Non-magnetic glass-fiber cryostat for MADMAX prototype tests
Authors:
D. Kreikemeyer-Lorenzo,
T. Koettig,
P. Borges de Sousa,
C. Gooch,
D. Kittlinger,
B. Majorovits,
J. P. A. Maldonado,
P. Pralavorio
Abstract:
MADMAX, an axion dark matter search experiment, is currently in the prototype testing phase. Its working principle is based on the conversion of axions in a magnetic field into photons. This signal is then enhanced by a booster made of dielectric disks placed in front of a mirror. In order to test MADMAX prototypes at cryogenic temperatures in a magnetic field parallel to the disks, a new G-10 gla…
▽ More
MADMAX, an axion dark matter search experiment, is currently in the prototype testing phase. Its working principle is based on the conversion of axions in a magnetic field into photons. This signal is then enhanced by a booster made of dielectric disks placed in front of a mirror. In order to test MADMAX prototypes at cryogenic temperatures in a magnetic field parallel to the disks, a new G-10 glass-fiber cryostat of 0.06 m$^3$ inner volume was designed, tested and used in a CERN magnet. The design allows to minimise cost as well as cooling down and warming up times. Using continuous circulation flow of gaseous helium, the MADMAX prototype was cooled down reproducibly to temperatures below 10 K for more than 24 hours. This procedure allowed, for the first time, to perform a calibration of the booster response and to run a dark matter axion search in a magnetic field at low temperatures. This novel type of cryostat, with a low manufacturing cost, fast and easy to operate, could be used for other purposes beyond MADMAX.
△ Less
Submitted 3 March, 2025; v1 submitted 17 December, 2024;
originally announced December 2024.
-
First search for dark photon dark matter with a MADMAX prototype
Authors:
J. Egge,
D. Leppla-Weber,
S. Knirck,
B. Ary dos Santos Garcia,
D. Bergermann,
A. Caldwell,
V. Dabhi,
C. Diaconu,
J. Diehl,
G. Dvali,
M. Ekmedžić,
F. Gallo,
E. Garutti,
S. Heyminck,
F. Hubaut,
A. Ivanov,
J. Jochum,
P. Karst,
M. Kramer,
D. Kreikemeyer-Lorenzo,
C. Krieger,
C. Lee,
A. Lindner,
J. P. A. Maldonado,
B. Majorovits
, et al. (21 additional authors not shown)
Abstract:
We report the first result from a dark photon dark matter search in the mass range from ${78.62}$ to $83.95~\mathrm{μeV}/c^2$ with a dielectric haloscope prototype for MADMAX (Magnetized Disc and Mirror Axion eXperiment). Putative dark photons would convert to observable photons within a stack consisting of three sapphire disks and a mirror. The emitted power of this system is received by an anten…
▽ More
We report the first result from a dark photon dark matter search in the mass range from ${78.62}$ to $83.95~\mathrm{μeV}/c^2$ with a dielectric haloscope prototype for MADMAX (Magnetized Disc and Mirror Axion eXperiment). Putative dark photons would convert to observable photons within a stack consisting of three sapphire disks and a mirror. The emitted power of this system is received by an antenna and successively digitized using a low-noise receiver. No dark photon signal has been observed. Assuming unpolarized dark photon dark matter with a local density of $ρ_χ=0.3~\mathrm{GeV/cm^3}$ we exclude a dark photon to photon mixing parameter $χ> 2.7 \times 10^{-12}$ over the full mass range and $χ> 1.1 \times 10^{-13}$ at a mass of $80.57~\mathrm{μeV}/c^2$ with a 95\% confidence level. This is the first physics result from a MADMAX prototype and exceeds previous constraints on $χ$ in this mass range by up to almost three orders of magnitude.
△ Less
Submitted 7 March, 2025; v1 submitted 5 August, 2024;
originally announced August 2024.
-
First mechanical realization of a tunable dielectric haloscope for the MADMAX axion search experiment
Authors:
The MADMAX Collaboration,
B. Ary Dos Santos Garcia,
D. Bergermann,
A. Caldwell,
V. Dabhi,
C. Diaconu,
J. Diehl,
G. Dvali,
J. Egge,
M. Ekmedzic,
F. Gallo,
E. Garutti,
S. Heyminck,
F. Hubaut,
A. Ivanov,
J. Jochum,
P. Karst,
M. Kramer,
D. Kreikemeyer-Lorenzo,
C. Krieger,
D. Leppla-Weber,
A. Lindner,
J. Maldonado,
B. Majorovits,
S. Martens
, et al. (14 additional authors not shown)
Abstract:
MADMAX, a future experiment to search for axion dark matter, is based on a novel detection concept called the dielectric haloscope. It consists of a booster composed of several dielectric disks positioned with $μ$m precision. A prototype composed of one movable disk was built to demonstrate the mechanical feasibility of such a booster in the challenging environment of the experiment: high magnetic…
▽ More
MADMAX, a future experiment to search for axion dark matter, is based on a novel detection concept called the dielectric haloscope. It consists of a booster composed of several dielectric disks positioned with $μ$m precision. A prototype composed of one movable disk was built to demonstrate the mechanical feasibility of such a booster in the challenging environment of the experiment: high magnetic field to convert the axions into photons and cryogenic temperature to reduce the thermal noise. It was tested both inside a strong magnetic field up to 1.6 T and at cryogenic temperatures down to 35K. The measurements of the velocity and positioning accuracy of the disk are shown and are found to match the MADMAX requirements.
△ Less
Submitted 11 November, 2024; v1 submitted 15 July, 2024;
originally announced July 2024.
-
Qualification of piezo-electric actuators for the MADMAX booster system at cryogenic temperatures and high magnetic fields
Authors:
E. Garutti,
H. Janssen,
D. Kreikemeyer-Lorenzo,
C. Krieger,
A. Lindner,
B. Majorovits,
J. Schaffran,
B. van Bree
Abstract:
We report on the qualification of a piezo-based linear stage for the manipulation of positions of dielectric discs in the booster of the MADMAX axion dark matter search experiment. A first demonstrator of the piezo drives, specifically developed for MADMAX, was tested at room temperature as well as at cryogenic temperatures down to 4.5 K and inside strong magnetic fields up to 5.3 T. These qualifi…
▽ More
We report on the qualification of a piezo-based linear stage for the manipulation of positions of dielectric discs in the booster of the MADMAX axion dark matter search experiment. A first demonstrator of the piezo drives, specifically developed for MADMAX, was tested at room temperature as well as at cryogenic temperatures down to 4.5 K and inside strong magnetic fields up to 5.3 T. These qualification measurements prove that the piezo-based linear stage is suited for MADMAX and fulfills the requirements.
△ Less
Submitted 7 July, 2023; v1 submitted 22 May, 2023;
originally announced May 2023.
-
Liquid argon light collection and veto modeling in GERDA Phase II
Authors:
GERDA collaboration,
M. Agostini,
A. Alexander,
G. R. Araujo,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
S. Belogurov,
A. Bettini,
L. Bezrukov,
V. Biancacci,
E. Bossio,
V. Bothe,
R. Brugnera,
A. Caldwell,
S. Calgaro,
C. Cattadori,
A. Chernogorov,
P-J. Chiu,
T. Comellato,
V. D'Andrea,
E. V. Demidova,
A. Di Giacinto
, et al. (94 additional authors not shown)
Abstract:
The ability to detect liquid argon scintillation light from within a densely packed high-purity germanium detector array allowed the GERDA experiment to reach an exceptionally low background rate in the search for neutrinoless double beta decay of $^{76}$Ge. Proper modeling of the light propagation throughout the experimental setup, from any origin in the liquid argon volume to its eventual detect…
▽ More
The ability to detect liquid argon scintillation light from within a densely packed high-purity germanium detector array allowed the GERDA experiment to reach an exceptionally low background rate in the search for neutrinoless double beta decay of $^{76}$Ge. Proper modeling of the light propagation throughout the experimental setup, from any origin in the liquid argon volume to its eventual detection by the novel light read-out system, provides insight into the rejection capability and is a necessary ingredient to obtain robust background predictions. In this paper, we present a model of the GERDA liquid argon veto, as obtained by Monte Carlo simulations and constrained by calibration data, and highlight its application for background decomposition.
△ Less
Submitted 6 December, 2022;
originally announced December 2022.
-
Optical properties of low background PEN structural components for the LEGEND-200 experiment
Authors:
L. Manzanillas,
Y. Efremenko,
M. Febbraro,
F. Fischer,
M. Guitart Corominas,
B. Hackett,
A. Leonhardt,
B. Majorovits,
O. Schulz
Abstract:
Polyethylene Naphthalate (PEN) plastic scintillator has been identified as potential self-vetoing structural material in low-background physics experiments. Scintillating components have been produced radio-pure from PEN using injection compression molding technology. These low-background PEN components will be used as active holders to mount the Germanium detectors in the \legend-$200$ neutrinole…
▽ More
Polyethylene Naphthalate (PEN) plastic scintillator has been identified as potential self-vetoing structural material in low-background physics experiments. Scintillating components have been produced radio-pure from PEN using injection compression molding technology. These low-background PEN components will be used as active holders to mount the Germanium detectors in the \legend-$200$ neutrinoless double beta decay experiment. In this paper we present the measurement of the optical properties of these PEN components. Thus, the emission spectrum, time constant, attenuation and bulk absorption length as well as light output and light yield are reported. In addition, the surface of these PEN components has been characterized and an estimation of the surface roughness is presented. Moreover, the light output of the final \legend-$200$ detector holders has been measured and is reported. These measurements were used to estimate the self-vetoing efficiency of these holders.
△ Less
Submitted 30 August, 2022; v1 submitted 28 April, 2022;
originally announced April 2022.
-
Axion Dark Matter
Authors:
C. B. Adams,
N. Aggarwal,
A. Agrawal,
R. Balafendiev,
C. Bartram,
M. Baryakhtar,
H. Bekker,
P. Belov,
K. K. Berggren,
A. Berlin,
C. Boutan,
D. Bowring,
D. Budker,
A. Caldwell,
P. Carenza,
G. Carosi,
R. Cervantes,
S. S. Chakrabarty,
S. Chaudhuri,
T. Y. Chen,
S. Cheong,
A. Chou,
R. T. Co,
J. Conrad,
D. Croon
, et al. (130 additional authors not shown)
Abstract:
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synerg…
▽ More
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.
△ Less
Submitted 29 March, 2023; v1 submitted 28 March, 2022;
originally announced March 2022.
-
Pulse shape analysis in GERDA Phase II
Authors:
The GERDA collaboration,
M. Agostini,
G. Araujo,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
E. Bellotti,
S. Belogurov,
A. Bettini,
L. Bezrukov,
V. Biancacci,
E. Bossio,
V. Bothe,
V. Brudanin,
R. Brugnera,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
T. Comellato,
V. D'Andrea,
E. V. Demidova,
N. Di Marco,
E. Doroshkevich
, et al. (91 additional authors not shown)
Abstract:
The GERmanium Detector Array (GERDA) collaboration searched for neutrinoless double-$β$ decay in $^{76}$Ge using isotopically enriched high purity germanium detectors at the Laboratori Nazionali del Gran Sasso of INFN. After Phase I (2011-2013), the experiment benefited from several upgrades, including an additional active veto based on LAr instrumentation and a significant increase of mass by poi…
▽ More
The GERmanium Detector Array (GERDA) collaboration searched for neutrinoless double-$β$ decay in $^{76}$Ge using isotopically enriched high purity germanium detectors at the Laboratori Nazionali del Gran Sasso of INFN. After Phase I (2011-2013), the experiment benefited from several upgrades, including an additional active veto based on LAr instrumentation and a significant increase of mass by point-contact germanium detectors that improved the half-life sensitivity of Phase II (2015-2019) by an order of magnitude. At the core of the background mitigation strategy, the analysis of the time profile of individual pulses provides a powerful topological discrimination of signal-like and background-like events. Data from regular $^{228}$Th calibrations and physics data were both considered in the evaluation of the pulse shape discrimination performance. In this work, we describe the various methods applied to the data collected in GERDA Phase II corresponding to an exposure of 103.7 kg$\cdot$yr. These methods suppress the background by a factor of about 5 in the region of interest around Q$_{ββ}$ = 2039 keV, while preserving (81$\pm$3)% of the signal. In addition, an exhaustive list of parameters is provided which were used in the final data analysis.
△ Less
Submitted 27 February, 2022;
originally announced February 2022.
-
Production and validation of scintillating structural components from low-background Poly(ethylene naphthalate)
Authors:
Y. Efremenko,
M. Febbraro,
F. Fischer,
M. Guitart Corominas,
K. Gusev,
B. Hackett,
C. Hayward,
R. Hodák,
P. Krause,
B. Majorovits,
L. Manzanillas,
D. Muenstermann,
M. Pohl,
R. Rouhana,
D. Radford,
E. Rukhadze,
N. Rumyantseva,
I. Schilling,
S. Schoenert,
O. Schulz,
M. Schwarz,
I. Štekl,
M. Stommel,
J. Weingarten,
E. Hoppe
, et al. (6 additional authors not shown)
Abstract:
Poly Ethylene Naphthalate (PEN) is an industrial polymer plastic which is investigated as a low background, transparent, scintillating and wavelength shifting structural material. PEN scintillates in the blue region and has excellent mechanical properties both at room and cryogenic temperatures. Thus, it is an ideal candidate for active structural components in experiments for the search of rare e…
▽ More
Poly Ethylene Naphthalate (PEN) is an industrial polymer plastic which is investigated as a low background, transparent, scintillating and wavelength shifting structural material. PEN scintillates in the blue region and has excellent mechanical properties both at room and cryogenic temperatures. Thus, it is an ideal candidate for active structural components in experiments for the search of rare events like neutrinoless double-beta decay or dark matter recoils. Such optically active structures improve the identification and rejection efficiency of background events, like this improving the sensitivity of experiments. This paper reports on the production of radiopure and transparent PEN plates These structures can be used to mount germanium detectors operating in cryogenic liquids (LAr, LN). Thus, as first application PEN holders will be used to mount the Ge detectors in the LEGEND-200 experiment. The whole process from cleaning the raw material to testing the PEN active components under final operational conditions is reported.
△ Less
Submitted 21 November, 2022; v1 submitted 25 October, 2021;
originally announced October 2021.
-
LEGEND-1000 Preconceptual Design Report
Authors:
LEGEND Collaboration,
N. Abgrall,
I. Abt,
M. Agostini,
A. Alexander,
C. Andreoiu,
G. R. Araujo,
F. T. Avignone III,
W. Bae,
A. Bakalyarov,
M. Balata,
M. Bantel,
I. Barabanov,
A. S. Barabash,
P. S. Barbeau,
C. J. Barton,
P. J. Barton,
L. Baudis,
C. Bauer,
E. Bernieri,
L. Bezrukov,
K. H. Bhimani,
V. Biancacci,
E. Blalock,
A. Bolozdynya
, et al. (239 additional authors not shown)
Abstract:
We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $ββ$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory…
▽ More
We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $ββ$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory. By combining the lowest background levels with the best energy resolution in the field, LEGEND-1000 will perform a quasi-background-free search and can make an unambiguous discovery of neutrinoless double-beta decay with just a handful of counts at the decay $Q$ value. The experiment is designed to probe this decay with a 99.7%-CL discovery sensitivity in the $^{76}$Ge half-life of $1.3\times10^{28}$ years, corresponding to an effective Majorana mass upper limit in the range of 9-21 meV, to cover the inverted-ordering neutrino mass scale with 10 yr of live time.
△ Less
Submitted 23 July, 2021;
originally announced July 2021.
-
Simulating MADMAX in 3D: Requirements for Dielectric Axion Haloscopes
Authors:
S. Knirck,
J. Schütte-Engel,
S. Beurthey,
D. Breitmoser,
A. Caldwell,
C. Diaconu,
J. Diehl,
J. Egge,
M. Esposito,
A. Gardikiotis,
E. Garutti,
S. Heyminck,
F. Hubaut,
J. Jochum,
P. Karst,
M. Kramer,
C. Krieger,
D. Labat,
C. Lee,
X. Li,
A. Lindner,
B. Majorovits,
S. Martens,
M. Matysek,
E. Öz
, et al. (16 additional authors not shown)
Abstract:
We present 3D calculations for dielectric haloscopes such as the currently envisioned MADMAX experiment. For ideal systems with perfectly flat, parallel and isotropic dielectric disks of finite diameter, we find that a geometrical form factor reduces the emitted power by up to $30\,\%$ compared to earlier 1D calculations. We derive the emitted beam shape, which is important for antenna design. We…
▽ More
We present 3D calculations for dielectric haloscopes such as the currently envisioned MADMAX experiment. For ideal systems with perfectly flat, parallel and isotropic dielectric disks of finite diameter, we find that a geometrical form factor reduces the emitted power by up to $30\,\%$ compared to earlier 1D calculations. We derive the emitted beam shape, which is important for antenna design. We show that realistic dark matter axion velocities of $10^{-3} c$ and inhomogeneities of the external magnetic field at the scale of $10\,\%$ have negligible impact on the sensitivity of MADMAX. We investigate design requirements for which the emitted power changes by less than $20\,\%$ for a benchmark boost factor with a bandwidth of $50\,{\rm MHz}$ at $22\,{\rm GHz}$, corresponding to an axion mass of $90\,μ{\rm eV}$. We find that the maximum allowed disk tilt is $100\,μ{\rm m}$ divided by the disk diameter, the required disk planarity is $20\,μ{\rm m}$ (min-to-max) or better, and the maximum allowed surface roughness is $100\,μ{\rm m}$ (min-to-max). We show how using tiled dielectric disks glued together from multiple smaller patches can affect the beam shape and antenna coupling.
△ Less
Submitted 13 October, 2021; v1 submitted 13 April, 2021;
originally announced April 2021.
-
Characterization of inverted coaxial $^{76}$Ge detectors in GERDA for future double-$β$ decay experiments
Authors:
GERDA collaboration,
M. Agostini,
G. R. Araujo,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
E. Bellotti,
S. Belogurov,
A. Bettini,
L. Bezrukov,
V. Biancacci,
E. Bossio,
V. Bothe,
V. Brudanin,
R. Brugnera,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
T. Comellato,
V. D'Andrea,
E. V. Demidova,
N. Di Marco,
E. Doroshkevich
, et al. (86 additional authors not shown)
Abstract:
Neutrinoless double-$β$ decay of $^{76}$Ge is searched for with germanium detectors where source and detector of the decay are identical. For the success of future experiments it is important to increase the mass of the detectors. We report here on the characterization and testing of five prototype detectors manufactured in inverted coaxial (IC) geometry from material enriched to 88% in $^{76}$Ge.…
▽ More
Neutrinoless double-$β$ decay of $^{76}$Ge is searched for with germanium detectors where source and detector of the decay are identical. For the success of future experiments it is important to increase the mass of the detectors. We report here on the characterization and testing of five prototype detectors manufactured in inverted coaxial (IC) geometry from material enriched to 88% in $^{76}$Ge. IC detectors combine the large mass of the traditional semi-coaxial Ge detectors with the superior resolution and pulse shape discrimination power of point contact detectors which exhibited so far much lower mass. Their performance has been found to be satisfactory both when operated in vacuum cryostat and bare in liquid argon within the GERDA setup. The measured resolutions at the Q-value for double-$β$ decay of $^{76}$Ge (Q$_{ββ}$ = 2039 keV) are about 2.1 keV full width at half maximum in vacuum cryostat. After 18 months of operation within the ultra-low background environment of the GERmanium Detector Array (GERDA) experiment and an accumulated exposure of 8.5 kg$\cdot$yr, the background index after analysis cuts is measured to be $4.9^{+7.3}_{-3.4}\times 10^{-4}$ counts /(keV$\cdot$kg$\cdot$yr) around Q$_{ββ}$. This work confirms the feasibility of IC detectors for the next-generation experiment LEGEND.
△ Less
Submitted 28 March, 2021;
originally announced March 2021.
-
Calibration of the GERDA experiment
Authors:
GERDA collaboration,
M. Agostini,
G. R. Araujo,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
E. Bellotti,
S. Belogurov,
A. Bettini,
L. Bezrukov,
V. Biancacci,
E. Bossio,
V. Bothe,
V. Brudanin,
R. Brugnera,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
T. Comellato,
V. D'Andrea,
E. V. Demidova,
N. Di Marco,
E. Doroshkevich
, et al. (87 additional authors not shown)
Abstract:
The GERmanium Detector Array (GERDA) collaboration searched for neutrinoless double-$β$ decay in $^{76}$Ge with an array of about 40 high-purity isotopically-enriched germanium detectors. The experimental signature of the decay is a monoenergetic signal at Q$_{ββ}$ = 2039.061(7)keV in the measured summed energy spectrum of the two emitted electrons. Both the energy reconstruction and resolution of…
▽ More
The GERmanium Detector Array (GERDA) collaboration searched for neutrinoless double-$β$ decay in $^{76}$Ge with an array of about 40 high-purity isotopically-enriched germanium detectors. The experimental signature of the decay is a monoenergetic signal at Q$_{ββ}$ = 2039.061(7)keV in the measured summed energy spectrum of the two emitted electrons. Both the energy reconstruction and resolution of the germanium detectors are crucial to separate a potential signal from various backgrounds, such as neutrino-accompanied double-$β$ decays allowed by the Standard Model. The energy resolution and stability were determined and monitored as a function of time using data from regular $^{228}$Th calibrations. In this work, we describe the calibration process and associated data analysis of the full GERDA dataset, tailored to preserve the excellent resolution of the individual germanium detectors when combining data over several years.
△ Less
Submitted 25 March, 2021;
originally announced March 2021.
-
Usage of PEN as self-vetoing structural material in low background experiments
Authors:
I. Abt,
Y. Efremenko,
M. Febbraro,
F. Fischer,
M. Guitart,
K. Gusev,
B. Hackett,
C. Hayward,
R. Hodak,
P. Krause,
B. Majorovits,
L. Manzanillas,
D. Muenstermann,
R. Pjatkan,
M. Pohl,
R. Rouhana,
D. Radford,
E. Rukhadze,
N. Rumyantseva,
I. Schilling,
S. Schoenert,
O. Schulz,
M. Schwarz,
M. Stommel,
J. Weingarten
Abstract:
PEN is an industrial polyester plastic which has become interesting for the physics community as a new type of plastic scintillator. PEN scintillates in the blue regime, which is ideal for most photosensor devices. In addition, PEN has excellent mechanical properties and very good radiopurity has been achieved. Thus, it is an ideal candidate for active structural components in low-background exper…
▽ More
PEN is an industrial polyester plastic which has become interesting for the physics community as a new type of plastic scintillator. PEN scintillates in the blue regime, which is ideal for most photosensor devices. In addition, PEN has excellent mechanical properties and very good radiopurity has been achieved. Thus, it is an ideal candidate for active structural components in low-background experiments. One possible application are holders for germanium detectors operating in cryogenic liquids (LAr, LN2). Such structures can help to reject surface and external backgrounds, boosting the sensitivity of experiments. In this contribution, the R\&D on PEN is outlined and an evaluation of the first production of PEN structures for the LEGEND-200 experiment is reported.
△ Less
Submitted 9 December, 2020; v1 submitted 16 November, 2020;
originally announced November 2020.
-
Final Results of GERDA on the Search for Neutrinoless Double-$β$ Decay
Authors:
GERDA collaboration,
M. Agostini,
G. R. Araujo,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
E. Bellotti,
S. Belogurov,
A. Bettini,
L. Bezrukov,
V. Biancacci,
D. Borowicz,
E. Bossio,
V. Bothe,
V. Brudanin,
R. Brugnera,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
T. Comellato,
V. D'Andrea,
E. V. Demidova,
N. Di Marco
, et al. (90 additional authors not shown)
Abstract:
The GERmanium Detector Array (GERDA) experiment searched for the lepton-number-violating neutrinoless double-$β$ ($0νββ$) decay of $^{76}$Ge, whose discovery would have far-reaching implications in cosmology and particle physics. By operating bare germanium diodes, enriched in $^{76}$Ge, in an active liquid argon shield, GERDA achieved an unprecedently low background index of $5.2\times10^{-4}$ co…
▽ More
The GERmanium Detector Array (GERDA) experiment searched for the lepton-number-violating neutrinoless double-$β$ ($0νββ$) decay of $^{76}$Ge, whose discovery would have far-reaching implications in cosmology and particle physics. By operating bare germanium diodes, enriched in $^{76}$Ge, in an active liquid argon shield, GERDA achieved an unprecedently low background index of $5.2\times10^{-4}$ counts/(keV$\cdot$kg$\cdot$yr) in the signal region and met the design goal to collect an exposure of 100 kg$\cdot$yr in a background-free regime. When combined with the result of Phase I, no signal is observed after 127.2 kg$\cdot$yr of total exposure. A limit on the half-life of $0νββ$ decay in $^{76}$Ge is set at $T_{1/2}>1.8\times10^{26}$ yr at 90% C.L., which coincides with the sensitivity assuming no signal.
△ Less
Submitted 13 September, 2020;
originally announced September 2020.
-
MADMAX Status Report
Authors:
S. Beurthey,
N. Böhmer,
P. Brun,
A. Caldwell,
L. Chevalier,
C. Diaconu,
G. Dvali,
P. Freire,
E. Garutti,
C. Gooch,
A. Hambarzumjan,
S. Heyminck,
F. Hubaut,
J. Jochum,
P. Karst,
S. Khan,
D. Kittlinger,
S. Knirck,
M. Kramer,
C. Krieger,
T. Lasserre,
C. Lee,
X. Li,
A. Lindner,
B. Majorovits
, et al. (20 additional authors not shown)
Abstract:
In this report we present the status of the MAgnetized Disk and Mirror Axion eXperiment (MADMAX), the first dielectric haloscope for the direct search of dark matter axions in the mass range of 40 to 400 $μ$eV. MADMAX will consist of several parallel dielectric disks, which are placed in a strong magnetic field and with adjustable separations. This setting is expected to allow for an observable em…
▽ More
In this report we present the status of the MAgnetized Disk and Mirror Axion eXperiment (MADMAX), the first dielectric haloscope for the direct search of dark matter axions in the mass range of 40 to 400 $μ$eV. MADMAX will consist of several parallel dielectric disks, which are placed in a strong magnetic field and with adjustable separations. This setting is expected to allow for an observable emission of axion induced electromagnetic waves at a frequency between 10 and 100 GHz corresponding to the axion mass. The present document orignated from a status report to the DESY PRC in 2019.
△ Less
Submitted 28 October, 2020; v1 submitted 24 March, 2020;
originally announced March 2020.
-
A first proof of principle booster setup for the MADMAX dielectric haloscope
Authors:
Jacob Egge,
Stefan Knirck,
Béla Majorovits,
Christopher Moore,
Olaf Reimann
Abstract:
Axions and axion-like particles are excellent low-mass dark matter candidates. The MADMAX experiment aims to directly detect galactic axions with masses between $40\,μ{\rm eV}$ and $400\,μ{\rm eV}$ by using the axion-induced emission of electromagnetic waves from boundaries between materials of different dielectric constants under a strong magnetic field. Combining many such surfaces, this emissio…
▽ More
Axions and axion-like particles are excellent low-mass dark matter candidates. The MADMAX experiment aims to directly detect galactic axions with masses between $40\,μ{\rm eV}$ and $400\,μ{\rm eV}$ by using the axion-induced emission of electromagnetic waves from boundaries between materials of different dielectric constants under a strong magnetic field. Combining many such surfaces, this emission can be significantly enhanced (boosted) using constructive interference and resonances. We present a first proof of principle realization of such a booster system consisting of a copper mirror and up to five sapphire disks. The electromagnetic response of the system is investigated by reflectivity measurements. The mechanical accuracy, calibration process of unwanted reflections and the repeatability of a basic tuning algorithm to place the disks are investigated. We find that for the presented cases the electromagnetic response in terms of the group delay predicted by one-dimensional calculations is sufficiently realized in our setup. The repeatability of the tuning is at the percent level, and would have small impact on the sensitivity of such a booster.
△ Less
Submitted 11 May, 2020; v1 submitted 13 January, 2020;
originally announced January 2020.
-
Modeling of GERDA Phase II data
Authors:
GERDA collaboration,
Matteo Agostini,
Alexander M. Bakalyarov,
Marco Balata,
Igor Barabanov,
Laura Baudis,
Christian Bauer,
Enrico Bellotti,
Sergej Belogurov,
Alessandro Bettini,
Leonid Bezrukov,
Dariusz Borowicz,
Elisabetta Bossio,
Vikas Bothe,
Victor Brudanin,
Riccardo Brugnera,
Allen Caldwell,
Carla Cattadori,
Andrey Chernogorov,
Tommaso Comellato,
Valerio D'Andrea,
Elena V. Demidova,
Natalia Di Marco,
Alexander Domula,
Evgenyi Doroshkevich
, et al. (85 additional authors not shown)
Abstract:
The GERmanium Detector Array (GERDA) experiment at the Gran Sasso underground laboratory (LNGS) of INFN is searching for neutrinoless double-beta ($0νββ$) decay of $^{76}$Ge. The technological challenge of GERDA is to operate in a "background-free" regime in the region of interest (ROI) after analysis cuts for the full 100$\,$kg$\cdot$yr target exposure of the experiment. A careful modeling and de…
▽ More
The GERmanium Detector Array (GERDA) experiment at the Gran Sasso underground laboratory (LNGS) of INFN is searching for neutrinoless double-beta ($0νββ$) decay of $^{76}$Ge. The technological challenge of GERDA is to operate in a "background-free" regime in the region of interest (ROI) after analysis cuts for the full 100$\,$kg$\cdot$yr target exposure of the experiment. A careful modeling and decomposition of the full-range energy spectrum is essential to predict the shape and composition of events in the ROI around $Q_{ββ}$ for the $0νββ$ search, to extract a precise measurement of the half-life of the double-beta decay mode with neutrinos ($2νββ$) and in order to identify the location of residual impurities. The latter will permit future experiments to build strategies in order to further lower the background and achieve even better sensitivities. In this article the background decomposition prior to analysis cuts is presented for GERDA Phase II. The background model fit yields a flat spectrum in the ROI with a background index (BI) of $16.04^{+0.78}_{-0.85} \cdot 10^{-3}\,$cts/(kg$\cdot$keV$\cdot$yr) for the enriched BEGe data set and $14.68^{+0.47}_{-0.52} \cdot 10^{-3}\,$cts/(kg$\cdot$keV$\cdot$yr) for the enriched coaxial data set. These values are similar to the one of Gerda Phase I despite a much larger number of detectors and hence radioactive hardware components.
△ Less
Submitted 18 October, 2019; v1 submitted 5 September, 2019;
originally announced September 2019.
-
Deep learning based pulse shape discrimination for germanium detectors
Authors:
P. Holl,
L. Hauertmann,
B. Majorovits,
O. Schulz,
M. Schuster,
A. J. Zsigmond
Abstract:
Experiments searching for rare processes like neutrinoless double beta decay heavily rely on the identification of background events to reduce their background level and increase their sensitivity. We present a novel machine learning based method to recognize one of the most abundant classes of background events in these experiments. By combining a neural network for feature extraction with a smal…
▽ More
Experiments searching for rare processes like neutrinoless double beta decay heavily rely on the identification of background events to reduce their background level and increase their sensitivity. We present a novel machine learning based method to recognize one of the most abundant classes of background events in these experiments. By combining a neural network for feature extraction with a smaller classification network, our method can be trained with only a small number of labeled events. To validate our method, we use signals from a broad-energy germanium detector irradiated with a $^{228}$Th gamma source. We find that it matches the performance of state-of-the-art algorithms commonly used for this detector type. However, it requires less tuning and calibration and shows potential to identify certain types of background events missed by other methods.
△ Less
Submitted 2 June, 2019; v1 submitted 4 March, 2019;
originally announced March 2019.
-
A new experimental approach to probe QCD axion dark matter in the mass range above 40$μ$eV
Authors:
The MADMAX Collaboration,
P. Brun,
A. Caldwell,
L. Chevalier,
G. Dvali,
P. Freire,
E. Garutti,
S. Heyminck,
J. Jochum,
S. Knirck,
M. Kramer,
C. Krieger,
T. Lasserre,
C. Lee,
X. Li,
A. Lindner,
B. Majorovits,
S. Martens,
M. Matysek,
A. Millar,
G. Raffelt,
J. Redondo,
O. Reimann,
A. Ringwald,
K. Saikawa
, et al. (6 additional authors not shown)
Abstract:
The axion emerges in extensions of the Standard Model that explain the absence of CP violation in the strong interactions. Simultaneously, it can provide naturally the cold dark matter in our universe. Several searches for axions and axion-like particles (ALPs) have constrained the corresponding parameter space over the last decades but no unambiguous hints of their existence have been found. The…
▽ More
The axion emerges in extensions of the Standard Model that explain the absence of CP violation in the strong interactions. Simultaneously, it can provide naturally the cold dark matter in our universe. Several searches for axions and axion-like particles (ALPs) have constrained the corresponding parameter space over the last decades but no unambiguous hints of their existence have been found. The axion mass range below 1 meV remains highly attractive and a well motivated region for dark matter axions. In this White Paper we present a description of a new experiment based on the concept of a dielectric haloscope for the direct search of dark matter axions in the mass range of 40 to 400 $μ$eV. This MAgnetized Disk and Mirror Axion eXperiment (MADMAX) will consist of several parallel dielectric disks, which are placed in a strong magnetic field and with adjustable separations. This setting is expected to allow for an observable emission of axion induced electromagnetic waves at a frequency between 10 to 100 GHz corresponding to the axion mass.
△ Less
Submitted 28 October, 2020; v1 submitted 22 January, 2019;
originally announced January 2019.
-
Characterization of 30 $^{76}$Ge enriched Broad Energy Ge detectors for GERDA Phase II
Authors:
GERDA collaboration,
M. Agostini,
A. M. Bakalyarov,
E. Andreotti,
M. Balata,
I. Barabanov,
L. Baudis,
N. Barros,
C. Bauer,
E. Bellotti,
S. Belogurov,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
D. Borowicz,
V. Brudanin,
R. Brugnera,
D. Budjáš,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
V. D'Andrea,
E. V. Demidova,
N. Di Marco
, et al. (90 additional authors not shown)
Abstract:
The GERmanium Detector Array (GERDA) is a low background experiment located at the Laboratori Nazionali del Gran Sasso in Italy, which searches for neutrinoless double beta decay of $^{76}$Ge into $^{76}$Se+2e$^-$. GERDA has been conceived in two phases. Phase II, which started in December 2015, features several novelties including 30 new Ge detectors. These were manufactured according to the Broa…
▽ More
The GERmanium Detector Array (GERDA) is a low background experiment located at the Laboratori Nazionali del Gran Sasso in Italy, which searches for neutrinoless double beta decay of $^{76}$Ge into $^{76}$Se+2e$^-$. GERDA has been conceived in two phases. Phase II, which started in December 2015, features several novelties including 30 new Ge detectors. These were manufactured according to the Broad Energy Germanium (BEGe) detector design that has a better background discrimination capability and energy resolution compared to formerly widely-used types. Prior to their installation, the new BEGe detectors were mounted in vacuum cryostats and characterized in detail in the HADES underground laboratory in Belgium. This paper describes the properties and the overall performance of these detectors during operation in vacuum. The characterization campaign provided not only direct input for GERDA Phase II data collection and analyses, but also allowed to study detector phenomena, detector correlations as well as to test the strength of pulse shape simulation codes.
△ Less
Submitted 19 January, 2019;
originally announced January 2019.
-
Muon-induced neutrons in lead and copper at shallow depth
Authors:
R. Kneißl,
A. Caldwell,
Q. Du,
A. Empl,
C. Gooch,
X. Liu,
B. Majorovits,
M. Palermo,
O. Schulz
Abstract:
Next generation low-background experiments require a detailed understanding of all possible radiation backgrounds. One important radiation source are muon-induced neutrons. Their production processes are up to now not fully understood. New measurements with MINIDEX (Muon-Induced Neutron Indirect Detection EXperiment) of the production of neutrons by cosmogenic muons in high-Z materials are reporte…
▽ More
Next generation low-background experiments require a detailed understanding of all possible radiation backgrounds. One important radiation source are muon-induced neutrons. Their production processes are up to now not fully understood. New measurements with MINIDEX (Muon-Induced Neutron Indirect Detection EXperiment) of the production of neutrons by cosmogenic muons in high-Z materials are reported. The setup is located at the T{ü}bingen Shallow Underground Laboratory, which provides a vertical shielding depth of (13.2\,$\pm$\,0.8) meter water equivalent at the setup location. Muon-induced neutrons are identified by the detection of 2.2\,MeV gammas from their capture on hydrogen with high-purity germanium detectors.
The experimental results were compared to Geant4 Monte Carlo predictions. The measured rate of 2.2\,MeV neutron capture gammas for lead was found to be in good agreement with the Geant4 predicted rate. For copper the measured rate was found to be a factor of 0.72\,$\pm$\,0.14 lower than the Geant4 predicted rate.
An additional simulation was performed using the FLUKA Monte Carlo code. The FLUKA predicted rate of detected 2.2\,MeV neutron capture gammas for lead was also found to be in good agreement with the experimental value. A detailed comparison of muon interactions and neutron production in lead for Geant4 and FLUKA revealed large discrepancies in the description of photo-nuclear and muon-nuclear inelastic scattering reactions for muon energies at shallow underground sites. These results suggest that Geant4, when used with Geant4 recommended or standard physics lists, underpredicts the neutron production in photo-nuclear inelastic scattering reactions while at the same time it overpredicts the neutron production in muon-nuclear inelastic scattering reactions.
△ Less
Submitted 3 April, 2019; v1 submitted 16 January, 2019;
originally announced January 2019.
-
Use of polyethylene naphthalate as a self-vetoing structural material
Authors:
Y. Efremenko,
L. Fajt,
M. Febbraro,
F. Fischer,
C. Hayward,
R. Hodák,
T. Kraetzschmar,
B. Majorovits,
D. Muenstermann,
E. Öz,
R. Pjatkan,
M. Pohl,
D. Radford,
R. Rouhana,
E. Sala,
O. Schulz,
I. Štekl,
M. Stommel
Abstract:
The discovery of scintillation in the blue regime from polyethylene naphthalate (PEN), a commonly used high-performance industrial polyester plastic, has sparked considerable interest from the physics community as a new type of plastic scintillator material. This observation in addition to its good mechanical and radiopurity properties makes PEN an attractive candidate as an active structure scint…
▽ More
The discovery of scintillation in the blue regime from polyethylene naphthalate (PEN), a commonly used high-performance industrial polyester plastic, has sparked considerable interest from the physics community as a new type of plastic scintillator material. This observation in addition to its good mechanical and radiopurity properties makes PEN an attractive candidate as an active structure scintillator for low-background physics experiments. This paper reports on investigations of its potential in terms of production tests of custom made tiles and various scintillation light output measurements. These investigations substantiate the high potential of usage of PEN in low-background experiments.
△ Less
Submitted 11 June, 2019; v1 submitted 11 January, 2019;
originally announced January 2019.
-
Characterisation of an n-type segmented BEGe detector
Authors:
I. Abt,
A. Caldwell,
B. Donmez,
C. Etrillard,
C. Gooch,
L. Hauertmann,
M. O. Lampert,
H. Liao,
X. Liu,
H. Ma,
B. Majorovits,
O. Schulz,
M. Schuster
Abstract:
A four-fold segmented n-type point-contact "Broad Energy" high-purity germanium detector, SegBEGe, has been characterised at the Max-Planck-Institut für Physik in Munich. The main characteristics of the detector are described and first measurements concerning the detector properties are presented. The possibility to use mirror pulses to determine source positions is discussed as well as charge los…
▽ More
A four-fold segmented n-type point-contact "Broad Energy" high-purity germanium detector, SegBEGe, has been characterised at the Max-Planck-Institut für Physik in Munich. The main characteristics of the detector are described and first measurements concerning the detector properties are presented. The possibility to use mirror pulses to determine source positions is discussed as well as charge losses observed close to the core contact.
△ Less
Submitted 22 October, 2018;
originally announced October 2018.
-
Improved limit on neutrinoless double beta decay of $^{76}$Ge from GERDA Phase II
Authors:
M. Agostini,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
E. Bellotti,
S. Belogurov,
A. Bettini,
L. Bezrukov,
J. Biernat,
T. Bode,
D. Borowicz,
V. Brudanin,
R. Brugnera,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
T. Comellato,
V. D'Andrea,
E. V. Demidova,
N. Di Marco,
A. Domula,
E. Doroshkevich,
V. Egorov
, et al. (83 additional authors not shown)
Abstract:
The GERDA experiment searches for the lepton number violating neutrinoless double beta decay of $^{76}$Ge ($^{76}$Ge $\rightarrow$ $^{76}$Se + 2e$^-$) operating bare Ge diodes with an enriched $^{76}$Ge fraction in liquid argon. The exposure for BEGe-type detectors is increased threefold with respect to our previous data release. The BEGe detectors feature an excellent background suppression from…
▽ More
The GERDA experiment searches for the lepton number violating neutrinoless double beta decay of $^{76}$Ge ($^{76}$Ge $\rightarrow$ $^{76}$Se + 2e$^-$) operating bare Ge diodes with an enriched $^{76}$Ge fraction in liquid argon. The exposure for BEGe-type detectors is increased threefold with respect to our previous data release. The BEGe detectors feature an excellent background suppression from the analysis of the time profile of the detector signals. In the analysis window a background level of $1.0_{-0.4}^{+0.6}\cdot10^{-3}$ cts/(keV$\cdot$kg$\cdot$yr) has been achieved; if normalized to the energy resolution this is the lowest ever achieved in any 0$νββ$ experiment. No signal is observed and a new 90 \% C.L. lower limit for the half-life of $8.0\cdot10^{25}$ yr is placed when combining with our previous data. The median expected sensitivity assuming no signal is $5.8\cdot10^{25}$ yr.
△ Less
Submitted 29 March, 2018;
originally announced March 2018.
-
Direct measurement of neutrons induced in lead by cosmic muons at a shallow underground site
Authors:
Qiang Du,
Iris Abt,
Anton Empl,
Chris Gooch,
Raphael Kneissl,
Shin Ted LIN,
Bela Majorovits,
Matteo Palermo,
Oliver Schulz,
Li Wang,
Qian YUE,
Anna Julia Zsigmond
Abstract:
Neutron production in lead by cosmic muons has been studied with a Gadolinium doped liquid scintillator detector. The detector was installed next to the Muon-Induced Neutron Indirect Detection EXperiment (MINIDEX), permanently located in the Tübingen shallow underground laboratory where the mean muon energy is approximately 7 GeV. The MINIDEX plastic scintillators were used to tag muons; the neutr…
▽ More
Neutron production in lead by cosmic muons has been studied with a Gadolinium doped liquid scintillator detector. The detector was installed next to the Muon-Induced Neutron Indirect Detection EXperiment (MINIDEX), permanently located in the Tübingen shallow underground laboratory where the mean muon energy is approximately 7 GeV. The MINIDEX plastic scintillators were used to tag muons; the neutrons were detected through neutron capture and neutron-induced nuclear recoil signals in the liquid scintillator detector. Results on the rates of observed neutron captures and nuclear recoils are presented and compared to predictions from GEANT4-9.6 and GEANT4-10.3. The predicted rates are significantly too low for both versions of GEANT4. For neutron capture events, the observation exceeds the predictions by factors of $ 1.65\,\pm\,0.02\,\textrm{(stat.)}\,\pm\,0.07\,\textrm{(syst.)} $ and $ 2.58\,\pm\,0.03\,\textrm{(stat.)}\,\pm\,0.11\,\textrm{(syst.)} $ for GEANT4-9.6 and GEANT4-10.3, respectively. For neutron nuclear recoil events, which require neutron energies above approximately 5 MeV, the factors are even larger, $ 2.22\,\pm\,0.05\,\textrm{(stat.)}\,\pm\,0.25\,\textrm{(syst.)} $ and $ 3.76\,\pm\,0.09\,\textrm{(stat.)}\,\pm\,0.41\,\textrm{(syst.)} $, respectively. Also presented is the first statistically significant measurement of the spectrum of neutrons induced by cosmic muons in lead between 5 and 40 MeV. It was obtained by unfolding the nuclear recoil spectrum. The observed neutron spectrum is harder than predicted by GEANT4. An investigation of the distribution of the time difference between muon tags and nuclear recoil signals confirms the validity of the unfolding procedure and shows that GEANT4 cannot properly describe the time distribution of nuclear recoil events. In general, the description of the data is worse for GEANT4-10.3 than for GEANT4-9.6.
△ Less
Submitted 7 May, 2018; v1 submitted 15 January, 2018;
originally announced January 2018.
-
MADMAX: A new road to axion dark matter detection
Authors:
B. Majorovits
Abstract:
The axion is a hypothetical low-mass boson predicted by the Peccei-Quinn mechanism solving the strong CP problem. It is naturally also a cold dark matter candidate if its mass is below $\sim$\,1\,meV, thus simultaneously solving two major problems of nature. All existing experimental efforts to detect QCD axions focus on a range of axion masses below $\sim$\,25$\,μ$eV. The mass range above $\sim$\…
▽ More
The axion is a hypothetical low-mass boson predicted by the Peccei-Quinn mechanism solving the strong CP problem. It is naturally also a cold dark matter candidate if its mass is below $\sim$\,1\,meV, thus simultaneously solving two major problems of nature. All existing experimental efforts to detect QCD axions focus on a range of axion masses below $\sim$\,25$\,μ$eV. The mass range above $\sim$\,40$\,μ$eV, predicted by modern models in which the Peccei-Quinn symmetry was restored after inflation, could not be explored so far. The MADMAX project is designed to be sensitive for axions with masses (40--400$)\,μ$eV. The experimental design is based on the idea of enhanced axion-photon conversion in a system with several layers with alternating dielectric constants. The concept and the proposed design of the MADMAX experiment are discussed. Measurements taken with a prototype test setup are discussed. The prospects for reaching sensitivity enough to cover the parameter space predicted for QCD dark matter axions with mass in the range around 100\,$μ$eV is presented.
△ Less
Submitted 4 December, 2017;
originally announced December 2017.
-
Upgrade for Phase II of the GERDA Experiment
Authors:
M. Agostini,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
D. Borowicz,
V. Brudanin,
R. Brugnera,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
V. D'Andrea,
E. V. Demidova,
N. Di Marco,
A. Domula,
E. Doroshkevich,
V. Egorov
, et al. (89 additional authors not shown)
Abstract:
The GERDA collaboration is performing a sensitive search for neutrinoless double beta decay of $^{76}$Ge at the INFN Laboratori Nazionali del Gran Sasso, Italy. The upgrade of the GERDA experiment from Phase I to Phase II has been concluded in December 2015. The first Phase II data release shows that the goal to suppress the background by one order of magnitude compared to Phase I has been achieve…
▽ More
The GERDA collaboration is performing a sensitive search for neutrinoless double beta decay of $^{76}$Ge at the INFN Laboratori Nazionali del Gran Sasso, Italy. The upgrade of the GERDA experiment from Phase I to Phase II has been concluded in December 2015. The first Phase II data release shows that the goal to suppress the background by one order of magnitude compared to Phase I has been achieved. GERDA is thus the first experiment that will remain background-free up to its design exposure (100 kg yr). It will reach thereby a half-life sensitivity of more than 10$^{26}$ yr within 3 years of data collection. This paper describes in detail the modifications and improvements of the experimental setup for Phase II and discusses the performance of individual detector components.
△ Less
Submitted 4 November, 2017;
originally announced November 2017.
-
Searching for neutrinoless double beta decay with GERDA
Authors:
GERDA Collaboration,
M. Agostini,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
E. Bellotti,
S. Belogurov,
A. Bettini,
L. Bezrukov,
T. Bode,
V. Brudanin,
R. Brugnera,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
V. D'Andrea,
E. V. Demidova,
N. Di Marco,
A. Domula,
E. Doroshkevich,
V. Egorov,
R. Falkenstein,
A. Gangapshev
, et al. (81 additional authors not shown)
Abstract:
The GERmanium Detector Array (GERDA) experiment located at the INFN Gran Sasso Laboratory (Italy), is looking for the neutrinoless double beta decay of Ge76, by using high-purity germanium detectors made from isotopically enriched material. The combination of the novel experimental design, the careful material selection for radio-purity and the active/passive shielding techniques result in a very…
▽ More
The GERmanium Detector Array (GERDA) experiment located at the INFN Gran Sasso Laboratory (Italy), is looking for the neutrinoless double beta decay of Ge76, by using high-purity germanium detectors made from isotopically enriched material. The combination of the novel experimental design, the careful material selection for radio-purity and the active/passive shielding techniques result in a very low residual background at the Q-value of the decay, about 1e-3 counts/(keV kg yr). This makes GERDA the first experiment in the field to be background-free for the complete design exposure of 100 kg yr. A search for neutrinoless double beta decay was performed with a total exposure of 47.7 kg yr: 23.2 kg yr come from the second phase (Phase II) of the experiment, in which the background is reduced by about a factor of ten with respect to the previous phase. The analysis presented in this paper includes 12.4 kg yr of new Phase II data. No evidence for a possible signal is found: the lower limit for the half-life of Ge76 is 8.0e25 yr at 90% CL. The experimental median sensitivity is 5.8e25 yr. The experiment is currently taking data. As it is running in a background-free regime, its sensitivity grows linearly with exposure and it is expected to surpass 1e26 yr within 2018.
△ Less
Submitted 21 October, 2017;
originally announced October 2017.
-
The Large Enriched Germanium Experiment for Neutrinoless Double Beta Decay (LEGEND)
Authors:
LEGEND Collaboration,
N. Abgrall,
A. Abramov,
N. Abrosimov,
I. Abt,
M. Agostini,
M. Agartioglu,
A. Ajjaq,
S. I. Alvis,
F. T. Avignone III,
X. Bai,
M. Balata,
I. Barabanov,
A. S. Barabash,
P. J. Barton,
L. Baudis,
L. Bezrukov,
T. Bode,
A. Bolozdynya,
D. Borowicz,
A. Boston,
H. Boston,
S. T. P. Boyd,
R. Breier,
V. Brudanin
, et al. (208 additional authors not shown)
Abstract:
The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely…
▽ More
The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely low backgrounds, at the level of $\sim$0.1 count /(FWHM$\cdot$t$\cdot$yr) in the region of the signal. The current generation $^{76}$Ge experiments GERDA and the MAJORANA DEMONSTRATOR utilizing high purity Germanium detectors with an intrinsic energy resolution of 0.12%, have achieved the lowest backgrounds by over an order of magnitude in the 0$νββ$ signal region of all 0$νββ$ experiments. Building on this success, the LEGEND collaboration has been formed to pursue a tonne-scale $^{76}$Ge experiment. The collaboration aims to develop a phased 0$νββ$ experimental program with discovery potential at a half-life approaching or at $10^{28}$ years, using existing resources as appropriate to expedite physics results.
△ Less
Submitted 6 September, 2017;
originally announced September 2017.
-
PEN as self-vetoing structural Material
Authors:
B. Majorovits,
S. Eck,
F. Fischer,
C. Gooch,
C. Hayward,
T. Kraetzschmar,
N. van der Kolk,
D. Muenstermann,
O. Schulz,
F. Simon
Abstract:
Polyethylene Naphtalate (PEN) is a mechanically very favorable polymer. Earlier it was found that thin foils made from PEN can have very high radio-purity compared to other commercially available foils. In fact, PEN is already in use for low background signal transmission applications (cables). Recently it has been realized that PEN also has favorable scintillating properties. In combination, this…
▽ More
Polyethylene Naphtalate (PEN) is a mechanically very favorable polymer. Earlier it was found that thin foils made from PEN can have very high radio-purity compared to other commercially available foils. In fact, PEN is already in use for low background signal transmission applications (cables). Recently it has been realized that PEN also has favorable scintillating properties. In combination, this makes PEN a very promising candidate as a self-vetoing structural material in low background experiments. Components instrumented with light detectors could be built from PEN. This includes detector holders, detector containments, signal transmission links, etc. The current R\&D towards qualification of PEN as a self-vetoing low background structural material is be presented.
△ Less
Submitted 30 August, 2017;
originally announced August 2017.
-
Background free search for neutrinoless double beta decay with GERDA Phase II
Authors:
M. Agostini,
M. Allardt,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
D. Borowicz,
V. Brudanin,
R. Brugnera,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
V. D'Andrea,
E. V. Demidova,
N. DiMarco,
A. diVacri,
A. Domula
, et al. (91 additional authors not shown)
Abstract:
The Standard Model of particle physics cannot explain the dominance of matter over anti-matter in our Universe. In many model extensions this is a very natural consequence of neutrinos being their own anti-particles (Majorana particles) which implies that a lepton number violating radioactive decay named neutrinoless double beta ($0νββ$) decay should exist. The detection of this extremely rare hyp…
▽ More
The Standard Model of particle physics cannot explain the dominance of matter over anti-matter in our Universe. In many model extensions this is a very natural consequence of neutrinos being their own anti-particles (Majorana particles) which implies that a lepton number violating radioactive decay named neutrinoless double beta ($0νββ$) decay should exist. The detection of this extremely rare hypothetical process requires utmost suppression of any kind of backgrounds.
The GERDA collaboration searches for $0νββ$ decay of $^{76}$Ge ($^{76}\rm{Ge} \rightarrow\,^{76}\rm{Se} + 2e^-$) by operating bare detectors made from germanium with enriched $^{76}$Ge fraction in liquid argon. Here, we report on first data of GERDA Phase II. A background level of $\approx10^{-3}$ cts/(keV$\cdot$kg$\cdot$yr) has been achieved which is the world-best if weighted by the narrow energy-signal region of germanium detectors. Combining Phase I and II data we find no signal and deduce a new lower limit for the half-life of $5.3\cdot10^{25}$ yr at 90 % C.L. Our sensitivity of $4.0\cdot10^{25}$ yr is competitive with the one of experiments with significantly larger isotope mass.
GERDA is the first $0νββ$ experiment that will be background-free up to its design exposure. This progress relies on a novel active veto system, the superior germanium detector energy resolution and the improved background recognition of our new detectors. The unique discovery potential of an essentially background-free search for $0νββ$ decay motivates a larger germanium experiment with higher sensitivity.
△ Less
Submitted 5 April, 2017; v1 submitted 1 March, 2017;
originally announced March 2017.
-
Limits on uranium and thorium bulk content in GERDA Phase I detectors
Authors:
GERDA collaboration,
M. Agostini,
M. Allardt,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
N. Becerici-Schmidt,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
D. Borowicz,
V. Brudanin,
R. Brugnera,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
V. D'Andrea,
E. V. Demidova,
A. di Vacri
, et al. (91 additional authors not shown)
Abstract:
Internal contaminations of $^{238}$U, $^{235}$U and $^{232}$Th in the bulk of high purity germanium detectors are potential backgrounds for experiments searching for neutrinoless double beta decay of $^{76}$Ge. The data from GERDA Phase~I have been analyzed for alpha events from the decay chain of these contaminations by looking for full decay chains and for time correlations between successive de…
▽ More
Internal contaminations of $^{238}$U, $^{235}$U and $^{232}$Th in the bulk of high purity germanium detectors are potential backgrounds for experiments searching for neutrinoless double beta decay of $^{76}$Ge. The data from GERDA Phase~I have been analyzed for alpha events from the decay chain of these contaminations by looking for full decay chains and for time correlations between successive decays in the same detector. No candidate events for a full chain have been found. Upper limits on the activities in the range of a few nBq/kg for $^{226}$Ra, $^{227}$Ac and $^{228}$Th, the long-lived daughter nuclides of $^{238}$U, $^{235}$U and $^{232}$Th, respectively, have been derived. With these upper limits a background index in the energy region of interest from $^{226}$Ra and $^{228}$Th contamination is estimated which satisfies the prerequisites of a future ton scale germanium double beta decay experiment.
△ Less
Submitted 18 November, 2016;
originally announced November 2016.
-
Dielectric Haloscopes: A New Way to Detect Axion Dark Matter
Authors:
The MADMAX Working Group,
Allen Caldwell,
Gia Dvali,
Bela Majorovits,
Alexander Millar,
Georg Raffelt,
Javier Redondo,
Olaf Reimann,
Frank Simon,
Frank Steffen
Abstract:
We propose a new strategy to search for dark matter axions in the mass range of 40--400 $μ$eV by introducing dielectric haloscopes, which consist of dielectric disks placed in a magnetic field. The changing dielectric media cause discontinuities in the axion-induced electric field, leading to the generation of propagating electromagnetic waves to satisfy the continuity requirements at the interfac…
▽ More
We propose a new strategy to search for dark matter axions in the mass range of 40--400 $μ$eV by introducing dielectric haloscopes, which consist of dielectric disks placed in a magnetic field. The changing dielectric media cause discontinuities in the axion-induced electric field, leading to the generation of propagating electromagnetic waves to satisfy the continuity requirements at the interfaces. Large-area disks with adjustable distances boost the microwave signal (10--100 GHz) to an observable level and allow one to scan over a broad axion mass range. A sensitivity to QCD axion models is conceivable with 80 disks of 1 m$^2$ area contained in a $10$ Tesla field.
△ Less
Submitted 3 March, 2017; v1 submitted 17 November, 2016;
originally announced November 2016.
-
The Muon-Induced Neutron Indirect Detection EXperiment, MINIDEX
Authors:
I. Abt,
A. Caldwell,
C. Carissimo,
C. Gooch,
R. Kneissl,
J. Langford,
X. Liu,
B. Majorovits,
M. Palermo,
O. Schulz,
L. Vanhoefer
Abstract:
A new experiment to quantitatively measure neutrons induced by cosmic-ray muons in selected high-Z materials is introduced. The design of the Muon-Induced Neutron Indirect Detection EXperiment, MINIDEX, and the results from its first data taking period are presented as well as future plans. Neutron production in high-Z materials is of particular interest as such materials are used for shielding in…
▽ More
A new experiment to quantitatively measure neutrons induced by cosmic-ray muons in selected high-Z materials is introduced. The design of the Muon-Induced Neutron Indirect Detection EXperiment, MINIDEX, and the results from its first data taking period are presented as well as future plans. Neutron production in high-Z materials is of particular interest as such materials are used for shielding in low-background experiments. The design of next-generation large-scale experiments searching for neutrinoless double beta decay or direct interactions of dark matter requires reliable Monte Carlo simulations of background induced by muon interactions. The first five months of operation already provided a valuable data set on neutron production and neutron transport in lead. A first round of comparisons between MINIDEX data and Monte Carlo predictions obtained with two GEANT4- based packages is presented. The rate of muon-induced events is overall a factor three to four higher in data than predicted by the Monte Carlo packages. In addition, the time evolution of the muon-induced signal is not well described by the simulations.
△ Less
Submitted 5 October, 2016;
originally announced October 2016.
-
Flux Modulations seen by the Muon Veto of the GERDA Experiment
Authors:
M. Agostini,
M. Allardt,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
N. Barros,
L. Baudis,
C. Bauer,
N. Becerici-Schmidt,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
D. Borowicz,
V. Brudanin,
R. Brugnera,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
V. D'Andrea,
E. V. Demidova,
A. di Vacri
, et al. (90 additional authors not shown)
Abstract:
The GERDA experiment at LNGS of INFN is equipped with an active muon veto. The main part of the system is a water Cherenkov veto with 66~PMTs in the water tank surrounding the GERDA cryostat. The muon flux recorded by this veto shows a seasonal modulation. Two effects have been identified which are caused by secondary muons from the CNGS neutrino beam (2.2 %) and a temperature modulation of the at…
▽ More
The GERDA experiment at LNGS of INFN is equipped with an active muon veto. The main part of the system is a water Cherenkov veto with 66~PMTs in the water tank surrounding the GERDA cryostat. The muon flux recorded by this veto shows a seasonal modulation. Two effects have been identified which are caused by secondary muons from the CNGS neutrino beam (2.2 %) and a temperature modulation of the atmosphere (1.4 %). A mean cosmic muon rate of $I^0_μ = (3.477 \pm 0.002_{\textrm{stat}} \pm 0.067_{\textrm{sys}}) \times 10^{-4}$/(s$\cdot$m$^2$) was found in good agreement with other experiments at LNGS at a depth of 3500~meter water equivalent.
△ Less
Submitted 22 January, 2016;
originally announced January 2016.
-
The search for 0nbb decay with the GERDA experiment: status and prospects
Authors:
B. Majorovits
Abstract:
The GERDA experiment is designed to search for neutrinoless double beta decay of 76Ge using HPGe detectors directly immersed into liquid argon. In its first phase the GERDA experiment has yielded a half life limit on this decay of T_1/2 > 2.1*10^25 yr. A background model has been developed. It explains the measured spectrum well, taking into account only components with distances to the detectors…
▽ More
The GERDA experiment is designed to search for neutrinoless double beta decay of 76Ge using HPGe detectors directly immersed into liquid argon. In its first phase the GERDA experiment has yielded a half life limit on this decay of T_1/2 > 2.1*10^25 yr. A background model has been developed. It explains the measured spectrum well, taking into account only components with distances to the detectors less then 2 cm. Competitive limits on Majoron accompanied double beta decay have been derived. Phase II of the experiment, now with additional liquid argon veto installed, is presently starting its commissioning phase. First commissioning spectra from calibration measurements are shown, proving that the liquid argon veto leads to a significant reduction of background events.
△ Less
Submitted 1 June, 2015;
originally announced June 2015.
-
Improvement of the Energy Resolution via an Optimized Digital Signal Processing in GERDA Phase I
Authors:
M. Agostini,
M. Allardt,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
N. Barros,
L. Baudis,
C. Bauer,
N. Becerici-Schmidt,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
D. Borowicz,
V. Brudanin,
R. Brugnera,
D. Budjáš,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
V. D'Andrea,
E. V. Demidova
, et al. (89 additional authors not shown)
Abstract:
An optimized digital shaping filter has been developed for the GERDA experiment which searches for neutrinoless double beta decay in 76Ge. The GERDA Phase I energy calibration data have been reprocessed and an average improvement of 0.3 keV in energy resolution (FWHM) at the 76Ge Q value for 0νββdecay is obtained. This is possible thanks to the enhanced low-frequency noise rejection of this Zero A…
▽ More
An optimized digital shaping filter has been developed for the GERDA experiment which searches for neutrinoless double beta decay in 76Ge. The GERDA Phase I energy calibration data have been reprocessed and an average improvement of 0.3 keV in energy resolution (FWHM) at the 76Ge Q value for 0νββdecay is obtained. This is possible thanks to the enhanced low-frequency noise rejection of this Zero Area Cusp (ZAC) signal shaping fillter.
△ Less
Submitted 15 February, 2015;
originally announced February 2015.
-
Results on $ββ$ decay with emission of two neutrinos or Majorons in $^{76}$Ge from GERDA Phase I
Authors:
M. Agostini,
M. Allardt,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
N. Barros,
L. Baudis,
C. Bauer,
N. Becerici-Schmidt,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
D. Borowicz,
V. Brudanin,
R. Brugnera,
D. Budjáš,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
V. D'Andrea,
E. V. Demidova
, et al. (87 additional authors not shown)
Abstract:
A search for neutrinoless $ββ$ decay processes accompanied with Majoron emission has been performed using data collected during Phase I of the GERmanium Detector Array (GERDA) experiment at the Laboratori Nazionali del Gran Sasso of INFN (Italy). Processes with spectral indices n = 1, 2, 3, 7 were searched for. No signals were found and lower limits of the order of 10$^{23}$ yr on their half-lives…
▽ More
A search for neutrinoless $ββ$ decay processes accompanied with Majoron emission has been performed using data collected during Phase I of the GERmanium Detector Array (GERDA) experiment at the Laboratori Nazionali del Gran Sasso of INFN (Italy). Processes with spectral indices n = 1, 2, 3, 7 were searched for. No signals were found and lower limits of the order of 10$^{23}$ yr on their half-lives were derived, yielding substantially improved results compared to previous experiments with $^{76}$Ge. A new result for the half-life of the neutrino-accompanied $ββ$ decay of $^{76}$Ge with significantly reduced uncertainties is also given, resulting in $T^{2ν}_{1/2} = (1.926 \pm 0.095)\cdot10^{21}$ yr.
△ Less
Submitted 10 January, 2015;
originally announced January 2015.
-
Signal recognition efficiencies of artificial neural-network pulse-shape discrimination in HPGe $0νββ$-decay searches
Authors:
A. Caldwell,
F. Cossavella,
B. Majorovits,
D. Palioselitis,
O. Volynets
Abstract:
A pulse-shape discrimination method based on artificial neural networks was applied to pulses simulated for different background, signal and signal-like interactions inside a germanium detector. The simulated pulses were used to investigate variations of efficiencies as a function of used training set. It is verified that neural networks are well-suited to identify background pulses in true-coaxia…
▽ More
A pulse-shape discrimination method based on artificial neural networks was applied to pulses simulated for different background, signal and signal-like interactions inside a germanium detector. The simulated pulses were used to investigate variations of efficiencies as a function of used training set. It is verified that neural networks are well-suited to identify background pulses in true-coaxial high-purity germanium detectors. The systematic uncertainty on the signal recognition efficiency derived using signal-like evaluation samples from calibration measurements is estimated to be 5\%. This uncertainty is due to differences between signal and calibration samples.
△ Less
Submitted 21 July, 2015; v1 submitted 2 December, 2014;
originally announced December 2014.
-
Production, characterization and operation of $^{76}$Ge enriched BEGe detectors in GERDA
Authors:
M. Agostini,
M. Allardt,
E. Andreotti,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
N. Barros,
L. Baudis,
C. Bauer,
N. Becerici-Schmidt,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
D. Borowicz,
V. Brudanin,
R. Brugnera,
D. Budjas,
A. Caldwel,
C. Cattadori,
A. Chernogorov,
V. D'Andrea
, et al. (87 additional authors not shown)
Abstract:
The GERmanium Detector Array (GERDA) at the Gran Sasso Underground Laboratory (LNGS) searches for the neutrinoless double beta decay (0νββ) of $^{76}$Ge. Germanium detectors made of material with an enriched $^{76}$Ge fraction act simultaneously as sources and detectors for this decay.
During Phase I of the experiment mainly refurbished semi-coaxial Ge detectors from former experiments were used…
▽ More
The GERmanium Detector Array (GERDA) at the Gran Sasso Underground Laboratory (LNGS) searches for the neutrinoless double beta decay (0νββ) of $^{76}$Ge. Germanium detectors made of material with an enriched $^{76}$Ge fraction act simultaneously as sources and detectors for this decay.
During Phase I of the experiment mainly refurbished semi-coaxial Ge detectors from former experiments were used. For the upcoming Phase II, 30 new $^{76}$Ge enriched detectors of broad energy germanium (BEGe)-type were produced. A subgroup of these detectors has already been deployed in GERDA during Phase I.
The present paper reviews the complete production chain of these BEGe detectors including isotopic enrichment, purification, crystal growth and diode production. The efforts in optimizing the mass yield and in minimizing the exposure of the $^{76}$Ge enriched germanium to cosmic radiation during processing are described. Furthermore, characterization measurements in vacuum cryostats of the first subgroup of seven BEGe detectors and their long-term behavior in liquid argon are discussed. The detector performance fulfills the requirements needed for the physics goals of GERDA Phase~II.
△ Less
Submitted 3 October, 2014;
originally announced October 2014.
-
The GALATEA Test-Facility for High Purity Germanium Detectors
Authors:
I. Abt,
A. Caldwell,
B. Doenmez,
L. Garbini,
S. Irlbeck,
B. Majorovits,
M. Palermo,
O. Schulz,
H. Seitz,
F. Stelzer
Abstract:
GALATEA is a test facility designed to investigate bulk and surface effects in high purity germanium detectors. A vacuum tank houses an infrared screened volume with a cooled detector inside. A system of three stages allows an almost complete scan of the detector. The main feature of GALATEA is that there is no material between source and detector. This allows the usage of alpha and beta sources a…
▽ More
GALATEA is a test facility designed to investigate bulk and surface effects in high purity germanium detectors. A vacuum tank houses an infrared screened volume with a cooled detector inside. A system of three stages allows an almost complete scan of the detector. The main feature of GALATEA is that there is no material between source and detector. This allows the usage of alpha and beta sources as well as of a laser beam to study surface effects. A 19-fold segmented true-coaxial germanium detector was used for commissioning.
△ Less
Submitted 9 February, 2015; v1 submitted 1 September, 2014;
originally announced September 2014.
-
Pulse shape discrimination for GERDA Phase I data
Authors:
M. Agostini,
M. Allardt,
E. Andreotti,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
M. Barnabe Heider,
N. Barros,
L. Baudis,
C. Bauer,
N. Becerici-Schmidt,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
V. Brudanin,
R. Brugnera,
D. Budjáš,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
F. Cossavella
, et al. (89 additional authors not shown)
Abstract:
The GERDA experiment located at the LNGS searches for neutrinoless double beta (0νββ) decay of ^{76}Ge using germanium diodes as source and detector. In Phase I of the experiment eight semi-coaxial and five BEGe type detectors have been deployed. The latter type is used in this field of research for the first time. All detectors are made from material with enriched ^{76}Ge fraction. The experiment…
▽ More
The GERDA experiment located at the LNGS searches for neutrinoless double beta (0νββ) decay of ^{76}Ge using germanium diodes as source and detector. In Phase I of the experiment eight semi-coaxial and five BEGe type detectors have been deployed. The latter type is used in this field of research for the first time. All detectors are made from material with enriched ^{76}Ge fraction. The experimental sensitivity can be improved by analyzing the pulse shape of the detector signals with the aim to reject background events. This paper documents the algorithms developed before the data of Phase I were unblinded. The double escape peak (DEP) and Compton edge events of 2.615 MeV γ rays from ^{208}Tl decays as well as 2νββ decays of ^{76}Ge are used as proxies for 0νββ decay. For BEGe detectors the chosen selection is based on a single pulse shape parameter. It accepts 0.92$\pm$0.02 of signal-like events while about 80% of the background events at Q_{ββ}=2039 keV are rejected.
For semi-coaxial detectors three analyses are developed. The one based on an artificial neural network is used for the search of 0νββ decay. It retains 90% of DEP events and rejects about half of the events around Q_{ββ}. The 2νββ events have an efficiency of 0.85\pm0.02 and the one for 0νββ decays is estimated to be 0.90^{+0.05}_{-0.09}. A second analysis uses a likelihood approach trained on Compton edge events. The third approach uses two pulse shape parameters. The latter two methods confirm the classification of the neural network since about 90% of the data events rejected by the neural network are also removed by both of them. In general, the selection efficiency extracted from DEP events agrees well with those determined from Compton edge events or from 2νββ decays.
△ Less
Submitted 9 July, 2013;
originally announced July 2013.
-
The background in the neutrinoless double beta decay experiment GERDA
Authors:
The GERDA collaboration,
M. Agostini,
M. Allardt,
E. Andreotti,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
M. Barnabe Heider,
N. Barros,
L. Baudis,
C. Bauer,
N. Becerici-Schmidt,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
V. Brudanin,
R. Brugnera,
D. Budjas,
A. Caldwell,
C. Cattadori,
A. Chernogorov
, et al. (89 additional authors not shown)
Abstract:
The GERmanium Detector Array (GERDA) experiment at the Gran Sasso underground laboratory (LNGS) of INFN is searching for neutrinoless double beta decay of 76Ge. The signature of the signal is a monoenergetic peak at 2039 keV, the Q-value of the decay, Q_bb. To avoid bias in the signal search, the present analysis does not consider all those events, that fall in a 40 keV wide region centered around…
▽ More
The GERmanium Detector Array (GERDA) experiment at the Gran Sasso underground laboratory (LNGS) of INFN is searching for neutrinoless double beta decay of 76Ge. The signature of the signal is a monoenergetic peak at 2039 keV, the Q-value of the decay, Q_bb. To avoid bias in the signal search, the present analysis does not consider all those events, that fall in a 40 keV wide region centered around Q_bb. The main parameters needed for the neutrinoless double beta decay analysis are described. A background model was developed to describe the observed energy spectrum. The model contains several contributions, that are expected on the basis of material screening or that are established by the observation of characteristic structures in the energy spectrum. The model predicts a flat energy spectrum for the blinding window around Q_bb with a background index ranging from 17.6 to 23.8*10^{-3} counts/(keV kg yr). A part of the data not considered before has been used to test if the predictions of the background model are consistent. The observed number of events in this energy region is consistent with the background model. The background at Q-bb is dominated by close sources, mainly due to 42K, 214Bi, 228Th, 60Co and alpha emitting isotopes from the 226Ra decay chain. The individual fractions depend on the assumed locations of the contaminants. It is shown, that after removal of the known gamma peaks, the energy spectrum can be fitted in an energy range of 200 kev around Q_bb with a constant background. This gives a background index consistent with the full model and uncertainties of the same size.
△ Less
Submitted 10 April, 2014; v1 submitted 21 June, 2013;
originally announced June 2013.
-
The GERDA experiment for the search of 0νββ decay in ^{76}Ge
Authors:
GERDA Collaboration,
K. -H. Ackermann,
M. Agostini,
M. Allardt,
M. Altmann,
E. Andreotti,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
M. Barnabe Heider,
N. Barros,
L. Baudis,
C. Bauer,
N. Becerici-Schmidt,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
V. Brudanin,
R. Brugnera,
D. Budjas,
A. Caldwell
, et al. (114 additional authors not shown)
Abstract:
The GERDA collaboration is performing a search for neutrinoless double beta decay of ^{76}Ge with the eponymous detector. The experiment has been installed and commissioned at the Laboratori Nazionali del Gran Sasso and has started operation in November 2011. The design, construction and first operational results are described, along with detailed information from the R&D phase.
The GERDA collaboration is performing a search for neutrinoless double beta decay of ^{76}Ge with the eponymous detector. The experiment has been installed and commissioned at the Laboratori Nazionali del Gran Sasso and has started operation in November 2011. The design, construction and first operational results are described, along with detailed information from the R&D phase.
△ Less
Submitted 17 December, 2012;
originally announced December 2012.
-
Aluminum as a source of background in low background experiments
Authors:
B. Majorovits,
I. Abt,
M. Laubenstein,
O. Volynets
Abstract:
Neutrinoless double beta decay would be a key to understanding the nature of neutrino masses. The next generation of High Purity Germanium experiments will have to be operated with a background rate of better than 10^-5 counts/(kg y keV) in the region of interest around the Q value of the decay. Therefore, so far irrelevant sources of background have to be considered. The metalization of the surfa…
▽ More
Neutrinoless double beta decay would be a key to understanding the nature of neutrino masses. The next generation of High Purity Germanium experiments will have to be operated with a background rate of better than 10^-5 counts/(kg y keV) in the region of interest around the Q value of the decay. Therefore, so far irrelevant sources of background have to be considered. The metalization of the surface of germanium detectors is in general done with aluminum. The background from the decays of 22Na, 26Al, 226Ra and 228Th introduced by this metalization is discussed. It is shown that only a special selection of aluminum can keep these background contributions acceptable.
△ Less
Submitted 18 May, 2011;
originally announced May 2011.
-
Development of an anti-Compton veto for HPGe detectors operated in liquid argon using Silicon Photo-Multipliers
Authors:
József Janicskó Csáthy,
Hossein Aghaei Khozani,
Xiang Liu,
Béla Majorovits,
Allen Caldwell
Abstract:
A proof of concept detector is presented for scintillation light detection in liquid argon using Silicon Photo-Multipliers. The aim of the work is to build an anti-Compton veto for germanium detectors operated directly in liquid argon like in the GERDA experiment. Properties of the Multi-Pixel Photon Counter (MPPC) are studied at cryogenic temperatures. To increase the light collection efficiency…
▽ More
A proof of concept detector is presented for scintillation light detection in liquid argon using Silicon Photo-Multipliers. The aim of the work is to build an anti-Compton veto for germanium detectors operated directly in liquid argon like in the GERDA experiment. Properties of the Multi-Pixel Photon Counter (MPPC) are studied at cryogenic temperatures. To increase the light collection efficiency of the MPPCs wavelength shifting fibers were used. A veto efficiency comparable to a similar setup with a Photo-Multiplier Tube was achieved.
△ Less
Submitted 14 June, 2016; v1 submitted 11 November, 2010;
originally announced November 2010.
-
Pulse shape simulation for segmented true-coaxial HPGe detectors
Authors:
I. Abt,
A. Caldwell,
D. Lenz,
J. Liu,
X. Liu,
B. Majorovits
Abstract:
A new package to simulate the formation of electrical pulses in segmented true-coaxial high purity germanium detectors is presented. The computation of the electric field and weighting potentials inside the detector as well as of the trajectories of the charge carriers is described. In addition, the treatment of bandwidth limitations and noise are discussed. Comparison of simulated to measured pul…
▽ More
A new package to simulate the formation of electrical pulses in segmented true-coaxial high purity germanium detectors is presented. The computation of the electric field and weighting potentials inside the detector as well as of the trajectories of the charge carriers is described. In addition, the treatment of bandwidth limitations and noise are discussed. Comparison of simulated to measured pulses, obtained from an 18-fold segmented detector operated inside a cryogenic test facility, are presented.
△ Less
Submitted 6 April, 2010;
originally announced April 2010.