-
On using the Microsoft Kinect$^{\rm TM}$ sensors to determine the lengths of the arm and leg bones of a human subject in motion
Authors:
M. J. Malinowski,
E. Matsinos
Abstract:
The present study is part of a broader programme, exploring the possibility of involving the Microsoft Kinect$^{\rm TM}$ sensor in the analysis of human motion. We examine the output obtained from the two available versions of this sensor in relation to the variability of the estimates of the lengths of eight bones belonging to the subject's extremities: of the humerus (upper arm), ulna (lower arm…
▽ More
The present study is part of a broader programme, exploring the possibility of involving the Microsoft Kinect$^{\rm TM}$ sensor in the analysis of human motion. We examine the output obtained from the two available versions of this sensor in relation to the variability of the estimates of the lengths of eight bones belonging to the subject's extremities: of the humerus (upper arm), ulna (lower arm, forearm), femur (upper leg), and tibia (lower leg, shank). Large systematic effects in the output of the two sensors have been observed.
△ Less
Submitted 2 May, 2015;
originally announced May 2015.
-
Comparative study of the two versions of the Microsoft Kinect$^{\rm TM}$ sensor in regard to the analysis of human motion
Authors:
M. J. Malinowski,
E. Matsinos
Abstract:
The present paper is part of a broader programme, exploring the possibility of involving the Microsoft Kinect$^{\rm TM}$ sensor in the analysis of human motion. In this study, the output obtained from the two available versions of this sensor is critically examined. We demonstrate that the two outputs differ in regard to the variation of the physical quantities involved in the modelling of the hum…
▽ More
The present paper is part of a broader programme, exploring the possibility of involving the Microsoft Kinect$^{\rm TM}$ sensor in the analysis of human motion. In this study, the output obtained from the two available versions of this sensor is critically examined. We demonstrate that the two outputs differ in regard to the variation of the physical quantities involved in the modelling of the human motion. As the original sensor has been found unsuitable for applications requiring high precision, the observed differences in the output of the two sensors call for the validation of the upgraded sensor on the basis of a marker-based system.
△ Less
Submitted 1 April, 2015;
originally announced April 2015.
-
On using the Microsoft Kinect$^{\rm TM}$ sensors in the analysis of human motion
Authors:
M. J. Malinowski,
E. Matsinos,
S. Roth
Abstract:
The present paper aims at providing the theoretical background required for investigating the use of the Microsoft Kinect$^{\rm TM}$ (`Kinect', for short) sensors (original and upgraded) in the analysis of human motion. Our methodology is developed in such a way that its application be easily adaptable to comparative studies of other systems used in capturing human-motion data. Our future plans in…
▽ More
The present paper aims at providing the theoretical background required for investigating the use of the Microsoft Kinect$^{\rm TM}$ (`Kinect', for short) sensors (original and upgraded) in the analysis of human motion. Our methodology is developed in such a way that its application be easily adaptable to comparative studies of other systems used in capturing human-motion data. Our future plans include the application of this methodology to two situations: first, in a comparative study of the performance of the two Kinect sensors; second, in pursuing their validation on the basis of comparisons with a marker-based system (MBS). One important feature in our approach is the transformation of the MBS output into Kinect-output format, thus enabling the analysis of the measurements, obtained from different systems, with the same software application, i.e., the one we use in the analysis of Kinect-captured data; one example of such a transformation, for one popular marker-placement scheme (`Plug-in Gait'), is detailed. We propose that the similarity of the output, obtained from the different systems, be assessed on the basis of the comparison of a number of waveforms, representing the variation within the gait cycle of quantities which are commonly used in the modelling of the human motion. The data acquisition may involve commercially-available treadmills and a number of velocity settings: for instance, walking-motion data may be acquired at $5$ km/h, running-motion data at $8$ and $11$ km/h. We recommend that particular attention be called to systematic effects associated with the subject's knee and lower leg, as well as to the ability of the Kinect sensors in reliably capturing the details in the asymmetry of the motion for the left and right parts of the human body. The previous versions of the study have been withdrawn due to the use of a non-representative database.
△ Less
Submitted 27 May, 2015; v1 submitted 4 December, 2014;
originally announced December 2014.