-
STCF Conceptual Design Report: Volume 1 -- Physics & Detector
Authors:
M. Achasov,
X. C. Ai,
R. Aliberti,
L. P. An,
Q. An,
X. Z. Bai,
Y. Bai,
O. Bakina,
A. Barnyakov,
V. Blinov,
V. Bobrovnikov,
D. Bodrov,
A. Bogomyagkov,
A. Bondar,
I. Boyko,
Z. H. Bu,
F. M. Cai,
H. Cai,
J. J. Cao,
Q. H. Cao,
Z. Cao,
Q. Chang,
K. T. Chao,
D. Y. Chen,
H. Chen
, et al. (413 additional authors not shown)
Abstract:
The Super $τ$-Charm facility (STCF) is an electron-positron collider proposed by the Chinese particle physics community. It is designed to operate in a center-of-mass energy range from 2 to 7 GeV with a peak luminosity of $0.5\times 10^{35}{\rm cm}^{-2}{\rm s}^{-1}$ or higher. The STCF will produce a data sample about a factor of 100 larger than that by the present $τ$-Charm factory -- the BEPCII,…
▽ More
The Super $τ$-Charm facility (STCF) is an electron-positron collider proposed by the Chinese particle physics community. It is designed to operate in a center-of-mass energy range from 2 to 7 GeV with a peak luminosity of $0.5\times 10^{35}{\rm cm}^{-2}{\rm s}^{-1}$ or higher. The STCF will produce a data sample about a factor of 100 larger than that by the present $τ$-Charm factory -- the BEPCII, providing a unique platform for exploring the asymmetry of matter-antimatter (charge-parity violation), in-depth studies of the internal structure of hadrons and the nature of non-perturbative strong interactions, as well as searching for exotic hadrons and physics beyond the Standard Model. The STCF project in China is under development with an extensive R\&D program. This document presents the physics opportunities at the STCF, describes conceptual designs of the STCF detector system, and discusses future plans for detector R\&D and physics case studies.
△ Less
Submitted 5 October, 2023; v1 submitted 28 March, 2023;
originally announced March 2023.
-
Study on SiPM performance at low temperatures between $-60^{\circ}$C and $-20^{\circ}$C
Authors:
C. Zhong,
F. J. Luo,
B. Zheng,
X. D. Wang,
M. Y. Bu,
J. Zou,
M. N. Deng
Abstract:
Radon is the main background source of dark matter and neutrino experiments. Radon concentration ($\rm mBq/m^3$) measurement by liquid scintillation detector is a highly sensitive method at low temperatures using silicon photomultipliers (SiPMs) arrays. The SiPM performance characteristics are closely related to the lower detection limit of the detector. In this study, we built an automatic and ac…
▽ More
Radon is the main background source of dark matter and neutrino experiments. Radon concentration ($\rm mBq/m^3$) measurement by liquid scintillation detector is a highly sensitive method at low temperatures using silicon photomultipliers (SiPMs) arrays. The SiPM performance characteristics are closely related to the lower detection limit of the detector. In this study, we built an automatic and accurate low-temperature measurement system to study the single photoelectron spectrum, SPE resolution, optical crosstalk, and after-pulse of the SiPM at different temperatures. As a result, we obtained the variation trend of the SiPM parameters at different temperatures, and the SiPM optimal working conditions were obtained, which can improve the detector's sensitivity
△ Less
Submitted 26 October, 2022; v1 submitted 13 July, 2022;
originally announced July 2022.
-
Gain and charge response of 20 inch MCP and dynode PMTs
Authors:
H. Q. Zhang,
Z. M. Wang,
F. J. Luo,
A. B. Yang,
D. R. Wu,
Y. C. Li,
Z. H. Qin,
C. G. Yang,
Y. K. Heng,
Y. F. Wang,
H. S. Chen
Abstract:
JUNO is a 20-kton liquid scintillator detector aiming to determine the neutrino mass ordering, precisely measure the oscillation parameters, detect the astrophysical neutrinos and search for exotic physics. It is designed to reach an energy resolution of 3% at 1 MeV with the highest ever PMT coverage, using two types of 20 inch phototubes: MCP-PMT from NNVT and dynode-PMT from Hamamatsu. In this a…
▽ More
JUNO is a 20-kton liquid scintillator detector aiming to determine the neutrino mass ordering, precisely measure the oscillation parameters, detect the astrophysical neutrinos and search for exotic physics. It is designed to reach an energy resolution of 3% at 1 MeV with the highest ever PMT coverage, using two types of 20 inch phototubes: MCP-PMT from NNVT and dynode-PMT from Hamamatsu. In this article, the gain and charge response of the MCP and dynode PMTs are investigated with the study of JUNO Central Detector prototype. The linearity of the MCP-PMT charge output is measured too to check the effect of a long tail on its charge spectrum.
△ Less
Submitted 27 March, 2021;
originally announced March 2021.
-
Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector
Authors:
Daya Bay,
JUNO collaborations,
:,
A. Abusleme,
T. Adam,
S. Ahmad,
S. Aiello,
M. Akram,
N. Ali,
F. P. An,
G. P. An,
Q. An,
G. Andronico,
N. Anfimov,
V. Antonelli,
T. Antoshkina,
B. Asavapibhop,
J. P. A. M. de André,
A. Babic,
A. B. Balantekin,
W. Baldini,
M. Baldoncini,
H. R. Band,
A. Barresi,
E. Baussan
, et al. (642 additional authors not shown)
Abstract:
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were…
▽ More
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and <0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. To bridge the one order of magnitude in the detector size difference between Daya Bay and JUNO, the Daya Bay data were used to tune the parameters of a newly developed optical model. Then, the model and tuned parameters were used in the JUNO simulation. This enabled to determine the optimal composition for the JUNO LS: purified solvent LAB with 2.5 g/L PPO, and 1 to 4 mg/L bis-MSB.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
-
Comparison on PMT Waveform Reconstructions with JUNO Prototype
Authors:
H. Q. Zhang,
Z. M. Wang,
Y. P. Zhang,
Y. B. Huang,
F. J. Luo,
P. Zhang,
C. C. Zhang,
M. H. Xu,
J. C. Liu,
Y. K. Heng,
C. G. Yang,
X. S. Jiang,
F. Li,
M. Ye,
H. S. Chen
Abstract:
JUNO is proposed to determine the neutrino mass hierarchy and rich in many other neutrino topics. A prototype is designed and set up for better understanding sub-systems of future detector. The preliminary results show that its threshold reaches ~0.3MeV with trigger rate ~290 Hz on the ground with cosmic muon rate ~35 Hz. Aiming for a better detector understanding from PMT signal, three reconstruc…
▽ More
JUNO is proposed to determine the neutrino mass hierarchy and rich in many other neutrino topics. A prototype is designed and set up for better understanding sub-systems of future detector. The preliminary results show that its threshold reaches ~0.3MeV with trigger rate ~290 Hz on the ground with cosmic muon rate ~35 Hz. Aiming for a better detector understanding from PMT signal, three reconstruction algorithms are compared for PMT waveforms with different overshoot ratios, including charge integration, waveform fitting, and deconvolution. It is concluded that the three methods have similar performance on uncertainty and systematic bias while deconvolution algorithm is best to handle larger overshoot and the simplest charge integration could be considered with controlled overshoot for future fast preliminary reconstruction.
△ Less
Submitted 3 July, 2019; v1 submitted 9 May, 2019;
originally announced May 2019.
-
PMT overshoot study for JUNO prototype detector
Authors:
F. J. Luo,
Y. K. Heng,
Z. M. Wang,
P. L. Wang,
Z. H. Qin,
M. H. Xu,
D. H. Liao,
H. Q. Zhang,
X. C. Lei,
S. Qian,
S. L. Liu,
Y. B. Chen,
Y. F. Wang
Abstract:
The quality of PMT signal is one of the key items for a large and high precision neutrino experiment, like Daya Bay, JUNO, while most of the experiments are affected by the PMT signal overshoot from its positive HV-single cable scheme. For JUNO prototype detector, we have a detailed study on the PMT overshoot and successfully reduced the ratio of overshoot amplitude to signal to ~1% from previous…
▽ More
The quality of PMT signal is one of the key items for a large and high precision neutrino experiment, like Daya Bay, JUNO, while most of the experiments are affected by the PMT signal overshoot from its positive HV-single cable scheme. For JUNO prototype detector, we have a detailed study on the PMT overshoot and successfully reduced the ratio of overshoot amplitude to signal to ~1% from previous typical ~10%, with no affection to PMT other parameters. Furthermore, we calculated that the overshoot is a result of discharging of capacitors in the HV-signal splitter and the PMT voltage divider. The study result is extremely important for JUNO and other similar experiments.
△ Less
Submitted 11 May, 2016; v1 submitted 19 February, 2016;
originally announced February 2016.