-
Advanced microwave photonic waveform editing: enabling the evolution of radar systems into joint radar and spectrum sensing systems
Authors:
Chi Jiang,
Taixia Shi,
Dingding Liang,
Lei Gao,
Chulun Lin,
Yang Chen
Abstract:
In response to the urgent demand for the development of future radar application platforms from single radar functionality towards integrated multi-functional systems, we show an advanced microwave photonic waveform editing method that enables the editing of arbitrary radar waveforms, equipping them with the capability to perform spectrum sensing. This, in turn, expands single-function radar syste…
▽ More
In response to the urgent demand for the development of future radar application platforms from single radar functionality towards integrated multi-functional systems, we show an advanced microwave photonic waveform editing method that enables the editing of arbitrary radar waveforms, equipping them with the capability to perform spectrum sensing. This, in turn, expands single-function radar systems into joint radar and spectrum sensing systems. We theoretically define and calculate the accumulation function of an arbitrary waveform after passing through a specific dispersive medium, and utilize this accumulation function to further design a corresponding binary sequence for editing the waveform. After editing, the accumulation function of the edited waveform approximates that of a linearly frequency-modulated signal matching the specific dispersive medium. Thus, the edited waveform can be compressed into a narrow pulse after passing through the dispersive medium, realizing the frequency-to-time mapping for achieving frequency measurement or time-frequency analysis. The concept is verified by a simulation and an experiment. Using a dispersion compensating fiber with a total dispersion of -6817 ps/nm, arbitrary waveforms, including a 7-bit Barker phase-coded waveform, a linearly frequency-modulated waveform, a nonlinearly frequency-modulated waveform, and a waveform with an "E" time-frequency diagram, are edited and further used for microwave frequency measurement and time-frequency analysis in an ultra-wide bandwidth of 36.8 GHz. The temporal resolution and frequency resolution are 2 ns and 0.86 GHz, respectively.
△ Less
Submitted 3 June, 2025;
originally announced June 2025.
-
Accurate myocardial T1 mapping at 5T using an improved MOLLI method: A validation study
Authors:
Linqi Ge,
Yinuo Zhao,
Yubo Guo,
Yuanyuan Liu,
Yihang Zhou,
Haifeng Wang,
Dong Liang,
Hairong Zheng,
Yining Wang,
Yanjie Zhu
Abstract:
Purpose: To develop 5T-SRIS, an improved 5T myocardial T1 mapping method based on MOLLI, which addresses limitations in inversion efficiency, readout perturbations, and imperfect magnetization recovery. Methods: The proposed 5T-SRIS method is based on a modified 5-(3)-3 MOLLI sequence with ECG gating and gradient echo readout. To improve inversion efficiency at 5T, the inversion pulse was redesign…
▽ More
Purpose: To develop 5T-SRIS, an improved 5T myocardial T1 mapping method based on MOLLI, which addresses limitations in inversion efficiency, readout perturbations, and imperfect magnetization recovery. Methods: The proposed 5T-SRIS method is based on a modified 5-(3)-3 MOLLI sequence with ECG gating and gradient echo readout. To improve inversion efficiency at 5T, the inversion pulse was redesigned using adiabatic hyperbolic secant (HSn) and tangent/hyperbolic tangent (Tan/Tanh) pulses. Signal evolution was modeled recursively with inversion efficiency and a correction factor (C) to correct inversion imperfections, and T1 values were estimated via nonlinear optimization. The method was validated in phantom studies, as well as in 21 healthy volunteers and 9 patients at 5T. Results: The optimized IR pulse based on the tangent/hyperbolic tangent pulse was found to outperform the conventional hyperbolic secant IR pulse at the 5T scanner. This optimized IR pulse achieves an average inversion factor of 0.9014within a B0 range of 250Hz and a B1 range of -50% to 20%. Phantom studies show that the 5T-SRIS achieved high accuracy with errors within 5%. In vivo studies with 21 healthy volunteers, the native myocardial T1 values were 1468 ms (apex), 1514 ms (middle), and 1545 ms (base). In vivo studies with 9 heart patients, the native myocardial T1 values were 1484 ms (apex), 1532 ms (middle), and 1581 ms (base). And the post myocardial T1 values were 669 ms (apex), 698 ms (middle), and 675 ms (base). Conclusion: The 5T-SRIS technique is robust and suitable for clinical cardiac imaging. This study demonstrates its feasibility for accurate myocardial T1 mapping at 5T, despite challenges related to magnetic field inhomogeneity. Keywords: Myocardial T1 mapping, 5T, improved MOLLI, 5T-SRIS
△ Less
Submitted 11 March, 2025;
originally announced March 2025.
-
High-speed readout for direct light orbital angular momentum photodetector via photoelastic modulation
Authors:
Dehong Yang,
Chang Xu,
Jiawei Lai,
Zipu Fan,
Delang Liang,
Shiyu Wang,
Jinluo Cheng,
Dong Sun
Abstract:
Recent progress in direct photodetection of light orbital angular momentum (OAM) based on the orbital photogalvanic effect (OPGE) provides an effective way for on-chip direct electric readout of orbital angular momentum, as well as large-scale integration focal-plane array devices. However, the recognition of OAM order from photocurrent response requires the extraction of circular polarization-dep…
▽ More
Recent progress in direct photodetection of light orbital angular momentum (OAM) based on the orbital photogalvanic effect (OPGE) provides an effective way for on-chip direct electric readout of orbital angular momentum, as well as large-scale integration focal-plane array devices. However, the recognition of OAM order from photocurrent response requires the extraction of circular polarization-dependent response. To date, the operation speed of such detector is currently at the minute level and is limited by slow mechanical polarization modulation and low OAM recognition capability. In this work, we demonstrate that the operation speed can be greatly improved via electrical polarization modulation strategy with photoelasitc modulator accompanied by phase-locked readout approach with lock-in amplifier. We demonstrate an operation speed of up to 1 kHz with this new technology in the mid-infrared region (4 μm) on an OAM detector using multilayer graphene (MLG) as photosensitive material. In principle, with new modulation and readout scheme, we can potentially increase the operation speed to 50.14 kHz with a PEM that operates at a state-of-the-art speed. Our work paves the way toward high-speed operation of direct OAM detection devices based on OPGE effect and pushes such technology to a more practical stage for focal plane array applications.
△ Less
Submitted 16 January, 2025;
originally announced January 2025.
-
Myocardial T1 mapping at 5T using multi-inversion recovery real-time spoiled GRE
Authors:
Linqi Ge,
Huibin Zhu,
Yihang Zhang,
Lang Zhang,
Yihang Zhou,
Haifeng Wang,
Dong Liang,
Hairong Zheng,
Yanjie Zhu
Abstract:
Purpose: To develop an accurate myocardial T1 mapping technique at 5T using Look-Locker-based multiple inversion-recovery with the real-time spoiled gradient echo (GRE) acquisition. Methods: The proposed T1 mapping technique (mIR-rt) samples the recovery of inverted magnetization using the real-time GRE and the images captured during diastole are selected for T1 fitting. Multiple-inversion recover…
▽ More
Purpose: To develop an accurate myocardial T1 mapping technique at 5T using Look-Locker-based multiple inversion-recovery with the real-time spoiled gradient echo (GRE) acquisition. Methods: The proposed T1 mapping technique (mIR-rt) samples the recovery of inverted magnetization using the real-time GRE and the images captured during diastole are selected for T1 fitting. Multiple-inversion recoveries are employed to increase the sample size for accurate fitting. Furthermore, the inversion pulse (IR) was tailored for cardiac imaging at 5T, optimized to maximize the inversion efficiency over specified ranges of B1 and off-resonance. The T1 mapping method was validated using Bloch simulation, phantom studies, and in 16 healthy volunteers at 5T. Results: The optimized IR pulse based on the tangent/hyperbolic tangent pulse was found to outperform the conventional hyperbolic secant IR pulse within a limited peak amplitude of 10.6 μT at the 5T scanner. This optimized IR pulse achieves an average inversion factor of 0.9014 within a B0 range of +/-250Hz and a B1 range of -50% to 20%. In both simulation and phantom studies, the T1 values measured by mIR-rt closely approximate the reference T1 values, with errors less than 3%, while the conventional MOLLI sequence underestimates T1 values. The myocardial T1 values at 5T are 1553 +/- 52 ms, 1531 +/- 53 ms, and 1526 +/- 60 ms (mean +/- standard deviation) at the apex, middle, and base, respectively. Conclusion: The proposed method is feasible for myocardial T1 mapping at 5T and provides better accuracy than the conventional MOLLI sequence.
Keywords: Myocardial T1 mapping, 5T, Look-Locker
△ Less
Submitted 11 March, 2025; v1 submitted 13 January, 2025;
originally announced January 2025.
-
Scatter correction for photon-counting detector based CBCT imaging
Authors:
Xin Zhang,
Ting Su,
Jiongtao Zhu,
Hairong Zheng,
Dong Liang,
Yongshuai Ge
Abstract:
Objective: The aim of this study is to validate the effectiveness of an energy-modulated scatter correction method in suppressing scatter in photon-counting detector (PCD)-based cone beam CT (CBCT) imaging. Approach: The scatter correction method, named e-Grid, which was initially applied to dual-layer flat-panel detector (DLFPD)-based CBCT imaging, was tested for its performance in PCD-CBCT imagi…
▽ More
Objective: The aim of this study is to validate the effectiveness of an energy-modulated scatter correction method in suppressing scatter in photon-counting detector (PCD)-based cone beam CT (CBCT) imaging. Approach: The scatter correction method, named e-Grid, which was initially applied to dual-layer flat-panel detector (DLFPD)-based CBCT imaging, was tested for its performance in PCD-CBCT imaging. Benchtop PCD-CBCT imaging experiments were conducted to verify the effectiveness of the e-Grid method. Additionally, quantitative metrics were measured from these experimental results. Main results: It was found that the use of the e-Grid method could significantly eliminate cupping artifacts caused by Compton scatter in PCD-CBCT imaging. Meanwhile, its effectiveness was observed in both low- and high-energy images, as well as for objects of varying sizes. Quantitative results showed that the e-Grid method could reduce scatter artifacts by at least 71% in low-energy images and 75% in high-energy images. Significance: It was demonstrated that the scatter correction method originally applied to DLFPD-based CBCT could also perform well in PCD-CBCT, showing that the e-Grid method has great potential for application in other spectral CBCT imaging systems.
△ Less
Submitted 17 December, 2024;
originally announced December 2024.
-
Reconstructing Quantitative Cerebral Perfusion Images Directly From Measured Sinogram Data Acquired Using C-arm Cone-Beam CT
Authors:
Haotian Zhao,
Ruifeng Chen,
Jing Yan,
Juan Feng,
Jun Xiang,
Yang Chen,
Dong Liang,
Yinsheng Li
Abstract:
To shorten the door-to-puncture time for better treating patients with acute ischemic stroke, it is highly desired to obtain quantitative cerebral perfusion images using C-arm cone-beam computed tomography (CBCT) equipped in the interventional suite. However, limited by the slow gantry rotation speed, the temporal resolution and temporal sampling density of typical C-arm CBCT are much poorer than…
▽ More
To shorten the door-to-puncture time for better treating patients with acute ischemic stroke, it is highly desired to obtain quantitative cerebral perfusion images using C-arm cone-beam computed tomography (CBCT) equipped in the interventional suite. However, limited by the slow gantry rotation speed, the temporal resolution and temporal sampling density of typical C-arm CBCT are much poorer than those of multi-detector-row CT in the diagnostic imaging suite. The current quantitative perfusion imaging includes two cascaded steps: time-resolved image reconstruction and perfusion parametric estimation. For time-resolved image reconstruction, the technical challenge imposed by poor temporal resolution and poor sampling density causes inaccurate quantification of the temporal variation of cerebral artery and tissue attenuation values. For perfusion parametric estimation, it remains a technical challenge to appropriately design the handcrafted regularization for better solving the associated deconvolution problem. These two challenges together prevent obtaining quantitatively accurate perfusion images using C-arm CBCT. The purpose of this work is to simultaneously address these two challenges by combining the two cascaded steps into a single joint optimization problem and reconstructing quantitative perfusion images directly from the measured sinogram data. In the developed direct cerebral perfusion parametric image reconstruction technique, TRAINER in short, the quantitative perfusion images have been represented as a subject-specific conditional generative model trained under the constraint of the time-resolved CT forward model, perfusion convolutional model, and the subject's own measured sinogram data. Results shown in this paper demonstrated that using TRAINER, quantitative cerebral perfusion images can be accurately obtained using C-arm CBCT in the interventional suite.
△ Less
Submitted 24 December, 2024; v1 submitted 6 December, 2024;
originally announced December 2024.
-
Scaling Particle Collision Data Analysis
Authors:
Hengkui Wu,
Panpan Chi,
Yongfeng Zhu,
Liujiang Liu,
Shuyang Hu,
Yuexin Wang,
Chen Zhou,
Qihao Wang,
Yingsi Xin,
Bruce Liu,
Dahao Liang,
Xinglong Jia,
Manqi Ruan
Abstract:
For decades, researchers have developed task-specific models to address scientific challenges across diverse disciplines. Recently, large language models (LLMs) have shown enormous capabilities in handling general tasks; however, these models encounter difficulties in addressing real-world scientific problems, particularly in domains involving large-scale numerical data analysis, such as experimen…
▽ More
For decades, researchers have developed task-specific models to address scientific challenges across diverse disciplines. Recently, large language models (LLMs) have shown enormous capabilities in handling general tasks; however, these models encounter difficulties in addressing real-world scientific problems, particularly in domains involving large-scale numerical data analysis, such as experimental high energy physics. This limitation is primarily due to BPE tokenization's inefficacy with numerical data. In this paper, we propose a task-agnostic architecture, BBT-Neutron, which employs a binary tokenization method to facilitate pretraining on a mixture of textual and large-scale numerical experimental data. We demonstrate the application of BBT-Neutron to Jet Origin Identification (JoI), a critical categorization challenge in high-energy physics that distinguishes jets originating from various quarks or gluons. Our results indicate that BBT-Neutron achieves comparable performance to state-of-the-art task-specific JoI models. Furthermore, we examine the scaling behavior of BBT-Neutron's performance with increasing data volume, suggesting the potential for BBT-Neutron to serve as a foundational model for particle physics data analysis, with possible extensions to a broad spectrum of scientific computing applications for Big Science experiments, industrial manufacturing and spacial computing. The project code is available at https://github.com/supersymmetry-technologies/bbt-neutron.
△ Less
Submitted 9 December, 2024; v1 submitted 28 November, 2024;
originally announced December 2024.
-
Sequential-Scanning Dual-Energy CT Imaging Using High Temporal Resolution Image Reconstruction and Error-Compensated Material Basis Image Generation
Authors:
Qiaoxin Li,
Ruifeng Chen,
Peng Wang,
Guotao Quan,
Yanfeng Du,
Dong Liang,
Yinsheng Li
Abstract:
Dual-energy computed tomography (DECT) has been widely used to obtain quantitative elemental composition of imaged subjects for personalized and precise medical diagnosis. Compared with DECT leveraging advanced X-ray source and/or detector technologies, the use of the sequential-scanning data acquisition scheme to implement DECT may make a broader impact on clinical practice because this scheme re…
▽ More
Dual-energy computed tomography (DECT) has been widely used to obtain quantitative elemental composition of imaged subjects for personalized and precise medical diagnosis. Compared with DECT leveraging advanced X-ray source and/or detector technologies, the use of the sequential-scanning data acquisition scheme to implement DECT may make a broader impact on clinical practice because this scheme requires no specialized hardware designs and can be directly implemented into conventional CT systems. However, since the concentration of iodinated contrast agent in the imaged subject varies over time, sequentially scanned data sets acquired at two tube potentials are temporally inconsistent. As existing material basis image reconstruction approaches assume that the data sets acquired at two tube potentials are temporally consistent, the violation of this assumption results in inaccurate quantification of material concentration. In this work, we developed sequential-scanning DECT imaging using high temporal resolution image reconstruction and error-compensated material basis image generation, ACCELERATION in short, to address the technical challenge induced by temporal inconsistency of sequentially scanned data sets and improve quantification accuracy of material concentration in sequential-scanning DECT. ACCELERATION has been validated and evaluated using numerical simulation data sets generated from clinical human subject exams and experimental human subject studies. Results demonstrated the improvement of quantification accuracy and image quality using ACCELERATION.
△ Less
Submitted 26 August, 2024;
originally announced August 2024.
-
ACCELERATION: Sequentially-scanning DECT Imaging Using High Temporal Resolution Image Reconstruction And Temporal Extrapolation
Authors:
Qiaoxin Li,
Dong Liang,
Yinsheng Li
Abstract:
Dual-energy computed tomography (DECT) has been widely used to obtain quantitative elemental composition of imaged subjects for personalized and precise medical diagnosis. Compared with existing high-end DECT leveraging advanced X-ray source and/or detector technologies, the use of the sequentially-scanning data acquisition scheme to implement DECT may make broader impact on clinical practice beca…
▽ More
Dual-energy computed tomography (DECT) has been widely used to obtain quantitative elemental composition of imaged subjects for personalized and precise medical diagnosis. Compared with existing high-end DECT leveraging advanced X-ray source and/or detector technologies, the use of the sequentially-scanning data acquisition scheme to implement DECT may make broader impact on clinical practice because this scheme requires no specialized hardware designs. However, since the concentration of iodinated contrast agent in the imaged subject varies over time, sequentially-scanned data sets acquired at two tube potentials are temporally inconsistent. As existing material decomposition approaches for DECT assume that the data sets acquired at two tube potentials are temporally consistent, the violation of this assumption results in inaccurate quantification accuracy of iodine concentration. In this work, we developed a technique to achieve sequentially-scanning DECT imaging using high temporal resolution image reconstruction and temporal extrapolation, ACCELERATION in short, to address the technical challenge induced by temporal inconsistency of sequentially-scanned data sets and improve iodine quantification accuracy in sequentially-scanning DECT. ACCELERATION has been validated and evaluated using numerical simulation data sets generated from clinical human subject exams. Results demonstrated the improvement of iodine quantification accuracy using ACCELERATION.
△ Less
Submitted 12 August, 2024;
originally announced August 2024.
-
CBCT scatter correction with dual-layer flat-panel detector
Authors:
Xin Zhang,
Jixiong Xie,
Ting Su,
Jiongtao Zhu,
Han Cui,
Yuhang Tan,
Dongmei Xia,
Hairong Zheng,
Dong Liang,
Yongshuai Ge
Abstract:
Background: Recently, the popularity of dual-layer flat-panel detector (DL-FPD) based dual-energy cone-beam CT (DE-CBCT) imaging has been increasing. However, the image quality of DE-CBCT remains constrained by the Compton scattered X-ray photons.
Purpose: The objective of this study is to develop an energy-modulated scatter correction method for DL-FPD based CBCT imaging.
Methods: In DL-FPD,…
▽ More
Background: Recently, the popularity of dual-layer flat-panel detector (DL-FPD) based dual-energy cone-beam CT (DE-CBCT) imaging has been increasing. However, the image quality of DE-CBCT remains constrained by the Compton scattered X-ray photons.
Purpose: The objective of this study is to develop an energy-modulated scatter correction method for DL-FPD based CBCT imaging.
Methods: In DL-FPD, a certain portion of the X-ray photons (mainly low-energy primary and scattered photons) passing through the object are captured by the top detector layer, while the remaining X-ray photons (mainly high-energy primary and scattered photons) are collected by the bottom detector layer. Based on the two set of distinct low-energy and high-energy measurements, a linear signal model was approximated for the dual-energy primary and scattered signals on DL-FPD. The distributions of X-ray scatters were quickly estimated using this signal model. Monte Carlo (MC) simulation of a water phantom was conducted to verify this newly developed scatter estimation method. Moreover, physical experiments of water phantom, head phantom, and abdominal phantom were carried out to validate the real performance of this proposed scatter correction method.
Results: The MC results showed that the e-Grid method was able to generate scatter distributions close to the ground truth. Moreover, the physical experiments demonstrated that the e-Grid method can greatly reduce the shading artifacts in both low-energy and high-energy CBCT images acquired from DL-FPD. On average, the image non-uniformity (NU) was reduced by over 77% in the low-energy CBCT image and by over 66% in the high-energy CBCT image. A a consequence, the accuracy of the decomposed multi-material bases was substantially improved.
△ Less
Submitted 27 October, 2024; v1 submitted 9 August, 2024;
originally announced August 2024.
-
A microwave photonic prototype for concurrent radar detection and spectrum sensing over an 8 to 40 GHz bandwidth
Authors:
Taixia Shi,
Dingding Liang,
Lu Wang,
Lin Li,
Shaogang Guo,
Jiawei Gao,
Xiaowei Li,
Chulun Lin,
Lei Shi,
Baogang Ding,
Shiyang Liu,
Fangyi Yang,
Chi Jiang,
Yang Chen
Abstract:
In this work, a microwave photonic prototype for concurrent radar detection and spectrum sensing is proposed, designed, built, and investigated. A direct digital synthesizer and an analog electronic circuit are integrated to generate an intermediate frequency (IF) linearly frequency-modulated (LFM) signal with a tunable center frequency from 2.5 to 9.5 GHz and an instantaneous bandwidth of 1 GHz.…
▽ More
In this work, a microwave photonic prototype for concurrent radar detection and spectrum sensing is proposed, designed, built, and investigated. A direct digital synthesizer and an analog electronic circuit are integrated to generate an intermediate frequency (IF) linearly frequency-modulated (LFM) signal with a tunable center frequency from 2.5 to 9.5 GHz and an instantaneous bandwidth of 1 GHz. The IF LFM signal is converted to the optical domain via an intensity modulator and then filtered by a fiber Bragg grating (FBG) to generate only two 2nd-order optical LFM sidebands. In radar detection, the two optical LFM sidebands beat with each other to generate a frequency-and-bandwidth-quadrupled LFM signal, which is used for ranging, radial velocity measurement, and imaging. By changing the center frequency of the IF LFM signal, the radar function can be operated within 8 to 40 GHz. In spectrum sensing, one 2nd-order optical LFM sideband is selected by another FBG, which then works in conjunction with the stimulated Brillouin scattering gain spectrum to map the frequency of the signal under test to time with an instantaneous measurement bandwidth of 2 GHz. By using a frequency shift module to adjust the pump frequency, the frequency measurement range can be adjusted from 0 to 40 GHz. The prototype is comprehensively studied and tested, which is capable of achieving a range resolution of 3.75 cm, a range error of less than $\pm$ 2 cm, a radial velocity error within $\pm$ 1 cm/s, delivering clear imaging of multiple small targets, and maintaining a frequency measurement error of less than $\pm$ 7 MHz and a frequency resolution of better than 20 MHz.
△ Less
Submitted 20 June, 2024;
originally announced June 2024.
-
Seamless Integration and Implementation of Distributed Contact and Contactless Vital Sign Monitoring
Authors:
Dingding Liang,
Yang Chen,
Jiawei Gao,
Taixia Shi,
Jianping Yao
Abstract:
Real-time vital sign monitoring is gaining immense significance not only in the medical field but also in personal health management. Facing the needs of different application scenarios of the smart and healthy city in the future, the low-cost, large-scale, scalable, and distributed vital sign monitoring system is of great significance. In this work, a seamlessly integrated contact and contactless…
▽ More
Real-time vital sign monitoring is gaining immense significance not only in the medical field but also in personal health management. Facing the needs of different application scenarios of the smart and healthy city in the future, the low-cost, large-scale, scalable, and distributed vital sign monitoring system is of great significance. In this work, a seamlessly integrated contact and contactless vital sign monitoring system, which can simultaneously implement respiration and heartbeat monitoring, is proposed. In contact vital sign monitoring, the chest wall movement due to respiration and heartbeat is translated into changes in the optical output intensity of a fiber Bragg grating (FBG). The FBG is also an important part of radar signal generation for contactless vital sign monitoring, in which the chest wall movement is translated into phase changes of the radar de-chirped signal. By analyzing the intensity of the FBG output and phase of the radar de-chirped signal, real-time respiration and heartbeat monitoring are realized. In addition, due to the distributed structure of the system and its good integration with the wavelength-division multiplexing optical network, it can be massively scaled by employing more wavelengths. A proof-of-concept experiment is carried out. Contact and contactless respiration and heartbeat monitoring of three people are simultaneously realized. During a monitoring time of 60 s, the maximum absolute measurement errors of respiration and heartbeat rates are 1.6 respirations per minute and 2.3 beats per minute, respectively. The measurement error does not have an obvious change even when the monitoring time is decreased to 5 s.
△ Less
Submitted 24 May, 2024;
originally announced May 2024.
-
Explanations of MTF discrepancy in grating-based X-ray differential phase contrast CT imaging
Authors:
Yuhang Tan,
Jiecheng Yang,
Hairong Zheng,
Dong Liang,
Peiping Zhu,
Yongshuai Ge
Abstract:
As a multi-contrast X-ray computed tomography (CT) imaging system, the grating-based Talbot-Lau interferometer is able to generate the absorption contrast and differential phase contrast (DPC) images concurrently. However, experiments found that the absorption CT (ACT) images have better spatial resolution, i.e., higher modulation transfer function (MTF), than the differential phase contrast CT (D…
▽ More
As a multi-contrast X-ray computed tomography (CT) imaging system, the grating-based Talbot-Lau interferometer is able to generate the absorption contrast and differential phase contrast (DPC) images concurrently. However, experiments found that the absorption CT (ACT) images have better spatial resolution, i.e., higher modulation transfer function (MTF), than the differential phase contrast CT (DPCT) images. Until now, the root cause of such observed discrepancy has not been rigorously investigated. Through physical experiments, this study revealed that the phase grating in the Talbot-Lau interferometer induces direct superposition of paired split absorption signals and inverse superposition of paired split phase signals via diffraction. Further simulation experiments demonstrated that this splitting leads to a reduction in MTF in both ACT and DPCT images, with distinct superposition mechanisms contributing to the lower MTF in DPCT. Besides, such MTF discrepancy may also be affected in a minor extent by object composition, sample size, beam spectra and detector pixel size. Based on this study, the spatial resolution could be optimized when designing a grating-based DPC imaging system.
△ Less
Submitted 12 April, 2024;
originally announced April 2024.
-
Heterogeneously Integrated Memristive Laser on Silicon with Non-Volatile Wavelength Tuning
Authors:
Bassem Tossoun,
Di Liang,
Xia Sheng,
John Paul Strachan,
Raymond G. Beausoleil
Abstract:
The von-Neumann bottleneck has constrained computing systems from efficiently operating on the increasingly large demand in data from networks and devices. Silicon (Si) photonics offers a powerful solution for this issue by providing a platform for high-bandwidth, energy-efficient interconnects. Furthermore, memristors have emerged as a fundamental building block for non-volatile data storage and…
▽ More
The von-Neumann bottleneck has constrained computing systems from efficiently operating on the increasingly large demand in data from networks and devices. Silicon (Si) photonics offers a powerful solution for this issue by providing a platform for high-bandwidth, energy-efficient interconnects. Furthermore, memristors have emerged as a fundamental building block for non-volatile data storage and novel computing architectures with powerful in-memory processing capabilities. In this paper, we integrate an Al2O3 memristor into a heterogeneous Si quantum dot microring laser to demonstrate the first laser with non-volatile optical memory. The memristor alters the effective optical modal index of the microring laser cavity by the plasma dispersion effect in the high resistance state (HRS) or Joule heating in the low resistance state (LRS), subsequently controlling the output wavelength of the laser in a non-volatile manner. This device enables a novel pathway for future optoelectronic neuromorphic computers and optical memory chips.
△ Less
Submitted 25 January, 2025; v1 submitted 24 January, 2024;
originally announced January 2024.
-
Silicon Optical Memory: Non-Volatile Optoelectronic Devices via Si-SiO$_2$ Hysteresis Effect
Authors:
Yuan Yuan,
Yiwei Peng,
Stanley Cheung,
Wayne V. Sorin,
Zhihong Huang,
Di Liang,
Marco Fiorentino,
Raymond G. Beausoleil
Abstract:
Implementing on-chip non-volatile optical memories has long been an actively pursued goal, promising significant enhancements in the capability and energy efficiency of photonic integrated circuits. Here, a novel optical memory has been demonstrated exclusively using the semiconductor primary material, silicon. By manipulating the optoelectronic effect of this device, we introduce a hysteresis eff…
▽ More
Implementing on-chip non-volatile optical memories has long been an actively pursued goal, promising significant enhancements in the capability and energy efficiency of photonic integrated circuits. Here, a novel optical memory has been demonstrated exclusively using the semiconductor primary material, silicon. By manipulating the optoelectronic effect of this device, we introduce a hysteresis effect at the silicon-silicon oxide interface, which in turn demonstrates multi-level, non-volatile optical data storage with robust retention and endurance. This new silicon optical memory provides a distinctively simple and accessible route to realize optical data storage in standard silicon foundry processes.
△ Less
Submitted 7 January, 2024;
originally announced January 2024.
-
Optical wood with switchable solar transmittance for all-round thermal management
Authors:
He Gao,
Ying Li,
Yanjun Xie,
Daxin Liang,
Jian Li,
Yonggui Wang,
Zefang Xiao,
Haigang Wang,
Wentao Gan,
Lorenzo Pattelli,
Hongbo Xu
Abstract:
Technologies enabling passive daytime radiative cooling and daylight harvesting are highly relevant for energy-efficient buildings. Despite recent progress demonstrated with passively cooling polymer coatings, however, it remains challenging to combine also a passive heat gain mechanism into a single substrate for all-round thermal management. Herein, we developed an optical wood (OW) with switcha…
▽ More
Technologies enabling passive daytime radiative cooling and daylight harvesting are highly relevant for energy-efficient buildings. Despite recent progress demonstrated with passively cooling polymer coatings, however, it remains challenging to combine also a passive heat gain mechanism into a single substrate for all-round thermal management. Herein, we developed an optical wood (OW) with switchable transmittance of solar irradiation enabled by the hierarchically porous structure, ultralow absorption in solar spectrum and high infrared absorption of cellulose nanofibers. After delignification, the OW shows a high solar reflectance (94.9%) in the visible and high broadband emissivity (0.93) in the infrared region (2.5-25 $μ$m). Owing to the exceptional mass transport of its aligned cellulose nanofibers, OW can quickly switch to a new highly transparent state following phenylethanol impregnation. The solar transmittance of optical wood (OW-II state) can reach 68.4% from 250 to 2500 nm. The switchable OW exhibits efficient radiative cooling to 4.5 °C below ambient temperature in summer (81.4 W m$^{-2}$ cooling power), and daylight heating to 5.6 °C above the temperature of natural wood in winter (heating power 229.5 W m$^{-2}$), suggesting its promising role as a low-cost and sustainable solution to all-season thermal management applications.
△ Less
Submitted 11 March, 2024; v1 submitted 22 December, 2023;
originally announced December 2023.
-
In-phase schooling hinders linear acceleration in wavy hydrofoils paired in parallel across various wavelengths
Authors:
Zhonglu Lin,
Dongfang Liang,
Yu Zhang
Abstract:
This study examines the impact of in-phase schooling on the hydrodynamic efficiency during linear acceleration in a simplified model using two undulating NACA0012 hydrofoils arranged in phalanx formation as a minimal representation of a fish school. The research focuses on key parameters, namely Strouhal (0.2-0.7) and Reynolds (1000-2000) numbers, and explores the effect of varying fish-body wavel…
▽ More
This study examines the impact of in-phase schooling on the hydrodynamic efficiency during linear acceleration in a simplified model using two undulating NACA0012 hydrofoils arranged in phalanx formation as a minimal representation of a fish school. The research focuses on key parameters, namely Strouhal (0.2-0.7) and Reynolds (1000-2000) numbers, and explores the effect of varying fish-body wavelengths (0.5-2), reflecting natural changes during actual fish linear acceleration. Contrary to expectations, in-phase schooling did not enhance acceleration performance. Both propulsive efficiency and net thrust were found to be lower compared to solitary swimming and anti-phase schooling conditions. The study also identifies and categorizes five distinct flow structure patterns within the parameters investigated, providing insight into the fluid dynamics of schooling fish during acceleration.
△ Less
Submitted 12 December, 2023;
originally announced December 2023.
-
Universal Murray's law for optimised fluid transport in synthetic structures
Authors:
Binghan Zhou,
Qian Cheng,
Zhuo Chen,
Zesheng Chen,
Dongfang Liang,
Eric Anthony Munro,
Guolin Yun,
Yoshiki Kawai,
Jinrui Chen,
Tynee Bhowmick,
Padmanathan Karthick Kannan,
Luigi G. Occhipinti,
Hidetoshi Matsumoto,
Julian Gardner,
Bao-Lian Su,
Tawfique Hasan
Abstract:
Materials following Murray's law are of significant interest due to their unique porous structure and optimal mass transfer ability. However, it is challenging to construct such biomimetic hierarchical channels with perfectly cylindrical pores in synthetic systems following the existing theory. Achieving superior mass transport capacity revealed by Murray's law in nanostructured materials has thus…
▽ More
Materials following Murray's law are of significant interest due to their unique porous structure and optimal mass transfer ability. However, it is challenging to construct such biomimetic hierarchical channels with perfectly cylindrical pores in synthetic systems following the existing theory. Achieving superior mass transport capacity revealed by Murray's law in nanostructured materials has thus far remained out of reach. We propose a Universal Murray's law applicable to a wide range of hierarchical structures, shapes and generalised transfer processes. We experimentally demonstrate optimal flow of various fluids in hierarchically planar and tubular graphene aerogel structures to validate the proposed law. By adjusting the macroscopic pores in such aerogel-based gas sensors, we also show a significantly improved sensor response dynamic. Our work provides a solid framework for designing synthetic Murray materials with arbitrarily shaped channels for superior mass transfer capabilities, with future implications in catalysis, sensing and energy applications.
△ Less
Submitted 14 April, 2024; v1 submitted 28 September, 2023;
originally announced September 2023.
-
Nanoscale Cathodoluminescence Spectroscopy Probing the Nitride Quantum Wells in an Electron Microcope
Authors:
Zhetong Liu,
Bingyao Liu,
Dongdong Liang,
Xiaomei Li,
Xiaomin Li,
Li Chen,
Rui Zhu,
Jun Xu,
Tongbo Wei,
Xuedong Bai,
Peng Gao
Abstract:
To gain a deeper understanding of the luminescence of multiquantum wells and the factors affecting it on a microscopic level, cathodoluminescence combined with scanning transmission electron microscopy and spectroscopy was used to reveal the luminescence of In0.15Ga0.85N five-period multiquantum wells. The composition-wave-energy relationship was established in combination with energy-dispersive X…
▽ More
To gain a deeper understanding of the luminescence of multiquantum wells and the factors affecting it on a microscopic level, cathodoluminescence combined with scanning transmission electron microscopy and spectroscopy was used to reveal the luminescence of In0.15Ga0.85N five-period multiquantum wells. The composition-wave-energy relationship was established in combination with energy-dispersive X-ray spectroscopy , and the bandgaps of In0.15Ga0.85N and GaN in multiple quantum wells were extracted by electron energy loss spectroscopy to understand the features of cathodoluminescence luminescence spectra. The luminescence differences between different periods of multiquantum wells and the effects on the luminescence of multiple quantum wells owing to defects such as composition fluctuation and dislocations were revealed. Our study establishing the direct correspondence between the atomic structure of InxGa1-xN multiquantum wells and photoelectric properties, provides useful information for nitride applications.
△ Less
Submitted 14 September, 2023;
originally announced September 2023.
-
Energy-Efficient Photonic Memory Based on Electrically Programmable Embedded III-V/Si Memristors: Switches and Filters
Authors:
Stanley Cheung,
Bassem Tossoun,
Yuan Yuan,
Yiwei Peng,
Yingtao Hu,
Geza Kurczveil,
Di Liang,
Raymond G. Beausoleil
Abstract:
We demonstrate non-volatile optical functionality by embedding multi-layer $HfO_2/Al_2O_3$ memristors with III-V/Si photonics. The wafer-bonded III-V/Si memristor facilitates non-volatile optical functionality for a variety of devices such as Mach-Zehnder Interferometers (MZIs), and (de-)interleaver filters. The MZI optical memristor exhibits non-volatile optical phase shifts…
▽ More
We demonstrate non-volatile optical functionality by embedding multi-layer $HfO_2/Al_2O_3$ memristors with III-V/Si photonics. The wafer-bonded III-V/Si memristor facilitates non-volatile optical functionality for a variety of devices such as Mach-Zehnder Interferometers (MZIs), and (de-)interleaver filters. The MZI optical memristor exhibits non-volatile optical phase shifts $> π(Δn_{g} > 2.70 \times 10^{-3}$) with ~ 30 dB extinction ratio while consuming 0 electrical power consumption in a true "set-and-forget" operation. We demonstrate 6 non-volatile states with each state capable of 4 Gbps modulation. III-V/Si (de-)interleavers were also demonstrated to exhibit memristive non-volatile passband transformation with full set/reset states. Time duration tests were performed on all devices and indicated non-volatility up to 24 hours and most likely beyond. To the best of our knowledge, we have demonstrated for the first time, non-volatile III-V/Si optical memristors with the largest electric-field driven phase shifts and reconfigurable filters with the lowest power consumption.
△ Less
Submitted 1 July, 2023;
originally announced July 2023.
-
Super resolution dual-layer CBCT imaging with model-guided deep learning
Authors:
Jiongtao Zhu,
Ting Su,
Xin Zhang,
Han Cui,
Yuhang Tan,
Hairong Zheng,
Dong Liang,
Jinchuan Guo,
Yongshuai Ge
Abstract:
Objective: This study aims at investigating a novel super resolution CBCT imaging technique with the dual-layer flat panel detector (DL-FPD). Approach: In DL-FPD based CBCT imaging, the low-energy and high-energy projections acquired from the top and bottom detector layers contain intrinsically mismatched spatial information, from which super resolution CBCT images can be generated. To explain, a…
▽ More
Objective: This study aims at investigating a novel super resolution CBCT imaging technique with the dual-layer flat panel detector (DL-FPD). Approach: In DL-FPD based CBCT imaging, the low-energy and high-energy projections acquired from the top and bottom detector layers contain intrinsically mismatched spatial information, from which super resolution CBCT images can be generated. To explain, a simple mathematical model is established according to the signal formation procedure in DL-FPD. Next, a dedicated recurrent neural network (RNN), named as suRi-Net, is designed by referring to the above imaging model to retrieve the high resolution dual-energy information. Different phantom experiments are conducted to validate the performance of this newly developed super resolution CBCT imaging method. Main Results: Results show that the proposed suRi-Net can retrieve high spatial resolution information accurately from the low-energy and high-energy projections having lower spatial resolution. Quantitatively, the spatial resolution of the reconstructed CBCT images of the top and bottom detector layers is increased by about 45% and 54%, respectively. Significance: In future, suRi-Net provides a new approach to achieve high spatial resolution dual-energy imaging in DL-FPD based CBCT systems.
△ Less
Submitted 28 June, 2023;
originally announced June 2023.
-
Non-volatile heterogeneous III-V/Si photonics via optical charge-trap memory
Authors:
Stanley Cheung,
Di Liang,
Yuan Yuan,
Yiwei Peng,
Yingtao Hu,
Geza Kurczveil,
Raymond G. Beausoleil
Abstract:
We demonstrate, for the first time, non-volatile charge-trap flash memory (CTM) co-located with heterogeneous III-V/Si photonics. The wafer-bonded III-V/Si CTM cell facilitates non-volatile optical functionality for a variety of devices such as Mach-Zehnder Interferometers (MZIs), asymmetric MZI lattice filters, and ring resonator filters. The MZI CTM exhibits full write/erase operation (100 cycle…
▽ More
We demonstrate, for the first time, non-volatile charge-trap flash memory (CTM) co-located with heterogeneous III-V/Si photonics. The wafer-bonded III-V/Si CTM cell facilitates non-volatile optical functionality for a variety of devices such as Mach-Zehnder Interferometers (MZIs), asymmetric MZI lattice filters, and ring resonator filters. The MZI CTM exhibits full write/erase operation (100 cycles with 500 states) with wavelength shifts of $Δλ_{non-volatile} = 1.16 nm$ ($Δn_{eff,non-volatile} ~ 2.5 \times 10^{-4}$) and a dynamic power consumption $<$ 20 pW (limited by measurement). Multi-bit write operation (2 bits) is also demonstrated and verified over a time duration of 24 hours and most likely beyond. The cascaded 2nd order ring resonator CTM filter exhibited an improved ER of ~ 7.11 dB compared to the MZI and wavelength shifts of $Δλ_{non-volatile} = 0.041 nm$ ($Δn_{eff, non-volatile} = 1.5 \times 10^{-4}$) with similar pW-level dynamic power consumption as the MZI CTM. The ability to co-locate photonic computing elements and non-volatile memory provides an attractive path towards eliminating the von-Neumann bottleneck.
△ Less
Submitted 27 May, 2023;
originally announced May 2023.
-
Fast and energy-efficient non-volatile III-V-on-silicon photonic phase shifter based on memristors
Authors:
Zhuoran Fang,
Bassem Tossoun,
Antoine Descos,
Di Liang,
Xue Huang,
Geza Kurczveil,
Arka Majumdar,
Raymond G. Beausoleil
Abstract:
Silicon photonics has evolved from lab research to commercial products in the past decade as it plays an increasingly crucial role in data communication for next-generation data centers and high performance computing1. Recently, programmable silicon photonics has also found new applications in quantum2 and classical 3 information processing. A key component of programmable silicon photonic integra…
▽ More
Silicon photonics has evolved from lab research to commercial products in the past decade as it plays an increasingly crucial role in data communication for next-generation data centers and high performance computing1. Recently, programmable silicon photonics has also found new applications in quantum2 and classical 3 information processing. A key component of programmable silicon photonic integrated circuits (PICs) is the phase shifter, traditionally realized via the thermo-optic or plasma dispersion effect which are weak, volatile, and power hungry. A non-volatile phase shifter can circumvent these limitations by requiring zero power to maintain the switched phases. Previously non-volatile phase modulation was achieved via phase-change4 or ferroelectric materials5, but the switching energy remains high (pico to nano joules) and the speed is slow (micro to milli seconds). Here, we report a non-volatile III-V-on-silicon photonic phase shifter based on HfO2 memristor with sub-pJ switching energy (~400fJ), representing over an order of magnitude improvement in energy efficiency compared to the state of the art. The non-volatile phase shifter can be switched reversibly using a single 100ns pulse and exhibits an excellent endurance over 800 cycles. This technology can enable future energy-efficient programmable PICs for data centers, optical neural networks, and quantum information processing.
△ Less
Submitted 23 May, 2023;
originally announced May 2023.
-
Model-driven CT reconstruction algorithm for nano-resolution X-ray phase contrast imaging
Authors:
Xuebao Cai,
Yuhang Tan,
Ting Su,
Dong Liang,
Hairong Zheng,
Jinyou Xu,
Peiping Zhu,
Yongshuai Ge
Abstract:
The low-density imaging performance of a zone plate based nano-resolution hard X-ray computed tomography (CT) system can be significantly improved by incorporating a grating-based Lau interferometer. Due to the diffraction, however, the acquired nano-resolution phase signal may suffer splitting problem, which impedes the direct reconstruction of phase contrast CT (nPCT) images. To overcome, a new…
▽ More
The low-density imaging performance of a zone plate based nano-resolution hard X-ray computed tomography (CT) system can be significantly improved by incorporating a grating-based Lau interferometer. Due to the diffraction, however, the acquired nano-resolution phase signal may suffer splitting problem, which impedes the direct reconstruction of phase contrast CT (nPCT) images. To overcome, a new model-driven nPCT image reconstruction algorithm is developed in this study. In it, the diffraction procedure is mathematically modeled into a matrix B, from which the projections without signal splitting can be generated invertedly. Furthermore, a penalized weighed least-square model with total variation (PWLS-TV) is employed to denoise these projections, from which nPCT images with high accuracy are directly reconstructed. Numerical and physical experiments demonstrate that this new algorithm is able to work with phase projections having any splitting distances. Results also reveal that nPCT images with higher signal-to-noise-ratio (SNR) would be reconstructed from projections with larger signal splittings. In conclusion, a novel model-driven nPCT image reconstruction algorithm with high accuracy and robustness is verified for the Lau interferometer based hard X-ray nano-resolution phase contrast imaging.
△ Less
Submitted 13 October, 2023; v1 submitted 14 May, 2023;
originally announced May 2023.
-
High-Speed and Energy-Efficient Non-Volatile Silicon Photonic Memory Based on Heterogeneously Integrated Memresonator
Authors:
Bassem Tossoun,
Di Liang,
Stanley Cheung,
Zhuoran Fang,
Xia Sheng,
John Paul Strachan,
Raymond G. Beausoleil
Abstract:
Recently, interest in programmable photonics integrated circuits has grown as a potential hardware framework for deep neural networks, quantum computing, and field programmable arrays (FPGAs). However, these circuits are constrained by the limited tuning speed and large power consumption of the phase shifters used. In this paper, introduced for the first time are memresonators, or memristors heter…
▽ More
Recently, interest in programmable photonics integrated circuits has grown as a potential hardware framework for deep neural networks, quantum computing, and field programmable arrays (FPGAs). However, these circuits are constrained by the limited tuning speed and large power consumption of the phase shifters used. In this paper, introduced for the first time are memresonators, or memristors heterogeneously integrated with silicon photonic microring resonators, as phase shifters with non-volatile memory. These devices are capable of retention times of 12 hours, switching voltages lower than 5 V, an endurance of 1,000 switching cycles. Also, these memresonators have been switched using voltage pulses as short as 300 ps with a record low switching energy of 0.15 pJ. Furthermore, these memresonators are fabricated on a heterogeneous III-V/Si platform capable of integrating a rich family of active, passive, and non-linear optoelectronic devices, such as lasers and detectors, directly on-chip to enable in-memory photonic computing and further advance the scalability of integrated photonic processor circuits.
△ Less
Submitted 25 May, 2023; v1 submitted 9 March, 2023;
originally announced March 2023.
-
How wavelength affects the hydrodynamic performance of two accelerating mirror-symmetric slender swimmers
Authors:
Zhonglu Lin,
Dongfang Liang,
Amneet Pal Singh Bhalla,
Ahmed A. Sheikh Al-Shabab,
Martin Skote,
Wei Zheng,
Yu Zhang
Abstract:
Fish schools are capable of simultaneous linear acceleration. To reveal the underlying hydrodynamic mechanism, we numerically investigate how Reynolds number $ Re = 1000 - 2000 $, Strouhal number $ St = 0.2 - 0.7 $ and wavelength $ λ= 0.5 - 2 $ affect the mean net thrust and net propulsive efficiency of two side-by-side hydrofoils undulating in anti-phase. In total, $ 550 $ cases are simulated usi…
▽ More
Fish schools are capable of simultaneous linear acceleration. To reveal the underlying hydrodynamic mechanism, we numerically investigate how Reynolds number $ Re = 1000 - 2000 $, Strouhal number $ St = 0.2 - 0.7 $ and wavelength $ λ= 0.5 - 2 $ affect the mean net thrust and net propulsive efficiency of two side-by-side hydrofoils undulating in anti-phase. In total, $ 550 $ cases are simulated using immersed boundary method. The thrust increases significantly with wavelength and Strouhal number, yet only slightly with the Reynolds number. We apply a symbolic regression algorithm to formulate this relationship. Furthermore, we find that mirror-symmetric schooling can achieve a \textit{net} thrust more than ten times that of a single swimmer, especially at low Reynolds numbers. The highest efficiency is obtained at $ St = 0.5 $ and $ λ= 1.2 $, where $ St $ is consistent with that observed in the linear-accelerating natural swimmers, \eg Crevalle jack. Six distinct flow structures are identified. The highest thrust corresponds to an asymmetric flow pattern, whereas the highest efficiency occurs when the flow is symmetric with converging vortex streets.
△ Less
Submitted 22 July, 2023; v1 submitted 21 December, 2022;
originally announced December 2022.
-
Optical Two-dimensional Coherent Spectroscopy of Cold Atoms
Authors:
Danfu Liang,
Lexter Savio Rodriguez,
Haitao Zhou,
Yifu Zhu,
Hebin Li
Abstract:
We report an experimental demonstration of optical 2DCS in cold atoms. The experiment integrates a collinear 2DCS setup with a magneto-optical trap (MOT), in which cold rubidium (Rb) atoms are prepared at a temperature of about 200 $μ$K and a number density of $10^{10}$ cm$^{-3}$. With a sequence of femtosecond laser pulses, we first obtained one-dimensional second- and fourth-order nonlinear sign…
▽ More
We report an experimental demonstration of optical 2DCS in cold atoms. The experiment integrates a collinear 2DCS setup with a magneto-optical trap (MOT), in which cold rubidium (Rb) atoms are prepared at a temperature of about 200 $μ$K and a number density of $10^{10}$ cm$^{-3}$. With a sequence of femtosecond laser pulses, we first obtained one-dimensional second- and fourth-order nonlinear signals and then acquired both one-quantum and zero-quantum 2D spectra of cold Rb atoms. The capability of performing optical 2DCS in cold atoms is an important step toward optical 2DCS study of many-body physics in cold atoms and ultimately in atom arrays and trapped ions. Optical 2DCS in cold atoms/molecules can also be a new avenue to probe chemical reaction dynamics in cold molecules.
△ Less
Submitted 18 October, 2022;
originally announced October 2022.
-
Super resolution dual-energy cone-beam CT imaging with dual-layer flat-panel detector
Authors:
Ting Su,
Jiongtao Zhu,
Xin Zhang,
Dong Zeng,
Yuhang Tan,
Han Cui,
Hairong Zheng,
Jianhua Ma,
Dong Liang,
Yongshuai Ge
Abstract:
For medical cone-beam computed tomography (CBCT) imaging, the native receptor array of the flat-panel detector (FPD) is usually binned into a reduced matrix size. By doing so, the signal readout speed can be increased by over 4-9 times at the expense of sacrificing the spatial resolution by at least 50%-67%. Clearly, such tradition poses a main bottleneck in generating high spatial resolution and…
▽ More
For medical cone-beam computed tomography (CBCT) imaging, the native receptor array of the flat-panel detector (FPD) is usually binned into a reduced matrix size. By doing so, the signal readout speed can be increased by over 4-9 times at the expense of sacrificing the spatial resolution by at least 50%-67%. Clearly, such tradition poses a main bottleneck in generating high spatial resolution and high temporal resolution CBCT images at the same time. In addition, the conventional FPD is also difficult in generating dual-energy CBCT images. In this paper, we propose an innovative super resolution dual-energy CBCT imaging method, named as suRi, based on dual-layer FPD (DL-FPD) to overcome these aforementioned difficulties at once. With suRi, specifically, an 1D or 2D sub-pixel (half pixel in this study) shifted binning is applied to replace the conventionally aligned binning to double the spatial sampling rate during the dual-energy data acquisition. As a result, the suRi approach provides a new strategy to enable high signal readout speed and high spatial resolution CBCT imaging with FPD. Moreover, a penalized likelihood material decomposition algorithm is developed to directly reconstruct the high resolution bases from the dual-energy CBCT projections containing spatial sub-pixel shifts. Experiments based on the single-layer FPD and DL-FPD are performed with physical phantoms and biological specimen to validate this newly developed suRi method. The synthesized monochromatic CT imaging results demonstrate that suRi can significantly improve the spatial image resolution by 46.15%. We believe the developed suRi method would be capable to greatly enhance the imaging performance of the DL-FPD based dual-energy CBCT systems in future.
△ Less
Submitted 17 October, 2022; v1 submitted 11 October, 2022;
originally announced October 2022.
-
CMOS based high-resolution dynamic X-ray imaging with inorganic perovskite
Authors:
Yanliang Liu,
Chaosong Gao,
Jiongtao Zhu,
Xin Zhang,
Meng Wu,
Ting Su,
Jiahong Wang,
Zonghai Sheng,
Wenjun Liu,
Tongyu Shi,
Xingchen He,
Dong Liang,
Hairong Zheng,
Xue-Feng Yu,
Xiangming Sun,
Yongshuai Ge
Abstract:
High-resolution dynamic X-ray detector is crucial for time-resolved digital radiography (DR) imaging and fast 3D medical computed tomography (CT) imaging. Recently, perovskites have become promising alternatives to conventional semi-conductor materials, e.g., Si, a-Se and CdTe, for direct X-ray detection. However, the feasibility of their combination with high-speed pixelated complementary metal-o…
▽ More
High-resolution dynamic X-ray detector is crucial for time-resolved digital radiography (DR) imaging and fast 3D medical computed tomography (CT) imaging. Recently, perovskites have become promising alternatives to conventional semi-conductor materials, e.g., Si, a-Se and CdTe, for direct X-ray detection. However, the feasibility of their combination with high-speed pixelated complementary metal-oxide-semiconductor (CMOS) arrays remains unknown. This work originally reports an innovative direct-conversion X-ray detector fabricated with 300 micrometer thick inorganic perovskite film printed on a tailored CMOS array. In-house measurements demonstrate that the CsPbBr3 film has excellent optoelectric properties of an electron mobility-lifetime product of 3.40x10$^{-5}$ cm$^2$ V$^{-1}$, and the X-ray detector exhibits high sensitivity of 9341uC Gy$_{\rm air}^{-1}$ cm$^{-2}$, and low detection limit of 588 nGy$_{\rm air}^{-1}$. This CMOS X-ray imaging detector achieves a high spatial resolution up to 5.5 lp/mm (close to the resolution limit of 6.0 lp/mm), and >300 frame per second (fps) readout speed. DR image of a resolution pattern phantom and a anesthesia mice, CT images of a biological specimen are acquired for the first time.
△ Less
Submitted 5 October, 2022;
originally announced October 2022.
-
Static spherical vacuum solutions in the bumblebee gravity model
Authors:
Rui Xu,
Dicong Liang,
Lijing Shao
Abstract:
The bumblebee gravity model is a vector-tensor theory of gravitation where the vector field nonminimally couples to the Ricci tensor. By investigating the vacuum field equations with spherical symmetry, we find two families of black-hole (BH) solutions in this model: one has a vanishing radial component of the vector field and the other has a vanishing radial component of the Ricci tensor. When th…
▽ More
The bumblebee gravity model is a vector-tensor theory of gravitation where the vector field nonminimally couples to the Ricci tensor. By investigating the vacuum field equations with spherical symmetry, we find two families of black-hole (BH) solutions in this model: one has a vanishing radial component of the vector field and the other has a vanishing radial component of the Ricci tensor. When the coupling between the vector field and the Ricci tensor is set to zero, the first family becomes the Reissner-Nordström solution while the second family degenerates to the Schwarzschild solution with the vector field being zero. General numerical solutions in both families are obtained for nonzero coupling between the vector field and the Ricci tensor. Besides BH solutions, we also reveal the existence of solutions that have a nonvanishing $tt$-component of the metric on the supposed event horizon where the $rr$-component of the metric diverges while the curvature scalars are finite. These solutions are not supported by existing observations but present certain properties that are of academic interests. We conclude the study by putting the BH solutions into tests against the Solar-system observations and the images of supermassive BHs.
△ Less
Submitted 24 December, 2022; v1 submitted 6 September, 2022;
originally announced September 2022.
-
How swimming style affects schooling of two fish-like wavy hydrofoils
Authors:
Zhonglu Lin,
Amneet Pal Singh Bhalla,
Boyce E. Griffith,
Zi Sheng,
Hongquan Li,
Dongfang Liang,
Yu Zhang
Abstract:
Fish swimming style and schooling behaviour are two important aspects of underwater locomotion. How swimming style affects fish schooling is investigated by a representative problem setup consisting of two tethered NACA0012 hydrofoils undulating in a free stream flow at various wavelengths $ λ^* = 0.8 - 8 $, front-back distance $ D = 0,\ 0.25,\ 0.5,\ 0.75 $, phase difference…
▽ More
Fish swimming style and schooling behaviour are two important aspects of underwater locomotion. How swimming style affects fish schooling is investigated by a representative problem setup consisting of two tethered NACA0012 hydrofoils undulating in a free stream flow at various wavelengths $ λ^* = 0.8 - 8 $, front-back distance $ D = 0,\ 0.25,\ 0.5,\ 0.75 $, phase difference $ φ/π= 0,\ 0.5,\ 1,\ 1.5 $, and lateral gap distance $ G = 0.25,\ 0.3,\ 0.35 $ with fixed Reynolds number $ Re = 5000 $, Strouhal number $ St = 0.4 $, and maximum amplitude $ A_{max} = 0.1 $. In total, 336 cases were simulated by open-source software IBAMR based on immersed boundary method. The increase in wavelength generally leads to higher thrust and lateral force, consistent with a previous study regarding a single swimmer. The highest Froude efficiency is obtained at intermediate wavelength $ λ^* = 2 $ for either individual or two foils as a group. At side-by-side arrangement $ D = 0 $, the thrust force upon the two foils can be equivalent, indicating a stable formation. At staggered arrangement, $ D > 0 $, the follower can take significant advantage of the leader in locomotion performance by tuning phase difference. The follower's benefit decreases with relative distance. Various combinations of wavelength and relative distance can lead to distinct flow structures, indicating a tunable stealth capacity of the schooling swimmers.
△ Less
Submitted 21 December, 2022; v1 submitted 4 September, 2022;
originally announced September 2022.
-
Jellybean quantum dots in silicon for qubit coupling and on-chip quantum chemistry
Authors:
Zeheng Wang,
MengKe Feng,
Santiago Serrano,
William Gilbert,
Ross C. C. Leon,
Tuomo Tanttu,
Philip Mai,
Dylan Liang,
Jonathan Y. Huang,
Yue Su,
Wee Han Lim,
Fay E. Hudson,
Christopher C. Escott,
Andrea Morello,
Chih Hwan Yang,
Andrew S. Dzurak,
Andre Saraiva,
Arne Laucht
Abstract:
The small size and excellent integrability of silicon metal-oxide-semiconductor (SiMOS) quantum dot spin qubits make them an attractive system for mass-manufacturable, scaled-up quantum processors. Furthermore, classical control electronics can be integrated on-chip, in-between the qubits, if an architecture with sparse arrays of qubits is chosen. In such an architecture qubits are either transpor…
▽ More
The small size and excellent integrability of silicon metal-oxide-semiconductor (SiMOS) quantum dot spin qubits make them an attractive system for mass-manufacturable, scaled-up quantum processors. Furthermore, classical control electronics can be integrated on-chip, in-between the qubits, if an architecture with sparse arrays of qubits is chosen. In such an architecture qubits are either transported across the chip via shuttling, or coupled via mediating quantum systems over short-to-intermediate distances. This paper investigates the charge and spin characteristics of an elongated quantum dot -- a so-called jellybean quantum dot -- for the prospects of acting as a qubit-qubit coupler. Charge transport, charge sensing and magneto-spectroscopy measurements are performed on a SiMOS quantum dot device at mK temperature, and compared to Hartree-Fock multi-electron simulations. At low electron occupancies where disorder effects and strong electron-electron interaction dominate over the electrostatic confinement potential, the data reveals the formation of three coupled dots, akin to a tunable, artificial molecule. One dot is formed centrally under the gate and two are formed at the edges. At high electron occupancies, these dots merge into one large dot with well-defined spin states, verifying that jellybean dots have the potential to be used as qubit couplers in future quantum computing architectures.
△ Less
Submitted 8 August, 2022;
originally announced August 2022.
-
Broadband Optical Two-Dimensional Coherent Spectroscopy of a Rubidium Atomic Vapor
Authors:
Jieli Yan,
Stephen Revesz,
Danfu Liang,
Hebin Li
Abstract:
Optical two-dimensional coherent spectroscopy (2DCS) has become a powerful tool for studying energy level structure, dynamics, and coupling in many systems including atomic ensembles. Various types of two-dimensional (2D) spectra, including the so-called single-quantum, zero-quantum, and double-quantum 2D spectra, of both D lines (D$_1$ and D$_2$ transitions) of potassium (K) atoms have been repor…
▽ More
Optical two-dimensional coherent spectroscopy (2DCS) has become a powerful tool for studying energy level structure, dynamics, and coupling in many systems including atomic ensembles. Various types of two-dimensional (2D) spectra, including the so-called single-quantum, zero-quantum, and double-quantum 2D spectra, of both D lines (D$_1$ and D$_2$ transitions) of potassium (K) atoms have been reported previously. For rubidium (Rb), a major difference is that the D-lines are about 15 nm apart as opposed to only about 3 nm for K. Simultaneously exciting both D-lines of Rb atoms requires a broader laser bandwidth for the experiment. Here, we report a broadband optical 2DCS experiment in an Rb atomic vapor. A complete set of single-quantum, zero-quantum, and double-quantum 2D spectra including both D-lines of Rb atoms were obtained. The experimental spectra were reproduced by simulated 2D spectra based on the perturbation solutions to the optical Bloch equations. This work in Rb atoms complements previous 2DCS studies of K and Rb with a narrower bandwidth that covers two D-lines of K or only a single D-line of Rb. The broadband excitation enables the capability to perform double-quantum and multi-quantum 2DCS of both D-lines of Rb to study many-body interactions and correlations in comparison with K atoms.
△ Less
Submitted 2 April, 2022;
originally announced April 2022.
-
Dual-domain Attention-based Deep Network for Sparse-view CT Artifact Reduction
Authors:
Xiang Gao,
Ting Su,
Jiongtao Zhu,
Jiecheng Yang,
Yunxin Zhang,
Donghua Mi,
Hairong Zheng,
Xiaojing Long,
Dong Liang,
Yongshuai Ge
Abstract:
Due to the wide applications of X-ray computed tomography (CT) in medical imaging activities, radiation exposure has become a major concern for public health. Sparse-view CT is a promising approach to reduce the radiation dose by down-sampling the total number of acquired projections. However, the CT images reconstructed by this sparse-view imaging approach suffer from severe streaking artifacts a…
▽ More
Due to the wide applications of X-ray computed tomography (CT) in medical imaging activities, radiation exposure has become a major concern for public health. Sparse-view CT is a promising approach to reduce the radiation dose by down-sampling the total number of acquired projections. However, the CT images reconstructed by this sparse-view imaging approach suffer from severe streaking artifacts and structural information loss. In this work, an end-to-end dual-domain attention-based deep network (DDANet) is proposed to solve such an ill-posed CT image reconstruction problem. The image-domain CT image and the projection-domain sinogram are put into the two parallel sub-networks of the DDANet to independently extract the distinct high-level feature maps. In addition, a specified attention module is introduced to fuse the aforementioned dual-domain feature maps to allow complementary optimizations of removing the streaking artifacts and mitigating the loss of structure. Numerical simulations, anthropomorphic thorax phantom and in vivo pre-clinical experiments are conducted to verify the sparse-view CT imaging performance of the DDANet. Results demonstrate that this newly developed approach is able to robustly remove the streaking artifacts while maintaining the fine structures. As a result, the DDANet provides a promising solution in achieving high quality sparse-view CT imaging.
△ Less
Submitted 17 March, 2022;
originally announced March 2022.
-
Variable Augmented Network for Invertible MR Coil Compression
Authors:
Xianghao Liao,
Shanshan Wang,
Lanlan Tu,
Yuhao Wang,
Dong Liang,
Qiegen Liu
Abstract:
A large number of coils are able to provide enhanced signal-to-noise ratio and improve imaging performance in parallel imaging. Nevertheless, the increasing growth of coil number simultaneously aggravates the drawbacks of data storage and reconstruction speed, especially in some iterative reconstructions. Coil compression addresses these issues by generating fewer virtual coils. In this work, a no…
▽ More
A large number of coils are able to provide enhanced signal-to-noise ratio and improve imaging performance in parallel imaging. Nevertheless, the increasing growth of coil number simultaneously aggravates the drawbacks of data storage and reconstruction speed, especially in some iterative reconstructions. Coil compression addresses these issues by generating fewer virtual coils. In this work, a novel variable augmentation network for invertible coil compression termed VAN-ICC is presented. It utilizes inherent reversibility of normalizing flow-based models for high-precision compression and invertible recovery. By employing the variable augmentation technology to image/k-space variables from multi-coils, VAN-ICC trains invertible networks by finding an invertible and bijective function, which can map the original data to the compressed counterpart and vice versa. Experiments conducted on both fully-sampled and under-sampled data verified the effectiveness and flexibility of VAN-ICC. Quantitative and qualitative comparisons with traditional non-deep learning-based approaches demonstrated that VAN-ICC can carry much higher compression effects. Additionally, its performance is not susceptible to different number of virtual coils.
△ Less
Submitted 19 March, 2022; v1 submitted 19 January, 2022;
originally announced January 2022.
-
Collective resonance of $D$ states in rubidium atoms probed by optical two-dimensional coherent spectroscopy
Authors:
Danfu Liang,
Yifu Zhu,
Hebin Li
Abstract:
Collective resonance of interacting particles has important implications in many-body quantum systems and their applications. Strong interactions can lead to a blockade that prohibits the excitation of a collective resonance of two or more nearby atoms. However, a collective resonance can be excited with the presence of weak interaction and has been observed for atoms in the first excited state (…
▽ More
Collective resonance of interacting particles has important implications in many-body quantum systems and their applications. Strong interactions can lead to a blockade that prohibits the excitation of a collective resonance of two or more nearby atoms. However, a collective resonance can be excited with the presence of weak interaction and has been observed for atoms in the first excited state ($P$ states). Here, we report the observation of collective resonance of rubidium atoms in a higher excited state ($D$ states) in addition to the first excited state. The collective resonance is excited by a double-quantum four-pulse excitation sequence. The resulting double-quantum two-dimensional (2D) spectrum displays well-isolated peaks that can be attributed to collective resonances of atoms in $P$ and $D$ states. The experimental one-quantum and double-quantum 2D spectra can be reproduced by a simulation based on the perturbative solutions to the optical Bloch equations, confirming collective resonances as the origin of the measured spectra. The experimental technique provides a new approach for preparing and probing collective resonances of atoms in highly excited states.
△ Less
Submitted 8 December, 2021;
originally announced December 2021.
-
Total-Body Low-Dose CT Image Denoising using Prior Knowledge Transfer Technique with Contrastive Regularization Mechanism
Authors:
Minghan Fu,
Yanhua Duan,
Zhaoping Cheng,
Wenjian Qin,
Ying Wang,
Dong Liang,
Zhanli Hu
Abstract:
Reducing the radiation exposure for patients in Total-body CT scans has attracted extensive attention in the medical imaging community. Given the fact that low radiation dose may result in increased noise and artifacts, which greatly affected the clinical diagnosis. To obtain high-quality Total-body Low-dose CT (LDCT) images, previous deep-learning-based research work has introduced various networ…
▽ More
Reducing the radiation exposure for patients in Total-body CT scans has attracted extensive attention in the medical imaging community. Given the fact that low radiation dose may result in increased noise and artifacts, which greatly affected the clinical diagnosis. To obtain high-quality Total-body Low-dose CT (LDCT) images, previous deep-learning-based research work has introduced various network architectures. However, most of these methods only adopt Normal-dose CT (NDCT) images as ground truths to guide the training of the denoising network. Such simple restriction leads the model to less effectiveness and makes the reconstructed images suffer from over-smoothing effects. In this paper, we propose a novel intra-task knowledge transfer method that leverages the distilled knowledge from NDCT images to assist the training process on LDCT images. The derived architecture is referred to as the Teacher-Student Consistency Network (TSC-Net), which consists of the teacher network and the student network with identical architecture. Through the supervision between intermediate features, the student network is encouraged to imitate the teacher network and gain abundant texture details. Moreover, to further exploit the information contained in CT scans, a contrastive regularization mechanism (CRM) built upon contrastive learning is introduced.CRM performs to pull the restored CT images closer to the NDCT samples and push far away from the LDCT samples in the latent space. In addition, based on the attention and deformable convolution mechanism, we design a Dynamic Enhancement Module (DEM) to improve the network transformation capability.
△ Less
Submitted 5 December, 2021; v1 submitted 1 December, 2021;
originally announced December 2021.
-
X-ray phase-sensitive microscope imaging with a grating interferometer: theory and simulation
Authors:
Jiecheng Yang,
Yongshuai Ge,
Dong Liang,
Hairong Zheng
Abstract:
In this work, a general theoretical framework is presented to explain the formation of the phase signal in an X-ray microscope integrated with a grating interferometer, which simultaneously enables the high spatial resolution imaging and the improved image contrast. Using this theory, several key parameters of phase contrast imaging can be predicted, for instance, the fringe visibility and period,…
▽ More
In this work, a general theoretical framework is presented to explain the formation of the phase signal in an X-ray microscope integrated with a grating interferometer, which simultaneously enables the high spatial resolution imaging and the improved image contrast. Using this theory, several key parameters of phase contrast imaging can be predicted, for instance, the fringe visibility and period, the conversion condition from the differential phase imaging (DPI) to the phase difference imaging (PDI). Additionally, numerical simulations are performed with certain X-ray optical components and imaging geometry. Results demonstrate the accuracy of this developed quantitative analysis method of X-ray phase-sensitive microscope imaging.
△ Less
Submitted 22 November, 2021;
originally announced November 2021.
-
Single-shot wide-field optical section imaging
Authors:
Yuyao Hu,
Dong Liang,
Jing Wang,
Yaping Xuan,
Fu Zhao,
Jun Liu,
Ruxin Li
Abstract:
Optical sectioning technology has been widely used in various fluorescence microscopes owing to its background removing capability. Here, a virtual HiLo based on edge detection (V-HiLo-ED) is proposed to achieve wide-field optical sectioning, which requires only single wide-field image. Compared with conventional optical sectioning technologies, its imaging speed can be increased by at least twice…
▽ More
Optical sectioning technology has been widely used in various fluorescence microscopes owing to its background removing capability. Here, a virtual HiLo based on edge detection (V-HiLo-ED) is proposed to achieve wide-field optical sectioning, which requires only single wide-field image. Compared with conventional optical sectioning technologies, its imaging speed can be increased by at least twice, meanwhile maintaining nice optical sectioning performance, low cost, and excellent artifact suppression capabilities. Furthermore, the new V-HiLo-ED can also be extended to other non-fluorescence imaging fields. This simple, cost-effective and easy-to-extend method will benefit many research and application fields that needs to remove out-of-focus blurred images.
△ Less
Submitted 5 November, 2021;
originally announced November 2021.
-
High temporal resolution total-body dynamic PET imaging based on pixel-level time-activity curve correction
Authors:
Zixiang Chen,
Yaping Wu,
Na Zhang,
Yu Shen,
Hairong Zheng,
Dong Liang,
Meiyun Wang,
Zhanli Hu
Abstract:
Dynamic positron emission tomography (dPET) is currently a widely used medical imaging technique for the clinical diagnosis, staging and therapy guidance of all kinds of human cancers. Higher temporal imaging resolution for the early stage of radiotracer metabolism is desired; however, in this case, the reconstructed images with short frame durations always suffer from a limited image signal-to-no…
▽ More
Dynamic positron emission tomography (dPET) is currently a widely used medical imaging technique for the clinical diagnosis, staging and therapy guidance of all kinds of human cancers. Higher temporal imaging resolution for the early stage of radiotracer metabolism is desired; however, in this case, the reconstructed images with short frame durations always suffer from a limited image signal-to-noise ratio (SNR) and unsatisfactory image spatial resolution. The appearance of uEXPLORER (United Imaging Healthcare, Inc.) with higher PET imaging sensitivity and resolution may help solving this problem. In this work, based on dynamic PET data acquired by uEXPLORER, we proposed a dPET processing method that denoises images with short frame durations via pixel-level time-activity curve (TAC) correction based on third-order Hermite interpolation (Pitch-In). The proposed method was validated and compared to several state-of-the-art methods to demonstrate its superior performance in terms of high temporal resolution dPET image noise reduction and imaging contrast. Higher stability and feasibility of the proposed Pitch-In method for future clinical application with high temporal resolution (HTR) dPET imaging can be expected.
△ Less
Submitted 5 December, 2021; v1 submitted 9 August, 2021;
originally announced August 2021.
-
Multi-functional microwave photonic radar system for simultaneous distance and velocity measurement and high-resolution microwave imaging
Authors:
Dingding Liang,
Lizhong Jiang,
Yang Chen
Abstract:
A photonic-assisted multi-functional radar system for simultaneous distance and velocity measurement and high-resolution microwave imaging is proposed and experimentally demonstrated by using a composite transmitted microwave signal of a single-chirped linearly frequency-modulated (LFM) signal and a single-tone microwave signal. In the system, the transmitted signal is generated via photonic frequ…
▽ More
A photonic-assisted multi-functional radar system for simultaneous distance and velocity measurement and high-resolution microwave imaging is proposed and experimentally demonstrated by using a composite transmitted microwave signal of a single-chirped linearly frequency-modulated (LFM) signal and a single-tone microwave signal. In the system, the transmitted signal is generated via photonic frequency up-conversion based on a single integrated dual-polarization dual-parallel Mach-Zehnder modulator (DPol-DPMZM), whereas the echo signals scattered from the target are de-chirped to two low-frequency signals using a microwave photonic frequency mixer. By using the two low-frequency de-chirped signals, the real-time distance and radial velocity of the moving target can be measured accurately according to the round-trip time of the echo signal and its Doppler frequency shift. Compared with the previous reported distance and velocity measurement methods, where two LFM signals with opposite chirps are used, these parameters can be obtained using only a single-chirped LFM signal and a single-tone microwave signal. Meanwhile, high-resolution inverse synthetic aperture radar (ISAR) imaging can also be realized using ISAR imaging algorithms. An experiment is performed to verify the proposed multi-functional microwave photonic radar system. An up-chirped LFM signal from 8.5 to 12.5 GHz and an 8.0 GHz single-tone microwave signal are used as the transmitted signal. The results show that the absolute measurement errors of distance and radial velocity are less than 5.9 cm and 2.8 cm/s, respectively. ISAR imaging results are also demonstrated, which proves the high-resolution and real-time ISAR imaging ability of the proposed system.
△ Less
Submitted 27 May, 2021;
originally announced June 2021.
-
Simultaneously improving multiple imaging parameters with scattering media
Authors:
Fu Zhao,
Shuman Du,
Dong Liang,
Jun Liu
Abstract:
Traditional optical imaging systems can provide high-quality imaging with complicated and expensive optical design by eliminating aberrations. With the help of optical memory effect (ME), not independently improving single imaging parameter, but simultaneously improving several imaging parameters by adding scattering media to the imaging systems was demonstrated firstly. As an example, in a simple…
▽ More
Traditional optical imaging systems can provide high-quality imaging with complicated and expensive optical design by eliminating aberrations. With the help of optical memory effect (ME), not independently improving single imaging parameter, but simultaneously improving several imaging parameters by adding scattering media to the imaging systems was demonstrated firstly. As an example, in a simple single-lens imaging system, except the depth-of-field (DOF) was improved greatly, spherical aberration, coma aberration and chromatic aberration were eliminated simultaneously by placing a scattering medium between the lens and the camera. The results indicate the potential applications of scattering media in many fields such as optical imaging, optical measurements and biomedical applications.
△ Less
Submitted 2 February, 2021;
originally announced February 2021.
-
DIRECT-Net: a unified mutual-domain material decomposition network for quantitative dual-energy CT imaging
Authors:
Ting Su,
Xindong Sun,
Yikun Zhang,
Haodi Wu,
Jianwei Chen,
Jiecheng Yang,
Yang Chen,
Hairong Zheng,
Dong Liang,
Yongshuai Ge
Abstract:
By acquiring two sets of tomographic measurements at distinct X-ray spectra, the dual-energy CT (DECT) enables quantitative material-specific imaging. However, the conventionally decomposed material basis images may encounter severe image noise amplification and artifacts, resulting in degraded image quality and decreased quantitative accuracy. Iterative DECT image reconstruction algorithms incorp…
▽ More
By acquiring two sets of tomographic measurements at distinct X-ray spectra, the dual-energy CT (DECT) enables quantitative material-specific imaging. However, the conventionally decomposed material basis images may encounter severe image noise amplification and artifacts, resulting in degraded image quality and decreased quantitative accuracy. Iterative DECT image reconstruction algorithms incorporating either the sinogram or the CT image prior information have shown potential advantages in noise and artifact suppression, but with the expense of large computational resource, prolonged reconstruction time, and tedious manual selections of algorithm parameters. To partially overcome these limitations, we develop a domain-transformation enabled end-to-end deep convolutional neural network (DIRECT-Net) to perform high quality DECT material decomposition. Specifically, the proposed DIRECT-Net has immediate accesses to mutual-domain data, and utilizes stacked convolution neural network (CNN) layers for noise reduction and material decomposition. The training data are numerically simulated based on the underlying physics of DECT imaging.The XCAT digital phantom, iodine solutions phantom, and biological specimen are used to validate the performance of DIRECT-Net. The qualitative and quantitative results demonstrate that this newly developed DIRECT-Net is promising in suppressing noise, improving image accuracy, and reducing computation time for future DECT imaging.
△ Less
Submitted 19 August, 2020;
originally announced August 2020.
-
DIR-DBTnet: Deep iterative reconstruction network for 3D digital breast tomosynthesis imaging
Authors:
Ting Su,
Xiaolei Deng,
Zhenwei Wang,
Jiecheng Yang,
Jianwei Chen,
Hairong Zheng,
Dong Liang,
Yongshuai Ge
Abstract:
Purpose: The goal of this study is to develop a novel deep learning (DL) based reconstruction framework to improve the digital breast tomosynthesis (DBT) imaging performance. Methods: In this work, the DIR-DBTnet is developed for DBT image reconstruction by unrolling the standard iterative reconstruction algorithm within the deep learning framework. In particular, such network learns the regulariz…
▽ More
Purpose: The goal of this study is to develop a novel deep learning (DL) based reconstruction framework to improve the digital breast tomosynthesis (DBT) imaging performance. Methods: In this work, the DIR-DBTnet is developed for DBT image reconstruction by unrolling the standard iterative reconstruction algorithm within the deep learning framework. In particular, such network learns the regularizer and the iteration parameters automatically through network training with a large amount of simulated DBT data. Afterwards, both numerical and experimental data are used to evaluate its performance. Quantitative metrics such as the artifact spread function (ASF), breast density, and the signal difference to noise ratio (SDNR) are used for image quality assessment. Results: For both numerical and experimental data, the proposed DIR-DBTnet generates reduced in-plane shadow artifacts and out-of-plane artifacts compared with the filtered back projection (FBP) and total variation (TV) methods. Quantitatively, the full width half maximum (FWHM) of the measured ASF curve from the numerical data is 33.4% and 19.7% smaller than those obtained with the FBP and TV methods, respectively; the breast density of the network reconstructed DBT images is more accurate and consistent with the ground truth. Conclusions: In conclusion, a deep iterative reconstruction network, DIR-DBTnet, has been proposed. Both qualitative and quantitative analyses of the numerical and experimental results show superior DBT imaging performance than the FBP and iterative algorithms.
△ Less
Submitted 19 August, 2020;
originally announced August 2020.
-
Estimation of angular sensitivity for X-ray interferometers with multiple phase gratings
Authors:
Jianwei Chen,
Jiecheng Yang,
Peiping Zhu,
Ting Su,
Huitao Zhang,
Hairong Zheng,
Dong Liang,
Yongshuai Ge
Abstract:
Recently, X-ray interferometers with more than one phase grating have been developed for differential phase contrast (DPC) imaging. In this study, a novel framework is developed to predict such interferometers' angular sensitivity responses (the minimum detectable refraction angle). Experiments are performed on the dual and triple phase grating interferometers, separately. Measurements show strong…
▽ More
Recently, X-ray interferometers with more than one phase grating have been developed for differential phase contrast (DPC) imaging. In this study, a novel framework is developed to predict such interferometers' angular sensitivity responses (the minimum detectable refraction angle). Experiments are performed on the dual and triple phase grating interferometers, separately. Measurements show strong consistency with the predicted sensitivity values. Using this new approach, the DPC imaging performance of X-ray interferometers with multiple phase gratings can be further optimized for future biomedical applications.
△ Less
Submitted 21 June, 2020;
originally announced June 2020.
-
Positive Contrast Susceptibility MR Imaging Using GPU-based Primal-Dual Algorithm
Authors:
Haifeng Wang,
Fang Cai,
Caiyun Shi,
Jing Cheng,
Shi Su,
Zhilang Qiu,
Guoxi Xie,
Hanwei Chen,
Xin Liu,
Dong Liang
Abstract:
The susceptibility-based positive contrast MR technique was applied to estimate arbitrary magnetic susceptibility distributions of the metallic devices using a kernel deconvolution algorithm with a regularized L-1 minimization.Previously, the first-order primal-dual (PD) algorithm could provide a faster reconstruction time to solve the L-1 minimization, compared with other methods. Here, we propos…
▽ More
The susceptibility-based positive contrast MR technique was applied to estimate arbitrary magnetic susceptibility distributions of the metallic devices using a kernel deconvolution algorithm with a regularized L-1 minimization.Previously, the first-order primal-dual (PD) algorithm could provide a faster reconstruction time to solve the L-1 minimization, compared with other methods. Here, we propose to accelerate the PD algorithm of the positive contrast image using the multi-core multi-thread feature of graphics processor units (GPUs). The some experimental results showed that the GPU-based PD algorithm could achieve comparable accuracy of the metallic interventional devices in positive contrast imaging with less computational time. And the GPU-based PD approach was 4~15 times faster than the previous CPU-based scheme.
△ Less
Submitted 17 June, 2020;
originally announced June 2020.
-
Electric field thermopower modulation analyses of the operation mechanism of transparent amorphous SnO$_2$ thin-film transistor
Authors:
Dou-dou Liang,
Yu-qiao Zhang,
Hai Jun Cho,
Hiromichi Ohta
Abstract:
Transparent amorphous oxide semiconductors (TAOSs) based transparent thin-film transistors (TTFTs) with high field effect mobility are essential for developing advanced flat panel displays. Among TAOSs, amorphous (a-) SnO$_2$ has several advantages against current a-InGaZnO4 such as higher field effect mobility and being indium free. Although a-SnO$_2$ TTFT has been demonstrated several times, the…
▽ More
Transparent amorphous oxide semiconductors (TAOSs) based transparent thin-film transistors (TTFTs) with high field effect mobility are essential for developing advanced flat panel displays. Among TAOSs, amorphous (a-) SnO$_2$ has several advantages against current a-InGaZnO4 such as higher field effect mobility and being indium free. Although a-SnO$_2$ TTFT has been demonstrated several times, the operation mechanism has not been clarified thus far due to the strong gas sensing characteristics of SnO$_2$. Here we clarify the operation mechanism of a-SnO$_2$ TTFT by electric field thermopower modulation analyses. We prepared a bottom-gate top-contact type TTFT using 4.2-nm-thick a-SnO$_2$ as the channel without any surface passivation. The effective thickness of the conducting channel was ~1.7 + - 0.4 nm in air and in vacuum, but a large threshold gate voltage shift occurred in different atmospheres; this is attributed to carrier depletion near at the top surface (~2.5 nm) of the a-SnO$_2$ due to its interaction with the gas molecules and the resulting shift in the Fermi energy. The present results would provide a fundamental design concept to develop a-SnO$_2$ TTFT.
△ Less
Submitted 23 March, 2020;
originally announced March 2020.
-
Visualization of fully connected layer weights in deep learning CT reconstruction
Authors:
Qiyang Zhang,
Dong Liang
Abstract:
Recently, the use of deep learning techniques to reconstruct computed tomography (CT) images has become a hot research topic, including sinogram domain methods, image domain methods and sinogram domain to image domain methods. All these methods have achieved favorable results. In this article, we have studied the important functions of fully connected layers used in the sinogram domain to image do…
▽ More
Recently, the use of deep learning techniques to reconstruct computed tomography (CT) images has become a hot research topic, including sinogram domain methods, image domain methods and sinogram domain to image domain methods. All these methods have achieved favorable results. In this article, we have studied the important functions of fully connected layers used in the sinogram domain to image domain approach. First, we present a simple domain mapping neural networks. Then, we analyze the role of the fully connected layers of these networks and visually analyze the weights of the fully connected layers. Finally, by visualizing the weights of the fully connected layer, we found that the main role of the fully connected layer is to implement the back projection function in CT reconstruction. This finding has important implications for the use of deep learning techniques to reconstruct computed tomography (CT) images. For example, since fully connected layer weights need to consume huge memory resources, the back-projection function can be implemented by using analytical algorithms to avoid resource occupation, which can be embedded in the entire network.
△ Less
Submitted 17 February, 2020;
originally announced February 2020.
-
SuperDTI: Ultrafast diffusion tensor imaging and fiber tractography with deep learning
Authors:
Hongyu Li,
Zifei Liang,
Chaoyi Zhang,
Ruiying Liu,
Jing Li,
Weihong Zhang,
Dong Liang,
Bowen Shen,
Xiaoliang Zhang,
Yulin Ge,
Jiangyang Zhang,
Leslie Ying
Abstract:
Purpose: To propose a deep learning-based reconstruction framework for ultrafast and robust diffusion tensor imaging and fiber tractography. Methods: We propose SuperDTI to learn the nonlinear relationship between diffusion-weighted images (DWIs) and the corresponding tensor-derived quantitative maps as well as the fiber tractography. Super DTI bypasses the tensor fitting procedure, which is well…
▽ More
Purpose: To propose a deep learning-based reconstruction framework for ultrafast and robust diffusion tensor imaging and fiber tractography. Methods: We propose SuperDTI to learn the nonlinear relationship between diffusion-weighted images (DWIs) and the corresponding tensor-derived quantitative maps as well as the fiber tractography. Super DTI bypasses the tensor fitting procedure, which is well known to be highly susceptible to noise and motion in DWIs. The network is trained and tested using datasets from Human Connectome Project and patients with ischemic stroke. SuperDTI is compared against the state-of-the-art methods for diffusion map reconstruction and fiber tracking. Results: Using training and testing data both from the same protocol and scanner, SuperDTI is shown to generate fractional anisotropy and mean diffusivity maps, as well as fiber tractography, from as few as six raw DWIs. The method achieves a quantification error of less than 5% in all regions of interest in white matter and gray matter structures. We also demonstrate that the trained neural network is robust to noise and motion in the testing data, and the network trained using healthy volunteer data can be directly applied to stroke patient data without compromising the lesion detectability. Conclusion: This paper demonstrates the feasibility of superfast diffusion tensor imaging and fiber tractography using deep learning with as few as six DWIs directly, bypassing tensor fitting. Such a significant reduction in scan time may allow the inclusion of DTI into the clinical routine for many potential applications.
△ Less
Submitted 24 March, 2021; v1 submitted 3 February, 2020;
originally announced February 2020.
-
Model Learning: Primal Dual Networks for Fast MR imaging
Authors:
Jing Cheng,
Haifeng Wang,
Leslie Ying,
Dong Liang
Abstract:
Magnetic resonance imaging (MRI) is known to be a slow imaging modality and undersampling in k-space has been used to increase the imaging speed. However, image reconstruction from undersampled k-space data is an ill-posed inverse problem. Iterative algorithms based on compressed sensing have been used to address the issue. In this work, we unroll the iterations of the primal-dual hybrid gradient…
▽ More
Magnetic resonance imaging (MRI) is known to be a slow imaging modality and undersampling in k-space has been used to increase the imaging speed. However, image reconstruction from undersampled k-space data is an ill-posed inverse problem. Iterative algorithms based on compressed sensing have been used to address the issue. In this work, we unroll the iterations of the primal-dual hybrid gradient algorithm to a learnable deep network architecture, and gradually relax the constraints to reconstruct MR images from highly undersampled k-space data. The proposed method combines the theoretical convergence guarantee of optimi-zation methods with the powerful learning capability of deep networks. As the constraints are gradually relaxed, the reconstruction model is finally learned from the training data by updating in k-space and image domain alternatively. Experi-ments on in vivo MR data demonstrate that the proposed method achieves supe-rior MR reconstructions from highly undersampled k-space data over other state-of-the-art image reconstruction methods.
△ Less
Submitted 6 August, 2019;
originally announced August 2019.