-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 10 September, 2024; v1 submitted 17 May, 2023;
originally announced May 2023.
-
A Silicon Beam Tracker
Authors:
J. H. Han,
H. S. Ahn,
J. B. Bae,
H. J. Hyun,
S. W. Jung,
D. H. Kah,
C. H. Kim,
H. J. Kim,
K. C. Kim,
M. H. Lee,
L. Lutz,
A. Malinin,
H. Park,
S. Ryu,
E. S. Seo,
P. Walpole,
J. Wu,
J. H. Yoo,
Y. S. Yoon,
S. Y. Zinn
Abstract:
When testing and calibrating particle detectors in a test beam, accurate tracking information independent of the detector being tested is extremely useful during the offline analysis of the data. A general-purpose Silicon Beam Tracker (SBT) was constructed with an active area of 32.0 x 32.0 mm2 to provide this capability for the beam calibration of the Cosmic Ray Energetics And Mass (CREAM) calori…
▽ More
When testing and calibrating particle detectors in a test beam, accurate tracking information independent of the detector being tested is extremely useful during the offline analysis of the data. A general-purpose Silicon Beam Tracker (SBT) was constructed with an active area of 32.0 x 32.0 mm2 to provide this capability for the beam calibration of the Cosmic Ray Energetics And Mass (CREAM) calorimeter. The tracker consists of two modules, each comprised of two orthogonal layers of 380 μm thick silicon strip sensors. In one module each layer is a 64-channel AC-coupled single-sided silicon strip detector (SSD) with a 0.5 mm pitch. In the other, each layer is a 32-channel DC-coupled single-sided SSD with a 1.0 mm pitch. The signals from the 4 layers are read out using modified CREAM hodoscope front-end electronics with a USB 2.0 interface board to a Linux DAQ PC. In this paper, we present the construction of the SBT, along with its performance in radioactive source tests and in a CERN beam test in October 2006.
△ Less
Submitted 23 September, 2020;
originally announced September 2020.
-
Performance of the ISS-CREAM calorimeter in a calibration beam test
Authors:
H. G. Zhang,
D. Angelaszek,
M. Copley,
J. H. Han,
H. G. Huh,
Y. S. Hwang,
H. J. Hyun,
J. A. Jeon,
K. C. Kim,
M. H. Kim,
H. J. Kim,
K. Kwashnak,
H. Y. Lee,
J. Lee,
M. H. Lee,
J. Lundquist,
L. Lutz,
A. Malinin,
H. Park,
J. M. Park,
N. Picot-Clemente,
E. S. Seo,
J. Smith,
J. Wu,
Z. Y. Yin
, et al. (1 additional authors not shown)
Abstract:
The Cosmic Ray Energetics And Mass experiment for the International Space Station (ISS-CREAM) was installed on the ISS to measure high-energy cosmic-ray elemental spectra for the charge range $\rm Z=1$ to 26. The ISS-CREAM instrument includes a tungsten scintillating-fiber calorimeter preceded by a carbon target for energy measurements. The carbon target induces hadronic interactions, and showers…
▽ More
The Cosmic Ray Energetics And Mass experiment for the International Space Station (ISS-CREAM) was installed on the ISS to measure high-energy cosmic-ray elemental spectra for the charge range $\rm Z=1$ to 26. The ISS-CREAM instrument includes a tungsten scintillating-fiber calorimeter preceded by a carbon target for energy measurements. The carbon target induces hadronic interactions, and showers of secondary particles develop in the calorimeter. The energy deposition in the calorimeter is proportional to the particle energy.
As a predecessor to ISS-CREAM, the balloon-borne CREAM instrument was successfully flown seven times over Antarctica for a cumulative exposure of 191 days. The CREAM calorimeter demonstrated its capability to measure energies of cosmic-ray particles, and the ISS-CREAM calorimeter is expected to have a similar performance. Before the launch, an engineering-unit calorimeter was shipped to CERN for calibration and performance tests. This beam test included position, energy, and angle scans of electron and pion beams together with a high-voltage scan for calibration and characterization. Additionally, an attenuation effect in the scintillating fibers was studied. In this paper, beam test results, including corrections for the attenuation effect, are presented.
△ Less
Submitted 9 June, 2021; v1 submitted 21 April, 2020;
originally announced April 2020.
-
Beam test calibration of the balloon-borne imaging calorimeter for the CREAM experiment
Authors:
P. S. Marrocchesi,
H. S. Ahn,
M. G. Bagliesi,
A. Basti,
G. Bigongiari,
A. Castellina,
M. A. Ciocci,
A. Di Virgilio,
T. Lomtatze,
O. Ganel,
K. C. Kim,
M. H. Lee,
F. Ligabue,
L. Lutz,
P. Maestro,
A. Malinine,
M. Meucci,
V. Millucci,
F. Morsani,
E. S. Seo,
R. Sina,
J. Wu,
Y. S. Yoon,
R. Zei,
S. -Y. Zinn
Abstract:
CREAM (Cosmic Ray Energetics And Mass) is a multi-flight balloon mission designed to collect direct data on the elemental composition and individual energy spectra of cosmic rays. Two instrument suites have been built to be flown alternately on a yearly base. The tungsten/Sci-Fi imaging calorimeter for the second flight, scheduled for December 2005, was calibrated with electron and proton beams…
▽ More
CREAM (Cosmic Ray Energetics And Mass) is a multi-flight balloon mission designed to collect direct data on the elemental composition and individual energy spectra of cosmic rays. Two instrument suites have been built to be flown alternately on a yearly base. The tungsten/Sci-Fi imaging calorimeter for the second flight, scheduled for December 2005, was calibrated with electron and proton beams at CERN. A calibration procedure based on the study of the longitudinal shower profile is described and preliminary results of the beam test are presented.
△ Less
Submitted 24 July, 2005;
originally announced July 2005.