-
Research of interaction processes of fast and thermal neutrons with solution of methyl orange organic dye
Authors:
Sergey P. Gokov,
Yuri G. Kazarinov,
Sergiy A. Kalenik,
Valentin Y. Kasilov,
Tetiana V. Malykhina,
Yegor V. Rudychev,
Vitaliy V. Tsiatsko
Abstract:
The processes of neutron fluxes interaction with an aqueous solution of methyl orange organic dye have been investigated. The work was carried out on a LINAC LUE-300 at NSC KIPT. A set of tungsten plates was used as a neutron-generating target. The electron energy was 15 MeV, the average current was 20 mkA. The samples were located behind the lead shield and without it, with and without a moderato…
▽ More
The processes of neutron fluxes interaction with an aqueous solution of methyl orange organic dye have been investigated. The work was carried out on a LINAC LUE-300 at NSC KIPT. A set of tungsten plates was used as a neutron-generating target. The electron energy was 15 MeV, the average current was 20 mkA. The samples were located behind the lead shield and without it, with and without a moderator. Using the Geant4 toolkit for this experiment, neutron fluxes and their energy spectra were calculated at the location of experimental samples without a moderator and with a moderator of different thickness (1-5 cm). An analysis of the experimental results showed that when objects without lead shielding and without a moderator are irradiated, the dye molecules are completely destroyed. In the presence of lead protection, 10% destruction of the dye molecules was observed. When a five-centimeter polyethylene moderator was installed behind the lead shield, the destruction of dye molecules without boric acid on thermal neutrons was practically not observed. When the fluxes of thermal and epithermal neutrons interacted with a dye solution containing 4% boric acid, 30% destruction of dye molecules was observed due to the exothermic reaction 10B (n, a). The research has shown that solutions of organic dyes are a good material for creating detectors for recording fluxes of thermal and epithermal neutrons. Such detectors can be used for radioecological monitoring of the environment, in nuclear power engineering and nuclear medicine, and in the field of neutron capture therapy research in particular.
△ Less
Submitted 4 January, 2022;
originally announced January 2022.
-
Effect of energy leakage on the energy resolution of E.M. sampling calorimeters
Authors:
O. P. Gavrishchuk,
V. E. Kovtun,
T. V. Malykhina
Abstract:
The electromagnetic sampling calorimeters of the SPD experiment (NICA collider) are being investigated by Monte Carlo method. The simulation is used to study in detail the influence of energy leakages from the module on its energy resolution. The values of the stochastic and constant terms are obtained for the SPD calorimeter prototypes.
The electromagnetic sampling calorimeters of the SPD experiment (NICA collider) are being investigated by Monte Carlo method. The simulation is used to study in detail the influence of energy leakages from the module on its energy resolution. The values of the stochastic and constant terms are obtained for the SPD calorimeter prototypes.
△ Less
Submitted 22 December, 2021;
originally announced December 2021.
-
Modeling and experimental research of the processes of radiation damage formation in the interaction of gamma quanta flows and relativistic electron beams with solution of organic dyes
Authors:
S. P. Gokov,
Yu. G. Kazarinov,
S. A. Kalenik,
V. Y. Kasilov,
V. V. Kantemirov,
O. O. Mazilov,
T. V. Malykhina,
V. V. Tsiatsko,
E. V. Tsiatsko
Abstract:
The processes of interaction of an aqueous solution of methylene blue (MB) organic dye ($C_{16}H_{18}N_{3}SCl$ ) with gamma quanta and electrons have been investigated. A model has been developed, and the passage of electrons with an energy of 15 MeV through tungsten layers with a thickness of 1...8 mm has been simulated. A number of experiments were carried out on the basis of the simulation resu…
▽ More
The processes of interaction of an aqueous solution of methylene blue (MB) organic dye ($C_{16}H_{18}N_{3}SCl$ ) with gamma quanta and electrons have been investigated. A model has been developed, and the passage of electrons with an energy of 15 MeV through tungsten layers with a thickness of 1...8 mm has been simulated. A number of experiments were carried out on the basis of the simulation results. Analysis of the calculated and experimental data showed that one incident electron destroys 4 times more dye molecules than one incident gamma-quantum.
△ Less
Submitted 21 December, 2021;
originally announced December 2021.
-
Simulation of a high-energy electron beam transmission through titanium and Kapton$^\circledR$ thin films
Authors:
Tetiana Malykhina,
Stepan Karpus,
Oleg Shopen,
Valerii Prystupa
Abstract:
The results of computer simulation of the high-energy electrons passage through thin layers of titanium (Ti) and polyimide Kapton$^\circledR$ in the energy range from 3 to 20 MeV are presented. Simulation is carried out using the Geant4 toolkit. The thickness of the Ti foil in the model experiment is 50 microns, the thickness of the Kapton$^\circledR$ film is 110 microns. The purpose of the calcul…
▽ More
The results of computer simulation of the high-energy electrons passage through thin layers of titanium (Ti) and polyimide Kapton$^\circledR$ in the energy range from 3 to 20 MeV are presented. Simulation is carried out using the Geant4 toolkit. The thickness of the Ti foil in the model experiment is 50 microns, the thickness of the Kapton$^\circledR$ film is 110 microns. The purpose of the calculations is to reveal the possibility of using the Kapton$^\circledR$ film in the output devices of linear electron accelerators. It was necessary to calculate the probable values of the energy absorbed in a Kapton$^\circledR$ film and in a Ti foil for each value of primary electrons energy. Another important characteristic is the divergence radius of the electron beam at a predetermined distance from the film, or the electron scattering angle. As a result of calculations, the energy spectra of bremsstrahlung gamma-quanta, formed during the passage of electrons through the materials of the films, are obtained. The most probable values of the energy absorbed in the Ti foil and in the Kapton$^\circledR$ film are calculated. The scattering radii of an electron beam for the Kapton$^\circledR$ film and also for the Ti foil at a distance of 20 cm are estimated. It is shown that the ratio of the total amount of bremsstrahlung gamma quanta in the case of use the Kapton$^\circledR$ film is approximately 0.56 of the total amount of bremsstrahlung gamma quanta when using the Ti foil. The analysis of the calculated data showed that the use of Kapton$^\circledR$ as a material for the manufacture of output devices for high-energy electron beams is more preferable in comparison to Ti films. The use of Kapton$^\circledR$ instead of Ti makes it possible to significantly reduce the background of the generated bremsstrahlung gamma quanta and reduce the scattering radius of the electron beam.
△ Less
Submitted 16 December, 2021; v1 submitted 14 December, 2021;
originally announced December 2021.
-
Geant4 modeling of the bremsstrahlung converter optimal thickness for studying the radiation damage processes in organic dyes solutions
Authors:
Tetiana Malykhina,
Vladimir Kovtun,
Valentin Kasilov,
Sergey Gokov
Abstract:
This work is dedicated to computer modeling of the parameters of a tungsten converter for studying the processes of radiation damage during the interaction of ionizing radiation with solutions of organic dyes. Simulation was carried out in order to determine the optimal thickness of the converter under predetermined experimental conditions. Experimental conditions include: energies and type of pri…
▽ More
This work is dedicated to computer modeling of the parameters of a tungsten converter for studying the processes of radiation damage during the interaction of ionizing radiation with solutions of organic dyes. Simulation was carried out in order to determine the optimal thickness of the converter under predetermined experimental conditions. Experimental conditions include: energies and type of primary particles, radiation intensity, target dimensions, relative position of the radiation source and target. Experimental studies of the processes of radiation damage occurring in solutions of organic dyes are planned to be carried out using the linear electron. The tungsten converter is used to generate a flux of bremsstrahlung gamma rays. One modeling problem is determination of the converter thickness at which the flux of bremsstrahlung gamma will be maximal in front of the target. At the same time, the flow of electrons and positrons in front of the target should be as low as possible. Another important task of the work is to identify the possibility of determining the relative amount of radiation damage in the target material by the Geant4 modeling method. Computational experiments were carried out for various values of the converter thickness - from 0 mm (converter is absent) to 8 mm with a step of 1 mm. The developed program operates in a multithreaded mode. The G4EmStandardPhysics_option3 model of the PhysicsList was used in the calculations. A detailed analysis of the obtained data has been performed. As a result of the data analysis, the optimal value of the tungsten converter thickness was obtained.
△ Less
Submitted 14 December, 2021;
originally announced December 2021.
-
Simulation studies of the Moliere radius for em calorimeter materials
Authors:
O. P. Gavrishchuk,
V. E. Kovtun,
T. V. Malykhina
Abstract:
The Monte Carlo calculations of the Moliere radius (RM) for some homogeneous and heterogeneous media used in electromagnetic calorimetry in the energy range from 50 MeV to 10 GeV are presented in detail. The obtained results, the uncertainties in determining RM, estimations of the absorbed energy, methods for approximating the absorbed energy, and the accuracy of the results are discussed as well.…
▽ More
The Monte Carlo calculations of the Moliere radius (RM) for some homogeneous and heterogeneous media used in electromagnetic calorimetry in the energy range from 50 MeV to 10 GeV are presented in detail. The obtained results, the uncertainties in determining RM, estimations of the absorbed energy, methods for approximating the absorbed energy, and the accuracy of the results are discussed as well. Some RM are shown for calorimeter prototypes of the Spin Physics Detector experiment (SPD). A one-parameter function of the Moliere radius dependence on the absorber-scintillator thickness ratio is obtained.
△ Less
Submitted 14 December, 2021;
originally announced December 2021.
-
Conceptual design of the Spin Physics Detector
Authors:
V. M. Abazov,
V. Abramov,
L. G. Afanasyev,
R. R. Akhunzyanov,
A. V. Akindinov,
N. Akopov,
I. G. Alekseev,
A. M. Aleshko,
V. Yu. Alexakhin,
G. D. Alexeev,
M. Alexeev,
A. Amoroso,
I. V. Anikin,
V. F. Andreev,
V. A. Anosov,
A. B. Arbuzov,
N. I. Azorskiy,
A. A. Baldin,
V. V. Balandina,
E. G. Baldina,
M. Yu. Barabanov,
S. G. Barsov,
V. A. Baskov,
A. N. Beloborodov,
I. N. Belov
, et al. (270 additional authors not shown)
Abstract:
The Spin Physics Detector, a universal facility for studying the nucleon spin structure and other spin-related phenomena with polarized proton and deuteron beams, is proposed to be placed in one of the two interaction points of the NICA collider that is under construction at the Joint Institute for Nuclear Research (Dubna, Russia). At the heart of the project there is huge experience with polarize…
▽ More
The Spin Physics Detector, a universal facility for studying the nucleon spin structure and other spin-related phenomena with polarized proton and deuteron beams, is proposed to be placed in one of the two interaction points of the NICA collider that is under construction at the Joint Institute for Nuclear Research (Dubna, Russia). At the heart of the project there is huge experience with polarized beams at JINR.
The main objective of the proposed experiment is the comprehensive study of the unpolarized and polarized gluon content of the nucleon. Spin measurements at the Spin Physics Detector at the NICA collider have bright perspectives to make a unique contribution and challenge our understanding of the spin structure of the nucleon. In this document the Conceptual Design of the Spin Physics Detector is presented.
△ Less
Submitted 2 February, 2022; v1 submitted 31 January, 2021;
originally announced February 2021.
-
Geant4 modeling of energy spectrum of fast neutrons source for the development of research technique of heavy scintillators
Authors:
Tetiana Malykhina,
Viktoriia Lisovska,
Valentina Shpagina,
Ruslan Timchenko
Abstract:
The proposed work demonstrates the results of creating and investigating the mathematical model of the source of fast neutrons. The model carrier is a computer program developed in the C++ programming language in the Linux operating system environment, using the Geant4 toolkit. All necessary classes describing low-energy models were used for the simulation of the passage of neutrons through materi…
▽ More
The proposed work demonstrates the results of creating and investigating the mathematical model of the source of fast neutrons. The model carrier is a computer program developed in the C++ programming language in the Linux operating system environment, using the Geant4 toolkit. All necessary classes describing low-energy models were used for the simulation of the passage of neutrons through materials of detectors. Those take into account the elastic scattering, inelastic scattering, radiative capture and fission. Diagrams containing energy spectra of a source of fast neutrons modeled in two ways are presented in the paper. The analysis of the obtained energy spectra is carried out. The created model of 239PuBe neutron source can be used for the investigation of scintillation detectors Bi4Ge3O12, CdWO4, Gd2SiO5 and others, as well as studying their characteristics. Processes in heavy oxide scintillators substance during the registration of fast neutrons can be studied using the developed model. It is shown that for registration of the flow of neutrons from 239PuBe neutron source, using Bi4Ge3O12 or CdWO4 scintillators is more preferable. Results of the virtual nuclear physical experiments satisfy the published experimental data.
△ Less
Submitted 29 January, 2020;
originally announced January 2020.