-
The Single-Phase ProtoDUNE Technical Design Report
Authors:
B. Abi,
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
D. L. Adams,
P. Adamson,
M. Adinolfi,
Z. Ahmad,
C. H. Albright,
T. Alion,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. P. Andrews,
R. A. Andrews,
J. dos Anjos,
A. Ankowski,
J. Anthony,
M. Antonello,
A. Aranda Fernandez,
A. Ariga,
T. Ariga,
E. Arrieta Diaz,
J. Asaadi
, et al. (806 additional authors not shown)
Abstract:
ProtoDUNE-SP is the single-phase DUNE Far Detector prototype that is under construction and will be operated at the CERN Neutrino Platform (NP) starting in 2018. ProtoDUNE-SP, a crucial part of the DUNE effort towards the construction of the first DUNE 10-kt fiducial mass far detector module (17 kt total LAr mass), is a significant experiment in its own right. With a total liquid argon (LAr) mass…
▽ More
ProtoDUNE-SP is the single-phase DUNE Far Detector prototype that is under construction and will be operated at the CERN Neutrino Platform (NP) starting in 2018. ProtoDUNE-SP, a crucial part of the DUNE effort towards the construction of the first DUNE 10-kt fiducial mass far detector module (17 kt total LAr mass), is a significant experiment in its own right. With a total liquid argon (LAr) mass of 0.77 kt, it represents the largest monolithic single-phase LArTPC detector to be built to date. It's technical design is given in this report.
△ Less
Submitted 27 July, 2017; v1 submitted 21 June, 2017;
originally announced June 2017.
-
Design and Construction of the MicroBooNE Detector
Authors:
MicroBooNE Collaboration,
R. Acciarri,
C. Adams,
R. An,
A. Aparicio,
S. Aponte,
J. Asaadi,
M. Auger,
N. Ayoub,
L. Bagby,
B. Baller,
R. Barger,
G. Barr,
M. Bass,
F. Bay,
K. Biery,
M. Bishai,
A. Blake,
V. Bocean,
D. Boehnlein,
V. D. Bogert,
T. Bolton,
L. Bugel,
C. Callahan,
L. Camilleri
, et al. (215 additional authors not shown)
Abstract:
This paper describes the design and construction of the MicroBooNE liquid argon time projection chamber and associated systems. MicroBooNE is the first phase of the Short Baseline Neutrino program, located at Fermilab, and will utilize the capabilities of liquid argon detectors to examine a rich assortment of physics topics. In this document details of design specifications, assembly procedures, a…
▽ More
This paper describes the design and construction of the MicroBooNE liquid argon time projection chamber and associated systems. MicroBooNE is the first phase of the Short Baseline Neutrino program, located at Fermilab, and will utilize the capabilities of liquid argon detectors to examine a rich assortment of physics topics. In this document details of design specifications, assembly procedures, and acceptance tests are reported.
△ Less
Submitted 17 January, 2017; v1 submitted 17 December, 2016;
originally announced December 2016.
-
Automated Fourier space region-recognition filtering for off-axis digital holographic microscopy
Authors:
Xuefei He,
Chuong Vinh Nguyen,
Mrinalini Pratap,
Yujie Zheng,
Yi Wang,
David R. Nisbet,
Richard J Williams,
Melanie Rug,
Alexander G. Maier,
Woei Ming Lee
Abstract:
Automated label-free quantitative imaging of biological samples can greatly benefit high throughput diseases diagnosis. Digital holographic microscopy (DHM) is a powerful quantitative label-free imaging tool that retrieves structural details of cellular samples non-invasively. In off-axis DHM, a proper spatial filtering window in Fourier space is crucial to the quality of reconstructed phase image…
▽ More
Automated label-free quantitative imaging of biological samples can greatly benefit high throughput diseases diagnosis. Digital holographic microscopy (DHM) is a powerful quantitative label-free imaging tool that retrieves structural details of cellular samples non-invasively. In off-axis DHM, a proper spatial filtering window in Fourier space is crucial to the quality of reconstructed phase image. Here we describe a region-recognition approach that combines shape recognition with an iterative thresholding to extracts the optimal shape of frequency components. The region recognition technique offers fully automated adaptive filtering that can operate with a variety of samples and imaging conditions. When imaging through optically scattering biological hydrogel matrix, the technique surpasses previous histogram thresholding techniques without requiring any manual intervention. Finally, we automate the extraction of the statistical difference of optical height between malaria parasite infected and uninfected red blood cells. The method described here pave way to greater autonomy in automated DHM imaging for imaging live cell in thick cell cultures.
△ Less
Submitted 15 July, 2016;
originally announced July 2016.
-
Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report Volume 1: The LBNF and DUNE Projects
Authors:
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
P. Adamson,
S. Adhikari,
Z. Ahmad,
C. H. Albright,
T. Alion,
E. Amador,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. Andrews,
R. Andrews,
I. Anghel,
J. d. Anjos,
A. Ankowski,
M. Antonello,
A. ArandaFernandez,
A. Ariga,
T. Ariga,
D. Aristizabal,
E. Arrieta-Diaz,
K. Aryal
, et al. (780 additional authors not shown)
Abstract:
This document presents the Conceptual Design Report (CDR) put forward by an international neutrino community to pursue the Deep Underground Neutrino Experiment at the Long-Baseline Neutrino Facility (LBNF/DUNE), a groundbreaking science experiment for long-baseline neutrino oscillation studies and for neutrino astrophysics and nucleon decay searches. The DUNE far detector will be a very large modu…
▽ More
This document presents the Conceptual Design Report (CDR) put forward by an international neutrino community to pursue the Deep Underground Neutrino Experiment at the Long-Baseline Neutrino Facility (LBNF/DUNE), a groundbreaking science experiment for long-baseline neutrino oscillation studies and for neutrino astrophysics and nucleon decay searches. The DUNE far detector will be a very large modular liquid argon time-projection chamber (LArTPC) located deep underground, coupled to the LBNF multi-megawatt wide-band neutrino beam. DUNE will also have a high-resolution and high-precision near detector.
△ Less
Submitted 20 January, 2016;
originally announced January 2016.
-
First measurement of muon-neutrino disappearance in NOvA
Authors:
P. Adamson,
C. Ader,
M. Andrews,
N. Anfimov,
I. Anghel,
K. Arms,
E. Arrieta-Diaz,
A. Aurisano,
D. Ayres,
C. Backhouse,
M. Baird,
B. A. Bambah,
K. Bays,
R. Bernstein,
M. Betancourt,
V. Bhatnagar,
B. Bhuyan,
J. Bian,
K. Biery,
T. Blackburn,
V. Bocean,
D. Bogert,
A. Bolshakova,
M. Bowden,
C. Bower
, et al. (235 additional authors not shown)
Abstract:
This paper reports the first measurement using the NOvA detectors of $ν_μ$ disappearance in a $ν_μ$ beam. The analysis uses a 14 kton-equivalent exposure of $2.74 \times 10^{20}$ protons-on-target from the Fermilab NuMI beam. Assuming the normal neutrino mass hierarchy, we measure $Δm^{2}_{32}=(2.52^{+0.20}_{-0.18})\times 10^{-3}$ eV$^{2}$ and $\sin^2θ_{23}$ in the range 0.38-0.65, both at the 68%…
▽ More
This paper reports the first measurement using the NOvA detectors of $ν_μ$ disappearance in a $ν_μ$ beam. The analysis uses a 14 kton-equivalent exposure of $2.74 \times 10^{20}$ protons-on-target from the Fermilab NuMI beam. Assuming the normal neutrino mass hierarchy, we measure $Δm^{2}_{32}=(2.52^{+0.20}_{-0.18})\times 10^{-3}$ eV$^{2}$ and $\sin^2θ_{23}$ in the range 0.38-0.65, both at the 68% confidence level, with two statistically-degenerate best fit points at $\sin^2θ_{23} = $ 0.43 and 0.60. Results for the inverted mass hierarchy are also presented.
△ Less
Submitted 20 January, 2016; v1 submitted 19 January, 2016;
originally announced January 2016.
-
First measurement of electron neutrino appearance in NOvA
Authors:
P. Adamson,
C. Ader,
M. Andrews,
N. Anfimov,
I. Anghel,
K. Arms,
E. Arrieta-Diaz,
A. Aurisano,
D. S. Ayres,
C. Backhouse,
M. Baird,
B. A. Bambah,
K. Bays,
R. Bernstein,
M. Betancourt,
V. Bhatnagar,
B. Bhuyan,
J. Bian,
K. Biery,
T. Blackburn,
V. Bocean,
D. Bogert,
A. Bolshakova,
M. Bowden,
C. Bower
, et al. (235 additional authors not shown)
Abstract:
We report results from the first search for $ν_μ\toν_e$ transitions by the NOvA experiment. In an exposure equivalent to $2.74\times10^{20}$ protons-on-target in the upgraded NuMI beam at Fermilab, we observe 6 events in the Far Detector, compared to a background expectation of $0.99\pm0.11$ (syst.) events based on the Near Detector measurement. A secondary analysis observes 11 events with a backg…
▽ More
We report results from the first search for $ν_μ\toν_e$ transitions by the NOvA experiment. In an exposure equivalent to $2.74\times10^{20}$ protons-on-target in the upgraded NuMI beam at Fermilab, we observe 6 events in the Far Detector, compared to a background expectation of $0.99\pm0.11$ (syst.) events based on the Near Detector measurement. A secondary analysis observes 11 events with a background of $1.07\pm0.14$ (syst.). The $3.3σ$ excess of events observed in the primary analysis disfavors $0.1π< δ_{CP} < 0.5π$ in the inverted mass hierarchy at the 90% C.L.
△ Less
Submitted 2 May, 2016; v1 submitted 19 January, 2016;
originally announced January 2016.
-
Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report, Volume 4 The DUNE Detectors at LBNF
Authors:
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
P. Adamson,
S. Adhikari,
Z. Ahmad,
C. H. Albright,
T. Alion,
E. Amador,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. Andrews,
R. Andrews,
I. Anghel,
J. d. Anjos,
A. Ankowski,
M. Antonello,
A. ArandaFernandez,
A. Ariga,
T. Ariga,
D. Aristizabal,
E. Arrieta-Diaz,
K. Aryal
, et al. (779 additional authors not shown)
Abstract:
A description of the proposed detector(s) for DUNE at LBNF
A description of the proposed detector(s) for DUNE at LBNF
△ Less
Submitted 12 January, 2016;
originally announced January 2016.
-
Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report Volume 2: The Physics Program for DUNE at LBNF
Authors:
DUNE Collaboration,
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
P. Adamson,
S. Adhikari,
Z. Ahmad,
C. H. Albright,
T. Alion,
E. Amador,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. Andrews,
R. Andrews,
I. Anghel,
J. d. Anjos,
A. Ankowski,
M. Antonello,
A. ArandaFernandez,
A. Ariga,
T. Ariga,
D. Aristizabal,
E. Arrieta-Diaz
, et al. (780 additional authors not shown)
Abstract:
The Physics Program for the Deep Underground Neutrino Experiment (DUNE) at the Fermilab Long-Baseline Neutrino Facility (LBNF) is described.
The Physics Program for the Deep Underground Neutrino Experiment (DUNE) at the Fermilab Long-Baseline Neutrino Facility (LBNF) is described.
△ Less
Submitted 22 January, 2016; v1 submitted 18 December, 2015;
originally announced December 2015.
-
Identifying signature Zernike modes for efficient light delivery through brain tissue
Authors:
Sharmila Sane,
Julian Choy,
Woei Ming Lee,
Christian Stricker,
Hans Bachor,
Vincent Daria
Abstract:
Recent progress in neuroscience to image and investigate brain function has been made possible by impressive developments in optogenetic and opto-molecular tools. Such research requires advances in optical techniques for the delivery of light through brain tissue with high spatial resolution. The tissue causes distortions of the wavefront of the incoming light which broadens the focus, thereby red…
▽ More
Recent progress in neuroscience to image and investigate brain function has been made possible by impressive developments in optogenetic and opto-molecular tools. Such research requires advances in optical techniques for the delivery of light through brain tissue with high spatial resolution. The tissue causes distortions of the wavefront of the incoming light which broadens the focus, thereby reducing the intensity and resolution especially in techniques requiring focal illumination. Adaptive wavefront correction has been demonstrated to compensate for these distortions. However, in many situations iterative derivation of the corrective wavefront introduces time constraints that limit its usefulness when used to probe living cells. Here we demonstrate a direct and fast technique by working with a small set of Zernike modes and demonstrate that corrections derived a priori can lead to significant improvement of the focus. We verify this idea by the electrical response of whole-cell patched neurons following two-photon photolysis of caged neurotransmitters along its dendrites.In particular, we find that the organization of the neuropile in the cortical region of rat brain slicesprovide sufficient a priori information to preselect an effective wavefront correction.
△ Less
Submitted 25 November, 2015;
originally announced November 2015.
-
Reinventing Pocket Microscopy
Authors:
T. Kamal,
X. F. He,
W. M. Lee
Abstract:
The key to the success of pocket microscopes stems from the convenience for anyone to magnify the fine details (tens of micrometres) of any object on-thespot. The capability with a portable microscope lets us surpass our limited vision and is commonly used in many areas of science, industry, education. The growth of imaging and computing power in smartphones is creating the possibility of converti…
▽ More
The key to the success of pocket microscopes stems from the convenience for anyone to magnify the fine details (tens of micrometres) of any object on-thespot. The capability with a portable microscope lets us surpass our limited vision and is commonly used in many areas of science, industry, education. The growth of imaging and computing power in smartphones is creating the possibility of converting your smartphone into a high power pocket microscope. In this article, we briefly describe the history of pocket microscopy and elucidate how mobile technologies are set to become the next platform for pocket microscopes
△ Less
Submitted 1 July, 2015;
originally announced July 2015.
-
The D0 Run II Impact Parameter Trigger
Authors:
T. Adams,
Q. An,
K. M. Black,
T. Bose,
N. J. Buchanan,
S. Caron,
D. K. Cho,
S. Choi,
A. Das,
M. Das,
H. Dong,
W. Earle,
H. Evans,
S. N. Fatakia,
L. Feligioni,
T. Fitzpatrick,
E. Hazen,
U. Heintz,
K. Herner,
J. D. Hobbs,
D. Khatidze,
W. M. Lee,
S. L. Linn,
M. Narain,
C. Pancake
, et al. (18 additional authors not shown)
Abstract:
Many physics topics to be studied by the D0 experiment during Run II of the Fermilab Tevatron ppbar collider give rise to final states containing b--flavored particles. Examples include Higgs searches, top quark production and decay studies, and full reconstruction of B decays. The sensitivity to such modes has been significantly enhanced by the installation of a silicon based vertex detector as…
▽ More
Many physics topics to be studied by the D0 experiment during Run II of the Fermilab Tevatron ppbar collider give rise to final states containing b--flavored particles. Examples include Higgs searches, top quark production and decay studies, and full reconstruction of B decays. The sensitivity to such modes has been significantly enhanced by the installation of a silicon based vertex detector as part of the DO detector upgrade for Run II. Interesting events must be identified initially in 100-200 microseconds to be available for later study. This paper describes custom electronics used in the DO trigger system to provide the real--time identification of events having tracks consistent with the decay of b--flavored particles.
△ Less
Submitted 17 January, 2007;
originally announced January 2007.
-
Experimental observation of optical vortex evolution in a Gaussian beam with an embedded fractional phase step
Authors:
W. M. Lee,
X. -C. Yuan,
K. Dholakia
Abstract:
We detect the vortex evolution from the increase of the fractional phase step by interfering two beams of opposite but equal fractional step increment.The interference pattern generated shows evidence of the birth of an additional single extra charge as the fractional phase step increase extends above a half-integer value
We detect the vortex evolution from the increase of the fractional phase step by interfering two beams of opposite but equal fractional step increment.The interference pattern generated shows evidence of the birth of an additional single extra charge as the fractional phase step increase extends above a half-integer value
△ Less
Submitted 21 May, 2004; v1 submitted 24 March, 2004;
originally announced March 2004.