Total Ionizing Dose Measurements in Small Satellites in LEO using LabOSat-01
Authors:
Lucas Finazzi,
Mariano Barella,
Fernando Gomez Marlasca,
Lucas Sambuco Salomone,
Sebastían Carbonetto,
María Victoria Cassani,
Eduardo Redín,
Mariano García-Inza,
Gabriel Sanca,
Federico Golmar
Abstract:
LabOSat-01 is a payload designed to perform characterization experiments on electronic devices in hostile environments. Both Commercial-Off-The-Shelf components and custom nano and micro devices were studied in the last decade with this platform. The Total Ionizing Dose (TID) received by small satellites in Low Earth Orbit was measured with LabOSat-01 using p-MOSFET COTS and the results are presen…
▽ More
LabOSat-01 is a payload designed to perform characterization experiments on electronic devices in hostile environments. Both Commercial-Off-The-Shelf components and custom nano and micro devices were studied in the last decade with this platform. The Total Ionizing Dose (TID) received by small satellites in Low Earth Orbit was measured with LabOSat-01 using p-MOSFET COTS and the results are presented in this work. Measurements were performed on two satellite missions, each totalling 1100 days, launched three years apart. Dosimeters were integrated in different satellite positions, with different shielding, and the measured TID after 1100 days ranged from 5 Gy to 19 Gy.
△ Less
Submitted 12 March, 2025;
originally announced March 2025.
-
Characterization of SiPM Performance in a Small Satellite in Low Earth Orbit using LabOSat-01
Authors:
Lucas Finazzi,
Federico Izraelevitch,
Mariano Barella,
Fernando Gomez Marlasca,
Gabriel Sanca,
Federico Golmar
Abstract:
In this work, the performance of SensL MicroFC-60035 SiPM devices was studied during a 1460-day mission in Low Earth Orbit (LEO) using the LabOSat-01 characterization payload. Two of these platforms, carrying two SiPMs each, were integrated into the ÑuSat-7 satellite (COSPAR-ID: 2020-003B). Analysis revealed that these SiPMs experienced an increase in dark current over time due to damage from trap…
▽ More
In this work, the performance of SensL MicroFC-60035 SiPM devices was studied during a 1460-day mission in Low Earth Orbit (LEO) using the LabOSat-01 characterization payload. Two of these platforms, carrying two SiPMs each, were integrated into the ÑuSat-7 satellite (COSPAR-ID: 2020-003B). Analysis revealed that these SiPMs experienced an increase in dark current over time due to damage from trapped and solar proton radiation. The total ionizing dose received by the payload and the SiPMs was measured using p-MOSFET dosimeters, with a resulting value of 5 Gy, or a 1 MeV neutron equivalent fluence of $φ_n = 5 \cdot 10^9$ n/cm$^2$. The dark current was observed to increase up to 500 times. Parameters such as Gain and Photon Detection Efficiency remained unchanged throughout the mission. These findings align with previous performance reports involving different SiPMs irradiated with various particles and energies.
△ Less
Submitted 22 August, 2024; v1 submitted 10 July, 2024;
originally announced July 2024.
-
Proton irradiation effects on metal-YBCO interfaces
Authors:
C. Acha,
G. A. Sanca,
M. Barella,
M. Alurralde,
F. Gomez Marlasca,
H. Huhtinen,
P. Paturi,
F. Golmar,
P. Levy
Abstract:
10 MeV proton-irradiation effects on a YBCO-based test structure were analyzed by measuring its current-voltage (IV) characteristics for different cumulated fluences. For fluences of up to $\sim$80$\cdot$10$^9$~p/cm$^2$ no changes in the electrical behavior of the device were observed, while for a fluence of $\sim$~300$\cdot$10$^9~$ p/cm$^2$ it becomes less conducting. A detailed analysis of the r…
▽ More
10 MeV proton-irradiation effects on a YBCO-based test structure were analyzed by measuring its current-voltage (IV) characteristics for different cumulated fluences. For fluences of up to $\sim$80$\cdot$10$^9$~p/cm$^2$ no changes in the electrical behavior of the device were observed, while for a fluence of $\sim$~300$\cdot$10$^9~$ p/cm$^2$ it becomes less conducting. A detailed analysis of the room temperature IV characteristics based on the $γ$ power exponent parameter [$γ=dLn(I)/dLn(V)$] allowed us to reveal the main conduction mechanisms as well as to establish the equivalent circuit model of the device. The changes produced in the electrical behavior, in accordance with Monte Carlo TRIM simulations, suggest that the main effect induced by protons is the displacement of oxygen atoms within the YBCO lattice, particularly from oxygen-rich to oxygen-poor areas, where they become trapped.
△ Less
Submitted 27 February, 2021;
originally announced March 2021.
-
COTS MOS Dosimetry on the MeMOSat Board, Results After 2.5 Years in Orbit
Authors:
José Lipovetzky,
Mariano Garcia-Inza,
Macarena Rodríguez Cañete,
Gabriel Redin,
Sebastián Carbonetto,
Martín Echarri,
Federico Golmar,
Fernando Gomez Marlasca,
Mariano Barella,
Gabriel A. Sanca,
Pablo Levy,
Adrián Faigón
Abstract:
We present the results after 2.5 years in or-bit of Total Ionizing Dose (TID) measurements done using Metal Oxide Semiconductor (MOS) dosimeters on the MeMOSat board. The MeMOSat board was launched on July 19th 2014 at the BugSat-1 "Tita" microsatellite developed by Satellogic to stay at LEO. We used as dosimeters p-channel Commercial Off The Shelf (COTS) MOS transistors with gate oxides of 250~nm…
▽ More
We present the results after 2.5 years in or-bit of Total Ionizing Dose (TID) measurements done using Metal Oxide Semiconductor (MOS) dosimeters on the MeMOSat board. The MeMOSat board was launched on July 19th 2014 at the BugSat-1 "Tita" microsatellite developed by Satellogic to stay at LEO. We used as dosimeters p-channel Commercial Off The Shelf (COTS) MOS transistors with gate oxides of 250~nm. Before launch, a subset of transistors with similar drain current to voltage (I-V)curves where selected from a group of 100 devices. The temperature dependence of the (I-V) curves was studied to find the minimum temperature coefficient biasing point. Then, a calibration subgroup of sensors was irradiated using a $^{60}$Co gamma source to study their response to TID, showing responsivities of $\sim$75~mV/krad when the sensors are irradiated without gate bias. Also, the post irradiation response of the sensors was monitored, in order to include a correction for low dose rate irradiations, yielding 30~mV/krad. A biasing and reading circuit was developed in order to allow the reading of up to 4 sensors.The threshold voltage was monitored during different periods of the mission. After 2.5 years in orbit,the threshold voltage of the sensor mounted on the MeMOSat Board had a V$_\mathrm{T}$ shift of approximately 35~mV corresponds to a dose of 1.2~krads.
△ Less
Submitted 30 June, 2020;
originally announced July 2020.
-
LabOSat as a versatile payload for small satellites: first 100days in LEO orbit
Authors:
G. A. Sanca,
M. Barella,
F. Gomez Marlasca,
G. Rodríguez,
D. Martelliti,
L. Patrone,
P. Levy,
F. Golmar
Abstract:
In this work the first results obtained by LabOSat-01 platform are presented. This platform was designed for testing custom devices on board of small satellites. Two LabOSat-01 type boards were launched and placed into Low Earth Orbit (LEO) on May 30, 2016. We present here an analysis of data collected by one of these boards during the first days of mission. Total Ionization Dose results are compa…
▽ More
In this work the first results obtained by LabOSat-01 platform are presented. This platform was designed for testing custom devices on board of small satellites. Two LabOSat-01 type boards were launched and placed into Low Earth Orbit (LEO) on May 30, 2016. We present here an analysis of data collected by one of these boards during the first days of mission. Total Ionization Dose results are compared with data acquired by LabOSat-01`s predecessor board, MeMOSat-01, launched in 2014.
△ Less
Submitted 30 June, 2020;
originally announced July 2020.
-
YBCO-based non-volatile ReRAM tested in Low Earth Orbit
Authors:
C. Acha,
M. Barella,
G. A. Sanca,
F. Gomez Marlasca,
H. Huhtinen,
P. Paturi,
P. Levy,
F. Golmar
Abstract:
An YBCO-based test structure corresponding to the family of ReRAM devices associated with the valence change mechanism is presented. We have characterized its electrical response previous to its lift-off to a Low Earth Orbit (LEO) using standard electronics and also with the dedicated LabOSat-01 controller. Similar results were obtained in both cases. After about 200 days at LEO on board a small s…
▽ More
An YBCO-based test structure corresponding to the family of ReRAM devices associated with the valence change mechanism is presented. We have characterized its electrical response previous to its lift-off to a Low Earth Orbit (LEO) using standard electronics and also with the dedicated LabOSat-01 controller. Similar results were obtained in both cases. After about 200 days at LEO on board a small satellite, electrical tests started on the memory device using the LabOSat-01 controller. We discuss the results of the first 150 tests, performed along a 433-day time interval in space. The memory device remained operational despite the hostile conditions that involved launching, lift-off vibrations, permanent thermal cycling and exposure to ionizing radiation, with doses 3 orders of magnitude greater than the usual ones on Earth. The device showed resistive switching and IV characteristics similar to those measured on Earth, although with changes that follow a smooth drift in time. A detailed study of the electrical transport mechanisms, based on previous models that indicate the existence of various conducting mechanisms through the metal-YBCO interface showed that the observed drift can be associated with a local temperature drift at the LabOSat controller, with no clear evidence that allows determining changes in the underlying microscopic factors. These results show the reliability of complex-oxide non-volatile ReRAM-based devices in order to operate under all the hostile conditions encountered in space-borne applications.
△ Less
Submitted 26 June, 2020;
originally announced June 2020.