-
Status of the laboratory infrastructure for detector calibration and characterization at the European XFEL
Authors:
N. Raab,
K. -E. Ballak,
T. Dietze,
M. Ekmedzič,
S. Hauf,
F. Januschek,
A. Kaukher,
M. Kuster,
P. M. Lang,
A. Münnich,
R. Schmitt,
J. Sztuk-Dambietz,
M. Turcato
Abstract:
The European X-ray Free Electron Laser (XFEL.EU) will provide unprecedented peak brilliance and ultra-short and spatially coherent X-ray pulses in an energy range of 0.25 to 25 keV . The pulse timing structure is unique with a burst of 2700 pulses of 100 fs length at a temporal distance of 220 ns followed by a 99.4 ms gap. To make optimal use of this timing structure and energy range a great varie…
▽ More
The European X-ray Free Electron Laser (XFEL.EU) will provide unprecedented peak brilliance and ultra-short and spatially coherent X-ray pulses in an energy range of 0.25 to 25 keV . The pulse timing structure is unique with a burst of 2700 pulses of 100 fs length at a temporal distance of 220 ns followed by a 99.4 ms gap. To make optimal use of this timing structure and energy range a great variety of detectors are being developed for use at XFEL.EU, including 2D X-ray imaging cameras that are able to detect images at a rate of 4.5 MHz, provide dynamic ranges up to 10$^5$ photons per pulse per pixel under different operating conditions and covering a large range of angular resolution. In order to characterize, commission and calibrate this variety of detectors and for testing of detector prototypes the XFEL.EU detector group is building up an X-ray test laboratory that allows testing of detectors with X-ray photons under conditions that are as similar to the future beam line conditions at the XFEL.EU as is possible with laboratory sources. A total of four test environments provide the infrastructure for detector tests and calibration: two portable setups that utilize low power X-ray sources and radioactive isotopes, a test environment where a commercial high power X-ray generator is in use, and a pulsed X-ray/electron source which will provide pulses as short as 25 ns in XFEL.EU burst mode combined with target anodes of different materials. The status of the test environments, three of which are already in use while one is in commissioning phase, will be presented as well as first results from performance tests and characterization of the sources.
△ Less
Submitted 21 March, 2017;
originally announced March 2017.
-
Integrated Detector Control and Calibration Processing at the European XFEL
Authors:
A. Münnich,
S. Hauf,
B. C. Heisen,
F. Januschek,
M. Kuster,
P. M. Lang,
N. Raab,
T. Rüter,
J. Sztuk-Dambietz,
M. Turcato
Abstract:
The European X-ray Free Electron Laser is a high-intensity X-ray light source currently being constructed in the area of Hamburg, that will provide spatially coherent X-rays in the energy range between $0.25\,\mathrm{keV}$ and $25\,\mathrm{keV}$. The machine will deliver $10\,\mathrm{trains/s}$, consisting of up to $2700\,\mathrm{pulses}$, with a $4.5\,\mathrm{MHz}$ repetition rate. The LPD, DSSC…
▽ More
The European X-ray Free Electron Laser is a high-intensity X-ray light source currently being constructed in the area of Hamburg, that will provide spatially coherent X-rays in the energy range between $0.25\,\mathrm{keV}$ and $25\,\mathrm{keV}$. The machine will deliver $10\,\mathrm{trains/s}$, consisting of up to $2700\,\mathrm{pulses}$, with a $4.5\,\mathrm{MHz}$ repetition rate. The LPD, DSSC and AGIPD detectors are being developed to provide high dynamic-range Mpixel imaging capabilities at the mentioned repetition rates. A consequence of these detector characteristics is that they generate raw data volumes of up to $15\,\mathrm{Gbyte/s}$. In addition the detector's on-sensor memory-cell and multi-/non-linear gain architectures pose unique challenges in data correction and calibration, requiring online access to operating conditions and control settings. We present how these challenges are addressed within XFEL's control and analysis framework Karabo, which integrates access to hardware conditions, acquisition settings (also using macros) and distributed computing. Implementation of control and calibration software is mainly in Python, using self-optimizing (py) CUDA code, numpy and iPython parallels to achieve near-real time performance for calibration application.
△ Less
Submitted 8 January, 2016;
originally announced January 2016.
-
Commissioning of the PRIOR proton microscope
Authors:
D. Varentsov,
O. Antonov,
A. Bakhmutova,
C. W. Barnes,
A. Bogdanov,
C. R. Danly,
S. Efimov,
M. Endres,
A. Fertman,
A. A. Golubev,
D. H. H. Hoffmann,
B. Ionita,
A. Kantsyrev,
Ya. E. Krasik,
P. M. Lang,
I. Lomonosov,
F. G. Mariam,
N. Markov,
F. E. Merrill,
V. B. Mintsev,
D. Nikolaev,
V. Panyushkin,
M. Rodionova,
M. Schanz,
K. Schoenberg
, et al. (9 additional authors not shown)
Abstract:
Recently a new high energy proton microscopy facility PRIOR (Proton Microscope for FAIR) has been designed, constructed and successfully commissioned at GSI Helmholtzzentrum für Schwerionenforschung (Darmstadt, Germany). As a result of the experiments with 3.5-4.5 GeV proton beams delivered by the heavy ion synchrotron SIS-18 of GSI, 30 um spatial and 10 ns temporal resolutions of the proton micro…
▽ More
Recently a new high energy proton microscopy facility PRIOR (Proton Microscope for FAIR) has been designed, constructed and successfully commissioned at GSI Helmholtzzentrum für Schwerionenforschung (Darmstadt, Germany). As a result of the experiments with 3.5-4.5 GeV proton beams delivered by the heavy ion synchrotron SIS-18 of GSI, 30 um spatial and 10 ns temporal resolutions of the proton microscope have been demostrated. A new pulsed power setup for studying properties of matter under extremes has been developed for the dynamic commissioning of the PRIOR facility. This paper describes the PRIOR setup as well as the results of the first static and dynamic proton radiography experiments performed at GSI.
△ Less
Submitted 19 January, 2016; v1 submitted 17 December, 2015;
originally announced December 2015.
-
CAST solar axion search with 3^He buffer gas: Closing the hot dark matter gap
Authors:
M. Arik,
S. Aune,
K. Barth,
A. Belov,
S. Borghi,
H. Brauninger,
G. Cantatore,
J. M. Carmona,
S. A. Cetin,
J. I. Collar,
E. Da Riva,
T. Dafni,
M. Davenport,
C. Eleftheriadis,
N. Elias,
G. Fanourakis,
E. Ferrer-Ribas,
P. Friedrich,
J. Galan,
J. A. Garcia,
A. Gardikiotis,
J. G. Garza,
E. N. Gazis,
T. Geralis,
E. Georgiopoulou
, et al. (50 additional authors not shown)
Abstract:
The CERN Axion Solar Telescope (CAST) has finished its search for solar axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV. This closes the gap to the cosmological hot dark matter limit and actually overlaps with it. From the absence of excess X-rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g_ag < 3.3 x 10^{-10}…
▽ More
The CERN Axion Solar Telescope (CAST) has finished its search for solar axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV. This closes the gap to the cosmological hot dark matter limit and actually overlaps with it. From the absence of excess X-rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g_ag < 3.3 x 10^{-10} GeV^{-1} at 95% CL, with the exact value depending on the pressure setting. Future direct solar axion searches will focus on increasing the sensitivity to smaller values of g_a, for example by the currently discussed next generation helioscope IAXO.
△ Less
Submitted 15 September, 2014; v1 submitted 8 July, 2013;
originally announced July 2013.
-
Radioactive Decays in Geant4
Authors:
Steffen Hauf,
Markus Kuster,
Matej Batič,
Zane W. Bell,
Dieter H. H. Hoffmann,
Philipp M. Lang,
Stephan Neff,
Maria Grazia Pia,
Georg Weidenspointner,
Andreas Zoglauer
Abstract:
The simulation of radioactive decays is a common task in Monte-Carlo systems such as Geant4. Usually, a system either uses an approach focusing on the simulations of every individual decay or an approach which simulates a large number of decays with a focus on correct overall statistics. The radioactive decay package presented in this work permits, for the first time, the use of both methods withi…
▽ More
The simulation of radioactive decays is a common task in Monte-Carlo systems such as Geant4. Usually, a system either uses an approach focusing on the simulations of every individual decay or an approach which simulates a large number of decays with a focus on correct overall statistics. The radioactive decay package presented in this work permits, for the first time, the use of both methods within the same simulation framework - Geant4. The accuracy of the statistical approach in our new package, RDM-extended, and that of the existing Geant4 per-decay implementation (original RDM), which has also been refactored, are verified against the ENSDF database. The new verified package is beneficial for a wide range of experimental scenarios, as it enables researchers to choose the most appropriate approach for their Geant4-based application.
△ Less
Submitted 3 July, 2013;
originally announced July 2013.
-
Validation of Geant4-based Radioactive Decay Simulation
Authors:
Steffen Hauf,
Markus Kuster,
Matej Batič,
Zane W. Bell,
Dieter H. H. Hoffmann,
Philipp M. Lang,
Stephan Neff,
Maria Grazia Pia,
Georg Weidenspointner,
Andreas Zoglauer
Abstract:
Radioactive decays are of concern in a wide variety of applications using Monte-Carlo simulations. In order to properly estimate the quality of such simulations, knowledge of the accuracy of the decay simulation is required. We present a validation of the original Geant4 Radioactive Decay Module, which uses a per-decay sampling approach, and of an extended package for Geant4-based simulation of ra…
▽ More
Radioactive decays are of concern in a wide variety of applications using Monte-Carlo simulations. In order to properly estimate the quality of such simulations, knowledge of the accuracy of the decay simulation is required. We present a validation of the original Geant4 Radioactive Decay Module, which uses a per-decay sampling approach, and of an extended package for Geant4-based simulation of radioactive decays, which, in addition to being able to use a refactored per-decay sampling, is capable of using a statistical sampling approach. The validation is based on measurements of calibration isotope sources using a high purity Germanium (HPGe) detector; no calibration of the simulation is performed. For the considered validation experiment equivalent simulation accuracy can be achieved with per-decay and statistical sampling.
△ Less
Submitted 21 June, 2013;
originally announced June 2013.