-
$^{197}$Au($γ,\,xn;\,x\,=\,1\thicksim9$) Reaction Cross Section Measurements using Laser-Driven Ultra-Intense $γ$-Ray Source
Authors:
D. Wu,
H. Y. Lan,
J. Y. Zhang,
J. X. Liu,
H. G. Lu,
J. F. Lv,
X. Z. Wu,
H. Zhang,
J. Cai,
Q. Y. Ma,
Y. H. Xia,
Z. N. Wang,
M. Z. Wang,
Z. Y. Yang,
X. L. Xu,
Y. X. Geng,
Y. Y. Zhao,
C. Lin,
W. J. Ma,
J. Q. Yu,
H. R. Wang,
F. L. Liu,
C. Y. He,
B. Guo,
P. Zhu
, et al. (4 additional authors not shown)
Abstract:
We present a new method for the measurements of photonuclear reaction flux-weighted average cross sections and isomeric ratios using a laser-driven bremsstrahlung $γ$-ray source. An ultra-bright ultra-fast 60$\,\thicksim\,$250 MeV bremsstrahlung $γ$-ray source was established using the 200 TW laser facility in the Compact Laser Plasma Accelerator Laboratory, Peking University, which could cover th…
▽ More
We present a new method for the measurements of photonuclear reaction flux-weighted average cross sections and isomeric ratios using a laser-driven bremsstrahlung $γ$-ray source. An ultra-bright ultra-fast 60$\,\thicksim\,$250 MeV bremsstrahlung $γ$-ray source was established using the 200 TW laser facility in the Compact Laser Plasma Accelerator Laboratory, Peking University, which could cover the energy range from knocking out neutrons to producing pions. Stable quasi-monoenergetic electron beams were generated via laser wakefield acceleration with a charge of 300$\,\thicksim\,$600 pC per shot. The averaged $γ$-ray intensities ($\geqslant$8 MeV) were higher than 10$^{8}$ per shot and the instantaneous intensities can reach above 10$^{19}$ s$^{-1}$ with a duration time about 6.7 ps. $^{65}$Cu($γ,\,n$)$^{64}$Cu and $^{27}$Al($γ,\,x$)$^{24}$Na reactions were used as $γ$-ray flux monitors in the experiments. The flux-weighted average cross sections and isomeric ratios of $^{197}$Au($γ,\,xn;\,x\,=\,1\thicksim9$) reactions were analyzed through activation measurements. The results showed good agreement with previous works and proved this method to be accurate. The $^{197}$Au($γ,\,xn;\,x\,=\,7\thicksim\,9$) reaction cross sections were first achieved with the highest threshold energy of 71.410 MeV. Theoretical cross sections of TALYS 1.9 were calculated to compare with experiment results. This method offered a unique way of gaining insight into photonuclear reaction research, especially for short-lived isomers which extremely lack experimental data.
△ Less
Submitted 23 November, 2023; v1 submitted 28 September, 2022;
originally announced September 2022.
-
Dynamic Structured Illumination Microscopy with a Neural Space-time Model
Authors:
Ruiming Cao,
Fanglin Linda Liu,
Li-Hao Yeh,
Laura Waller
Abstract:
Structured illumination microscopy (SIM) reconstructs a super-resolved image from multiple raw images captured with different illumination patterns; hence, acquisition speed is limited, making it unsuitable for dynamic scenes. We propose a new method, Speckle Flow SIM, that uses static patterned illumination with moving samples and models the sample motion during data capture in order to reconstru…
▽ More
Structured illumination microscopy (SIM) reconstructs a super-resolved image from multiple raw images captured with different illumination patterns; hence, acquisition speed is limited, making it unsuitable for dynamic scenes. We propose a new method, Speckle Flow SIM, that uses static patterned illumination with moving samples and models the sample motion during data capture in order to reconstruct the dynamic scene with super-resolution. Speckle Flow SIM relies on sample motion to capture a sequence of raw images. The spatio-temporal relationship of the dynamic scene is modeled using a neural space-time model with coordinate-based multi-layer perceptrons (MLPs), and the motion dynamics and the super-resolved scene are jointly recovered. We validate Speckle Flow SIM for coherent imaging in simulation and build a simple, inexpensive experimental setup with off-the-shelf components. We demonstrate that Speckle Flow SIM can reconstruct a dynamic scene with deformable motion and 1.88x the diffraction-limited resolution in experiment.
△ Less
Submitted 28 July, 2022; v1 submitted 3 June, 2022;
originally announced June 2022.
-
Construction and commissioning of the collinear laser spectroscopy system at BRIF
Authors:
S. J. Wang,
X. F. Yang,
S. W. Bai,
Y. C. Liu,
P. Zhang,
Y. S. Liu,
H. R. Hu,
H. W. Li,
B. Tang,
B. Q. Cui,
C. Y. He,
X. Ma,
Q. T. Li,
J. H. Chen,
K. Ma,
L. S. Yang,
Z. Y. Hu,
W. L. Pu,
Y. Chen,
Y. F. Guo,
Z. Y. Du,
Z. Yan,
F. L. Liu,
H. R. Wang,
G. Q. Yang
, et al. (2 additional authors not shown)
Abstract:
We have constructed a collinear laser spectroscopy (CLS) system installed at the Beijing Radioactive Ion-beam Facility (BRIF), aiming to investigate the nuclear properties of unstable nuclei. The first on-line commissioning experiment of this system was performed using the continuous stable ($^{39}$K) and unstable ($^{38}$K) ion beams produced by impinging a 100-MeV proton beam on a CaO target. Hy…
▽ More
We have constructed a collinear laser spectroscopy (CLS) system installed at the Beijing Radioactive Ion-beam Facility (BRIF), aiming to investigate the nuclear properties of unstable nuclei. The first on-line commissioning experiment of this system was performed using the continuous stable ($^{39}$K) and unstable ($^{38}$K) ion beams produced by impinging a 100-MeV proton beam on a CaO target. Hyperfine structure spectra of these two isotopes are reasonably reproduced, and the extracted magnetic dipole hyperfine parameters and isotope shift agree with the literature values. The on-line experiment demonstrates the overall functioning of this CLS system, opening new opportunities for laser spectroscopy measurement of unstable isotopes at BRIF and other radioactive ion beam facilities in China.
△ Less
Submitted 11 March, 2022;
originally announced March 2022.
-
Miniscope3D: optimized single-shot miniature 3D fluorescence microscopy
Authors:
Kyrollos Yanny,
Nick Antipa,
William Liberti,
Sam Dehaeck,
Kristina Monakhova,
Fanglin Linda Liu,
Konlin Shen,
Ren Ng,
Laura Waller
Abstract:
Miniature fluorescence microscopes are a standard tool in systems biology. However, widefield miniature microscopes capture only 2D information, and modifications that enable 3D capabilities increase the size and weight and have poor resolution outside a narrow depth range. Here, we achieve the 3D capability by replacing the tube lens of a conventional 2D Miniscope with an optimized multifocal pha…
▽ More
Miniature fluorescence microscopes are a standard tool in systems biology. However, widefield miniature microscopes capture only 2D information, and modifications that enable 3D capabilities increase the size and weight and have poor resolution outside a narrow depth range. Here, we achieve the 3D capability by replacing the tube lens of a conventional 2D Miniscope with an optimized multifocal phase mask at the objective's aperture stop. Placing the phase mask at the aperture stop significantly reduces the size of the device, and varying the focal lengths enables a uniform resolution across a wide depth range. The phase mask encodes the 3D fluorescence intensity into a single 2D measurement, and the 3D volume is recovered by solving a sparsity-constrained inverse problem. We provide methods for designing and fabricating the phase mask and an efficient forward model that accounts for the field-varying aberrations in miniature objectives. We demonstrate a prototype that is 17 mm tall and weighs 2.5 grams, achieving 2.76 $μ$m lateral, and 15 $μ$m axial resolution across most of the 900x700x390 $μm^3$ volume at 40 volumes per second. The performance is validated experimentally on resolution targets, dynamic biological samples, and mouse brain tissue. Compared with existing miniature single-shot volume-capture implementations, our system is smaller and lighter and achieves a more than 2x better lateral and axial resolution throughout a 10x larger usable depth range. Our microscope design provides single-shot 3D imaging for applications where a compact platform matters, such as volumetric neural imaging in freely moving animals and 3D motion studies of dynamic samples in incubators and lab-on-a-chip devices.
△ Less
Submitted 11 October, 2020;
originally announced October 2020.
-
Fourier DiffuserScope: Single-shot 3D Fourier light field microscopy with a diffuser
Authors:
Fanglin Linda Liu,
Grace Kuo,
Nick Antipa,
Kyrollos Yanny,
Laura Waller
Abstract:
Light field microscopy (LFM) uses a microlens array (MLA) near the sensor plane of a microscope to achieve single-shot 3D imaging of a sample without any moving parts. Unfortunately, the 3D capability of LFM comes with a significant loss of lateral resolution at the focal plane. Placing the MLA near the pupil plane of the microscope, instead of the image plane, can mitigate the artifacts and provi…
▽ More
Light field microscopy (LFM) uses a microlens array (MLA) near the sensor plane of a microscope to achieve single-shot 3D imaging of a sample without any moving parts. Unfortunately, the 3D capability of LFM comes with a significant loss of lateral resolution at the focal plane. Placing the MLA near the pupil plane of the microscope, instead of the image plane, can mitigate the artifacts and provide an efficient forward model, at the expense of field-of-view (FOV). Here, we demonstrate improved resolution across a large volume with Fourier DiffuserScope, which uses a diffuser in the pupil plane to encode 3D information, then computationally reconstructs the volume by solving a sparsity-constrained inverse problem. Our diffuser consists of randomly placed microlenses with varying focal lengths; the random positions provide a larger FOV compared to a conventional MLA, and the diverse focal lengths improve the axial depth range. To predict system performance based on diffuser parameters, we for the first time establish a theoretical framework and design guidelines, which are verified by numerical simulations, then build an experimental system that achieves $< 3$ um lateral and $4$ um axial resolution over a $1000 \times 1000 \times 280$ um$^3$ volume. Our diffuser design outperforms the MLA used in LFM, providing more uniform resolution over a larger volume, both laterally and axially.
△ Less
Submitted 16 September, 2020; v1 submitted 29 June, 2020;
originally announced June 2020.
-
High contrast dual-mode optical and 13C magnetic resonance imaging in diamond particles
Authors:
X. Lv,
J. H. Walton,
E. Druga,
F. Wang,
A. Aguilar,
T. McKnelly,
R. Nazaryan,
F. L. Liu,
L. Wu,
O. Shenderova,
D. B. Vigneron,
C. A. Meriles,
J. A. Reimer,
A. Pines,
A. Ajoy
Abstract:
Multichannel imaging -- the ability to acquire images of an object through more than one imaging mode simultaneously -- has opened interesting new perspectives in areas ranging from astronomy to medicine. Visible optics and magnetic resonance imaging (MRI) offer complementary advantages of resolution, speed and depth of penetration, and as such would be attractive in combination. In this paper, we…
▽ More
Multichannel imaging -- the ability to acquire images of an object through more than one imaging mode simultaneously -- has opened interesting new perspectives in areas ranging from astronomy to medicine. Visible optics and magnetic resonance imaging (MRI) offer complementary advantages of resolution, speed and depth of penetration, and as such would be attractive in combination. In this paper, we take first steps towards marrying together optical and MR imaging in a class of biocompatible particulate materials constructed out of diamond. The particles are endowed with a high density of quantum defects (Nitrogen Vacancy centers) that under optical excitation fluoresce brightly in the visible, but also concurrently electron spin polarize. This allows the hyperpolarization of lattice 13C nuclei to make the particles over three-orders of magnitude brighter than in conventional MRI. Dual-mode optical and MR imaging permits immediate access to improvements in resolution and signal-to-noise especially in scattering environments. We highlight additional benefits in background-free imaging, demonstrating lock-in suppression by factors of 2 and 5 in optical and MR domains respectively. Ultimate limits could approach as much as two orders of magnitude in each domain. Finally, leveraging the ability of optical and MR imaging to simultaneously probe Fourier-reciprocal domains (real and k-space), we elucidate the ability to employ hybrid sub-sampling in both conjugate spaces to vastly accelerate dual-image acquisition, by as much as two orders of magnitude in practically relevant sparse-imaging scenarios. This is accompanied by a reduction in optical power by the same factor. Our work suggests interesting possibilities for the simultaneous optical and low-field MR imaging of targeted diamond nanoparticles.
△ Less
Submitted 4 April, 2021; v1 submitted 4 September, 2019;
originally announced September 2019.