-
Design and Performance of the Spin Asymmetries of the Nucleon Experiment
Authors:
J. D. Maxwell,
W. R. Armstrong,
S. Choi,
M. K. Jones,
H. Kang,
A. Liyanage,
Z. -E. Meziani,
J. Mulholland,
L. Ndukum,
O. A. Rondon,
A. Ahmidouch,
I. Albayrak,
A. Asaturyan,
O. Ates,
H. Baghdasaryan,
W. Boeglin,
P. Bosted,
E. Brash,
J. Brock,
C. Butuceanu,
M. Bychkov,
C. Carlin,
P. Carter,
C. Chen,
J. -P. Chen
, et al. (80 additional authors not shown)
Abstract:
The Spin Asymmetries of the Nucleon Experiment (SANE) performed inclusive, double-polarized electron scattering measurements of the proton at the Continuous Electron Beam Accelerator Facility at Jefferson Lab. A novel detector array observed scattered electrons of four-momentum transfer $2.5 < Q^2< 6.5$ GeV$^2$ and Bjorken scaling $0.3<x<0.8$ from initial beam energies of 4.7 and 5.9 GeV. Employin…
▽ More
The Spin Asymmetries of the Nucleon Experiment (SANE) performed inclusive, double-polarized electron scattering measurements of the proton at the Continuous Electron Beam Accelerator Facility at Jefferson Lab. A novel detector array observed scattered electrons of four-momentum transfer $2.5 < Q^2< 6.5$ GeV$^2$ and Bjorken scaling $0.3<x<0.8$ from initial beam energies of 4.7 and 5.9 GeV. Employing a polarized proton target whose magnetic field direction could be rotated with respect to the incident electron beam, both parallel and near perpendicular spin asymmetries were measured, allowing model-independent access to transverse polarization observables $A_1$, $A_2$, $g_1$, $g_2$ and moment $d_2$ of the proton. This document summarizes the operation and performance of the polarized target, polarized electron beam, and novel detector systems used during the course of the experiment, and describes analysis techniques utilized to access the physics observables of interest.
△ Less
Submitted 21 December, 2017; v1 submitted 22 November, 2017;
originally announced November 2017.
-
Hall A Annual Report 2012
Authors:
S. Riordan,
C. Keppel,
K. Aniol,
J. Annand,
J. Arrington,
T. Averett,
C. Ayerbe Gayoso,
E. Brash,
G. D. Cates,
J. -P. Chen,
E. Chudakov,
D. Flay,
G. B. Franklin,
M. Friedman,
O. Glamazdin,
J. Gomez,
C. Hanretty,
J. -O. Hansen,
C. Hyde,
M. K. Jones,
I. Korover,
J. J. LeRose,
R. A. Lindgren,
N. Liyanage,
E. Long
, et al. (24 additional authors not shown)
Abstract:
Report over the experimental activities in Hall A at Thomas Jefferson National Accelerator Facility.
Report over the experimental activities in Hall A at Thomas Jefferson National Accelerator Facility.
△ Less
Submitted 18 February, 2013;
originally announced February 2013.
-
Comparison of Modeled and Measured Performance of a GSO Crystal as Gamma Detector
Authors:
D. S. Parno,
M. Friend,
V. Mamyan,
F. Benmokhtar,
A. Camsonne,
G. B. Franklin,
K. Paschke,
B. Quinn
Abstract:
We have modeled, tested, and installed a large, cerium-activated Gd2SiO5 crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up to 40 MeV, and photons from a continuous Compton backscattering spectrum up to 200 MeV. Our GEANT4 simulations, developed to determine the analyzing power of the…
▽ More
We have modeled, tested, and installed a large, cerium-activated Gd2SiO5 crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up to 40 MeV, and photons from a continuous Compton backscattering spectrum up to 200 MeV. Our GEANT4 simulations, developed to determine the analyzing power of the Compton polarimeter in Hall A of Jefferson Lab, reproduce the measured spectra well.
△ Less
Submitted 24 May, 2013; v1 submitted 15 November, 2012;
originally announced November 2012.
-
Upgraded photon calorimeter with integrating readout for Hall A Compton Polarimeter at Jefferson Lab
Authors:
M. Friend,
D. Parno,
F. Benmokhtar,
A. Camsonne,
M. Dalton,
G. B. Franklin,
V. Mamyan,
R. Michaels,
S. Nanda,
V. Nelyubin,
K. Paschke,
B. Quinn,
A. Rakhman,
P. Souder,
A. Tobias
Abstract:
The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped GSO crysta…
▽ More
The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped GSO crystal, which has a bright output and fast response, and works well for measurements using the new integrating method at electron beam energies from 1 to 6 GeV.
△ Less
Submitted 24 August, 2011; v1 submitted 15 August, 2011;
originally announced August 2011.
-
An Electromagnetic Calorimeter for the JLab Real Compton Scattering Experiment
Authors:
D. J. Hamilton,
A. Shahinyan,
B. Wojtsekhowski,
J. R. M. Annand,
T. -H. Chang,
E. Chudakov,
A. Danagoulian,
P. Degtyarenko,
K. Egiyan,
R. Gilman,
V. Gorbenko,
J. Hines,
E. Hovhannisyan,
C. E. Hyde-Wright,
C. W. de Jager,
A. Ketikyan,
V. H. Mamyan,
R. Michaels,
A. M. Nathan,
V. Nelyubin,
I. Rachek,
M. Roedelbrom,
A. Petrosyan,
R. Pomatsalyuk,
V. Popov
, et al. (4 additional authors not shown)
Abstract:
A lead-glass hodoscope calorimeter that was constructed for use in the Jefferson Lab Real Compton Scattering experiment is described. The detector provides a measurement of the coordinates and the energy of scattered photons in the GeV energy range with resolutions of 5 mm and 6%/\sqrt(Eγ [GeV]). Features of both the detector design and its performance in the high luminosity environment during the…
▽ More
A lead-glass hodoscope calorimeter that was constructed for use in the Jefferson Lab Real Compton Scattering experiment is described. The detector provides a measurement of the coordinates and the energy of scattered photons in the GeV energy range with resolutions of 5 mm and 6%/\sqrt(Eγ [GeV]). Features of both the detector design and its performance in the high luminosity environment during the experiment are presented.
△ Less
Submitted 25 September, 2015; v1 submitted 14 April, 2007;
originally announced April 2007.