-
Technical Design Report for the PANDA Endcap Disc DIRC
Authors:
Panda Collaboration,
F. Davi,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
F. Feldbauer,
M. Fink,
V. Freudenreich,
M. Fritsch,
F. H. Heinsius,
T. Held,
T. Holtmann,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann
, et al. (441 additional authors not shown)
Abstract:
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c.…
▽ More
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c. PANDA is designed to reach a maximum luminosity of 2x10^32 cm^2 s. Most of the physics programs require an excellent particle identification (PID). The PID of hadronic states at the forward endcap of the target spectrometer will be done by a fast and compact Cherenkov detector that uses the detection of internally reflected Cherenkov light (DIRC) principle. It is designed to cover the polar angle range from 5° to 22° and to provide a separation power for the separation of charged pions and kaons up to 3 standard deviations (s.d.) for particle momenta up to 4 GeV/c in order to cover the important particle phase space. This document describes the technical design and the expected performance of the novel PANDA Disc DIRC detector that has not been used in any other high energy physics experiment (HEP) before. The performance has been studied with Monte-Carlo simulations and various beam tests at DESY and CERN. The final design meets all PANDA requirements and guarantees suffcient safety margins.
△ Less
Submitted 29 December, 2019;
originally announced December 2019.
-
Feasibility study for the measurement of $πN$ TDAs at PANDA in $\bar{p}p\to J/ψπ^0$
Authors:
PANDA Collaboration,
B. Singh,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
M. Fink,
F. H. Heinsius,
T. Held,
T. Holtmann,
S. Jasper,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann,
M. Kümmel,
S. Leiber
, et al. (488 additional authors not shown)
Abstract:
The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as…
▽ More
The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as well as the background rejection from various sources including the $\bar{p}p\toπ^+π^-π^0$ and $\bar{p}p\to J/ψπ^0π^0$ reactions are performed with PandaRoot, the simulation and analysis software framework of the PANDA experiment. It is shown that the measurement can be done at PANDA with significant constraining power under the assumption of an integrated luminosity attainable in four to five months of data taking at the maximum design luminosity.
△ Less
Submitted 7 October, 2016;
originally announced October 2016.
-
Technical Design Report for the: PANDA Straw Tube Tracker
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
A. Aab,
M. Albrecht,
J. Becker,
A. Csapó,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
L. Klask,
H. Koch,
B. Kopf,
S. Leiber,
M. Leyhe
, et al. (451 additional authors not shown)
Abstract:
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory an…
▽ More
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory and the measurement of the specific energy-loss for a particle identification. Dedicated simulations with full analysis studies of certain proton-antiproton reactions, identified as being benchmark tests for the whole PANDA scientific program, have been performed to test the STT layout and performance. The results are presented, and the time lines to construct the STT are described.
△ Less
Submitted 4 June, 2012; v1 submitted 24 May, 2012;
originally announced May 2012.
-
Visible, EUV, and X-ray Spectroscopy at the NIST EBIT Facility
Authors:
J. D. Gillaspy,
B. Blagojevic,
A. Dalgarno,
K. Fahey,
V. Kharchenko,
J. M. Laming,
E. -O. Le Bigot,
L. Lugosi,
K. Makonyi,
L. P. Ratliff,
H. W. Schnopper,
E. H. Silver,
E. Takacs,
J. N. Tan,
H. Tawara,
K. Tokési
Abstract:
After a brief introduction to the NIST EBIT facility, we present the results of three different types of experiments that have been carried out there recently: EUV and visible spectroscopy in support of the microelectronics industry, laboratory astrophysics using an x-ray microcalorimeter, and charge exchange studies using extracted beams of highly charged ions.
After a brief introduction to the NIST EBIT facility, we present the results of three different types of experiments that have been carried out there recently: EUV and visible spectroscopy in support of the microelectronics industry, laboratory astrophysics using an x-ray microcalorimeter, and charge exchange studies using extracted beams of highly charged ions.
△ Less
Submitted 16 March, 2006;
originally announced March 2006.
-
A High Efficiency Ultra High Vacuum Compatible Flat Field Spectrometer for EUV Wavelengths
Authors:
B. Blagojevic,
Eric-Olivier Le Bigot,
K. Fahy,
A. Aguilar,
K. Makonyi,
E. Takács,
J. N. Tan,
J. M. Pomeroy,
J. H. Burnett,
J. D. Gillaspy,
J. R. Roberts
Abstract:
A custom, flat field, extreme ultraviolet EUV spectrometer built specifically for use with low power light sources that operate under ultrahigh vacuum conditions is reported. The spectral range of the spectrometer extends from 4 nm to 40 nm. The instrument optimizes the light gathering power and signal to noise ratio while achieving good resolution. A detailed description of the spectrometer and…
▽ More
A custom, flat field, extreme ultraviolet EUV spectrometer built specifically for use with low power light sources that operate under ultrahigh vacuum conditions is reported. The spectral range of the spectrometer extends from 4 nm to 40 nm. The instrument optimizes the light gathering power and signal to noise ratio while achieving good resolution. A detailed description of the spectrometer and design considerations are presented, as well as a novel procedure that could be used to obtain a synthetic wavelength calibration with the aid of only a single known spectral feature. This synthetic wavelength calibration is compared to a standard wavelength calibration obtained from previously reported spectral lines of Xe, Ar and Ne ions recorded with this spectrometer.
△ Less
Submitted 8 August, 2005;
originally announced August 2005.