-
Design and Beam Test Results for the 2D Projective sPHENIX Electromagnetic Calorimeter Prototype
Authors:
C. A. Aidala,
S. Altaf,
R. Belmont,
S. Boose,
D. Cacace,
M. Connors,
E. Desmond,
J. Frantz,
E. A. Gamez,
N. Grau,
J. S. Haggerty,
A. Hodges,
J. Huang,
Y. Kim,
M. D. Lenz,
W. Lenz,
N. A. Lewis,
E. J. Mannel,
J. D. Osborn,
D. V. Perepelitsa,
M. Phipps,
R. Pisani,
S. Polizzo,
A. Pun,
M. L. Purschke
, et al. (13 additional authors not shown)
Abstract:
sPHENIX is a new experiment under construction for the Relativistic Heavy Ion Collider at Brookhaven National Laboratory which will study the quark-gluon plasma to further the understanding of QCD matter and interactions. A prototype of the sPHENIX electromagnetic calorimeter (EMCal) was tested at the Fermilab Test Beam Facility in Spring 2018 as experiment T-1044. The EMCal prototype corresponds…
▽ More
sPHENIX is a new experiment under construction for the Relativistic Heavy Ion Collider at Brookhaven National Laboratory which will study the quark-gluon plasma to further the understanding of QCD matter and interactions. A prototype of the sPHENIX electromagnetic calorimeter (EMCal) was tested at the Fermilab Test Beam Facility in Spring 2018 as experiment T-1044. The EMCal prototype corresponds to a solid angle of $ Δη\times Δφ= 0.2 \times 0.2$ centered at pseudo-rapidity $η= 1$. The prototype consists of scintillating fibers embedded in a mix of tungsten powder and epoxy. The fibers project back approximately to the center of the sPHENIX detector, giving 2D projectivity. The energy response of the EMCal prototype was studied as a function of position and input energy. The energy resolution of the EMCal prototype was obtained after applying a position dependent energy correction and a beam profile correction. Two separate position dependent corrections were considered. The EMCal energy resolution was found to be $σ(E)/\langle E\rangle = 3.5(0.1) \oplus 13.3(0.2)/\sqrt{E}$ based on the hodoscope position dependent correction, and $σ(E)/\langle E\rangle = 3.0(0.1) \oplus 15.4(0.3)/\sqrt{E}$ based on the cluster position dependent correction. These energy resolution results meet the requirements of the sPHENIX physics program.
△ Less
Submitted 15 March, 2021; v1 submitted 27 March, 2020;
originally announced March 2020.
-
A Comparison of the Effects of Neutron and Gamma Radiation in Silicon Photomultipliers
Authors:
B. Biró,
G. David,
A. Fenyvesi,
J. S. Haggerty,
J. Kierstead,
E. J. Mannel,
T. Majoros,
J. Molnar,
F. Nagy,
S. Stoll,
B. Ujvari,
C. L. Woody
Abstract:
The effects of radiation damage in silicon photomultipliers (SiPMs) from gamma rays have been measured and compared with the damage produced by neutrons. Several types of MPPCs from Hamamatsu were exposed to gamma rays and neutrons at the Solid State Gamma Ray Irradiation Facility (SSGRIF) at Brookhaven National Lab and the Institute for Nuclear Research (Atomki) in Debrecen, Hungary. The gamma ra…
▽ More
The effects of radiation damage in silicon photomultipliers (SiPMs) from gamma rays have been measured and compared with the damage produced by neutrons. Several types of MPPCs from Hamamatsu were exposed to gamma rays and neutrons at the Solid State Gamma Ray Irradiation Facility (SSGRIF) at Brookhaven National Lab and the Institute for Nuclear Research (Atomki) in Debrecen, Hungary. The gamma ray exposures ranged from 1 krad to 1 Mrad and the neutron exposures ranged from 10$^8$ n/cm$^2$ to 10$^{12}$ n/cm$^2$. The main effect of gamma ray damage is an increase in the noise and leakage current in the irradiated devices, similar to what is seen from neutron damage, but the level of damage is considerably less at comparable high levels of exposure. In addition, the damage from gamma rays saturates after a few hundred krad, while the damage from neutrons shows no sign of saturation, suggestive of different damage mechanisms in the two cases. The change in optical absorption in the window material of the SiPMs due to radiation was also measured. This study was carried out in order to evaluate the use of SiPMs for particle physics applications with moderate levels of radiation exposures.
△ Less
Submitted 7 April, 2019; v1 submitted 12 September, 2018;
originally announced September 2018.
-
Design and Beam Test Results for the sPHENIX Electromagnetic and Hadronic Calorimeter Prototypes
Authors:
C. A. Aidala,
V. Bailey,
S. Beckman,
R. Belmont,
C. Biggs,
J. Blackburn,
S. Boose,
M. Chiu,
M. Connors,
E. Desmond,
A. Franz,
J. S. Haggerty,
X. He,
M. M. Higdon,
J. Huang,
K. Kauder,
E. Kistenev,
J. LaBounty,
J. G. Lajoie,
M. Lenz,
W. Lenz,
S. Li,
V. R. Loggins,
E. J. Mannel,
T. Majoros
, et al. (25 additional authors not shown)
Abstract:
The super Pioneering High Energy Nuclear Interaction eXperiment (sPHENIX) at the Relativistic Heavy Ion Collider (RHIC) will perform high precision measurements of jets and heavy flavor observables for a wide selection of nuclear collision systems, elucidating the microscopic nature of strongly interacting matter ranging from nucleons to the strongly coupled quark-gluon plasma. A prototype of the…
▽ More
The super Pioneering High Energy Nuclear Interaction eXperiment (sPHENIX) at the Relativistic Heavy Ion Collider (RHIC) will perform high precision measurements of jets and heavy flavor observables for a wide selection of nuclear collision systems, elucidating the microscopic nature of strongly interacting matter ranging from nucleons to the strongly coupled quark-gluon plasma. A prototype of the sPHENIX calorimeter system was tested at the Fermilab Test Beam Facility as experiment T-1044 in the spring of 2016. The electromagnetic calorimeter (EMCal) prototype is composed of scintillating fibers embedded in a mixture of tungsten powder and epoxy. The hadronic calorimeter (HCal) prototype is composed of tilted steel plates alternating with plastic scintillator. Results of the test beam reveal the energy resolution for electrons in the EMCal is $2.8\%\oplus~15.5\%/\sqrt{E}$ and the energy resolution for hadrons in the combined EMCal plus HCal system is $13.5\%\oplus 64.9\%/\sqrt{E}$. These results demonstrate that the performance of the proposed calorimeter system satisfies the sPHENIX specifications.
△ Less
Submitted 16 December, 2018; v1 submitted 5 April, 2017;
originally announced April 2017.