-
Laser Resonance Ionization Spectroscopy of Thorium
Authors:
Ruohong Li,
Yuan Liu,
Dan W. Stracener,
Jens Lassen
Abstract:
High-lying Rydberg and autoionizing (AI) states of thorium (Th) have been studied via resonance laser ionization spectroscopy at both TRIUMF Canada's particle accelerator centre and Oak Ridge National Lab (ORNL). Multiple Rydberg series converging to the ionization potential (IP) were observed via different stepwise laser excitation schemes and were assigned to be the $6d^27s (^4F_{3/2})$ $np$,…
▽ More
High-lying Rydberg and autoionizing (AI) states of thorium (Th) have been studied via resonance laser ionization spectroscopy at both TRIUMF Canada's particle accelerator centre and Oak Ridge National Lab (ORNL). Multiple Rydberg series converging to the ionization potential (IP) were observed via different stepwise laser excitation schemes and were assigned to be the $6d^27s (^4F_{3/2})$ $np$, $nd$, and $nf$ series. Analysis of these series enabled the determination of the IP to be 50868.735(54) cm$^{-1}$, which improved the precision by two orders of magnitude over the current adopted NIST value of 50867(2) cm$^{-1}$. Additionally, four AI Rydberg series were identified and assigned to $nf$ and $nd$ series converging to the $6d^27s$ $^4F_{5/2}$ and $6d^27s$ $^2D_{3/2}$ metastable states of Th$^+$. The measured energies of the Rydberg and AI Rydberg states are reported, and observed perturbations within the series are discussed.
△ Less
Submitted 8 August, 2025;
originally announced August 2025.
-
Two-step laser resonant ionization spectroscopy of chromium
Authors:
Romina Schulz,
Ruohong Li,
Julius Wessolek,
Maryam Mostamand,
Peter Kunz,
Jens Lassen
Abstract:
At TRIUMF's off-line laser ion source test stand, stepwise resonant laser ionization spectroscopy of chromium (Cr) was carried out, to find an efficient ionization scheme suitable for titanium sapphire (Ti:Sa) laser systems. With three different first-excitation transitions, 357.971 nm, 359.451 nm, and 360.636 nm, automated continuous laser-frequency scans using a frequency-doubled, grating-tuned…
▽ More
At TRIUMF's off-line laser ion source test stand, stepwise resonant laser ionization spectroscopy of chromium (Cr) was carried out, to find an efficient ionization scheme suitable for titanium sapphire (Ti:Sa) laser systems. With three different first-excitation transitions, 357.971 nm, 359.451 nm, and 360.636 nm, automated continuous laser-frequency scans using a frequency-doubled, grating-tuned Ti:Sa laser were performed. Rydberg series as well as autoionizing(AI) states were observed. From these results, the ionization potential (IP) of Cr was determined as 54575.49(2)$_\text{stat}$(2)$_\text{sys}$ cm$^{-1}$, which is one order of magnitude more precise than the previously reported 54575.6(3) cm$^{-1}$ in NIST database. The ionization scheme using the observed AI resonance, with 357.971 nm as the first step and 373.935 nm as the second step was subsequently deployed to the online delivery of radioactive Cr isotope beams for precision mass measurements. The online yields of $^{50-59}$Cr have been measured at TRIUMF-ISAC.
△ Less
Submitted 22 April, 2025;
originally announced April 2025.
-
Collinear laser spectroscopy on neutron-rich actinium isotopes
Authors:
Ruohong Li,
Andrea Teigelhöfer,
Jiguang Li,
Jacek Bieroń,
András Gácsbaranyi,
Jake Johnson,
Per Jönsson,
Victoria Karner,
Mingxuan Ma,
Martin Radulov,
Mathias Roman,
Monika Stachura,
Jens Lassen
Abstract:
High-resolution collinear laser spectroscopy of neutron-rich actinium has been performed at TRIUMF's isotope separator and accelerator facility ISAC. By probing the $7s^2~^1S_0$ $\rightarrow$ $6d7p~^1P_1$ ionic transition, the hyperfine structures and optical isotope shifts in $^{225, 226, 228, 229}\!$Ac$^+$ have been measured. This allows precise determinations of the changes in mean-square charg…
▽ More
High-resolution collinear laser spectroscopy of neutron-rich actinium has been performed at TRIUMF's isotope separator and accelerator facility ISAC. By probing the $7s^2~^1S_0$ $\rightarrow$ $6d7p~^1P_1$ ionic transition, the hyperfine structures and optical isotope shifts in $^{225, 226, 228, 229}\!$Ac$^+$ have been measured. This allows precise determinations of the changes in mean-square charge radii, magnetic dipole moments, and electric quadrupole moments of these actinium isotopes. The improved precision of charge radii and magnetic moments clears the ambiguity in the odd-even staggering from previous studies. The electric quadrupole moments of $^{225, 226, 228, 229}\!$Ac are determined for the first time.
△ Less
Submitted 17 March, 2025;
originally announced March 2025.
-
RF phase effect in the ion-guide laser ion source (IG-LIS)
Authors:
Ruohong Li,
Maryam Mostamand,
Jens Lassen
Abstract:
The effect of the phase between the radio frequency (RF) waveform driving the ion guide and the laser pulses generating ions on the intensity of the transmitted ion beam has been studied. Experiments were conducted at TRIUMF's offline laser ion source test stand (LIS-stand) and online at the isotope separator and accelerator (ISAC) facility for radioactive ion beam delivery. In this study, a maste…
▽ More
The effect of the phase between the radio frequency (RF) waveform driving the ion guide and the laser pulses generating ions on the intensity of the transmitted ion beam has been studied. Experiments were conducted at TRIUMF's offline laser ion source test stand (LIS-stand) and online at the isotope separator and accelerator (ISAC) facility for radioactive ion beam delivery. In this study, a master clock is used to synchronize the laser trigger for laser ionization and the RF waveform generator driving the ion guide, so that laser ionization within the ionization volume inside the RF ion guide will occur at a specific RF phase which affects the ions' transmission through the RFQ. At optimal phase the ion extraction from the IG-LIS can be improved by 10-50%. Simulations were run considering both fringe field and RFQ phase effects. The method also provides an additional function of IG-LIS to modulate the laser-ionized ions at hundreds of kHz, allowing phase-sensitive detection for experiments downstream. In addition, modulation of the RF envelope (on and off like a gating device) in transmission mode allows for the suppression of surface-ionized species outside the laser-ion pulse, which provides an alternative to a classic fast kicker for beam purification.
△ Less
Submitted 12 February, 2025;
originally announced February 2025.
-
Understanding radioactive ion beam production at ISAC through yield measurements and simulations
Authors:
Peter Kunz,
Jens Lassen,
Corina Andreoiu,
Fatima H. Garcia,
Hua Yang,
Valery Radchenko
Abstract:
The high-intensity proton beam of the TRIUMF 500 MeV cyclotron offers unique opportunities to produce rare isotopes by irradiating a variety of targets. In particular, the ISAC (Isotope Separation and ACceleration) facility provides the infrastructure to deliver customized rare ion beams for fundamental research in nuclear physics, astrophysics, material science, and nuclear medicine. A continuous…
▽ More
The high-intensity proton beam of the TRIUMF 500 MeV cyclotron offers unique opportunities to produce rare isotopes by irradiating a variety of targets. In particular, the ISAC (Isotope Separation and ACceleration) facility provides the infrastructure to deliver customized rare ion beams for fundamental research in nuclear physics, astrophysics, material science, and nuclear medicine. A continuous effort is made to develop new radioactive ion beams (RIB) and improve their intensity or purity, properties that depend strongly on the type of target, operating conditions, the ion source, and beam transport efficiency. Yield data and theoretical production rates based on FLUKA and Geant4 simulations are collected in the TRIUMF Isotope Database, providing a valuable resource for RIB development and experiment planning. This paper introduces the newly upgraded TRIUMF Isotope Database and presents examples on how it's resources can be used to plan experiments and understand the origin of certain RIB. In particular we discuss the collection of 155Tb which is an important component of medical isotope research at TRIUMF.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Transuranium isotopes at ISAC/TRIUMF
Authors:
Peter Kunz,
Corina Andreoiu,
Fatima H. Garcia,
Jens Lassen
Abstract:
The production of transuranium isotopes has been demonstrated at the Isotope Separation and ACceleration (ISAC) facility. In particular a laser-ionized $^{239}$Pu beam, extracted from a uranium carbide target, was investigated. The experimental work was complemented by GEANT4 simulations, modelling the impact of secondary particles on the creation of transuranium isotopes through inelastic nuclear…
▽ More
The production of transuranium isotopes has been demonstrated at the Isotope Separation and ACceleration (ISAC) facility. In particular a laser-ionized $^{239}$Pu beam, extracted from a uranium carbide target, was investigated. The experimental work was complemented by GEANT4 simulations, modelling the impact of secondary particles on the creation of transuranium isotopes through inelastic nuclear reactions. Theoretical production cross sections were derived and compared to experimental results, leading to a discussion on boundary conditions for the release of neptunium and plutonium from ISAC uranium carbide targets.
△ Less
Submitted 25 November, 2022;
originally announced November 2022.
-
Resonance Laser Ionization Spectroscopy of Selenium
Authors:
R. Li,
Y. Liu,
M. Mostamand,
J. Lassen
Abstract:
Photoionization spectra of Se have been studied by step-wise resonance laser ionization. The Rydberg series 4s$^2$4p$^3$($^4$S)np $^3$P$_{0,1,2}$ and 4s$^2$4p$^3$($^4$S)np $^5$P$_{1,2,3}$ were measured via different excitation schemes. Using the Rydberg series 4s$^2$4p$^3$($^4$S)np $^3$P$_2$ with n=15-33, the ionization potential of Se was determined with improved precision to 76658.15(2)…
▽ More
Photoionization spectra of Se have been studied by step-wise resonance laser ionization. The Rydberg series 4s$^2$4p$^3$($^4$S)np $^3$P$_{0,1,2}$ and 4s$^2$4p$^3$($^4$S)np $^5$P$_{1,2,3}$ were measured via different excitation schemes. Using the Rydberg series 4s$^2$4p$^3$($^4$S)np $^3$P$_2$ with n=15-33, the ionization potential of Se was determined with improved precision to 76658.15(2)$_{stat}$(4)$_{sys}$ cm$^{-1}$, which resolved the discrepancy in previous literatures. Autoionizing (AI) spectra between the IP and two neighboring converging limits of the Se ionic states 4s$^2$4p$^3$($^2$D$_{3/2}$) and 4s$^2$4p$^3$($^2$D$_{5/2}$) were obtained. In total eight AI Rydberg series have been observed, measured and assigned.
△ Less
Submitted 14 July, 2020;
originally announced July 2020.
-
Polarization-dependent laser resonance ionization of beryllium
Authors:
Ruohong Li,
Maryam Mostamand,
Jekabs Romans,
Jens Lassen
Abstract:
Using TRIUMF's off-line laser ion source test stand with a system of tunable titanium sapphire lasers, the polarization dependence of laser resonance ionization has been investigated using beryllium. A significant polarization dependence was observed for the excitation path $^1$S$_0$$\rightarrow$$^1$P$^{\circ}_1$$\rightarrow$$^1$S$_0$, which are typical transitions for alkaline and alkaline-like e…
▽ More
Using TRIUMF's off-line laser ion source test stand with a system of tunable titanium sapphire lasers, the polarization dependence of laser resonance ionization has been investigated using beryllium. A significant polarization dependence was observed for the excitation path $^1$S$_0$$\rightarrow$$^1$P$^{\circ}_1$$\rightarrow$$^1$S$_0$, which are typical transitions for alkaline and alkaline-like elements. This polarization dependence was further verified on Be radioactive isotopes at TRIUMF's isotope separator and accelerator facility (ISAC). Laser polarization was proven to be an important parameter in operating resonance ionization laser ion sources (RILIS).
The polarization spectroscopy was preformed off-line both on the 2p$^2$ $^1$S$_0$ autoionizing (AI) state and high-$n$ Rydberg states of the $2sns$ $^1S_0$ and $2snd$ $^1D_2$ series. The energy of the 2p$^2$ $^1$S$_0$ AI state and ionization potential (IP) of beryllium were extracted as 76167(6)~cm$^{-1}$ and 75192.59(3)~cm$^{-1}$. Polarization spectroscopy can be used to determine the $J$ values of newly found states in in-source spectroscopy of the complex/radioactive alkaline-like elements such as Ra, Sm, Yb, Pu and No.
△ Less
Submitted 27 June, 2020;
originally announced June 2020.
-
Development of a continuously tunable titanium-sapphire laser system for the ARIEL laser ion source
Authors:
Bianca Bettina Reich,
Maryam Mostamand,
Ruohong Li,
Jens Lassen
Abstract:
A concept for continuously tunable titanium-sapphire (Ti:Sa) lasers using dispersion prisms is under investigation for the ARIEL (Advanced Rare IsotopE Laboratory) laser ion source at TRIUMF (Canada's particle accelerator center). Wavelength selection for pulsed Ti:Sa lasers used in hot cavity laser resonance ionization spectroscopy is usually done with birefringent filters (BRFs) and etalons or d…
▽ More
A concept for continuously tunable titanium-sapphire (Ti:Sa) lasers using dispersion prisms is under investigation for the ARIEL (Advanced Rare IsotopE Laboratory) laser ion source at TRIUMF (Canada's particle accelerator center). Wavelength selection for pulsed Ti:Sa lasers used in hot cavity laser resonance ionization spectroscopy is usually done with birefringent filters (BRFs) and etalons or diffraction gratings. For resonance ionization spectroscopy a laser system allowing a continuous wavelength scan is necessary. Tunable lasers based on BRFs and etalons have high output powers however require synchronized optimization for continuous laser wavelength scans and are therefore laborious to use in scanning applications. Diffraction grating tuned lasers can provide continuous wavelength scan over 200 nm range but typically have lower output laser power due to the grating deformation under high pumping power. Aiming to overcome both shortcomings a laser design based on prisms as dispersing element has been revisited. Simulations on the beam path and optical reflectivity are done which show that these losses can be minimized to around 0.04 % for a tuning range from 700 nm up to 920 nm. Further improvement on the tuning range and reduction on the linewidth will be pursued.
△ Less
Submitted 27 January, 2020;
originally announced January 2020.
-
Production of clean rare isotope beams at TRIUMF Ion guide laser ion source
Authors:
M. Mostamand,
R. Li,
J. Romans,
F. Ames,
P. Kunz,
A. Mjos,
J. Lassen
Abstract:
Hot cavity resonant ionization laser ion sources (RILIS) provide a multitude of radioactive ion beams with high ionization efficiency and element selective ionization. However, in hot cavity RILIS there still remains isobaric contaminations in the extracted beam from surface ionized species. An ion guide-laser ion source (IG-LIS) has been implemented that decouples the hot isotope production regio…
▽ More
Hot cavity resonant ionization laser ion sources (RILIS) provide a multitude of radioactive ion beams with high ionization efficiency and element selective ionization. However, in hot cavity RILIS there still remains isobaric contaminations in the extracted beam from surface ionized species. An ion guide-laser ion source (IG-LIS) has been implemented that decouples the hot isotope production region from the laser ionization volume. A number of IG-LIS runs have been conducted to provide isobar free radioactive ion beams for experiments. Isobar suppression of up to 106 has been achieved, however, IG-LIS still suffers from an intensity loss of 50-100X as compared to hot cavity RILIS. Operating parameters for IG-LIS are being optimized and design improvements are being implemented into the prototype for robust and efficient on-line operation. Recent SIMION ion optics simulation results and the ongoing development status of the IG-LIS are presented.
△ Less
Submitted 20 January, 2020;
originally announced January 2020.
-
Resonant Ionization Laser Ion Source (RILIS) Development on Lu and Pr
Authors:
R. Li,
J. Lassen,
F. Ames,
P. Kunz,
M. Mostamand,
B. B. Reich,
A. Teigelhöfer,
H. Yan
Abstract:
Resonance ionization laser ion sources are efficient and element selective ion sources, which are particularly well suited for radioactive ion beam facilities. Using TRIUMF's off-line laser ion source test stand with a system of tunable titanium sapphire (Ti:Sa) lasers, laser resonance ionization schemes for lutetium and praseodymium have been investigated with a particular interest to autoionizin…
▽ More
Resonance ionization laser ion sources are efficient and element selective ion sources, which are particularly well suited for radioactive ion beam facilities. Using TRIUMF's off-line laser ion source test stand with a system of tunable titanium sapphire (Ti:Sa) lasers, laser resonance ionization schemes for lutetium and praseodymium have been investigated with a particular interest to autoionizing states. New ionization schemes via Rydberg states and autoionizing states were found. Their investigation and comparison of ion yields at the off-line test stand will be discussed, and the data of on-line Lu delivery will be presented.
△ Less
Submitted 10 April, 2017;
originally announced April 2017.
-
Study of even-parity Rydberg and autoionizing states of lutetium by laser resonance ionization spectroscopy
Authors:
R. Li,
J. Lassen,
Z. P. Zhong,
F. D. Jia,
M. Mostamand,
X. K. Li,
B. B. Reich,
A. Teigelhöfer,
H. Yan
Abstract:
Multi-step laser resonance ionization spectroscopy of lutetium (Lu) has been performed at TRIUMF's off-line laser ion source test stand. The even-parity Rydberg series $6s^2nd$ $^2D_{3/2}$, $6s^2nd$ $^2D_{5/2}$ and $6s^2ns$ $^2S_{1/2}$ were observed converging to the 6s$^2$ ionization potential. The experimental results has been compared to previous work. 51 levels of Rydberg series $6s^2nd$…
▽ More
Multi-step laser resonance ionization spectroscopy of lutetium (Lu) has been performed at TRIUMF's off-line laser ion source test stand. The even-parity Rydberg series $6s^2nd$ $^2D_{3/2}$, $6s^2nd$ $^2D_{5/2}$ and $6s^2ns$ $^2S_{1/2}$ were observed converging to the 6s$^2$ ionization potential. The experimental results has been compared to previous work. 51 levels of Rydberg series $6s^2nd$ $^2D_{5/2}$ and 52 levels of Rydberg series $6s^2ns$ $^2S_{1/2}$ were reported new. Additionally six even-parity autoionization (AI) series converging to Lu ionic states $5d6s$ $^3D_1$ and $5d6s$ $^3D_2$ were observed. The level energies of these AI states were measured. The configurations of the AI states were assigned by relativistic multichannel theory (RMCT) within the framework of multichannel quantum defect theory (MQDT).
△ Less
Submitted 6 March, 2017; v1 submitted 27 February, 2017;
originally announced February 2017.
-
Continuously tunable pulsed Ti:Sa laser self-seeded by an extended grating cavity
Authors:
Ruohong Li,
Jens Lassen,
Sebastian Rothe,
Andrea Teigelhöfer,
Maryam Mostamand
Abstract:
A continuously tunable titanium:sapphire (Ti:Sa) laser self-seeded by an extended grating cavity was demonstrated and characterized. By inserting a partially reflecting mirror inside the cavity of a classic single-cavity grating laser, two oscillators are created: a broadband power oscillator, and a narrowband oscillator with a prism beam expander and a diffraction grating in Littrow configuration…
▽ More
A continuously tunable titanium:sapphire (Ti:Sa) laser self-seeded by an extended grating cavity was demonstrated and characterized. By inserting a partially reflecting mirror inside the cavity of a classic single-cavity grating laser, two oscillators are created: a broadband power oscillator, and a narrowband oscillator with a prism beam expander and a diffraction grating in Littrow configuration. By coupling the grating cavity oscillation into the power oscillator, a power-enhanced narrow-linewidth laser oscillation is achieved. Compared to the classic grating laser, this simple modification significantly increases the laser output power without considerably broadening the linewidth. With most of the oscillating laser power confined inside the broadband power cavity and lower power incident onto the grating, the new configuration also allows higher pump power, which is typically limited by the thermal deformation of the grating coating at high oscillation power.
△ Less
Submitted 25 November, 2016;
originally announced November 2016.
-
Offline trapping of $^{221}$Fr in a magneto-optical trap from implantation of an $^{225}$Ac ion beam
Authors:
M. Tandecki,
J. Zhang,
S. Aubin,
J. A. Behr,
R. Collister,
E. Gomez,
G. Gwinner,
H. Heggen,
J. Lassen,
L. A. Orozco,
M. R. Pearson,
S. Raeder,
A. Teigelhöfer
Abstract:
We demonstrate a new technique to prepare an offline source of francium for trapping in a magneto-optical trap. Implanting a radioactive beam of $^{225}$Ac, $t_{1/2} = 9.920(3)$ days, in a foil, allows use of the decay products, i.e.$^{221}$Fr, $t_{1/2} = 288.0(4)$ s. $^{221}$Fr is ejected from the foil by the $α$ decay of $^{225}$Ac. This technique is compatible with the online accumulation of a…
▽ More
We demonstrate a new technique to prepare an offline source of francium for trapping in a magneto-optical trap. Implanting a radioactive beam of $^{225}$Ac, $t_{1/2} = 9.920(3)$ days, in a foil, allows use of the decay products, i.e.$^{221}$Fr, $t_{1/2} = 288.0(4)$ s. $^{221}$Fr is ejected from the foil by the $α$ decay of $^{225}$Ac. This technique is compatible with the online accumulation of a laser-cooled atomic francium sample for a series of planned parity non-conservation measurements at TRIUMF. We obtain a 34% release efficiency for $^{221}$Fr from the recoil source based on particle detector measurements. We find that laser cooling operation with the source is $8^{+10}_{-5}$ times less efficient than from a mass-separated ion beam of $^{221}$Fr in the current geometry. While the flux of this source is two to three orders of magnitude lower than typical francium beams from ISOL facilities, the source provides a longer-term supply of francium for offline studies.
△ Less
Submitted 30 September, 2014;
originally announced October 2014.
-
Isotope Shift Measurements of Stable and Short-Lived Lithium Isotopes for Nuclear Charge Radii Determination
Authors:
W. Nörtershäuser,
R. Sánchez,
G. Ewald,
A. Dax,
J. Behr,
P. Bricault,
B. A. Bushaw,
J. Dilling,
M. Dombsky,
G. W. F. Drake,
S. Götte,
H. -J. Kluge,
Th. Kühl,
J. Lassen,
C. D. P. Levy,
K. Pachucki,
M. Pearson,
M. Puchalski,
A. Wojtaszek,
Z. -C. Yan,
C. Zimmermann
Abstract:
Changes in the mean-square nuclear charge radii along the lithium isotopic chain were determined using a combination of precise isotope shift measurements and theoretical atomic structure calculations. Nuclear charge radii of light elements are of high interest due to the appearance of the nuclear halo phenomenon in this region of the nuclear chart. During the past years we have developed a new la…
▽ More
Changes in the mean-square nuclear charge radii along the lithium isotopic chain were determined using a combination of precise isotope shift measurements and theoretical atomic structure calculations. Nuclear charge radii of light elements are of high interest due to the appearance of the nuclear halo phenomenon in this region of the nuclear chart. During the past years we have developed a new laser spectroscopic approach to determine the charge radii of lithium isotopes which combines high sensitivity, speed, and accuracy to measure the extremely small field shift of an 8 ms lifetime isotope with production rates on the order of only 10,000 atoms/s. The method was applied to all bound isotopes of lithium including the two-neutron halo isotope Li-11 at the on-line isotope separators at GSI, Darmstadt, Germany and at TRIUMF, Vancouver, Canada. We describe the laser spectroscopic method in detail, present updated and improved values from theory and experiment, and discuss the results.
△ Less
Submitted 17 December, 2010; v1 submitted 2 September, 2010;
originally announced September 2010.
-
Nuclear Charge Radius of Li-9, Li-11: Halo Neutron: the influence of Halo Neutrons
Authors:
R. Sánchez,
W. Nörtershäuser,
G. Ewald,
D. Albers,
J. Behr,
P. Bricault,
B. A. Bushaw,
A. Dax,
J. Dilling,
M. Dombsky,
G. W. F. Drake,
S. Götte,
R. Kirchner,
H. -J. Kluge,
Th. Kühl,
J. Lassen,
C. D. P. Levy,
M. Pearson,
E. Prime,
V. Ryjkov,
A. Wojtaszek,
Z. -C. Yan,
C. Zimmermann
Abstract:
The nuclear charge radius of Li-11 has been determined for the first time by high precision laser spectroscopy. On-line measurements at TRIUMF-ISAC yielded a Li-7 - Li-11 isotope shift (IS) of 25101.23(13) MHz for the Doppler-free 2s - 3s transition. IS precision for all other bound Li isotopes was also improved. Differences from calculated mass-based IS yield values for change in charge radius…
▽ More
The nuclear charge radius of Li-11 has been determined for the first time by high precision laser spectroscopy. On-line measurements at TRIUMF-ISAC yielded a Li-7 - Li-11 isotope shift (IS) of 25101.23(13) MHz for the Doppler-free 2s - 3s transition. IS precision for all other bound Li isotopes was also improved. Differences from calculated mass-based IS yield values for change in charge radius along the isotope chain. The charge radius decreases monotonically from Li-6 to Li-9, and then increases from 2.217(35) fm to 2.467(37) fm for Li-11. This is compared to various models, and it is found that a combination of halo neutron correlation and intrinsic core excitation best reproduces the experimental results.
△ Less
Submitted 16 November, 2005; v1 submitted 30 September, 2005;
originally announced September 2005.