-
Proton irradiation effects on metal-YBCO interfaces
Authors:
C. Acha,
G. A. Sanca,
M. Barella,
M. Alurralde,
F. Gomez Marlasca,
H. Huhtinen,
P. Paturi,
F. Golmar,
P. Levy
Abstract:
10 MeV proton-irradiation effects on a YBCO-based test structure were analyzed by measuring its current-voltage (IV) characteristics for different cumulated fluences. For fluences of up to $\sim$80$\cdot$10$^9$~p/cm$^2$ no changes in the electrical behavior of the device were observed, while for a fluence of $\sim$~300$\cdot$10$^9~$ p/cm$^2$ it becomes less conducting. A detailed analysis of the r…
▽ More
10 MeV proton-irradiation effects on a YBCO-based test structure were analyzed by measuring its current-voltage (IV) characteristics for different cumulated fluences. For fluences of up to $\sim$80$\cdot$10$^9$~p/cm$^2$ no changes in the electrical behavior of the device were observed, while for a fluence of $\sim$~300$\cdot$10$^9~$ p/cm$^2$ it becomes less conducting. A detailed analysis of the room temperature IV characteristics based on the $γ$ power exponent parameter [$γ=dLn(I)/dLn(V)$] allowed us to reveal the main conduction mechanisms as well as to establish the equivalent circuit model of the device. The changes produced in the electrical behavior, in accordance with Monte Carlo TRIM simulations, suggest that the main effect induced by protons is the displacement of oxygen atoms within the YBCO lattice, particularly from oxygen-rich to oxygen-poor areas, where they become trapped.
△ Less
Submitted 27 February, 2021;
originally announced March 2021.
-
COTS MOS Dosimetry on the MeMOSat Board, Results After 2.5 Years in Orbit
Authors:
José Lipovetzky,
Mariano Garcia-Inza,
Macarena Rodríguez Cañete,
Gabriel Redin,
Sebastián Carbonetto,
Martín Echarri,
Federico Golmar,
Fernando Gomez Marlasca,
Mariano Barella,
Gabriel A. Sanca,
Pablo Levy,
Adrián Faigón
Abstract:
We present the results after 2.5 years in or-bit of Total Ionizing Dose (TID) measurements done using Metal Oxide Semiconductor (MOS) dosimeters on the MeMOSat board. The MeMOSat board was launched on July 19th 2014 at the BugSat-1 "Tita" microsatellite developed by Satellogic to stay at LEO. We used as dosimeters p-channel Commercial Off The Shelf (COTS) MOS transistors with gate oxides of 250~nm…
▽ More
We present the results after 2.5 years in or-bit of Total Ionizing Dose (TID) measurements done using Metal Oxide Semiconductor (MOS) dosimeters on the MeMOSat board. The MeMOSat board was launched on July 19th 2014 at the BugSat-1 "Tita" microsatellite developed by Satellogic to stay at LEO. We used as dosimeters p-channel Commercial Off The Shelf (COTS) MOS transistors with gate oxides of 250~nm. Before launch, a subset of transistors with similar drain current to voltage (I-V)curves where selected from a group of 100 devices. The temperature dependence of the (I-V) curves was studied to find the minimum temperature coefficient biasing point. Then, a calibration subgroup of sensors was irradiated using a $^{60}$Co gamma source to study their response to TID, showing responsivities of $\sim$75~mV/krad when the sensors are irradiated without gate bias. Also, the post irradiation response of the sensors was monitored, in order to include a correction for low dose rate irradiations, yielding 30~mV/krad. A biasing and reading circuit was developed in order to allow the reading of up to 4 sensors.The threshold voltage was monitored during different periods of the mission. After 2.5 years in orbit,the threshold voltage of the sensor mounted on the MeMOSat Board had a V$_\mathrm{T}$ shift of approximately 35~mV corresponds to a dose of 1.2~krads.
△ Less
Submitted 30 June, 2020;
originally announced July 2020.
-
LabOSat as a versatile payload for small satellites: first 100days in LEO orbit
Authors:
G. A. Sanca,
M. Barella,
F. Gomez Marlasca,
G. Rodríguez,
D. Martelliti,
L. Patrone,
P. Levy,
F. Golmar
Abstract:
In this work the first results obtained by LabOSat-01 platform are presented. This platform was designed for testing custom devices on board of small satellites. Two LabOSat-01 type boards were launched and placed into Low Earth Orbit (LEO) on May 30, 2016. We present here an analysis of data collected by one of these boards during the first days of mission. Total Ionization Dose results are compa…
▽ More
In this work the first results obtained by LabOSat-01 platform are presented. This platform was designed for testing custom devices on board of small satellites. Two LabOSat-01 type boards were launched and placed into Low Earth Orbit (LEO) on May 30, 2016. We present here an analysis of data collected by one of these boards during the first days of mission. Total Ionization Dose results are compared with data acquired by LabOSat-01`s predecessor board, MeMOSat-01, launched in 2014.
△ Less
Submitted 30 June, 2020;
originally announced July 2020.
-
YBCO-based non-volatile ReRAM tested in Low Earth Orbit
Authors:
C. Acha,
M. Barella,
G. A. Sanca,
F. Gomez Marlasca,
H. Huhtinen,
P. Paturi,
P. Levy,
F. Golmar
Abstract:
An YBCO-based test structure corresponding to the family of ReRAM devices associated with the valence change mechanism is presented. We have characterized its electrical response previous to its lift-off to a Low Earth Orbit (LEO) using standard electronics and also with the dedicated LabOSat-01 controller. Similar results were obtained in both cases. After about 200 days at LEO on board a small s…
▽ More
An YBCO-based test structure corresponding to the family of ReRAM devices associated with the valence change mechanism is presented. We have characterized its electrical response previous to its lift-off to a Low Earth Orbit (LEO) using standard electronics and also with the dedicated LabOSat-01 controller. Similar results were obtained in both cases. After about 200 days at LEO on board a small satellite, electrical tests started on the memory device using the LabOSat-01 controller. We discuss the results of the first 150 tests, performed along a 433-day time interval in space. The memory device remained operational despite the hostile conditions that involved launching, lift-off vibrations, permanent thermal cycling and exposure to ionizing radiation, with doses 3 orders of magnitude greater than the usual ones on Earth. The device showed resistive switching and IV characteristics similar to those measured on Earth, although with changes that follow a smooth drift in time. A detailed study of the electrical transport mechanisms, based on previous models that indicate the existence of various conducting mechanisms through the metal-YBCO interface showed that the observed drift can be associated with a local temperature drift at the LabOSat controller, with no clear evidence that allows determining changes in the underlying microscopic factors. These results show the reliability of complex-oxide non-volatile ReRAM-based devices in order to operate under all the hostile conditions encountered in space-borne applications.
△ Less
Submitted 26 June, 2020;
originally announced June 2020.
-
The dynamics of liquid 1-ethyl-3-methylimidazolium acetate measured with implanted-ion $^8$Li $β$-NMR
Authors:
Derek Fujimoto,
Ryan M. L. McFadden,
Martin H. Dehn,
Yael Petel,
Aris Chatzichristos,
Lars Hemmingsen,
Victoria L. Karner,
Robert F. Kiefl,
C. D. Philip Levy,
Iain McKenzie,
Carl A. Michal,
Gerald D. Morris,
Matthew R. Pearson,
Daniel Szunyogh,
John O. Ticknor,
Monika Stachura,
W. Andrew MacFarlane
Abstract:
We demonstrate the application of implanted-ion $β$-detected NMR as a probe of ionic liquid molecular dynamics through the measurement of $^8$Li spin-lattice relaxation (SLR) and resonance in 1-ethyl-3-methylimidazolium acetate. The motional narrowing of the resonance, and the local maxima in the SLR rate, $1/T_1$, imply a sensitivity to sub-nanosecond Li$^+$ solvation dynamics. From an analysis o…
▽ More
We demonstrate the application of implanted-ion $β$-detected NMR as a probe of ionic liquid molecular dynamics through the measurement of $^8$Li spin-lattice relaxation (SLR) and resonance in 1-ethyl-3-methylimidazolium acetate. The motional narrowing of the resonance, and the local maxima in the SLR rate, $1/T_1$, imply a sensitivity to sub-nanosecond Li$^+$ solvation dynamics. From an analysis of $1/T_1$, we extract an activation energy ${E_A = 74.8 \pm 1.5}$ meV and Vogel-Fulcher-Tammann constant ${T_{\mathrm{VFT}} = 165.8 \pm 0.9}$ K, in agreement with the dynamic viscosity of the bulk solvent. Near the melting point, the lineshape is broad and intense, and the form of the relaxation is non-exponential, reflective of our sensitivity to heterogeneous dynamics near the glass transition. The depth resolution of this technique may later provide a unique means of studying nanoscale phenomena in ionic liquids.
△ Less
Submitted 31 October, 2019; v1 submitted 8 July, 2019;
originally announced July 2019.
-
Isotope Shift Measurements of Stable and Short-Lived Lithium Isotopes for Nuclear Charge Radii Determination
Authors:
W. Nörtershäuser,
R. Sánchez,
G. Ewald,
A. Dax,
J. Behr,
P. Bricault,
B. A. Bushaw,
J. Dilling,
M. Dombsky,
G. W. F. Drake,
S. Götte,
H. -J. Kluge,
Th. Kühl,
J. Lassen,
C. D. P. Levy,
K. Pachucki,
M. Pearson,
M. Puchalski,
A. Wojtaszek,
Z. -C. Yan,
C. Zimmermann
Abstract:
Changes in the mean-square nuclear charge radii along the lithium isotopic chain were determined using a combination of precise isotope shift measurements and theoretical atomic structure calculations. Nuclear charge radii of light elements are of high interest due to the appearance of the nuclear halo phenomenon in this region of the nuclear chart. During the past years we have developed a new la…
▽ More
Changes in the mean-square nuclear charge radii along the lithium isotopic chain were determined using a combination of precise isotope shift measurements and theoretical atomic structure calculations. Nuclear charge radii of light elements are of high interest due to the appearance of the nuclear halo phenomenon in this region of the nuclear chart. During the past years we have developed a new laser spectroscopic approach to determine the charge radii of lithium isotopes which combines high sensitivity, speed, and accuracy to measure the extremely small field shift of an 8 ms lifetime isotope with production rates on the order of only 10,000 atoms/s. The method was applied to all bound isotopes of lithium including the two-neutron halo isotope Li-11 at the on-line isotope separators at GSI, Darmstadt, Germany and at TRIUMF, Vancouver, Canada. We describe the laser spectroscopic method in detail, present updated and improved values from theory and experiment, and discuss the results.
△ Less
Submitted 17 December, 2010; v1 submitted 2 September, 2010;
originally announced September 2010.
-
Biomechanical models to simulate consequences of maxillofacial surgery
Authors:
Yohan Payan,
Matthieu Chabanas,
Xavier Pelorson,
Coriandre Vilain,
Patrick Levy,
Vincent Luboz,
Pascal Perrier
Abstract:
This paper presents the biomechanical finite element models that have been developed in the framework of the computer-assisted maxillofacial surgery. After a brief overview of the continuous elastic modelling method, two models are introduced and their use for computer-assisted applications discussed. The first model deals with orthognathic surgery and aims at predicting the facial consequences…
▽ More
This paper presents the biomechanical finite element models that have been developed in the framework of the computer-assisted maxillofacial surgery. After a brief overview of the continuous elastic modelling method, two models are introduced and their use for computer-assisted applications discussed. The first model deals with orthognathic surgery and aims at predicting the facial consequences of maxillary and mandibular osteotomies. For this, a generic three-dimensional model of the face is automatically adapted to the morphology of the patient by the mean of elastic registration. Qualitative simulations of the consequences of an osteotomy of the mandible can thus be provided. The second model addresses the Sleep Apnoea Syndrome. Its aim is to develop a complete modelling of the interaction between airflow and upper airways walls during respiration. Dynamical simulations of the interaction during a respiratory cycle are computed and compared with observed phenomena.
△ Less
Submitted 16 June, 2006;
originally announced June 2006.
-
Nuclear Charge Radius of Li-9, Li-11: Halo Neutron: the influence of Halo Neutrons
Authors:
R. Sánchez,
W. Nörtershäuser,
G. Ewald,
D. Albers,
J. Behr,
P. Bricault,
B. A. Bushaw,
A. Dax,
J. Dilling,
M. Dombsky,
G. W. F. Drake,
S. Götte,
R. Kirchner,
H. -J. Kluge,
Th. Kühl,
J. Lassen,
C. D. P. Levy,
M. Pearson,
E. Prime,
V. Ryjkov,
A. Wojtaszek,
Z. -C. Yan,
C. Zimmermann
Abstract:
The nuclear charge radius of Li-11 has been determined for the first time by high precision laser spectroscopy. On-line measurements at TRIUMF-ISAC yielded a Li-7 - Li-11 isotope shift (IS) of 25101.23(13) MHz for the Doppler-free 2s - 3s transition. IS precision for all other bound Li isotopes was also improved. Differences from calculated mass-based IS yield values for change in charge radius…
▽ More
The nuclear charge radius of Li-11 has been determined for the first time by high precision laser spectroscopy. On-line measurements at TRIUMF-ISAC yielded a Li-7 - Li-11 isotope shift (IS) of 25101.23(13) MHz for the Doppler-free 2s - 3s transition. IS precision for all other bound Li isotopes was also improved. Differences from calculated mass-based IS yield values for change in charge radius along the isotope chain. The charge radius decreases monotonically from Li-6 to Li-9, and then increases from 2.217(35) fm to 2.467(37) fm for Li-11. This is compared to various models, and it is found that a combination of halo neutron correlation and intrinsic core excitation best reproduces the experimental results.
△ Less
Submitted 16 November, 2005; v1 submitted 30 September, 2005;
originally announced September 2005.
-
Laser Stabilization Controls for the ISAC Beam Polarizer
Authors:
R. Nussbaumer,
D. Dale,
H. Hui,
J. Richards,
P. Levy
Abstract:
The ISAC polarized beam facility uses a Ti:Sapphire laser for producing spin-polarized beams of short-lived radioactive isotopes, initially 7Li. The laser power and spectral content must be tightly controlled and monitored. The control system to accomplish this task uses techniques that combine operator interface, data reduction, and closed loop automation. The laser stabilization application us…
▽ More
The ISAC polarized beam facility uses a Ti:Sapphire laser for producing spin-polarized beams of short-lived radioactive isotopes, initially 7Li. The laser power and spectral content must be tightly controlled and monitored. The control system to accomplish this task uses techniques that combine operator interface, data reduction, and closed loop automation. The laser stabilization application uses input data acquired from a spectrum analyzer, in the form of a waveform array repetitively acquired from a GPIB-interfaced oscilloscope. A Labview based operator interface allows the selection of features from within the waveform, which are then used as the basis for closed loop control, in concert with the existing EPICS control system software and related hardware. Part of the challenge stems from using input data which are subject to human interpretation and require distillation into a hard numeric format suitable for use in a control system.
△ Less
Submitted 9 November, 2001;
originally announced November 2001.