-
Image-Space Gridding for Nonrigid Motion-Corrected MR Image Reconstruction
Authors:
Kwang Eun Jang,
Mario O. Malavé,
Dwight G. Nishimura
Abstract:
Motion remains a major challenge in magnetic resonance (MR) imaging, particularly in free-breathing cardiac MR imaging, where data are acquired over multiple heartbeats at varying respiratory phases. We adopt a model-based approach for nonrigid motion correction, addressing two challenges: (a) motion representation and (b) motion estimation. For motion representation, we derive image-space griddin…
▽ More
Motion remains a major challenge in magnetic resonance (MR) imaging, particularly in free-breathing cardiac MR imaging, where data are acquired over multiple heartbeats at varying respiratory phases. We adopt a model-based approach for nonrigid motion correction, addressing two challenges: (a) motion representation and (b) motion estimation. For motion representation, we derive image-space gridding by adapting the nonuniform fast Fourier transform (NUFFT) to represent and compute nonrigid motion, which provides an exact forward-adjoint pair of linear operators. We then introduce nonrigid SENSE operators that incorporate nonrigid motion into the multi-coil MR acquisition model. For motion estimation, we employ both low-resolution 3D image-based navigators (iNAVs) and high-resolution 3D self-navigating image-based navigators (self-iNAVs). During each heartbeat, data are acquired along two types of non-Cartesian trajectories: a subset of a high-resolution trajectory that sparsely covers 3D k-space, followed by a full low-resolution trajectory. We reconstruct 3D iNAVs for each heartbeat using the full low-resolution data, which are then used to estimate bulk motion and identify the respiratory phase of each heartbeat. By combining data from multiple heartbeats within the same respiratory phase, we reconstruct high-resolution 3D self-iNAVs, allowing estimation of nonrigid respiratory motion. For each respiratory phase, we construct the nonrigid SENSE operator, reformulating the nonrigid motion-corrected reconstruction as a standard regularized inverse problem. In a preliminary study, the proposed method enhanced sharpness of the coronary arteries and improved image quality in non-cardiac regions, outperforming translational motion-corrected reconstruction.
△ Less
Submitted 28 January, 2025;
originally announced January 2025.
-
High-Resolution, Respiratory-Resolved Coronary MRA Using a Phyllotaxis-Reordered Variable-Density 3D Cones Trajectory
Authors:
Srivathsan P. Koundinyan,
Corey A. Baron,
Mario O. Malave,
Frank Ong,
Nii Okai Addy,
Joseph Y. Cheng,
Phillip C. Yang,
Bob S. Hu,
Dwight G. Nishimura
Abstract:
Purpose: To develop a respiratory-resolved motion-compensation method for free-breathing, high-resolution coronary magnetic resonance angiography using a 3D cones trajectory.
Methods: To achieve respiratory-resolved 0.98 mm resolution images in a clinically relevant scan time, we undersample the imaging data with a variable-density 3D cones trajectory. For retrospective motion compensation, tran…
▽ More
Purpose: To develop a respiratory-resolved motion-compensation method for free-breathing, high-resolution coronary magnetic resonance angiography using a 3D cones trajectory.
Methods: To achieve respiratory-resolved 0.98 mm resolution images in a clinically relevant scan time, we undersample the imaging data with a variable-density 3D cones trajectory. For retrospective motion compensation, translational estimates from 3D image-based navigators (3D iNAVs) are used to bin the imaging data into four phases from end-expiration to end-inspiration. To ensure pseudo-random undersampling within each respiratory phase, we devise a phyllotaxis readout ordering scheme mindful of eddy current artifacts in steady state free precession imaging. Following binning, residual 3D translational motion within each phase is computed using the 3D iNAVs and corrected for in the imaging data. The noise-like aliasing characteristic of the combined phyllotaxis and cones sampling pattern is leveraged in a compressed sensing reconstruction with spatial and temporal regularization to reduce aliasing in each of the respiratory phases.
Results: In a volunteer and 5 patients, respiratory motion compensation using the proposed method yields improved image quality compared to non-respiratory-resolved approaches with no motion correction and with 3D translational correction. Qualitative assessment by two cardiologists indicates the superior sharpness of coronary segments reconstructed with the proposed method (P < 0.01).
Conclusion: The proposed method better mitigates motion artifacts in free-breathing, high-resolution coronary angiography exams compared to translational correction.
△ Less
Submitted 27 October, 2019;
originally announced October 2019.
-
Unraveling the Effect of Spatial Resolution and Scan Acceleration on 3D Image-Based Navigators for Respiratory Motion Tracking in Coronary MR Angiography
Authors:
Srivathsan P. Koundinyan,
Joseph Y. Cheng,
Mario O. Malave,
Phillip C. Yang,
Bob S. Hu,
Dwight G. Nishimura,
Corey A. Baron
Abstract:
Purpose: To study the accuracy of motion information extracted from beat-to-beat 3D image-based navigators (3D iNAVs) collected using a variable-density cones trajectory with different combinations of spatial resolutions and scan acceleration factors.
Methods: Fully sampled, breath-held 4.4 mm 3D iNAV datasets for six respiratory phases are acquired in a volunteer. Ground truth translational and…
▽ More
Purpose: To study the accuracy of motion information extracted from beat-to-beat 3D image-based navigators (3D iNAVs) collected using a variable-density cones trajectory with different combinations of spatial resolutions and scan acceleration factors.
Methods: Fully sampled, breath-held 4.4 mm 3D iNAV datasets for six respiratory phases are acquired in a volunteer. Ground truth translational and nonrigid motion information is derived from these datasets. Subsequently, the motion estimates from synthesized undersampled 3D iNAVs with isotropic spatial resolutions of 4.4 mm (acceleration factor = 10.9), 5.4 mm (acceleration factor = 7.2), 6.4 mm (acceleration factor = 4.2), and 7.8 mm (acceleration factor = 2.9) are assessed against the ground truth information. The undersampled 3D iNAV configuration with the highest accuracy motion estimates in simulation is then compared with the originally proposed 4.4 mm undersampled 3D iNAV in six volunteer studies.
Results: The simulations indicate that for navigators beyond certain scan acceleration factors, the accuracy of motion estimates is compromised due to errors from residual aliasing and blurring/smoothening effects following compressed sensing reconstruction. The 6.4 mm 3D iNAV achieves an acceptable spatial resolution with a small acceleration factor, resulting in the highest accuracy motion information among all assessed undersampled 3D iNAVs. Reader scores for six volunteer studies demonstrate superior coronary vessel sharpness when applying an autofocusing nonrigid correction technique using the 6.4 mm 3D iNAVs in place of 4.4 mm 3D iNAVs.
Conclusion: Undersampled 6.4 mm 3D iNAVs enable motion tracking with improved accuracy relative to previously proposed undersampled 4.4 mm 3D iNAVs.
△ Less
Submitted 27 October, 2019;
originally announced October 2019.