-
Implicit Gaussian process representation of vector fields over arbitrary latent manifolds
Authors:
Robert L. Peach,
Matteo Vinao-Carl,
Nir Grossman,
Michael David,
Emma Mallas,
David Sharp,
Paresh A. Malhotra,
Pierre Vandergheynst,
Adam Gosztolai
Abstract:
Gaussian processes (GPs) are popular nonparametric statistical models for learning unknown functions and quantifying the spatiotemporal uncertainty in data. Recent works have extended GPs to model scalar and vector quantities distributed over non-Euclidean domains, including smooth manifolds appearing in numerous fields such as computer vision, dynamical systems, and neuroscience. However, these a…
▽ More
Gaussian processes (GPs) are popular nonparametric statistical models for learning unknown functions and quantifying the spatiotemporal uncertainty in data. Recent works have extended GPs to model scalar and vector quantities distributed over non-Euclidean domains, including smooth manifolds appearing in numerous fields such as computer vision, dynamical systems, and neuroscience. However, these approaches assume that the manifold underlying the data is known, limiting their practical utility. We introduce RVGP, a generalisation of GPs for learning vector signals over latent Riemannian manifolds. Our method uses positional encoding with eigenfunctions of the connection Laplacian, associated with the tangent bundle, readily derived from common graph-based approximation of data. We demonstrate that RVGP possesses global regularity over the manifold, which allows it to super-resolve and inpaint vector fields while preserving singularities. Furthermore, we use RVGP to reconstruct high-density neural dynamics derived from low-density EEG recordings in healthy individuals and Alzheimer's patients. We show that vector field singularities are important disease markers and that their reconstruction leads to a comparable classification accuracy of disease states to high-density recordings. Thus, our method overcomes a significant practical limitation in experimental and clinical applications.
△ Less
Submitted 17 January, 2024; v1 submitted 28 September, 2023;
originally announced September 2023.
-
A FPGA-Based Broadband EIT System for Complex Bioimpedance Measurements -- Design and Performance Estimation
Authors:
Roman Kusche,
Ankit Malhotra,
Martin Ryschka,
Gunther Ardelt,
Paula Klimach,
Steffen Kaufmann
Abstract:
Electrical impedance tomography (EIT) is an imaging method that is able to estimate the electrical conductivity distribution of living tissue. This work presents a field programmable gate array (FPGA)-based multi-frequency EIT system for complex, time-resolved bioimpedance measurements. The system has the capability to work with measurement setups with up to 16 current electrodes and 16 voltage el…
▽ More
Electrical impedance tomography (EIT) is an imaging method that is able to estimate the electrical conductivity distribution of living tissue. This work presents a field programmable gate array (FPGA)-based multi-frequency EIT system for complex, time-resolved bioimpedance measurements. The system has the capability to work with measurement setups with up to 16 current electrodes and 16 voltage electrodes. The excitation current has a range of about 10 $μ$A to 5 mA, whereas the sinusoidal signal used for excitation can have a frequency of up to 500 kHz. Additionally, the usage of a chirp or rectangular signal excitation is possible. Furthermore, the described system has a sample rate of up to 3480 impedance spectra per second (ISPS). The performance of the EIT system is demonstrated with a resistor-based phantom and tank phantoms. Additionally, first measurements taken from the human thorax during a breathing cycle are presented.
△ Less
Submitted 13 August, 2020;
originally announced August 2020.
-
A System for In-Ear Pulse Wave Measurements
Authors:
Steffen Kaufmann,
Ankit Malhotra,
Gunther Ardelt,
Nele Hunsche,
Kerstin Bresslein,
Roman Kusche,
Martin Ryschka
Abstract:
The measurement of the pulse wave has proven to be a vital tool in medical diagnosis. Whereby most pulse wave measurements are carried out at extremities, this work proposes a system for measuring the pulse wave and the Pulse Arrival Time (PAT) in the interior of the ear. The developed measurement device is based on a battery powered microcontroller system. The measurement device can simultaneousl…
▽ More
The measurement of the pulse wave has proven to be a vital tool in medical diagnosis. Whereby most pulse wave measurements are carried out at extremities, this work proposes a system for measuring the pulse wave and the Pulse Arrival Time (PAT) in the interior of the ear. The developed measurement device is based on a battery powered microcontroller system. The measurement device can simultaneously acquire a single channel Electrocardiogram (ECG), a dual wavelengths Photoplethysmogram (PPG), the pressure in both ears, the body core temperature, as well the subjects motion. The acquired measurement data can either be saved on a micro SD-card or can be transmitted wireless via Bluetooth or wired via USB to a host PC for further analysis. In Bluetooth communication mode the device can operate battery powered up to 8 hours. In addition to the system description, first measurements carried out with the system will be presented.
△ Less
Submitted 6 August, 2020;
originally announced August 2020.
-
An In-Ear Pulse Wave Velocity Measurement System Using Heart Sounds as Time Reference
Authors:
Roman Kusche,
Paula Klimach,
Ankit Malhotra,
Steffen Kaufmann,
Martin Ryschka
Abstract:
Pulse wave measurements provide vital information in medical diagnosis. For this reason, a measurement system is developed for determining the transient time of the pulse wave between the heart and the ear. To detect pressure variations in the sealed ear canal, caused by the arriving pulse wave, an in-ear sensor is developed which uses heart sounds as time reference. Furthermore, for extracting th…
▽ More
Pulse wave measurements provide vital information in medical diagnosis. For this reason, a measurement system is developed for determining the transient time of the pulse wave between the heart and the ear. To detect pressure variations in the sealed ear canal, caused by the arriving pulse wave, an in-ear sensor is developed which uses heart sounds as time reference. Furthermore, for extracting the heart sounds from the pressure measurements and calculating the pulse wave transient time, a MATLAB-based algorithm is described. An embedded microcontroller based measurement board is presented, which realizes an interface between the sensor and the computer for signal processing.
△ Less
Submitted 5 August, 2020;
originally announced August 2020.
-
A Portable In-Ear Pulse Wave Measurement System
Authors:
Roman Kusche,
Ankit Malhotra,
Martin Ryschka,
Steffen Kaufmann
Abstract:
The measurement of the pulse wave has proven to be a vital tool in medical diagnosis. Whereby most pulse wave measurements are carried out at extremities, this work proposes a system for measuring the pulse wave and the Pulse Arrival Time (PAT) in the interior of the ear. The developed measurement device is based on a battery powered microcontroller system. The measurement device simultaneously ac…
▽ More
The measurement of the pulse wave has proven to be a vital tool in medical diagnosis. Whereby most pulse wave measurements are carried out at extremities, this work proposes a system for measuring the pulse wave and the Pulse Arrival Time (PAT) in the interior of the ear. The developed measurement device is based on a battery powered microcontroller system. The measurement device simultaneously acquires an Einthoven Lead II Electrocardiogram (ECG), a dual wavelength Photoplethysmogram (PPG), the pressure in both ears, the temperature inside the ear canal, as well as the subject's motion. The acquired measurement data can either be saved on a micro SD-card or can be transmitted wireless via Bluetooth or wired via USB to a host PC for further analysis. Battery powered the device can operate up to 8 hours. In addition to the system description, first measurements carried out with the system will be presented.
△ Less
Submitted 5 August, 2020;
originally announced August 2020.
-
Engineering Enhanced Thermal Transport in Layered Nanomaterials
Authors:
Abhinav Malhotra,
Kartik Kothari,
Martin Maldovan
Abstract:
A comprehensive rational thermal material design paradigm requires the ability to reduce and enhance the thermal conductivities of nanomaterials. In contrast to the existing ability to reduce the thermal conductivity, methods that allow to enhance heat conduction are currently limited. Enhancing the nanoscale thermal conductivity could bring radical improvements in the performance of electronics,…
▽ More
A comprehensive rational thermal material design paradigm requires the ability to reduce and enhance the thermal conductivities of nanomaterials. In contrast to the existing ability to reduce the thermal conductivity, methods that allow to enhance heat conduction are currently limited. Enhancing the nanoscale thermal conductivity could bring radical improvements in the performance of electronics, optoelectronics, and photovoltaic systems. Here, we show that enhanced thermal conductivities can be achieved in semiconductor nanostructures by rationally engineering phonon spectral coupling between materials. By embedding a germanium film between silicon layers, we show that its thermal conductivity can be increased by more than 100% at room temperature in contrast to a free standing thin-film. The injection of phonons from the cladding silicon layers creates the observed enhancement in thermal conductivity. We study the key factors underlying the phonon injection mechanism and find that the surface roughness and layer thicknesses play a determining role. The findings presented in this letter will allow for the creation of nanomaterials with an increased thermal conductivity.
△ Less
Submitted 5 October, 2017;
originally announced October 2017.