Skip to main content

Showing 1–6 of 6 results for author: Luo, F J

Searching in archive physics. Search in all archives.
.
  1. arXiv:2303.15790  [pdf, other

    hep-ex hep-ph physics.ins-det

    STCF Conceptual Design Report: Volume 1 -- Physics & Detector

    Authors: M. Achasov, X. C. Ai, R. Aliberti, L. P. An, Q. An, X. Z. Bai, Y. Bai, O. Bakina, A. Barnyakov, V. Blinov, V. Bobrovnikov, D. Bodrov, A. Bogomyagkov, A. Bondar, I. Boyko, Z. H. Bu, F. M. Cai, H. Cai, J. J. Cao, Q. H. Cao, Z. Cao, Q. Chang, K. T. Chao, D. Y. Chen, H. Chen , et al. (413 additional authors not shown)

    Abstract: The Super $τ$-Charm facility (STCF) is an electron-positron collider proposed by the Chinese particle physics community. It is designed to operate in a center-of-mass energy range from 2 to 7 GeV with a peak luminosity of $0.5\times 10^{35}{\rm cm}^{-2}{\rm s}^{-1}$ or higher. The STCF will produce a data sample about a factor of 100 larger than that by the present $τ$-Charm factory -- the BEPCII,… ▽ More

    Submitted 5 October, 2023; v1 submitted 28 March, 2023; originally announced March 2023.

    Journal ref: Front. Phys. 19(1), 14701 (2024)

  2. arXiv:2207.06151  [pdf, ps, other

    physics.ins-det nucl-ex

    Study on SiPM performance at low temperatures between $-60^{\circ}$C and $-20^{\circ}$C

    Authors: C. Zhong, F. J. Luo, B. Zheng, X. D. Wang, M. Y. Bu, J. Zou, M. N. Deng

    Abstract: Radon is the main background source of dark matter and neutrino experiments. Radon concentration ($\rm mBq/m^3$) measurement by liquid scintillation detector is a highly sensitive method at low temperatures using silicon photomultipliers (SiPMs) arrays. The SiPM performance characteristics are closely related to the lower detection limit of the detector. In this study, we built an automatic and ac… ▽ More

    Submitted 26 October, 2022; v1 submitted 13 July, 2022; originally announced July 2022.

  3. arXiv:2103.14822  [pdf

    physics.ins-det hep-ex

    Gain and charge response of 20 inch MCP and dynode PMTs

    Authors: H. Q. Zhang, Z. M. Wang, F. J. Luo, A. B. Yang, D. R. Wu, Y. C. Li, Z. H. Qin, C. G. Yang, Y. K. Heng, Y. F. Wang, H. S. Chen

    Abstract: JUNO is a 20-kton liquid scintillator detector aiming to determine the neutrino mass ordering, precisely measure the oscillation parameters, detect the astrophysical neutrinos and search for exotic physics. It is designed to reach an energy resolution of 3% at 1 MeV with the highest ever PMT coverage, using two types of 20 inch phototubes: MCP-PMT from NNVT and dynode-PMT from Hamamatsu. In this a… ▽ More

    Submitted 27 March, 2021; originally announced March 2021.

  4. arXiv:2007.00314  [pdf, other

    physics.ins-det hep-ex

    Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector

    Authors: Daya Bay, JUNO collaborations, :, A. Abusleme, T. Adam, S. Ahmad, S. Aiello, M. Akram, N. Ali, F. P. An, G. P. An, Q. An, G. Andronico, N. Anfimov, V. Antonelli, T. Antoshkina, B. Asavapibhop, J. P. A. M. de André, A. Babic, A. B. Balantekin, W. Baldini, M. Baldoncini, H. R. Band, A. Barresi, E. Baussan , et al. (642 additional authors not shown)

    Abstract: To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were… ▽ More

    Submitted 1 July, 2020; originally announced July 2020.

    Comments: 13 pages, 8 figures

  5. arXiv:1905.03648  [pdf

    physics.ins-det hep-ex

    Comparison on PMT Waveform Reconstructions with JUNO Prototype

    Authors: H. Q. Zhang, Z. M. Wang, Y. P. Zhang, Y. B. Huang, F. J. Luo, P. Zhang, C. C. Zhang, M. H. Xu, J. C. Liu, Y. K. Heng, C. G. Yang, X. S. Jiang, F. Li, M. Ye, H. S. Chen

    Abstract: JUNO is proposed to determine the neutrino mass hierarchy and rich in many other neutrino topics. A prototype is designed and set up for better understanding sub-systems of future detector. The preliminary results show that its threshold reaches ~0.3MeV with trigger rate ~290 Hz on the ground with cosmic muon rate ~35 Hz. Aiming for a better detector understanding from PMT signal, three reconstruc… ▽ More

    Submitted 3 July, 2019; v1 submitted 9 May, 2019; originally announced May 2019.

  6. arXiv:1602.06080  [pdf, ps, other

    physics.ins-det hep-ex

    PMT overshoot study for JUNO prototype detector

    Authors: F. J. Luo, Y. K. Heng, Z. M. Wang, P. L. Wang, Z. H. Qin, M. H. Xu, D. H. Liao, H. Q. Zhang, X. C. Lei, S. Qian, S. L. Liu, Y. B. Chen, Y. F. Wang

    Abstract: The quality of PMT signal is one of the key items for a large and high precision neutrino experiment, like Daya Bay, JUNO, while most of the experiments are affected by the PMT signal overshoot from its positive HV-single cable scheme. For JUNO prototype detector, we have a detailed study on the PMT overshoot and successfully reduced the ratio of overshoot amplitude to signal to ~1% from previous… ▽ More

    Submitted 11 May, 2016; v1 submitted 19 February, 2016; originally announced February 2016.

    Comments: 6 pages, 11 figures