-
2D hydrodynamic simulation of TeraFETs beyond the gradual-channel approximation for transient, large-signal or ultrahigh-frequency simulations
Authors:
Florian Ludwig,
Hartmut G. Roskos,
Raul Borsche
Abstract:
In the past decade, detection of THz radiation by plasma-wave-assisted frequency mixing in antenna-coupled field-effect transistors (TeraFETs) -- implemented in various semiconductor material systems (Si CMOS, GaN/AlGaN, GaAs/AlGaAs, graphene, etc.) -- has matured and led to a practically applied detector technology. This has been supported by the development of powerful device simulation tools wh…
▽ More
In the past decade, detection of THz radiation by plasma-wave-assisted frequency mixing in antenna-coupled field-effect transistors (TeraFETs) -- implemented in various semiconductor material systems (Si CMOS, GaN/AlGaN, GaAs/AlGaAs, graphene, etc.) -- has matured and led to a practically applied detector technology. This has been supported by the development of powerful device simulation tools which take into account relevant collective carrier dynamics and mixing processes in various approximations. These tools mostly model carrier transport in 1D and they are usually geared towards continuous-wave illumination of the device and small-signal response. Depending on their implementation, it may not be possible readily to simulate large-signal and pulsed operation. Another approximation which may lead to unsatisfactory results is the 1D restriction to calculate only the longitudinal electric field components. Especially at the edges of the gate electrode, solving of the 2D Poisson equation promises better results. This contribution introduces a stable way to solve the 2D Poisson equation self-consistently with the hydrodynamic transport equations including the numerically challenging convection term. We employ a well-balanced approximate Harten-Lax-van-Leer-Contact Riemann solver. The approach is well suited for a future treatment of transient and large-signal cases. The 2D treatment also generically extends the model beyond the gradual-channel approximation and allows to calculate the FET's response at high THz frequencies where the gate-to-channel potential acquires a non-local character. Model calculations are performed for the exemplary case of a 65-nm Si CMOS TeraFET in the isothermal approximation.
△ Less
Submitted 4 March, 2025; v1 submitted 29 May, 2024;
originally announced May 2024.
-
Modeling of antenna-coupled Si MOSFETs in the Terahertz Frequency Range
Authors:
Florian Ludwig,
Jakob Holstein,
Anastasiya Krysl,
Alvydas Lisauskas,
Hartmut G. Roskos
Abstract:
We report on the modeling and experimental characterization of Si CMOS detectors of terahertz radiation based on antenna-coupled field-effect transistors (TeraFETs). The detectors are manufactured using TSMC's 65-nm technology. We apply two models -- the TSMC RF foundry model and our own ADS-HDM -- to simulate the Si CMOS TeraFET performance and compare their predictions with respective experiment…
▽ More
We report on the modeling and experimental characterization of Si CMOS detectors of terahertz radiation based on antenna-coupled field-effect transistors (TeraFETs). The detectors are manufactured using TSMC's 65-nm technology. We apply two models -- the TSMC RF foundry model and our own ADS-HDM -- to simulate the Si CMOS TeraFET performance and compare their predictions with respective experimental data. Both models are implemented in the commercial circuit simulation software Keysight Advanced Design System (ADS). We find that the compact model TSMC RF is capable to predict the detector responsivity and its dependence on frequency and gate voltage with good accuracy up to the highest frequency of 1.2 THz covered in this study. This frequency is well beyond the tool's intended operation range for 5G communications and 110-GHz millimeter wave applications. We demonstrate that our self-developed physics-based ADS-HDM tool, which relies on an extended one-dimensional hydrodynamic transport model and can be adapted readily to other material technologies, has high predictive qualities comparable to those of the foundry model. We use the ADS-HDM to discuss the contribution of diffusive and plasmonic effects to the THz response of Si CMOS TeraFETs, finding that these effects, while becoming more significant with rising frequency, are never dominant. Finally, we estimate that the electrical NEP (perfect power coupling conditions) is on the order of 5 pW/$\sqrt{\rm{Hz}}$ at room-temperature.
△ Less
Submitted 11 April, 2024; v1 submitted 10 April, 2024;
originally announced April 2024.
-
Terahertz detection with graphene FETs: photothermoelectric and resistive self-mixing contributions to the detector response
Authors:
Florian Ludwig,
Andrey Generalov,
Jakob Holstein,
Anton Murros,
Klaara Viisanen,
Mika Prunnila,
Hartmut G. Roskos
Abstract:
Field-effect transistors coupled to integrated antennas (TeraFETs) are photodetectors being actively developed for the THz frequency range ($\sim$ 100 GHz - 10 THz). Among them, Graphene TeraFETs (G-TeraFETs) have demonstrated distinctive photoresponse features compared to those made from elementary semiconductors. For instance, previous studies have shown that G-TeraFETs exhibit a THz response th…
▽ More
Field-effect transistors coupled to integrated antennas (TeraFETs) are photodetectors being actively developed for the THz frequency range ($\sim$ 100 GHz - 10 THz). Among them, Graphene TeraFETs (G-TeraFETs) have demonstrated distinctive photoresponse features compared to those made from elementary semiconductors. For instance, previous studies have shown that G-TeraFETs exhibit a THz response that comprises two components: the resistive self-mixing (RSM) and photothermoelectric effect (PTE). The RSM and PTE arise from carrier density oscillations and carrier heating, respectively. In this work, we confirm that the photoresponse can be considered a combination of RSM and PTE, with PTE being the dominant rectification mechanism at higher frequencies. For our CVD G-TeraFETs with asymmetric antenna coupling, the PTE response dominates over the RSM at frequencies above 100 GHz. We find that relative contribution of RSM and PTE to the photoresponse is strongly frequency dependent. Electromagnetic wave simulations show that this behavior is due to the relative change in the total dissipated power between the gated and ungated channel regions of the G-TeraFET as the frequency increases. The simulations also indicate that the channel length over which the PTE contributes to the photoresponse below the gate electrode is approximately the same as the electronic cooling length. Finally, we identify a PTE contribution that can be attributed to the contact doping effect in graphene close to the metal contacts. Our detectors achieve a minimum optical noise-equivalent power of 101 (114) pW/$\sqrt{Hz}$ for asymmetric (symmetric) THz antenna coupling conditions at 400 GHz. This work demonstrates how the PTE response can be used to optimize the THz responsivity of G-TeraFETs.
△ Less
Submitted 28 March, 2024; v1 submitted 21 November, 2023;
originally announced November 2023.
-
Single Harmonic-based Narrowband Magnetic Particle Imaging
Authors:
Klaas-Julian Janssen,
Meinhard Schilling,
Frank Ludwig,
Jing Zhong
Abstract:
Visualization of the in vivo spatial distribution of superparamagnetic iron oxide nanoparticles (SPIONs) is crucial to biomedicine. Magnetic particle imaging (MPI) is one of the most promising approaches for direct measurements of the SPION distribution. In this paper, we systematically investigate a single-harmonic-based narrowband MPI approach. Herein, only the 3rd harmonic at 15 kHz of the SPIO…
▽ More
Visualization of the in vivo spatial distribution of superparamagnetic iron oxide nanoparticles (SPIONs) is crucial to biomedicine. Magnetic particle imaging (MPI) is one of the most promising approaches for direct measurements of the SPION distribution. In this paper, we systematically investigate a single-harmonic-based narrowband MPI approach. Herein, only the 3rd harmonic at 15 kHz of the SPION signal induced in an excitation magnetic field of 5 kHz is measured via a narrowband detection system for imaging during scanning a field-free-point in a field of view. Experiments on spot and line phantoms are performed to evaluate the spatial distribution by the assessment of the full width at half maximum and modulation transfer function at different excitation magnetic fields from 4 to 10 mT. Experimental results demonstrate that reconstructed images have a spatial resolution of 1.6 and 1.5 mm for a gradient field of 2.2 T/m and 4.4 T/m in x- and z-direction, respectively, at an excitation magnetic field of 4 mT. In terms of line gap, two lines with a gap of 0.5 mm are resolved. With increasing the excitation magnetic field to 10 mT, the spatial resolution gets worse to 2.4 and 2.0 mm in x- and z-direction, respectively. Moreover, the custom-built MPI scanner allows a limit of detection of 53 microgram (Fe)/mL (500 ng Fe weight) using perimag SPIONs. In addition, the excellent performance is demonstrated by imaging experiments on an "emg" logo phantom. We believe that the proposed narrowband MPI approach is a promising approach for SPION imaging.
△ Less
Submitted 22 February, 2021;
originally announced February 2021.
-
Rapid and sensitive detection of SARS-CoV-2 with functionalized magnetic nanoparticles
Authors:
Jing Zhong,
Enja Laureen Roesch,
Thilo Viereck,
Meinhard Schilling,
Frank Ludwig
Abstract:
The outbreak of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) threatens global medical systems and economies, and rules our daily living life. Controlling the outbreak of SARS-CoV-2 has become one of the most important and urgent strategies throughout the whole world. As of October, 2020, there have not yet been any medicines or therapies to be effective against SARS-CoV-2. Thus…
▽ More
The outbreak of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) threatens global medical systems and economies, and rules our daily living life. Controlling the outbreak of SARS-CoV-2 has become one of the most important and urgent strategies throughout the whole world. As of October, 2020, there have not yet been any medicines or therapies to be effective against SARS-CoV-2. Thus, rapid and sensitive diagnostics is the most important measures to control the outbreak of SARS-CoV-2. Homogeneous biosensing based on magnetic nanoparticles (MNPs) is one of the most promising approaches for rapid and highly sensitive detection of biomolecules. This paper proposes an approach for rapid and sensitive detection of SARS-CoV-2 with functionalized MNPs via the measurement of their magnetic response in an ac magnetic field. Experimental results demonstrate that the proposed approach allows the rapid detection of mimic SARS-CoV-2 with a limit of detection of 0.084 nM (5.9 fmole). The proposed approach has great potential for designing a low-cost and point-of-care device for rapid and sensitive diagnostics of SARS-CoV-2.
△ Less
Submitted 8 October, 2020;
originally announced October 2020.
-
Background in $γ$-ray detectors and carbon beam tests in the Felsenkeller shallow-underground accelerator laboratory
Authors:
T. Szücs,
D. Bemmerer,
D. Degering,
A. Domula,
M. Grieger,
F. Ludwig,
K. Schmidt,
J. Steckling,
S. Turkat,
K. Zuber
Abstract:
The relevant interaction energies for astrophysical radiative capture reactions are very low, much below the repulsive Coulomb barrier. This leads to low cross sections, low counting rates in $γ$-ray detectors, and therefore the need to perform such experiments at ion accelerators placed in underground settings, shielded from cosmic rays. Here, the feasibility of such experiments in the new shallo…
▽ More
The relevant interaction energies for astrophysical radiative capture reactions are very low, much below the repulsive Coulomb barrier. This leads to low cross sections, low counting rates in $γ$-ray detectors, and therefore the need to perform such experiments at ion accelerators placed in underground settings, shielded from cosmic rays. Here, the feasibility of such experiments in the new shallow-underground accelerator laboratory in tunnels VIII and IX of the Felsenkeller site in Dresden, Germany, is evaluated. To this end, the no-beam background in three different types of germanium detectors, i.e. a Euroball/Miniball triple cluster and two large monolithic detectors, is measured over periods of 26-66 days. The cosmic-ray induced background is found to be reduced by a factor of 500-2400, by the combined effects of, first, the 140 meters water equivalent overburden attenuating the cosmic muon flux by a factor of 40, and second, scintillation veto detectors gating out most of the remaining muon-induced effects. The new background data are compared to spectra taken with the same detectors at the Earth's surface and at other underground sites. Subsequently, the beam intensity from the cesium sputter ion source installed in Felsenkeller has been studied over periods of several hours. Based on the background and beam intensity data reported here, for the example of the $^{12}$C($α$,$γ$)$^{16}$O reaction it is shown that highly sensitive experiments will be possible.
△ Less
Submitted 23 August, 2019;
originally announced August 2019.
-
The muon intensity in the Felsenkeller shallow underground laboratory
Authors:
F. Ludwig,
L. Wagner,
T. Al-Abdullah,
G. G. Barnaföldi,
D. Bemmerer,
D. Degering,
K. Schmidt,
G. Surányi,
T. Szücs,
K. Zuber
Abstract:
The muon intensity and angular distribution in the shallow-underground laboratory Felsenkeller in Dresden, Germany have been studied using a portable muon detector based on the close cathode chamber design. Data has been taken at four positions in Felsenkeller tunnels VIII and IX, where a new 5 MV underground ion accelerator is being installed, and in addition at four positions in Felsenkeller tun…
▽ More
The muon intensity and angular distribution in the shallow-underground laboratory Felsenkeller in Dresden, Germany have been studied using a portable muon detector based on the close cathode chamber design. Data has been taken at four positions in Felsenkeller tunnels VIII and IX, where a new 5 MV underground ion accelerator is being installed, and in addition at four positions in Felsenkeller tunnel IV, which hosts a low-radioactivity counting facility. At each of the eight positions studied, seven different orientations of the detector were used to compile a map of the upper hemisphere with 0.85° angular resolution. The muon intensity is found to be suppressed by a factor of 40 due to the 45 m thick rock overburden, corresponding to 140 meters water equivalent. The angular data are matched by two different simulations taking into account the known geodetic features of the terrain: First, simply by determining the cutoff energy using the projected slant depth in rock and the known muon energy spectrum, and second, in a Geant4 simulation propagating the muons through a column of rock equal to the known slant depth. The present data are instrumental for studying muon-induced effects at these depths and also in the planning of an active veto for accelerator-based underground nuclear astrophysics experiments.
△ Less
Submitted 25 April, 2019;
originally announced April 2019.
-
The new Felsenkeller 5 MV underground accelerator
Authors:
Daniel Bemmerer,
Thomas E. Cowan,
Alexander Domula,
Toralf Döring,
Marcel Grieger,
Sebastian Hammer,
Thomas Hensel,
Lisa Hübinger,
Arnd R. Junghans,
Felix Ludwig,
Stefan E. Müller,
Stefan Reinicke,
Bernd Rimarzig,
Konrad Schmidt,
Ronald Schwengner,
Klaus Stöckel,
Tamás Szücs,
Steffen Turkat,
Andreas Wagner,
Louis Wagner,
Kai Zuber
Abstract:
The field of nuclear astrophysics is devoted to the study of the creation of the chemical elements. By nature, it is deeply intertwined with the physics of the Sun. The nuclear reactions of the proton-proton cycle of hydrogen burning, including the 3He(α,γ)7Be reaction, provide the necessary nuclear energy to prevent the gravitational collapse of the Sun and give rise to the by now well-studied pp…
▽ More
The field of nuclear astrophysics is devoted to the study of the creation of the chemical elements. By nature, it is deeply intertwined with the physics of the Sun. The nuclear reactions of the proton-proton cycle of hydrogen burning, including the 3He(α,γ)7Be reaction, provide the necessary nuclear energy to prevent the gravitational collapse of the Sun and give rise to the by now well-studied pp, 7Be, and 8B solar neutrinos. The not yet measured flux of 13N, 15O, and 17F neutrinos from the carbon-nitrogen-oxygen cycle is affected in rate by the 14N(p,γ)15O reaction and in emission profile by the 12C(p,γ)13N reaction. The nucleosynthetic output of the subsequent phase in stellar evolution, helium burning, is controlled by the 12C(α,γ)16O reaction.
In order to properly interpret the existing and upcoming solar neutrino data, precise nuclear physics information is needed. For nuclear reactions between light, stable nuclei, the best available technique are experiments with small ion accelerators in underground, low-background settings. The pioneering work in this regard has been done by the LUNA collaboration at Gran Sasso/Italy, using a 0.4 MV accelerator.
The present contribution reports on a higher-energy, 5.0 MV, underground accelerator in the Felsenkeller underground site in Dresden/Germany. Results from γ-ray, neutron, and muon background measurements in the Felsenkeller underground site in Dresden, Germany, show that the background conditions are satisfactory for nuclear astrophysics purposes. The accelerator is in the commissioning phase and will provide intense, up to 50μA, beams of 1H+, 4He+ , and 12C+ ions, enabling research on astrophysically relevant nuclear reactions with unprecedented sensitivity.
△ Less
Submitted 14 November, 2018; v1 submitted 18 October, 2018;
originally announced October 2018.
-
Phase Drift Compensating RF Link for Femtosecond Synchronization of E-XFEL
Authors:
Dominik Sikora,
Krzysztof Czuba,
Pawel Jatczak,
Maciej Urbanski,
Holger Schlarb,
Frank Ludwig,
Heinrich Pryschelski
Abstract:
Modern high-energy particle accelerators and Free-Electron Lasers incorporate large quantities of sensitive RF and microwave frequency devices distributed over kilometer distances. Such devices require extreme stable phase and time synchronization by means of high frequency signal distributed along the accelerator facility. Coaxial cables are commonly used to distribute the reference signal over t…
▽ More
Modern high-energy particle accelerators and Free-Electron Lasers incorporate large quantities of sensitive RF and microwave frequency devices distributed over kilometer distances. Such devices require extreme stable phase and time synchronization by means of high frequency signal distributed along the accelerator facility. Coaxial cables are commonly used to distribute the reference signal over the large machine to synchronize electronic systems and they are the main source of undesirable phase drifts in the synchronization system. Signal phase drifts in cables are mainly caused by temperature and humidity variations and their values usually exceed required phase synchronization accuracy by more than order of magnitude. There are several approaches to reduce signal phase drifts in coaxial cables. This paper describes the realization of active phase stabilization system based on interference phenomenon. A phase-locked signal from the transmitter is reflected at the end of a coaxial cable link. Directional couplers placed along the cable pick up the forward and reflected signals and interfere them to cancel out the cable phase drifts. Distributed hardware including interferometer controller/transmitter and receiver modules were built to demonstrate system concept and performance. Link input and output devices used FPGA I/O boards with Ethernet interface to control system operation. Specialized firmware and software was developed to calibrate and control the system. This paper describes the concept of interferometer link, designed hardware, basic control algorithms and performance evaluation results. The link prototype was built to distribute 1.3 GHz signal through a coaxial cable. Measured phase drift suppression factor value exceeded level of 100.
△ Less
Submitted 24 June, 2018;
originally announced June 2018.
-
Progress of the Felsenkeller shallow-underground accelerator for nuclear astrophysics
Authors:
D. Bemmerer,
F. Cavanna,
T. E. Cowan,
M. Grieger,
T. Hensel,
A. R. Junghans,
F. Ludwig,
S. E. Müller,
B. Rimarzig,
S. Reinicke,
S. Schulz,
R. Schwengner,
K. Stöckel,
T. Szücs,
M. P. Takács,
A. Wagner,
L. Wagner,
K. Zuber
Abstract:
Low-background experiments with stable ion beams are an important tool for putting the model of stellar hydrogen, helium, and carbon burning on a solid experimental foundation. The pioneering work in this regard has been done by the LUNA collaboration at Gran Sasso, using a 0.4 MV accelerator. In the present contribution, the status of the project for a higher-energy underground accelerator is rev…
▽ More
Low-background experiments with stable ion beams are an important tool for putting the model of stellar hydrogen, helium, and carbon burning on a solid experimental foundation. The pioneering work in this regard has been done by the LUNA collaboration at Gran Sasso, using a 0.4 MV accelerator. In the present contribution, the status of the project for a higher-energy underground accelerator is reviewed. Two tunnels of the Felsenkeller underground site in Dresden, Germany, are currently being refurbished for the installation of a 5 MV high-current Pelletron accelerator. Construction work is on schedule and expected to complete in August 2017. The accelerator will provide intense, 50 uA, beams of 1H+, 4He+, and 12C+ ions, enabling research on astrophysically relevant nuclear reactions with unprecedented sensitivity.
△ Less
Submitted 16 September, 2016;
originally announced September 2016.