Skip to main content

Showing 1–8 of 8 results for author: Martemiyanov, A

Searching in archive physics. Search in all archives.
.
  1. arXiv:1912.11107  [pdf, other

    physics.ins-det physics.bio-ph

    Assessment of the potential of SiPM-based systems for bioluminescence detection

    Authors: S. Lomazzi, M. Caccia, C. Distasi, M. Dionisi, D. Lim, A. Martemiyanov, L. Nardo, F. A. Ruffinatti, R. Santoro

    Abstract: Bioluminescence detection requires single-photon sensitivity, extremely low detection limits and wide dynamic range. Such performances were traditionally assured by photomultiplier-tubes based systems. However, development of novel applications and industrialisation call for the introduction of more robust, compact and scalable devices. Silicon photomultipliers were recently put forward as the alt… ▽ More

    Submitted 23 December, 2019; originally announced December 2019.

  2. Test of SensL SiPM coated with NOL-1 wavelength shifter in liquid xenon

    Authors: D. Yu. Akimov, V. A. Belov, O. V. Borshchev, A. A. Burenkov, Yu. L. Grishkin, A. K. Karelin, A. V. Kuchenkov, A. N. Martemiyanov, S. A. Ponomarenko, G. E. Simakov, V. N. Stekhanov, N. M. Surin, V. S. Timoshin, O. Ya. Zeldovich

    Abstract: A SensL MicroFC-SMT-60035 6x6 mm$^2$ silicon photo-multiplier coated with a NOL-1 wavelength shifter have been tested in the liquid xenon to detect the 175-nm scintillation light. For comparison, a Hamamatsu vacuum ultraviolet sensitive MPPC VUV3 3x3 mm$^2$ was tested under the same conditions. The photodetection efficiency of $13.1 \pm 2.5$% and $6.0 \pm 1.0$%, correspondingly, is obtained.

    Submitted 3 May, 2017; v1 submitted 5 April, 2017; originally announced April 2017.

    Comments: 8 pages, 4 figures

  3. arXiv:1308.3622  [pdf, other

    physics.ins-det physics.ed-ph

    An Educational Kit Based on a Modular Silicon Photomultiplier System

    Authors: V. Arosio, M. Caccia, V. Chmill, A. Ebolese, A. Martemiyanov, F. Risigo, R. Santoro, M. Locatelli, M. Pieracci, C. Tintori

    Abstract: Silicon Photo-Multipliers (SiPM) are state of the art light detectors with unprecedented single photon sensitivity and photon number resolving capability, representing a breakthrough in several fundamental and applied Science domains. An educational experiment based on a SiPM set-up is proposed in this article, guiding the student towards a comprehensive knowledge of this sensor technology while e… ▽ More

    Submitted 30 June, 2014; v1 submitted 16 August, 2013; originally announced August 2013.

  4. Long-term operation of a multi-channel cosmic muon system based on scintillation counters with MRS APD light readout

    Authors: A. Akindinov, V. Golovin, E. Grigoriev, Yu. Grishuk, S. Kuleshov, D. Malkevich, A. Martemiyanov, A. Nedosekin, M. Ryabinin, K. Voloshin

    Abstract: A Cosmic Ray Test Facility (CRTF) is the first large-scale implementation of a scintillation triggering system based on a new scintillation technique known as START. In START, the scintillation light is collected and transported by WLS optical fibers, while light detection is performed by pairs of avalanche photodiodes with the Metal-Resistor-Semiconductor structure operated in the Geiger mode (… ▽ More

    Submitted 19 September, 2008; originally announced September 2008.

    Comments: Proceedings of NDIP-2008. 8 pages, 8 figures, 6 references

    Journal ref: Nucl.Instrum.Meth.A610:431-435,2009

  5. START as the detector of choice for large-scale muon triggering systems

    Authors: A. Akindinov, G. Bondarenko, V. Golovin, E. Grigoriev, Yu. Grishuk, D. Mal'kevich, A. Martemiyanov, A. Nedosekin, M. Ryabinin, V. Sheinkman, A. Smirnitskiy, K. Voloshin

    Abstract: Further progress in building high-granular large-scale systems based on Scintillation Tiles with MRS APD light readout (START) became possible thanks to the creation of an improved version of MRS APD. The cost of the system may now be significantly reduced by using inexpensive extruded scintillator. More than 160 START samples were assembled based on this design modification and proved to posses… ▽ More

    Submitted 24 May, 2006; originally announced May 2006.

    Comments: 7 pages, 2 figures, reported at the 4th International Conference on New Developments in Photodetection, Beaune, France, June 19-24, 2005

    Journal ref: Nucl.Instrum.Meth.A567:74-77,2006

  6. Scintillation counter with MRS APD light readout

    Authors: A. Akindinov, G. Bondarenko, V. Golovin, E. Grigoriev, Yu. Grishuk, D. Mal'kevich, A. Martemiyanov, M. Ryabinin, A. Smirnitskiy, K. Voloshin

    Abstract: START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs (Avalanche Photo-Diodes with Metal-Resistance-Semiconductor structure), operated in the Geiger mode, which have 1 mm^2 sensitive areas. START is assembled from a 15… ▽ More

    Submitted 27 March, 2006; originally announced March 2006.

    Comments: 6 pages, 5 figures

    Journal ref: Nucl.Instrum.Meth. A539 (2005) 172-176

  7. arXiv:physics/0502111  [pdf, ps, other

    physics.ins-det

    100 ps time-of-flight resolution of Dielectric Resistive Plate Chamber

    Authors: A. Akindinov, V. Golovin, A. Martemiyanov, V. Petrov, V. Plotnikov, A. Smirnitsky, K. Voloshin

    Abstract: Time of flight of a minimum ionizing particle along a fixed base has been measured with a 100 ps accuracy by means of a Dielectric Resistive Plate Chamber (DRPC) with 4 x 0.3 mm gas gaps. DRPC timing characteristics have been studied with different applied voltages, discriminating thresholds and beam intensities. It may be stated that the time-of-flight resolution of gaseous detectors developed… ▽ More

    Submitted 21 February, 2005; originally announced February 2005.

    Comments: 5 pages, 7 figures

    Report number: Preprint ITEP 20-99

  8. arXiv:physics/0410103  [pdf, ps, other

    physics.ins-det

    Dielectric Resistive Plate Chamber as a detector for time-of-flight measurements

    Authors: A. Akindinov, V. Golovin, A. Martemiyanov, V. Petrov, A. Smirnitskiy, K. Voloshin

    Abstract: Principles of operation, construction and first test results of a Dielectric Resistive Plate Chamber (DRPC) are described. The detector has shown stability of operation in the avalanche mode of gas amplfication within a wide range of applied voltages. Double-gap DRPCs have demonstrated the MIP registration efficiency of 97% and the time resolution of 180-200 ps. No changes in DRPC operation have… ▽ More

    Submitted 2 December, 2004; v1 submitted 15 October, 2004; originally announced October 2004.

    Comments: 8 pages, 7 figures text formatting and figures updated for better performance slight corrections made in the text

    Report number: ITEP 45 98