evaluate the performance of an SOIPIX prototype detector and we examine the required specifications of SOIPIX for our target sensitivity.
△ Less
Submitted 24 July, 2015;
originally announced July 2015.
-
Study of the basic performance of the XRPIX for the future astronomical X-ray satellite
Authors:
Koki Tamasawa,
Takayoshi Kohmura,
Takahiro Konno,
Takeshi Go Tsuru,
Takaaki Tanaka,
Ayaki Takeda,
Hideaki Matsumura,
Koji Mori,
Yusuke Nishioka,
Ryota Takenaka
Abstract:
We have developed CMOS imaging sensor (XRPIX) using SOI (Silicon-On-Insulator) technology for the X-ray astronomical use. XRPIX(X-Ray soiPIXel) has advantage of a high time resolution, a high position resolution and an observation in a wide X-ray energy band with a thick depletion layer of over 200um.
However, the energy resolution of XRPIX is not as good as one of X-ray CCD. Therefore improveme…
▽ More
We have developed CMOS imaging sensor (XRPIX) using SOI (Silicon-On-Insulator) technology for the X-ray astronomical use. XRPIX(X-Ray soiPIXel) has advantage of a high time resolution, a high position resolution and an observation in a wide X-ray energy band with a thick depletion layer of over 200um.
However, the energy resolution of XRPIX is not as good as one of X-ray CCD. Therefore improvement of the the energy resolution is one of the most important development item of XRPIX. In order to evaluate the performance XRPIX more precisely, we have investigated on the temperature dependence of the basic performance, such as readout noise, leak current, gain and energy resolution, using two type of XRPIX, XRPIX1 and XRPIX2b_CZ.
In our study, we confirmed the readout noise, the leak current noise and the energy resolution clearly depended on the operating temperature of XRPIX. In addition, we divided the readout noise into the leak current noise and the circuit origin noise. As a result, we found that noise of the electronic circuitry origin was proportional to the square root of operating temperature.
△ Less
Submitted 24 July, 2015;
originally announced July 2015.
-
Development of time projection chamber for precise neutron lifetime measurement using pulsed cold neutron beams
Authors:
Y. Arimoto,
N. Higashi,
Y. Igarashi,
Y. Iwashita,
T. Ino,
R. Katayama,
R. Kitahara,
M. Kitaguchi,
H. Matsumura,
K. Mishima,
H. Oide,
H. Otono,
R. Sakakibara,
T. Shima,
H. M. Shimizu,
T. Sugino,
N. Sumi,
H. Sumino,
K. Taketani,
G. Tanaka,
M. Tanaka,
K. Tauchi,
A. Toyoda,
T. Yamada,
S. Yamashita
, et al. (2 additional authors not shown)
Abstract:
A new time projection chamber (TPC) was developed for neutron lifetime measurement using a pulsed cold neutron spallation source at the Japan Proton Accelerator Research Complex (J-PARC). Managing considerable background events from natural sources and the beam radioactivity is a challenging aspect of this measurement. To overcome this problem, the developed TPC has unprecedented features such as…
▽ More
A new time projection chamber (TPC) was developed for neutron lifetime measurement using a pulsed cold neutron spallation source at the Japan Proton Accelerator Research Complex (J-PARC). Managing considerable background events from natural sources and the beam radioactivity is a challenging aspect of this measurement. To overcome this problem, the developed TPC has unprecedented features such as the use of polyether-ether-ketone plates in the support structure and internal surfaces covered with $^6$Li-enriched tiles to absorb outlier neutrons. In this paper, the design and performance of the new TPC are reported in detail.
△ Less
Submitted 11 September, 2015; v1 submitted 26 March, 2015;
originally announced March 2015.
-
Radionuclides in the Cooling Water Systems for the NuMi Beamline and the Antiproton Production Target Station at Fermilab
Authors:
Hiroshi Matsumura,
Akihiro Toyoda,
Kotaro Bessho,
Shun Sekimoto,
Hiroshi Yashima,
Yoshimi Kasugai,
Norihiro Matsuda,
Yukio Sakamoto,
Hiroshi Nakashima,
Koji Oishi,
David Boehnlein,
Gary Lauten,
Anthony Leveling,
Nikolai Mokhov,
Kamran Vaziri
Abstract:
At the 120-GeV proton accelerator facilities of Fermilab, USA, water samples were collected from the cooling water systems for the target, magnetic horn1, magnetic horn2, decay pipe, and hadron absorber at the NuMI beamline as well as from the cooling water systems for the collection lens, pulse magnet and collimator, and beam absorber at the antiproton production target station, just after the sh…
▽ More
At the 120-GeV proton accelerator facilities of Fermilab, USA, water samples were collected from the cooling water systems for the target, magnetic horn1, magnetic horn2, decay pipe, and hadron absorber at the NuMI beamline as well as from the cooling water systems for the collection lens, pulse magnet and collimator, and beam absorber at the antiproton production target station, just after the shutdown of the accelerators for a maintenance period. Specific activities of γ -emitting radionuclides and 3H in these samples were determined using high-purity germanium detectors and a liquid scintillation counter. The cooling water contained various radionuclides depending on both major and minor materials in contact with the water. The activity of the radionuclides depended on the presence of a deionizer. Specific activities of 3H were used to estimate the residual rates of 7Be. The estimated residual rates of 7Be in the cooling water were approximately 5% for systems without deionizers and less than 0.1% for systems with deionizers, although the deionizers function to remove 7Be from the cooling water.
△ Less
Submitted 29 August, 2014;
originally announced September 2014.
-
Development and Performance of Kyoto's X-ray Astronomical SOI pixel (SOIPIX) sensor
Authors:
Takeshi G. Tsuru,
Hideaki Matsumura,
Ayaki Takeda,
Takaaki Tanaka,
Shinya Nakashima,
Yasuo Arai,
Koji Mori,
Ryota Takenaka,
Yusuke Nishioka,
Takayoshi Kohmura,
Takaki Hatsui,
Takashi Kameshima,
Kyosuke Ozaki,
Yoshiki Kohmura,
Tatsuya Wagai,
Dai Takei,
Shoji Kawahito,
Keiichiro Kagawa,
Keita Yasutomi,
Hiroki Kamehama,
Sumeet Shrestha
Abstract:
We have been developing monolithic active pixel sensors, known as Kyoto's X-ray SOIPIXs, based on the CMOS SOI (silicon-on-insulator) technology for next-generation X-ray astronomy satellites. The event trigger output function implemented in each pixel offers microsecond time resolution and enables reduction of the non-X-ray background that dominates the high X-ray energy band above 5--10 keV. A f…
▽ More
We have been developing monolithic active pixel sensors, known as Kyoto's X-ray SOIPIXs, based on the CMOS SOI (silicon-on-insulator) technology for next-generation X-ray astronomy satellites. The event trigger output function implemented in each pixel offers microsecond time resolution and enables reduction of the non-X-ray background that dominates the high X-ray energy band above 5--10 keV. A fully depleted SOI with a thick depletion layer and back illumination offers wide band coverage of 0.3--40 keV. Here, we report recent progress in the X-ray SOIPIX development. In this study, we achieved an energy resolution of 300~eV (FWHM) at 6~keV and a read-out noise of 33~e- (rms) in the frame readout mode, which allows us to clearly resolve Mn-K$α$ and K$β$. Moreover, we produced a fully depleted layer with a thickness of $500~{\rm μm}$. The event-driven readout mode has already been successfully demonstrated.
△ Less
Submitted 20 August, 2014;
originally announced August 2014.
-
Shielding Experiments Under JASMIN Collaboration at Fermilab(III) - Measurement of High-Energy Neutrons Penetrating a Thick Iron Shield from the Antiproton Production Target by AU Activation Method
Authors:
H. Matsumura,
N. Kinoshita,
H. Iwase,
A. Toyoda,
Y. Kasugai,
N. Matsuda,
Y. Sakamoto,
H. Nakashima,
H. Yashima,
N. Mokhov,
A. Leveling,
D. Boehlein,
K. Vaziri,
G. Lautenschlager,
W. Schmitt,
K. Oishi
Abstract:
In an antiproton production (Pbar) target station of the Fermi National Accelerator Laboratory (FNAL), the secondary particles produced by bombarding a target with 120-GeV protons are shielded by a thick iron shield. In order to obtain experimental data on high-energy neutron transport at more than 100-GeV-proton accelerator facilities, we indirectly measured more than 100-MeV neutrons at the outs…
▽ More
In an antiproton production (Pbar) target station of the Fermi National Accelerator Laboratory (FNAL), the secondary particles produced by bombarding a target with 120-GeV protons are shielded by a thick iron shield. In order to obtain experimental data on high-energy neutron transport at more than 100-GeV-proton accelerator facilities, we indirectly measured more than 100-MeV neutrons at the outside of the iron shield at an angle of 50° in the Pbar target station. The measurement was performed by using the Au activation method coupled with a low-background γ-ray counting system. As an indicator for the neutron flux, we determined the production rates of 8 spallation nuclides (196-Au, 188-Pt, 189-Ir, 185-Os, 175-Hf, 173-Lu, 171-Lu, and 169-Yb) in the Au activation detector. The measured production rates were compared with the theoretical production rates calculated using PHITS. We proved that the Au activation method can serve as a powerful tool for indirect measurements of more than 100-MeV neutrons that play a vital role in neutron transport. These results will be important for clarifying the problems in theoretical calculations of high-energy neutron transport.
△ Less
Submitted 1 May, 2012;
originally announced May 2012.
-
Shielding experiments by the JASMIN collaboration at Fermilab (II) - Radioactivity measurement induced by secondary particles from the anti-proton production target
Authors:
Hiroshi Yashima,
Norihiro Matsuda,
Yoshimi Kasugai,
Hiroshi Matsumura,
Hiroshi Iwase,
Norikazu Kinoshita,
David Boehnlein,
Gary Lauten,
Anthony Leveling,
Nikolai Mokhov,
Kamran Vaziri,
Koji Oishi,
Hiroshi Nakashima,
Yukio Sakamoto
Abstract:
The JASMIN Collaboration has performed an experiment to conduct measurements of nuclear reaction rates around the anti-proton production (Pbar) target at the Fermi National Accelerator Laboratory (FNAL). At the Pbar target station, the target, consisting an Inconel 600 cylinder, was irradiated by a 120 GeV/c proton beam from the FNAL Main Injector. The beam intensity was 3.6 x 10**12 protons per s…
▽ More
The JASMIN Collaboration has performed an experiment to conduct measurements of nuclear reaction rates around the anti-proton production (Pbar) target at the Fermi National Accelerator Laboratory (FNAL). At the Pbar target station, the target, consisting an Inconel 600 cylinder, was irradiated by a 120 GeV/c proton beam from the FNAL Main Injector. The beam intensity was 3.6 x 10**12 protons per second. Samples of Al, Nb, Cu, and Au were placed near the target to investigate the spatial and energy distribution of secondary particles emitted from it. After irradiation, the induced activities of the samples were measured by studying their gamma ray spectra using HPGe detectors. The production rates of 30 nuclides induced in Al, Nb, Cu, Au samples were obtained. These rates increase for samples placed in a forward (small angle) position relative to the target. The angular dependence of these reaction rates becomes larger for increasing threshold energy. These experimental results are compared with Monte Carlo calculations. The calculated results generally agree with the experimental results to within a factor of 2 to 3.
△ Less
Submitted 16 February, 2012;
originally announced February 2012.
-
JASMIN: Japanese-American study of muon interactions and neutron detection
Authors:
Hiroshi Nakashima,
N. V. Mokhov,
Yoshimi Kasugai,
Norihiro Matsuda,
Yosuke Iwamoto,
Yukio Sakamoto,
Anthony F. Leveling,
David J. Boehnlein,
Kamran Vaziri,
Hiroshi Matsumura,
Masayuki Hagiwara,
Hiroshi Iwase,
Syuichi Ban,
Hideo Hirayama,
Takashi Nakamura,
Koji Oishi,
Nobuhiro Shigyo,
Hiroyuki Arakawa,
Tsuyoshi Kajimoto,
Kenji Ishibashi,
Hiroshi Yashima,
Shun Sekimoto,
Norikazu Kinoshita,
Hee-Seock Lee,
Koji Niita
Abstract:
Experimental studies of shielding and radiation effects at Fermi National Accelerator Laboratory (FNAL) have been carried out under collaboration between FNAL and Japan, aiming at benchmarking of simulation codes and study of irradiation effects for upgrade and design of new high-energy accelerator facilities. The purposes of this collaboration are (1) acquisition of shielding data in a proton bea…
▽ More
Experimental studies of shielding and radiation effects at Fermi National Accelerator Laboratory (FNAL) have been carried out under collaboration between FNAL and Japan, aiming at benchmarking of simulation codes and study of irradiation effects for upgrade and design of new high-energy accelerator facilities. The purposes of this collaboration are (1) acquisition of shielding data in a proton beam energy domain above 100 GeV; (2) further evaluation of predictive accuracy of the PHITS and MARS codes; (3) modification of physics models and data in these codes if needed; (4) establishment of irradiation field for radiation effect tests; and (5) development of a code module for improved description of radiation effects. A series of experiments has been performed at the Pbar target station and NuMI facility, using irradiation of targets with 120 GeV protons for antiproton and neutrino production, as well as the M-test beam line (M-test) for measuring nuclear data and detector responses. Various nuclear and shielding data have been measured by activation methods with chemical separation techniques as well as by other detectors such as a Bonner ball counter. Analyses with the experimental data are in progress for benchmarking the PHITS and MARS15 codes. In this presentation recent activities and results are reviewed.
△ Less
Submitted 9 February, 2012;
originally announced February 2012.