Sparse channel sampling for ultrasound localization microscopy (SPARSE-ULM)
Authors:
Erwan Hardy,
Jonathan Poree,
Hatim Belgharbi,
Chloe Bourquin,
Frederic Lesage,
Jean Provost
Abstract:
Ultrasound Localization Microscopy (ULM) has recently enabled the mapping of the cerebral vasculature in vivo with a resolution ten times smaller than the wavelength used, down to ten microns. However, with frame rates up to 20.000 frames per second, this method requires large amount of data to be acquired, transmitted, stored, and processed. The transfer rate is, as of today, one of the main limi…
▽ More
Ultrasound Localization Microscopy (ULM) has recently enabled the mapping of the cerebral vasculature in vivo with a resolution ten times smaller than the wavelength used, down to ten microns. However, with frame rates up to 20.000 frames per second, this method requires large amount of data to be acquired, transmitted, stored, and processed. The transfer rate is, as of today, one of the main limiting factors of this technology. Herein, we introduce a novel reconstruction framework to decrease this quantity of data to be acquired and the complexity of the required hardware by randomly subsampling the channels of a linear probe. Method performance evaluation as well as parameters optimization were conducted in silico using the SIMUS simulation software in an anatomically realistic phantom and then compared to in vivo acquisitions in a rat brain after craniotomy. Results show that reducing the number of active elements deteriorates the signal-to-noise ratio and could lead to false microbubbles detections but has limited effect on localization accuracy. In simulation, the false positive rate on microbubble detection deteriorates from 3.7% for 128 channels in receive and 7 steered angles to 11% for 16 channels and 7 angles. The average localization accuracy ranges from 10.6 um and 9.93 um for 16 channels/3 angles and 128 channels/13 angles respectively. These results suggest that a compromise can be found between the number of channels and the quality of the reconstructed vascular network and demonstrate feasibility of performing ULM with a reduced number of channels in receive, paving the way for low-cost devices enabling high-resolution vascular mapping.
△ Less
Submitted 19 October, 2023;
originally announced October 2023.
-
Quantitative pulsatility measurements using 3D Dynamic Ultrasound Localization Microscopy
Authors:
Chloé Bourquin,
Jonathan Porée,
Brice Rauby,
Vincent Perrot,
Nin Ghigo,
Hatim Belgharbi,
Samuel Bélanger,
Gerardo Ramos-Palacios,
Nelson Cortés,
Hugo Ladret,
Lamyae Ikan,
Christian Casanova,
Frédéric Lesage,
Jean Provost
Abstract:
A rise in blood flow velocity variations (i.e., pulsatility) in the brain, caused by the stiffening of upstream arteries, is associated with cognitive impairment and neurodegenerative diseases. The study of this phenomenon requires brain-wide pulsatility measurements, with high penetration depth and high spatiotemporal resolution. The development of Dynamic Ultrasound Localization Microscopy (DULM…
▽ More
A rise in blood flow velocity variations (i.e., pulsatility) in the brain, caused by the stiffening of upstream arteries, is associated with cognitive impairment and neurodegenerative diseases. The study of this phenomenon requires brain-wide pulsatility measurements, with high penetration depth and high spatiotemporal resolution. The development of Dynamic Ultrasound Localization Microscopy (DULM), based on ULM, has enabled pulsatility measurements in the rodent brain in 2D. However, 2D imaging accesses only one slice of the brain and measures biased velocities due to 2D projection. Herein, we present 3D DULM, which can extract quantitative pulsatility measurements in the cat brain with craniotomy and in the whole mouse brain through the skull, showing a wide range of flow hemodynamics in both large and small vessels. We highlighted a decrease in pulsatility along the vascular tree in the cat brain, and performed an intra-animal validation of the method by showing consistent measurements between the two sides of the Willis circle in the mouse brain. Our study provides the first step towards a new biomarker that would allow the detection of dynamic abnormalities in microvessels in the whole brain volume, which could be linked to early signs of neurodegenerative diseases.
△ Less
Submitted 24 March, 2023;
originally announced March 2023.
-
Generation of Shear Waves by Laser in Soft Media in the Ablative and Thermoelastic Regimes
Authors:
Pol Grasland-Mongrain,
Yuankang Lu,
Frederic Lesage,
Stefan Catheline,
Guy Cloutier
Abstract:
This article describes the generation of elastic shear waves in a soft medium using a laser beam. Our experiments show two different regimes depending on laser energy. Physical modeling of the underlying phenomena reveals a thermoelastic regime caused by a local dilatation resulting from temperature increase, and an ablative regime caused by a partial vaporization of the medium by the laser. Compu…
▽ More
This article describes the generation of elastic shear waves in a soft medium using a laser beam. Our experiments show two different regimes depending on laser energy. Physical modeling of the underlying phenomena reveals a thermoelastic regime caused by a local dilatation resulting from temperature increase, and an ablative regime caused by a partial vaporization of the medium by the laser. Computed theoretical displacements are close to experimental measurements. A numerical study based on the physical modeling gives propagation patterns comparable to those generated experimentally. These results provide a physical basis for the feasibility of a shear wave elastography technique (a technique which measures a soft solid stiffness from shear wave propagation) by using a laser beam.
△ Less
Submitted 23 April, 2018;
originally announced April 2018.
-
Influence of gas flow rate on liquid distribution in trickle-beds using perforated plates as liquid distributors
Authors:
Juan-David Llamas,
François Lesage,
Gabriel Wild
Abstract:
Two wire mesh tomography devices and a liquid collector were used to study the influence of the gas flow rate on liquid distribution when fluids distribution on top of the reactor is ensured by a perforated plate. In opposition to most of the studies realized by other authors, conditions in which the gas has a negative impact in liquid distribution were evidenced. Indeed, the obtained results sh…
▽ More
Two wire mesh tomography devices and a liquid collector were used to study the influence of the gas flow rate on liquid distribution when fluids distribution on top of the reactor is ensured by a perforated plate. In opposition to most of the studies realized by other authors, conditions in which the gas has a negative impact in liquid distribution were evidenced. Indeed, the obtained results show that the influence of gas flow rate depends on the quality of the initial distribution, as the gas forces the liquid to "respect" the distribution imposed at the top of the reactor. Finally, a comparison between the two measuring techniques shows the limitations of the liquid collector and the improper conclusions to which its use could lead.
△ Less
Submitted 27 May, 2008;
originally announced May 2008.