-
Operating a near-concentric cavity at the last stable resonance
Authors:
Chi Huan Nguyen,
Adrian Nugraha Utama,
Nick Lewty,
Christian Kurtsiefer
Abstract:
Near-concentric optical cavities of spherical mirrors can provide technical advantages over the conventional near-planar cavities in applications requiring strong atom-light interaction, as they concentrate light in a very small region of space. However, such cavities barely support stable optical modes, and thus impose practical challenges. Here, we present an experiment where we maintain a near-…
▽ More
Near-concentric optical cavities of spherical mirrors can provide technical advantages over the conventional near-planar cavities in applications requiring strong atom-light interaction, as they concentrate light in a very small region of space. However, such cavities barely support stable optical modes, and thus impose practical challenges. Here, we present an experiment where we maintain a near-concentric cavity at its last resonant length for laser light at 780 nm resonant with an atomic transition. At this point, the spacing of two spherical mirror surfaces is 207(13) nm shorter than the critical concentric point, corresponding to a stability parameter g=-0.999962(2) and a cavity beam waist of 2.4 $μ$m.
△ Less
Submitted 8 June, 2018;
originally announced June 2018.
-
Experimental determination of the nuclear magnetic octupole moment of $^{137}$Ba$^+$ ion
Authors:
Nicholas C. Lewty,
Boon Leng Chuah,
Radu Cazan,
B. K. Sahoo,
M. D. Barrett
Abstract:
We perform precision measurements on the 5D$_{5/2}$ manifold hyperfine intervals of a single trapped ion, $^{137}$Ba$^+$. RF spectroscopy is used to measure the hyperfine intervals to an accuracy of a few Hz. Our results provide a three orders of magnitude improvement in accuracy over previous work and also provide a 10-fold improvement in the value of $g_J$ for this level. These results complemen…
▽ More
We perform precision measurements on the 5D$_{5/2}$ manifold hyperfine intervals of a single trapped ion, $^{137}$Ba$^+$. RF spectroscopy is used to measure the hyperfine intervals to an accuracy of a few Hz. Our results provide a three orders of magnitude improvement in accuracy over previous work and also provide a 10-fold improvement in the value of $g_J$ for this level. These results complement our previous work on the 5D$_{3/2}$ manifold of $^{137}$Ba$^+$, providing an independent measurement of the nuclear octupole, and a consistency check on atomic structure calculations.
△ Less
Submitted 1 July, 2013; v1 submitted 20 May, 2013;
originally announced May 2013.
-
Sub-Doppler Cavity Cooling Beyond The Lamb-Dicke Limit
Authors:
Boon Leng Chuah,
Nicholas C. Lewty,
Radu Cazan,
Murray D. Barrett
Abstract:
We investigate the dynamics of cavity cooling of a single ion beyond the Lamb-Dicke regime and demonstrate a cooling limit of approximately 50% of the Doppler temperature using a high finesse cavity for the first time. We also study the statistical properties of the ion-cavity emission and present a model that maps the phonon states to the photon states. With this model, we explain the super-Poiss…
▽ More
We investigate the dynamics of cavity cooling of a single ion beyond the Lamb-Dicke regime and demonstrate a cooling limit of approximately 50% of the Doppler temperature using a high finesse cavity for the first time. We also study the statistical properties of the ion-cavity emission and present a model that maps the phonon states to the photon states. With this model, we explain the super-Poissonian photon distribution observed in our experiments and propose a method to estimate the ion temperature in a real-time manner based on the statistical behavior of the photon emission from the cavity.
△ Less
Submitted 19 April, 2013; v1 submitted 19 February, 2013;
originally announced February 2013.
-
Minimization of Ion Micromotion in a Linear Paul Trap with a High Finesse Cavity
Authors:
Boon Leng Chuah,
Nicholas C. Lewty,
Radu Cazan,
Murray D. Barrett
Abstract:
We demonstrate minimization of ion micromotion in a linear Paul trap with the use of a high finesse cavity. The excess ion micromotion projected along the optical cavity axis or along the laser propagation direction manifests itself as sideband peaks around the carrier in the ion-cavity emission spectrum. By minimizing the sideband height in the emission spectrum, we are able to reduce the micromo…
▽ More
We demonstrate minimization of ion micromotion in a linear Paul trap with the use of a high finesse cavity. The excess ion micromotion projected along the optical cavity axis or along the laser propagation direction manifests itself as sideband peaks around the carrier in the ion-cavity emission spectrum. By minimizing the sideband height in the emission spectrum, we are able to reduce the micromotion amplitude to approximately the spread of the ground state wave function. This method is useful for cavity QED experiments as it allows for efficient 3-D micromotion compensation despite optical access limitations imposed by the cavity mirrors. We also show that sub-nanometer micromotion compensation is possible with our current system.
△ Less
Submitted 1 November, 2012;
originally announced November 2012.
-
Spectroscopy on a single trapped 137Ba+ ion for nuclear magnetic octupole moment determination
Authors:
Nicholas C. Lewty,
Boon Leng Chuah,
Radu Cazan,
B. K. Sahoo,
M. D. Barrett
Abstract:
We present precision measurements of the hyperfine intervals in the 5D3/2 manifold of a single trapped Barium ion, 137 Ba+ . Measurements of the hyperfine intervals are made between mF = 0 sublevels over a range of magnetic fields allowing us to interpolate to the zero field values with an accuracy below a few Hz, an improvement on previous measurements by three orders of magnitude. Our results, i…
▽ More
We present precision measurements of the hyperfine intervals in the 5D3/2 manifold of a single trapped Barium ion, 137 Ba+ . Measurements of the hyperfine intervals are made between mF = 0 sublevels over a range of magnetic fields allowing us to interpolate to the zero field values with an accuracy below a few Hz, an improvement on previous measurements by three orders of magnitude. Our results, in conjunction with theoretical calculations, provide a 30-fold reduction in the uncertainty of the magnetic dipole (A) and electric quadrupole (B) hyperfine constants. In addition, we obtain the magnetic octupole constant (C) with an accuracy below 0.1 Hz. This gives a subsequent determination of the nuclear magnetic octupole moment, Ω, with an uncertainty of 1% limited almost completely by the accuracy of theoretical calculations. This constitutes the first observation of the octupole moment in 137 Ba+ and the most accurately determined octupole moment to date.
△ Less
Submitted 4 July, 2012; v1 submitted 31 May, 2012;
originally announced May 2012.