Skip to main content

Showing 1–6 of 6 results for author: Marlasca, F G

Searching in archive physics. Search in all archives.
.
  1. arXiv:2503.09520  [pdf, other

    physics.space-ph physics.ins-det

    Total Ionizing Dose Measurements in Small Satellites in LEO using LabOSat-01

    Authors: Lucas Finazzi, Mariano Barella, Fernando Gomez Marlasca, Lucas Sambuco Salomone, Sebastían Carbonetto, María Victoria Cassani, Eduardo Redín, Mariano García-Inza, Gabriel Sanca, Federico Golmar

    Abstract: LabOSat-01 is a payload designed to perform characterization experiments on electronic devices in hostile environments. Both Commercial-Off-The-Shelf components and custom nano and micro devices were studied in the last decade with this platform. The Total Ionizing Dose (TID) received by small satellites in Low Earth Orbit was measured with LabOSat-01 using p-MOSFET COTS and the results are presen… ▽ More

    Submitted 12 March, 2025; originally announced March 2025.

  2. Characterization of SiPM Performance in a Small Satellite in Low Earth Orbit using LabOSat-01

    Authors: Lucas Finazzi, Federico Izraelevitch, Mariano Barella, Fernando Gomez Marlasca, Gabriel Sanca, Federico Golmar

    Abstract: In this work, the performance of SensL MicroFC-60035 SiPM devices was studied during a 1460-day mission in Low Earth Orbit (LEO) using the LabOSat-01 characterization payload. Two of these platforms, carrying two SiPMs each, were integrated into the ÑuSat-7 satellite (COSPAR-ID: 2020-003B). Analysis revealed that these SiPMs experienced an increase in dark current over time due to damage from trap… ▽ More

    Submitted 22 August, 2024; v1 submitted 10 July, 2024; originally announced July 2024.

  3. arXiv:2103.00350  [pdf, ps, other

    cond-mat.mtrl-sci physics.app-ph

    Proton irradiation effects on metal-YBCO interfaces

    Authors: C. Acha, G. A. Sanca, M. Barella, M. Alurralde, F. Gomez Marlasca, H. Huhtinen, P. Paturi, F. Golmar, P. Levy

    Abstract: 10 MeV proton-irradiation effects on a YBCO-based test structure were analyzed by measuring its current-voltage (IV) characteristics for different cumulated fluences. For fluences of up to $\sim$80$\cdot$10$^9$~p/cm$^2$ no changes in the electrical behavior of the device were observed, while for a fluence of $\sim$~300$\cdot$10$^9~$ p/cm$^2$ it becomes less conducting. A detailed analysis of the r… ▽ More

    Submitted 27 February, 2021; originally announced March 2021.

    Comments: 22 pages, 7 figures, corresponding author: [email protected]

    Journal ref: Radiation Physics and Chemistry (2021)

  4. arXiv:2007.00143  [pdf

    physics.ins-det physics.app-ph

    COTS MOS Dosimetry on the MeMOSat Board, Results After 2.5 Years in Orbit

    Authors: José Lipovetzky, Mariano Garcia-Inza, Macarena Rodríguez Cañete, Gabriel Redin, Sebastián Carbonetto, Martín Echarri, Federico Golmar, Fernando Gomez Marlasca, Mariano Barella, Gabriel A. Sanca, Pablo Levy, Adrián Faigón

    Abstract: We present the results after 2.5 years in or-bit of Total Ionizing Dose (TID) measurements done using Metal Oxide Semiconductor (MOS) dosimeters on the MeMOSat board. The MeMOSat board was launched on July 19th 2014 at the BugSat-1 "Tita" microsatellite developed by Satellogic to stay at LEO. We used as dosimeters p-channel Commercial Off The Shelf (COTS) MOS transistors with gate oxides of 250~nm… ▽ More

    Submitted 30 June, 2020; originally announced July 2020.

  5. arXiv:2007.00141  [pdf

    physics.ins-det physics.app-ph physics.space-ph

    LabOSat as a versatile payload for small satellites: first 100days in LEO orbit

    Authors: G. A. Sanca, M. Barella, F. Gomez Marlasca, G. Rodríguez, D. Martelliti, L. Patrone, P. Levy, F. Golmar

    Abstract: In this work the first results obtained by LabOSat-01 platform are presented. This platform was designed for testing custom devices on board of small satellites. Two LabOSat-01 type boards were launched and placed into Low Earth Orbit (LEO) on May 30, 2016. We present here an analysis of data collected by one of these boards during the first days of mission. Total Ionization Dose results are compa… ▽ More

    Submitted 30 June, 2020; originally announced July 2020.

  6. arXiv:2006.15062  [pdf, ps, other

    physics.app-ph cond-mat.mtrl-sci

    YBCO-based non-volatile ReRAM tested in Low Earth Orbit

    Authors: C. Acha, M. Barella, G. A. Sanca, F. Gomez Marlasca, H. Huhtinen, P. Paturi, P. Levy, F. Golmar

    Abstract: An YBCO-based test structure corresponding to the family of ReRAM devices associated with the valence change mechanism is presented. We have characterized its electrical response previous to its lift-off to a Low Earth Orbit (LEO) using standard electronics and also with the dedicated LabOSat-01 controller. Similar results were obtained in both cases. After about 200 days at LEO on board a small s… ▽ More

    Submitted 26 June, 2020; originally announced June 2020.

    Comments: 20 pages, 11 figures

    Journal ref: Journal of Materials Science: Materials in Electronics (2020)