Laser locking to the 199Hg clock transition with 5.4x10^(-15)/sqrt(tau) fractional frequency instability
Authors:
J. J. McFerran,
D. V. Magalhaes,
C. Mandache,
J. Millo,
W. Zhang,
Y. Le Coq,
G. Santarelli,
S. Bize
Abstract:
With Hg atoms confined in an optical lattice trap in the Lamb-Dicke regime, we obtain a spectral line at 265.6 nm in which the full-width at half-maximum is <15Hz. Here we lock an ultrastable laser to this ultranarrow clock transition and achieve a fractional frequency stability of 5.4x10^(-15)/sqrt(tau) for tau<=400s. The highly stable laser light used for the atom probing is derived from a 1062.…
▽ More
With Hg atoms confined in an optical lattice trap in the Lamb-Dicke regime, we obtain a spectral line at 265.6 nm in which the full-width at half-maximum is <15Hz. Here we lock an ultrastable laser to this ultranarrow clock transition and achieve a fractional frequency stability of 5.4x10^(-15)/sqrt(tau) for tau<=400s. The highly stable laser light used for the atom probing is derived from a 1062.6 nm fiber laser locked to an ultrastable optical cavity that exhibits a mean drift rate of -6.0x10^(-17) s^(-1) (or -16.9 mHz.s^(-1) at 282 THz) over a five month period. A comparison between two such lasers locked to independent optical cavities shows a flicker noise limited fractional frequency instability of 4x10^(-16) per cavity.
△ Less
Submitted 2 July, 2012; v1 submitted 18 May, 2012;
originally announced May 2012.
-
An Ultra-Stable Referenced Interrogation System in the Deep Ultraviolet for a Mercury Optical Lattice Clock
Authors:
S. T. Dawkins,
R. Chicireanu,
M. Petersen,
J. Millo,
D. V. Magalhães,
C. Mandache,
Y. Le Coq,
S. Bize
Abstract:
We have developed an ultra-stable source in the deep ultraviolet, suitable to fulfill the interrogation requirements of a future fully-operational lattice clock based on neutral mercury. At the core of the system is a Fabry-Pérot cavity which is highly impervious to temperature and vibrational perturbations. The mirror substrate is made of fused silica in order to exploit the comparatively low the…
▽ More
We have developed an ultra-stable source in the deep ultraviolet, suitable to fulfill the interrogation requirements of a future fully-operational lattice clock based on neutral mercury. At the core of the system is a Fabry-Pérot cavity which is highly impervious to temperature and vibrational perturbations. The mirror substrate is made of fused silica in order to exploit the comparatively low thermal noise limits associated with this material. By stabilizing the frequency of a 1062.6 nm Yb-doped fiber laser to the cavity, and including an additional link to LNE-SYRTE's fountain primary frequency standards via an optical frequency comb, we produce a signal which is both stable at the 1E-15 level in fractional terms and referenced to primary frequency standards. The signal is subsequently amplified and frequency-doubled twice to produce several milliwatts of interrogation signal at 265.6 nm in the deep ultraviolet.
△ Less
Submitted 22 March, 2010;
originally announced March 2010.
-
Ultrastable lasers based on vibration insensitive cavities
Authors:
J. Millo,
D. V. Magalhaes,
C. Mandache,
Y. Le Coq,
E. M. L. English,
P. G. Westergaard,
J. Lodewyck,
S. Bize,
P. Lemonde,
G. Santarelli
Abstract:
We present two ultra-stable lasers based on two vibration insensitive cavity designs, one with vertical optical axis geometry, the other horizontal. Ultra-stable cavities are constructed with fused silica mirror substrates, shown to decrease the thermal noise limit, in order to improve the frequency stability over previous designs. Vibration sensitivity components measured are equal to or better…
▽ More
We present two ultra-stable lasers based on two vibration insensitive cavity designs, one with vertical optical axis geometry, the other horizontal. Ultra-stable cavities are constructed with fused silica mirror substrates, shown to decrease the thermal noise limit, in order to improve the frequency stability over previous designs. Vibration sensitivity components measured are equal to or better than 1.5e-11 per m.s^-2 for each spatial direction, which shows significant improvement over previous studies. We have tested the very low dependence on the position of the cavity support points, in order to establish that our designs eliminate the need for fine tuning to achieve extremely low vibration sensitivity. Relative frequency measurements show that at least one of the stabilized lasers has a stability better than 5.6e-16 at 1 second, which is the best result obtained for this length of cavity.
△ Less
Submitted 4 May, 2009; v1 submitted 29 January, 2009;
originally announced January 2009.
-
Doppler-free spectroscopy of the 1S0-3P0 optical clock transition in laser-cooled fermionic isotopes of neutral mercury
Authors:
M. Petersen,
R. Chicireanu,
S. T. Dawkins,
D. V. Magalhães,
C. Mandache,
Y. Lecoq,
A. Clairon,
S. Bize
Abstract:
We have performed for the first time direct laser spectroscopy of the 1S0-3P0 optical clock transition at 265.6 nm in fermionic isotopes of neutral mercury laser-cooled in a magneto-optical trap. Spectroscopy is performed by measuring the depletion of the magneto-optical trap induced by the excitation of the long-lived 3P0 state by a probe at 265.6 nm. Measurements resolve the Doppler-free recoi…
▽ More
We have performed for the first time direct laser spectroscopy of the 1S0-3P0 optical clock transition at 265.6 nm in fermionic isotopes of neutral mercury laser-cooled in a magneto-optical trap. Spectroscopy is performed by measuring the depletion of the magneto-optical trap induced by the excitation of the long-lived 3P0 state by a probe at 265.6 nm. Measurements resolve the Doppler-free recoil doublet allowing for a determination of the transition frequency to an uncer- tainty well below the Doppler-broadened linewidth. We have performed absolute measurement of the frequency with respect to an ultra-stable reference monitored by LNE-SYRTE fountain pri- mary frequency standards using a femtosecond laser frequency comb. The measured frequency is 1128575290808 +/- 5.6 kHz in 199Hg and 1128569561140 +/- 5.3 kHz in 201Hg, more than 4 orders of magnitude better than previous indirect determinations. Owing to a low sensitivity to blackbody radiation, mercury is a promising candidate for reaching the ultimate performance of optical lattice clocks.
△ Less
Submitted 22 July, 2008;
originally announced July 2008.
-
A Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Authors:
H. Marion,
F. Pereira Dos Santos,
M. Abgrall,
S. Zhang,
Y. Sortais,
S. Bize,
I. Maksimovic,
D. Calonico,
J. Gruenert,
C. Mandache,
P. Lemonde,
G. Santarelli,
Ph. Laurent,
A. Clairon,
C. Salomon
Abstract:
Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser cooled 133Cs and 87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a stringent upper bound to a possible fractional time variation of the ratio between the two frequencies : (d/dt)ln(nu_Rb/nu_Cs)=(0.2 +/- 7.0)*10^{-16} yr^{-1} (1 sigma…
▽ More
Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser cooled 133Cs and 87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a stringent upper bound to a possible fractional time variation of the ratio between the two frequencies : (d/dt)ln(nu_Rb/nu_Cs)=(0.2 +/- 7.0)*10^{-16} yr^{-1} (1 sigma uncertainty). The same limit applies to a possible variation of the quantity (mu_Rb/mu_Cs)*alpha^{-0.44}, which involves the ratio of nuclear magnetic moments and the fine structure constant.
△ Less
Submitted 31 December, 2002;
originally announced December 2002.
-
133Cs87Rb Laser Cooled Dual Fountain
Authors:
D. Calonico,
Y. Sortais,
S. Bize,
H. Marion,
C. Mandache,
C. Salomon,
G. Santarelli,
A. Clairon
Abstract:
At BNM-SYRTE laboratories in Paris two 133Cs fountains and a 87Rb one have been already demonstrated. This paper illustrates the construction of a 87Rb and Cs dual fountain realized within the same structure to work simultaneously. Up to now only the Cs part is under operation but Rb part, already completed, will be soon operational. The experiment has been projected to improve present fountain…
▽ More
At BNM-SYRTE laboratories in Paris two 133Cs fountains and a 87Rb one have been already demonstrated. This paper illustrates the construction of a 87Rb and Cs dual fountain realized within the same structure to work simultaneously. Up to now only the Cs part is under operation but Rb part, already completed, will be soon operational. The experiment has been projected to improve present fountain frequency standards and to perform a more precise laboratory test (at 10E-16 level) on a possible time variation of the fine structure constant alpha, as recent cosmological evidences strongly motivates.
△ Less
Submitted 10 December, 2002;
originally announced December 2002.