-
Optimizing SPION Labeling for Single-Cell Magnetic Microscopy
Authors:
A. Pointner,
D. Thalheim,
S. Belasi,
L. Heinen,
C. Bonato,
T. Luehmann,
J. Meijer,
R. Tietze,
C. Alexiou,
R. Schneider-Stock,
R. Nagy
Abstract:
This study explores the correlation between iron mass on cell surfaces and the resultant magnetic field. Human colorectal cancer cells (HT29 line) were labeled with varying concentrations of SPIONs and imaged via a NV center widefield magnetic microscope. To assess the labeling efficacy, a convolutional neural network trained on simulated magnetic dipole data was utilized to reconstruct key labeli…
▽ More
This study explores the correlation between iron mass on cell surfaces and the resultant magnetic field. Human colorectal cancer cells (HT29 line) were labeled with varying concentrations of SPIONs and imaged via a NV center widefield magnetic microscope. To assess the labeling efficacy, a convolutional neural network trained on simulated magnetic dipole data was utilized to reconstruct key labeling parameters on a cell-by-cell basis, including cell diameter, sensor proximity, and the iron mass associated with surface-bound SPIONs.
Our analysis provided quantitative metrics for these parameters across a range of labeling concentrations. The findings indicated that increasing SPION concentration enhances both the cell-surface iron mass and magnetic field strength, demonstrating a saturation effect. This methodology offers a coherent framework for the quantitative, high-throughput characterization of magnetically labeled cells, presenting significant implications for the fields of cell biology and magnetic sensing applications.
△ Less
Submitted 26 May, 2025;
originally announced May 2025.
-
arXiv:2501.11553
[pdf]
cs.RO
cond-mat.mtrl-sci
eess.SY
physics.app-ph
physics.bio-ph
physics.med-ph
Clinically Ready Magnetic Microrobots for Targeted Therapies
Authors:
Fabian C. Landers,
Lukas Hertle,
Vitaly Pustovalov,
Derick Sivakumaran,
Oliver Brinkmann,
Kirstin Meiners,
Pascal Theiler,
Valentin Gantenbein,
Andrea Veciana,
Michael Mattmann,
Silas Riss,
Simone Gervasoni,
Christophe Chautems,
Hao Ye,
Semih Sevim,
Andreas D. Flouris,
Josep Puigmartí-Luis,
Tiago Sotto Mayor,
Pedro Alves,
Tessa Lühmann,
Xiangzhong Chen,
Nicole Ochsenbein,
Ueli Moehrlen,
Philipp Gruber,
Miriam Weisskopf
, et al. (3 additional authors not shown)
Abstract:
Systemic drug administration often causes off-target effects limiting the efficacy of advanced therapies. Targeted drug delivery approaches increase local drug concentrations at the diseased site while minimizing systemic drug exposure. We present a magnetically guided microrobotic drug delivery system capable of precise navigation under physiological conditions. This platform integrates a clinica…
▽ More
Systemic drug administration often causes off-target effects limiting the efficacy of advanced therapies. Targeted drug delivery approaches increase local drug concentrations at the diseased site while minimizing systemic drug exposure. We present a magnetically guided microrobotic drug delivery system capable of precise navigation under physiological conditions. This platform integrates a clinical electromagnetic navigation system, a custom-designed release catheter, and a dissolvable capsule for accurate therapeutic delivery. In vitro tests showed precise navigation in human vasculature models, and in vivo experiments confirmed tracking under fluoroscopy and successful navigation in large animal models. The microrobot balances magnetic material concentration, contrast agent loading, and therapeutic drug capacity, enabling effective hosting of therapeutics despite the integration complexity of its components, offering a promising solution for precise targeted drug delivery.
△ Less
Submitted 20 January, 2025;
originally announced January 2025.
-
Spectral features of Pb-related color centers in diamond
Authors:
Sviatoslav Ditalia Tchernij,
Emilio Corte,
Tobias Lühmann,
Paolo Traina,
Sébastien Pezzagna,
Ivo Pietro Degiovanni,
Georgios Provatas,
Ekaterina Moreva,
Jan Meijer,
Paolo Olivero,
Marco Genovese,
Jacopo Forneris
Abstract:
We report on the systematic characterization of the optical properties of diamond color centers based on Pb impurities. An ensemble photoluminescence analysis of their spectral emission was performed at different excitation wavelengths in the 405-520 nm range and at different temperatures in the 4-300 K range. The series of observed spectral features consist of different emission lines associated…
▽ More
We report on the systematic characterization of the optical properties of diamond color centers based on Pb impurities. An ensemble photoluminescence analysis of their spectral emission was performed at different excitation wavelengths in the 405-520 nm range and at different temperatures in the 4-300 K range. The series of observed spectral features consist of different emission lines associated with Pb-related defects. Finally, a room-temperature investigation of single-photon emitters under 490.5 nm laser excitation is reported, revealing different spectral signatures with respect to those already reported under 514 nm excitation. This work represents a substantial progress with respect to previous studies on Pb-related color centers, both in the attribution of an articulated series of spectral features and in the understanding of the formation process of this type of defect, thus clarifying the potential of this system for high-impact applications in quantum technologies.
△ Less
Submitted 2 June, 2021;
originally announced June 2021.
-
Fluorine-based color centers in diamond
Authors:
S. Ditalia Tchernij,
T. Lühmann,
E. Corte,
F. Sardi,
F. Picollo,
P. Traina,
M. Brajkovic,
A. Crnjac,
S. Pezzagna,
I. P. Degiovanni,
E. Moreva,
P. Aprà,
P. Olivero,
Z. Siketić,
J. Meijer,
M. Genovese,
J. Forneris
Abstract:
We report on the creation and characterization of the luminescence properties of high-purity diamond substrates upon F ion implantation and subsequent thermal annealing. Their room-temperature photoluminescence emission consists of a weak emission line at 558 nm and of intense bands in the 600 - 750 nm spectral range. Characterization at liquid He temperature reveals the presence of a structured s…
▽ More
We report on the creation and characterization of the luminescence properties of high-purity diamond substrates upon F ion implantation and subsequent thermal annealing. Their room-temperature photoluminescence emission consists of a weak emission line at 558 nm and of intense bands in the 600 - 750 nm spectral range. Characterization at liquid He temperature reveals the presence of a structured set of lines in the 600 - 670 nm spectral range. We discuss the dependence of the emission properties of F-related optical centers on different experimental parameters such as the operating temperature and the excitation wavelength. The correlation of the emission intensity with F implantation fluence, and the exclusive observation of the afore-mentioned spectral features in F-implanted and annealed samples provides a strong indication that the observed emission features are related to a stable F-containing defective complex in the diamond lattice.
△ Less
Submitted 9 December, 2020; v1 submitted 28 September, 2020;
originally announced September 2020.
-
Application of SQUIDs to low temperature and high magnetic field measurements - Ultra low noise torque magnetometry
Authors:
Frank Arnold,
Marcel Naumann,
Thomas Lühmann,
Andrew P. Mackenzie,
Elena Hassinger
Abstract:
Torque magnetometry is a key method to measure the magnetic anisotropy and quantum oscillations in metals. In order to resolve quantum oscillations in sub-millimeter sized samples, piezo-electric micro-cantilevers were introduced. In the case of strongly correlated metals with large Fermi surfaces and high cyclotron masses, magnetic torque resolving powers in excess of $10^4$ are required at tempe…
▽ More
Torque magnetometry is a key method to measure the magnetic anisotropy and quantum oscillations in metals. In order to resolve quantum oscillations in sub-millimeter sized samples, piezo-electric micro-cantilevers were introduced. In the case of strongly correlated metals with large Fermi surfaces and high cyclotron masses, magnetic torque resolving powers in excess of $10^4$ are required at temperatures well below $1\,\mathrm{K}$ and magnetic fields beyond $10\,\mathrm{T}$. Here, we present a new broadband read-out scheme for piezo-electric micro-cantilevers via Wheatstone-type resistance measurements in magnetic fields up to $15\,\mathrm{T}$ and temperatures down to $100\,\mathrm{mK}$. By using a two-stage SQUID as null detector of a cold Wheatstone bridge, we were able to achieve a magnetic moment resolution of $Δm= 5\times10^{-15}\,\mathrm{J/T}$ at maximal field, outperforming conventional magnetometers by at least two orders of magnitude in this temperature and magnetic field range. Exemplary de Haas-van Alphen measurement of a newly grown delafossite, PdRhO$_2$, were used to show the superior performance of our setup.
△ Less
Submitted 7 February, 2018; v1 submitted 26 June, 2017;
originally announced June 2017.