-
An array of bulk-acoustic-wave sensors as a high-frequency antenna for gravitational waves
Authors:
G. Albani,
M. Borghesi,
L. Canonica,
R. Carobene,
F. De Guio,
M. Faverzani,
E. Ferri,
R. Gerosa,
A. Ghezzi,
A. Giachero,
C. Gotti,
D. Labranca,
L. Mariani,
A. Nucciotti,
G. Pessina,
D. Rozza,
T. Tabarelli de Fatis
Abstract:
In their simplest form, bulk acoustic wave (BAW) devices consist of a piezoelectric crystal between two electrodes that transduce the material's vibrations into electrical signals. They are adopted in frequency control and metrology, with well-established standards at frequencies of 5~MHz and above. Their use as a resonant-mass strain antenna for high-frequency gravitational waves has been recentl…
▽ More
In their simplest form, bulk acoustic wave (BAW) devices consist of a piezoelectric crystal between two electrodes that transduce the material's vibrations into electrical signals. They are adopted in frequency control and metrology, with well-established standards at frequencies of 5~MHz and above. Their use as a resonant-mass strain antenna for high-frequency gravitational waves has been recently proposed (Goryachev and Tobar, 2014). The estimated power spectral density sensitivity at the resonant frequencies is of the order of $10^{-21}\, \textrm{strain}/\sqrt{\textrm{Hz}}$. In this paper, after introducing the science opportunity and potential of gravitational wave detection with BAWs, we describe the two-stage BAUSCIA project plan to build a multimode antenna based on commercial BAWs, followed by an optimized array of custom BAWs. We show that commercially available BAWs already provide sensitivity comparable to current experiments around 10~MHz. Finally, we outline options for optimization of custom devices to improve sensitivity in an unexplored region, probe multiple frequencies between 0.1 and 10 MHz, and target specific signals, such as post-merger emission from neutron stars or emission from various dark matter candidates.
△ Less
Submitted 20 June, 2025;
originally announced June 2025.
-
Quantum Key Distribution over Complex Networks
Authors:
Luca Mariani,
Raja Yehia,
Carlos Pascual-García,
Federico Centrone,
Jasper van der Kolk,
M. Ángeles Serrano,
Antonio Acín
Abstract:
There exist several initiatives worldwide to deploy quantum key distribution (QKD) over existing fibre networks and achieve quantum-safe security at large scales. To understand the overall QKD network performance, it is required to transition from the analysis of individual links, as done so far, to the characterization of the network as a whole. In this work, we undertake this study by embedding…
▽ More
There exist several initiatives worldwide to deploy quantum key distribution (QKD) over existing fibre networks and achieve quantum-safe security at large scales. To understand the overall QKD network performance, it is required to transition from the analysis of individual links, as done so far, to the characterization of the network as a whole. In this work, we undertake this study by embedding QKD protocols on complex networks, which correctly model the existing fiber networks. We focus on networks with trusted nodes and on continuous-variable (CV) schemes, which have much higher key rates than their discrete-variable (DV) counterparts. In the effective CV network, however, many of the unique properties of complex networks, such as small-worldness and the presence of hubs, are lost due to the fast decay of the key rate with physical distance for CV systems. These properties can be restored when considering a hybrid network consisting of both CV and DV protocols, achieving at the same time high average rate and inter-connectivity. Our work opens the path to the study of QKD complex networks in existing infrastructures.
△ Less
Submitted 3 April, 2025;
originally announced April 2025.
-
Pericoronary adipose tissue attenuation as a predictor of functional severity of coronary stenosis
Authors:
Marta Pillitteri,
Guido Nannini,
Simone Saitta,
Luca Mariani,
Riccardo Maragna,
Andrea Baggiano,
Gianluca Pontone,
Alberto Redaelli
Abstract:
Objective: This study aims to evaluate the functional significance of coronary stenosis by analyzing low-level radiomic features of the pericoronary adipose tissue (PCAT) surrounding the lesions, which are indicative of its inflammation status. Methods: A dataset of 72 patients who underwent coronary computed tomography angiography (CCTA) was analyzed, with 3D segmentation and computational fluid…
▽ More
Objective: This study aims to evaluate the functional significance of coronary stenosis by analyzing low-level radiomic features of the pericoronary adipose tissue (PCAT) surrounding the lesions, which are indicative of its inflammation status. Methods: A dataset of 72 patients who underwent coronary computed tomography angiography (CCTA) was analyzed, with 3D segmentation and computational fluid dynamics (CFD) simulations from a prior study. Centerlines of the main epicardial branches were automatically extracted, and lesions identified using Gaussian kernel regression to estimate healthy branch caliber. PCAT features were computed per vessel following guideline recommendations and per lesion within a region extending radially for two vessel radii. Features like fat volume and mean attenuation (FAI) were analyzed for their relationship with CFD-derived hemodynamic biomarkers, such as fractional flow reserve (FFR) and wall shear stress (WSS). These features also informed a machine learning (ML) model for classifying potentially ischemic lesions. Results: PCAT exhibited, on average, higher attenuation in the presence of hemodynamically significant lesions (i.e., FFR < 0.80), although this difference was of limited statistical significance. The ML classifier, trained on PCAT features, successfully distinguished potentially ischemic lesions, yielding average accuracy of 0.84. Conclusion: PCAT attenuation is correlated with the functional status of coronary stenosis and can be used to inform ML models for predicting potential ischemia. Significance: PCAT features, readily available from CCTA, can be used to predict the hemodynamic characteristics of a lesion without the need for an invasive FFR examination.
△ Less
Submitted 19 February, 2025;
originally announced February 2025.
-
An automated and time efficient framework for simulation of coronary blood flow under steady and pulsatile conditions
Authors:
Guido Nannini,
Simone Saitta,
Luca Mariani,
Riccardo Maragna,
Andrea Baggiano,
Saima Mushtaq,
Gianluca Pontone,
Alberto Redaelli
Abstract:
Fractional flow reserve (FFR) is the gold standard for diagnosing coronary artery disease (CAD). FFRCT uses computational fluid dynamics (CFD) to evaluate FFR non-invasively by simulating coronary flow in geometries reconstructed from computed tomography (CT). However, it faces challenges related to the cost of computing and uncertainties in defining patient-specific boundary conditions (BCs). We…
▽ More
Fractional flow reserve (FFR) is the gold standard for diagnosing coronary artery disease (CAD). FFRCT uses computational fluid dynamics (CFD) to evaluate FFR non-invasively by simulating coronary flow in geometries reconstructed from computed tomography (CT). However, it faces challenges related to the cost of computing and uncertainties in defining patient-specific boundary conditions (BCs). We investigated using time-averaged steady BCs instead of pulsatile ones to reduce computational time and deployed a self-adjusting method for tuning BCs to patient clinical data. 133 coronary arteries were reconstructed from CT images of CAD patients. For each vessel, invasive FFR was measured. Steady BCs for CFD were defined in two steps: i) rest BCs were extrapolated from clinical and image-derived data; ii) hyperemic BCs were computed from resting conditions. Flow rate was iteratively adjusted during the simulation until patient aortic pressure was matched. Pulsatile BCs were defined using the convergence values of steady BCs. Lesion-specific hemodynamic indexes were computed and compared between groups of patients indicated for surgery and those not. The whole pipeline was implemented as a straightforward, fully automated process. Steady and pulsatile FFRCT showed a strong correlation (r=0.988) and correlated with invasive FFR (r=0.797). The per-point difference between the pressure and FFRCT field predicted by the two methods was below 0.01 and 0.02, respectively. Both approaches exhibited good diagnostic performance: accuracy was 0.860 and 0.864, with AUCs of 0.923 and 0.912, for steady and pulsatile cases, respectively. Computational time for steady BCs CFD was approximately 30-fold lower than for the pulsatile case. This work demonstrates the feasibility of using steady BCs CFD for computing FFRCT in coronary arteries and its performance in a fully automated pipeline.
△ Less
Submitted 29 August, 2024;
originally announced August 2024.