Skip to main content

Showing 1–9 of 9 results for author: Levy, P

Searching in archive physics. Search in all archives.
.
  1. arXiv:2103.00350  [pdf, ps, other

    cond-mat.mtrl-sci physics.app-ph

    Proton irradiation effects on metal-YBCO interfaces

    Authors: C. Acha, G. A. Sanca, M. Barella, M. Alurralde, F. Gomez Marlasca, H. Huhtinen, P. Paturi, F. Golmar, P. Levy

    Abstract: 10 MeV proton-irradiation effects on a YBCO-based test structure were analyzed by measuring its current-voltage (IV) characteristics for different cumulated fluences. For fluences of up to $\sim$80$\cdot$10$^9$~p/cm$^2$ no changes in the electrical behavior of the device were observed, while for a fluence of $\sim$~300$\cdot$10$^9~$ p/cm$^2$ it becomes less conducting. A detailed analysis of the r… ▽ More

    Submitted 27 February, 2021; originally announced March 2021.

    Comments: 22 pages, 7 figures, corresponding author: [email protected]

    Journal ref: Radiation Physics and Chemistry (2021)

  2. arXiv:2007.00143  [pdf

    physics.ins-det physics.app-ph

    COTS MOS Dosimetry on the MeMOSat Board, Results After 2.5 Years in Orbit

    Authors: José Lipovetzky, Mariano Garcia-Inza, Macarena Rodríguez Cañete, Gabriel Redin, Sebastián Carbonetto, Martín Echarri, Federico Golmar, Fernando Gomez Marlasca, Mariano Barella, Gabriel A. Sanca, Pablo Levy, Adrián Faigón

    Abstract: We present the results after 2.5 years in or-bit of Total Ionizing Dose (TID) measurements done using Metal Oxide Semiconductor (MOS) dosimeters on the MeMOSat board. The MeMOSat board was launched on July 19th 2014 at the BugSat-1 "Tita" microsatellite developed by Satellogic to stay at LEO. We used as dosimeters p-channel Commercial Off The Shelf (COTS) MOS transistors with gate oxides of 250~nm… ▽ More

    Submitted 30 June, 2020; originally announced July 2020.

  3. arXiv:2007.00141  [pdf

    physics.ins-det physics.app-ph physics.space-ph

    LabOSat as a versatile payload for small satellites: first 100days in LEO orbit

    Authors: G. A. Sanca, M. Barella, F. Gomez Marlasca, G. Rodríguez, D. Martelliti, L. Patrone, P. Levy, F. Golmar

    Abstract: In this work the first results obtained by LabOSat-01 platform are presented. This platform was designed for testing custom devices on board of small satellites. Two LabOSat-01 type boards were launched and placed into Low Earth Orbit (LEO) on May 30, 2016. We present here an analysis of data collected by one of these boards during the first days of mission. Total Ionization Dose results are compa… ▽ More

    Submitted 30 June, 2020; originally announced July 2020.

  4. arXiv:2006.15062  [pdf, ps, other

    physics.app-ph cond-mat.mtrl-sci

    YBCO-based non-volatile ReRAM tested in Low Earth Orbit

    Authors: C. Acha, M. Barella, G. A. Sanca, F. Gomez Marlasca, H. Huhtinen, P. Paturi, P. Levy, F. Golmar

    Abstract: An YBCO-based test structure corresponding to the family of ReRAM devices associated with the valence change mechanism is presented. We have characterized its electrical response previous to its lift-off to a Low Earth Orbit (LEO) using standard electronics and also with the dedicated LabOSat-01 controller. Similar results were obtained in both cases. After about 200 days at LEO on board a small s… ▽ More

    Submitted 26 June, 2020; originally announced June 2020.

    Comments: 20 pages, 11 figures

    Journal ref: Journal of Materials Science: Materials in Electronics (2020)

  5. arXiv:1907.03684  [pdf, other

    cond-mat.soft physics.chem-ph

    The dynamics of liquid 1-ethyl-3-methylimidazolium acetate measured with implanted-ion $^8$Li $β$-NMR

    Authors: Derek Fujimoto, Ryan M. L. McFadden, Martin H. Dehn, Yael Petel, Aris Chatzichristos, Lars Hemmingsen, Victoria L. Karner, Robert F. Kiefl, C. D. Philip Levy, Iain McKenzie, Carl A. Michal, Gerald D. Morris, Matthew R. Pearson, Daniel Szunyogh, John O. Ticknor, Monika Stachura, W. Andrew MacFarlane

    Abstract: We demonstrate the application of implanted-ion $β$-detected NMR as a probe of ionic liquid molecular dynamics through the measurement of $^8$Li spin-lattice relaxation (SLR) and resonance in 1-ethyl-3-methylimidazolium acetate. The motional narrowing of the resonance, and the local maxima in the SLR rate, $1/T_1$, imply a sensitivity to sub-nanosecond Li$^+$ solvation dynamics. From an analysis o… ▽ More

    Submitted 31 October, 2019; v1 submitted 8 July, 2019; originally announced July 2019.

    Journal ref: Chem. Mater. 31, 9346 (2019)

  6. arXiv:1009.0393  [pdf, ps, other

    physics.atom-ph nucl-ex

    Isotope Shift Measurements of Stable and Short-Lived Lithium Isotopes for Nuclear Charge Radii Determination

    Authors: W. Nörtershäuser, R. Sánchez, G. Ewald, A. Dax, J. Behr, P. Bricault, B. A. Bushaw, J. Dilling, M. Dombsky, G. W. F. Drake, S. Götte, H. -J. Kluge, Th. Kühl, J. Lassen, C. D. P. Levy, K. Pachucki, M. Pearson, M. Puchalski, A. Wojtaszek, Z. -C. Yan, C. Zimmermann

    Abstract: Changes in the mean-square nuclear charge radii along the lithium isotopic chain were determined using a combination of precise isotope shift measurements and theoretical atomic structure calculations. Nuclear charge radii of light elements are of high interest due to the appearance of the nuclear halo phenomenon in this region of the nuclear chart. During the past years we have developed a new la… ▽ More

    Submitted 17 December, 2010; v1 submitted 2 September, 2010; originally announced September 2010.

    Comments: 34 pages, 24 figures, 14 tables

  7. arXiv:physics/0606146  [pdf

    physics.med-ph

    Biomechanical models to simulate consequences of maxillofacial surgery

    Authors: Yohan Payan, Matthieu Chabanas, Xavier Pelorson, Coriandre Vilain, Patrick Levy, Vincent Luboz, Pascal Perrier

    Abstract: This paper presents the biomechanical finite element models that have been developed in the framework of the computer-assisted maxillofacial surgery. After a brief overview of the continuous elastic modelling method, two models are introduced and their use for computer-assisted applications discussed. The first model deals with orthognathic surgery and aims at predicting the facial consequences… ▽ More

    Submitted 16 June, 2006; originally announced June 2006.

    Journal ref: C. R. Biologies 325 (2002) 407-417

  8. Nuclear Charge Radius of Li-9, Li-11: Halo Neutron: the influence of Halo Neutrons

    Authors: R. Sánchez, W. Nörtershäuser, G. Ewald, D. Albers, J. Behr, P. Bricault, B. A. Bushaw, A. Dax, J. Dilling, M. Dombsky, G. W. F. Drake, S. Götte, R. Kirchner, H. -J. Kluge, Th. Kühl, J. Lassen, C. D. P. Levy, M. Pearson, E. Prime, V. Ryjkov, A. Wojtaszek, Z. -C. Yan, C. Zimmermann

    Abstract: The nuclear charge radius of Li-11 has been determined for the first time by high precision laser spectroscopy. On-line measurements at TRIUMF-ISAC yielded a Li-7 - Li-11 isotope shift (IS) of 25101.23(13) MHz for the Doppler-free 2s - 3s transition. IS precision for all other bound Li isotopes was also improved. Differences from calculated mass-based IS yield values for change in charge radius… ▽ More

    Submitted 16 November, 2005; v1 submitted 30 September, 2005; originally announced September 2005.

    Comments: 5 pages, 2 figures

  9. arXiv:physics/0111081  [pdf

    physics.acc-ph

    Laser Stabilization Controls for the ISAC Beam Polarizer

    Authors: R. Nussbaumer, D. Dale, H. Hui, J. Richards, P. Levy

    Abstract: The ISAC polarized beam facility uses a Ti:Sapphire laser for producing spin-polarized beams of short-lived radioactive isotopes, initially 7Li. The laser power and spectral content must be tightly controlled and monitored. The control system to accomplish this task uses techniques that combine operator interface, data reduction, and closed loop automation. The laser stabilization application us… ▽ More

    Submitted 9 November, 2001; originally announced November 2001.

    Comments: ICALEPS01 TUAP065

    Journal ref: eConf C011127 (2001) THAP065