-
The novel properties of SF$_6$ for directional dark matter experiments
Authors:
N. S. Phan,
R. Lafler,
R. J. Lauer,
E. R. Lee,
D. Loomba,
J. A. J. Matthews,
E. H. Miller
Abstract:
SF$_{6}$ is an inert and electronegative gas that has a long history of use in high voltage insulation and numerous other industrial applications. Although SF$_{6}$ is used as a trace component to introduce stability in tracking chambers, its highly electronegative properties have limited its use in tracking detectors. In this work we present a series of measurements with SF$_{6}$ as the primary g…
▽ More
SF$_{6}$ is an inert and electronegative gas that has a long history of use in high voltage insulation and numerous other industrial applications. Although SF$_{6}$ is used as a trace component to introduce stability in tracking chambers, its highly electronegative properties have limited its use in tracking detectors. In this work we present a series of measurements with SF$_{6}$ as the primary gas in a low pressure Time Projection Chamber (TPC), with a thick GEM used as the avalanche and readout device. The first results of an $^{55}$Fe energy spectrum in SF$_{6}$ are presented. Measurements of the mobility and longitudinal diffusion confirm the negative ion drift of SF$_{6}$. However, the observed waveforms have a peculiar but interesting structure that indicates multiple drift species and a dependence on the reduced field ($E/p$), as well as on the level of water vapor contamination. The discovery of a distinct secondary peak in the waveform, together with its identification and use for fiducializing events in the TPC, are also presented. Our measurements demonstrate that SF$_{6}$ is an ideal gas for directional dark matter detection. In particular, the high fluorine content is desirable for spin-dependent sensitivity, negative ion drift ensures low diffusion over large drift distances, and the multiple species of charge carriers allow for full detector fiducialization.
△ Less
Submitted 20 December, 2016; v1 submitted 16 September, 2016;
originally announced September 2016.
-
GEM-based TPC with CCD Imaging for Directional Dark Matter Detection
Authors:
N. S. Phan,
R. J. Lauer,
E. R. Lee,
D. Loomba,
J. A. J. Matthews,
E. H. Miller
Abstract:
The world's leading directional dark matter experiments currently all utilize low-pressure gas Time Projection Chamber (TPC) technologies. We discuss some of the challenges for this technology, for which balancing the goal of achieving the best sensitivity with that of cost effective scale-up requires optimization over a large parameter space. Critical for this are the precision measurements of th…
▽ More
The world's leading directional dark matter experiments currently all utilize low-pressure gas Time Projection Chamber (TPC) technologies. We discuss some of the challenges for this technology, for which balancing the goal of achieving the best sensitivity with that of cost effective scale-up requires optimization over a large parameter space. Critical for this are the precision measurements of the fundamental properties of both electron and nuclear recoil tracks down to the lowest detectable energies. Such measurements are necessary to provide a benchmark for background discrimination and directional sensitivity that could be used for future optimization studies for directional dark matter experiments. In this paper we describe a small, high resolution, high signal- to-noise GEM-based TPC with a 2D CCD readout designed for this goal. The performance of the detector was characterized using alpha particles, X-rays, gamma-rays, and neutrons, enabling detailed measurements of electron and nuclear recoil tracks. Stable effective gas gains of greater than $1 \times 10^5$ were obtained in 100 Torr of pure CF$_4$ by a cascade of three standard CERN GEMs each with a 140 $μ$m pitch. The high signal-to-noise and sub-millimeter spatial resolution of the GEM amplification and CCD readout, together with low diffusion, allow for excellent background discrimination between electron and nuclear recoils down below $\sim$10 keVee ($\sim$23 keVr fluorine recoil). Even lower thresholds, necessary for the detection of low mass WIMPs for example, might be achieved by lowering the pressure and utilizing full 3D track reconstruction. These and other paths for improvements are discussed, as are possible fundamental limitations imposed by the physics of energy loss.
△ Less
Submitted 22 September, 2016; v1 submitted 7 October, 2015;
originally announced October 2015.
-
Reducing DRIFT Backgrounds with a Submicron Aluminized-Mylar Cathode
Authors:
James B. R. Battat,
Ed Daw,
Alexei Dorofeev,
Anthony C. Ezeribe,
Jennifer R. Fox,
Jean-Luc Gauvreau,
Michael Gold,
Lydia Harmon,
John Harton,
Randy Lafler,
Robert J. Lauer,
Eric R. Lee,
Dinesh Loomba,
Alexander Lumnah,
John Matthews,
Eric H. Miller,
Frederic Mouton,
Alexander St. J. Murphy,
Nguyen Phan,
Stephen W. Sadler,
Andrew Scarff,
Fred Schuckman II,
Daniel Snowden-Ifft,
Neil J. C. Spooner,
Daniel Walker
Abstract:
Background events in the DRIFT-IId dark matter detector, mimicking potential WIMP signals, are predominantly caused by alpha decays on the central cathode in which the alpha particle is completely or partially absorbed by the cathode material. We installed a 0.9 micron thick aluminized-mylar cathode as a way to reduce the probability of producing these backgrounds. We study three generations of ca…
▽ More
Background events in the DRIFT-IId dark matter detector, mimicking potential WIMP signals, are predominantly caused by alpha decays on the central cathode in which the alpha particle is completely or partially absorbed by the cathode material. We installed a 0.9 micron thick aluminized-mylar cathode as a way to reduce the probability of producing these backgrounds. We study three generations of cathode (wire, thin-film, and radiologically clean thin-film) with a focus on the ratio of background events to alpha decays. Two independent methods of measuring the absolute alpha decay rate are used to ensure an accurate result, and agree to within $10\%$. Using alpha range spectroscopy, we measure the radiologically cleanest cathode version to have a contamination of $3.3\pm0.1$ ppt $^{234}$U and $73\pm2$ ppb $^{238}$U. This cathode reduces the probability of producing an RPR from an alpha decay by a factor of $70\pm20$ compared to the original stainless steel wire cathode. First results are presented from a texturized version of the cathode, intended to be even more transparent to alpha particles. These efforts, along with other background reduction measures, have resulted in a drop in the observed background rate from 500/day to 1/day. With the recent implementation of full-volume fiducialization, these remaining background events are identified, allowing for background-free operation.
△ Less
Submitted 1 May, 2015; v1 submitted 11 February, 2015;
originally announced February 2015.