-
Estimation of absorbed dose in organs using Waza-AriV2 web-based software in head CT scans
Authors:
Juan Miguel Lozano,
Harley Alejo Martinez,
Edison Salazar,
Maria Esperanza Castellanos
Abstract:
Recently, Yamashita et al. reported direct measurements of ionizing radiation doses to individual organs in postmortem (using OSL dosimetry) that were exposed in the most frequent clinical CT scan protocols, corresponding to the whole body, head, thorax and abdomen. The authors compare the experimental results with the values calculated in the Waza-AriV2 software, which is a system based on the Mo…
▽ More
Recently, Yamashita et al. reported direct measurements of ionizing radiation doses to individual organs in postmortem (using OSL dosimetry) that were exposed in the most frequent clinical CT scan protocols, corresponding to the whole body, head, thorax and abdomen. The authors compare the experimental results with the values calculated in the Waza-AriV2 software, which is a system based on the MonteCarlo method that performs the estimation of organ doses from the exposure parameters used in the CT equipment. However, the results of the absorbed doses calculated in each examination had significant variations with respect to the doses measured directly in postmortem. In this communication, we made a calculation under the correct interpretation in one of the acquisition parameters (mA) which leads to a significant discrepancy between the estimated and measured values reported by Yamashita et al. We also make the comparison between the Waza-AriV2 and NCICT software.
△ Less
Submitted 10 September, 2021; v1 submitted 3 September, 2021;
originally announced September 2021.
-
A new experiment to test parity symmetry in cold chiral molecules using vibrational spectroscopy
Authors:
A Cournol,
M. Manceau,
M. Pierens,
L Lecordier,
D Tran,
R. Santagata,
B. Argence,
A Goncharov,
O. Lopez,
M. Abgrall,
Y. Le Coq,
R. Le Targat,
H Alvarez Martinez,
W Lee,
D Xu,
P-E Pottie,
R Hendricks,
T Wall,
J Bieniewska,
B Sauer,
M. Tarbutt,
A. Amy-Klein,
S. Tokunaga,
B. Darquié
Abstract:
We present a brief review of our progress towards measuring parity violation in heavy-metal chiral complexes using mid-infrared Ramsey interferometry. We discuss our progress addressing the main challenges, including the development of buffer-gas sources of slow, cold polyatomic molecules, and the frequency-stabilisation of quantum cascade lasers calibrated using primary frequency standards. We re…
▽ More
We present a brief review of our progress towards measuring parity violation in heavy-metal chiral complexes using mid-infrared Ramsey interferometry. We discuss our progress addressing the main challenges, including the development of buffer-gas sources of slow, cold polyatomic molecules, and the frequency-stabilisation of quantum cascade lasers calibrated using primary frequency standards. We report investigations on achiral test species of which promising chiral derivatives have been synthesized.
△ Less
Submitted 12 December, 2019;
originally announced December 2019.
-
Guidelines for developing optical clocks with $10^{-18}$ fractional frequency uncertainty
Authors:
Moustafa Abdel-Hafiz,
Piotr Ablewski,
Ali Al-Masoudi,
Héctor Álvarez Martínez,
Petr Balling,
Geoffrey Barwood,
Erik Benkler,
Marcin Bober,
Mateusz Borkowski,
William Bowden,
Roman Ciuryło,
Hubert Cybulski,
Alexandre Didier,
Miroslav Doležal,
Sören Dörscher,
Stephan Falke,
Rachel M. Godun,
Ramiz Hamid,
Ian R. Hill,
Richard Hobson,
Nils Huntemann,
Yann Le Coq,
Rodolphe Le Targat,
Thomas Legero,
Thomas Lindvall
, et al. (20 additional authors not shown)
Abstract:
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency…
▽ More
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups developing optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trapping, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with $1 \times 10^{-18}$ uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.
△ Less
Submitted 13 August, 2019; v1 submitted 27 June, 2019;
originally announced June 2019.