Intra- and Inter-Fraction Relative Range Verification in Heavy-Ion Therapy Using Filtered Interaction Vertex Imaging
Authors:
Devin Hymers,
Eva Kasanda,
Vinzenz Bildstein,
Joelle Easter,
Andrea Richard,
Artemis Spyrou,
Cornelia Höhr,
Dennis Mücher
Abstract:
Heavy-ion therapy, particularly using scanned (active) beam delivery, provides a precise and highly conformal dose distribution, with maximum dose deposition for each pencil beam at its endpoint (Bragg peak), and low entrance and exit dose. To take full advantage of this precision, robust range verification methods are required; these methods ensure that the Bragg peak is positioned correctly in t…
▽ More
Heavy-ion therapy, particularly using scanned (active) beam delivery, provides a precise and highly conformal dose distribution, with maximum dose deposition for each pencil beam at its endpoint (Bragg peak), and low entrance and exit dose. To take full advantage of this precision, robust range verification methods are required; these methods ensure that the Bragg peak is positioned correctly in the patient and the dose is delivered as prescribed. Relative range verification allows intra-fraction monitoring of Bragg peak spacing to ensure full coverage with each fraction, as well as inter-fraction monitoring to ensure all fractions are delivered consistently. To validate the proposed filtered Interaction Vertex Imaging method for relative range verification, a ${}^{16}$O beam was used to deliver 12 Bragg peak positions in a 40 mm poly-(methyl methacrylate) phantom. Secondary particles produced in the phantom were monitored using position-sensitive silicon detectors. Events recorded on these detectors, along with a measurement of the treatment beam axis, were used to reconstruct the sites of origin of these secondary particles in the phantom. The distal edge of the depth distribution of these reconstructed points was determined with logistic fits, and the translation in depth required to minimize the $χ^2$ statistic between these fits was used to compute the range shift between any two Bragg peak positions. In all cases, the range shift was determined with sub-millimeter precision, to a standard deviation of the mean of 220(10) $μ$m. This result validates filtered Interaction Vertex Imaging as a reliable relative range verification method, which should be capable of monitoring each energy step in each fraction of a scanned heavy-ion treatment plan.
△ Less
Submitted 17 December, 2021; v1 submitted 16 June, 2021;
originally announced June 2021.
-
Independent Normalization for $γ$-ray Strength Functions: The Shape Method
Authors:
M. Wiedeking,
M. Guttormsen,
A. C. Larsen,
F. Zeiser,
A. Görgen,
S. N. Liddick,
D. Mücher,
S. Siem,
A. Spyrou
Abstract:
The Shape method, a novel approach to obtain the functional form of the $γ$-ray strength function ($γ$SF) in the absence of neutron resonance spacing data, is introduced. When used in connection with the Oslo method the slope of the Nuclear Level Density (NLD) is obtained simultaneously. The foundation of the Shape method lies in the primary $γ$-ray transitions which preserve information on the fu…
▽ More
The Shape method, a novel approach to obtain the functional form of the $γ$-ray strength function ($γ$SF) in the absence of neutron resonance spacing data, is introduced. When used in connection with the Oslo method the slope of the Nuclear Level Density (NLD) is obtained simultaneously. The foundation of the Shape method lies in the primary $γ$-ray transitions which preserve information on the functional form of the $γ$SF. The Shape method has been applied to $^{56}$Fe, $^{92}$Zr, $^{164}$Dy, and $^{240}$Pu, which are representative cases for the variety of situations encountered in typical NLD and $γ$SF studies. The comparisons of results from the Shape method to those from the Oslo method demonstrate that the functional form of the $γ$SF is retained regardless of nuclear structure details or $J^π$ values of the states fed by the primary transitions.
△ Less
Submitted 24 October, 2020;
originally announced October 2020.
-
GEANT4 simulation of a new range verification method using delayed gamma spectroscopy of a Mo-92 marker
Authors:
Eva Kasanda,
Christine Burbadge,
Vinzenz Bildstein,
Josef Turko,
Artemis Spyrou,
Cornelia Höhr,
Dennis Mücher
Abstract:
In this work, we propose a novel technique for in-vivo proton therapy range verification. This technique makes use of a small hadron tumour marker, $^{92}$Mo, implanted at a short known distance from the clinical treatment volume. Signals emitted from the marker during treatment can provide a direct measurement of the proton beam energy at the marker's position. Fusion-evaporation reactions betwee…
▽ More
In this work, we propose a novel technique for in-vivo proton therapy range verification. This technique makes use of a small hadron tumour marker, $^{92}$Mo, implanted at a short known distance from the clinical treatment volume. Signals emitted from the marker during treatment can provide a direct measurement of the proton beam energy at the marker's position. Fusion-evaporation reactions between the proton beam and marker nucleus result in the emission of delayed characteristic $γ$ rays, which are detected off-beam for an improved signal-to-noise ratio. In order to determine the viability of this technique and to establish an experimental setup for future work, the Monte Carlo package GEANT4 was used in combination with ROOT to simulate a treatment scenario with the new method outlined in this work. These simulations show that analyzing the intensity of delayed $γ$ rays produced from competing reactions yields a precise measurement of the range of the proton beam relative to the marker, with sub-millimeter uncertainty.
△ Less
Submitted 2 February, 2020;
originally announced February 2020.
-
Trapped-ion decay spectroscopy towards the determination of ground-state components of double-beta decay matrix elements
Authors:
T. Brunner,
A. Lapierre,
C. Andreoiu,
M. Brodeur,
P. Delheji,
S. Ettenauer,
D. Frekers,
A. T. Gallant,
R. Gernhäuser,
A. Grossheim,
R. Krücken,
A. Lennarz,
D. Lunney,
D. Mücher,
R. Ringle,
M. C. Simon,
V. V. Simon,
S. K. L. Sjue,
K. Zuber,
J. Dilling
Abstract:
A new technique has been developed at TRIUMF's TITAN facility to perform in-trap decay spectroscopy. The aim of this technique is to eventually measure weak electron capture branching ratios (ECBRs) and by this to consequently determine GT matrix elements of $ββ$ decaying nuclei. These branching ratios provide important input to the theoretical description of these decays. The feasibility and powe…
▽ More
A new technique has been developed at TRIUMF's TITAN facility to perform in-trap decay spectroscopy. The aim of this technique is to eventually measure weak electron capture branching ratios (ECBRs) and by this to consequently determine GT matrix elements of $ββ$ decaying nuclei. These branching ratios provide important input to the theoretical description of these decays. The feasibility and power of the technique is demonstrated by measuring the ECBR of $^{124}$Cs.
△ Less
Submitted 15 October, 2013;
originally announced October 2013.