-
Aggregation dynamics of methacrylate binary and ternary biomimetic polymers in solution
Authors:
Garima Rani,
Kenichi Kuroda,
Satyavani Vemparala
Abstract:
Using detailed atomistic simulations,we explore the conformational landscape of aggregates formed by biomimetic antimicrobial(AM) binary methacrylate copolymers,with hydrophobic and charged functional groups and the role of inclusion of polar functional groups on such aggregate morphologies.The effect of sequence of the constituent functional groups on aggregate conformation is also studied by con…
▽ More
Using detailed atomistic simulations,we explore the conformational landscape of aggregates formed by biomimetic antimicrobial(AM) binary methacrylate copolymers,with hydrophobic and charged functional groups and the role of inclusion of polar functional groups on such aggregate morphologies.The effect of sequence of the constituent functional groups on aggregate conformation is also studied by considering random and block sequences along the polymer backbone.Our results suggest that block binary copolymers form large spherical aggregates with effective shielding of hydrophobic groups by charged groups.In contrast, random binary copolymers tend to form more bundle-like structures with exposed hydrophobic groups.The strong aggregation of binary polymers is driven primarily by attractive interactions between hydrophobic groups.However,replacing some of the hydrophobic groups with overall charge neutral polar groups weakens the aggregate considerably, leading to increased conformational fluctuations and formation of loose-packed,open aggregates,particularly in case of random ternary polymers.Interaction energy calculations strongly suggest that the role of inclusion of polar groups is two-fold: (1)to reduce possible strong local concentration of hydrophobic groups and smear the hydrophobicity along the polymer backbone to increase the solubility of the polymers (2)to compensate the loss of attractive hydrophobic interactions by forming attractive electrostatic interactions with charged groups and contribute to aggregation formation,albeit weak.Given that most of the naturally occurring AM peptides have contributions from all the three functional groups,this study elucidates the functionally tuneable role of inclusion of polar groups in the way AM agents interact with each other in solution phase,which can eventually dictate their partitioning behavior into bacterial and mammalian membranes.
△ Less
Submitted 22 February, 2020;
originally announced February 2020.
-
Construction of KAGRA: an Underground Gravitational Wave Observatory
Authors:
T. Akutsu,
M. Ando,
S. Araki,
A. Araya,
T. Arima,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
L. Baiotti,
M. A. Barton,
D. Chen,
K. Cho,
K. Craig,
R. DeSalvo,
K. Doi,
K. Eda,
Y. Enomoto,
R. Flaminio,
S. Fujibayashi,
Y. Fujii,
M. -K. Fujimoto,
M. Fukushima,
T. Furuhata
, et al. (202 additional authors not shown)
Abstract:
Major construction and initial-phase operation of a second-generation gravitational-wave detector KAGRA has been completed. The entire 3-km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferomet…
▽ More
Major construction and initial-phase operation of a second-generation gravitational-wave detector KAGRA has been completed. The entire 3-km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferometer operation has been installed and the first test run was accomplished in March and April of 2016 with a rather simple configuration. The initial configuration of KAGRA is named {\it iKAGRA}. In this paper, we summarize the construction of KAGRA, including the study of the advantages and challenges of building an underground detector and the operation of the iKAGRA interferometer together with the geophysics interferometer that has been constructed in the same tunnel.
△ Less
Submitted 11 December, 2017; v1 submitted 30 November, 2017;
originally announced December 2017.
-
Twisted Radiation by Electrons in Spiral Motion
Authors:
M. Katoh,
M. Fujimoto,
N. S. Mirian,
T. Konomi,
Y. Taira,
T. Kaneyasu,
M. Hosaka,
N. Yamamoto,
A. Mochihashi,
Y. Takashima,
K. Kuroda,
A. Miyamoto,
K. Miyamoto,
S. Sasaki
Abstract:
We theoretically show that a single free electron in circular/spiral motion radiates an electromagnetic wave possessing helical phase structure and carrying orbital angular momentum. We experimentally demonstrate it by double-slit diffraction on radiation from relativistic electrons in spiral motion. We show that twisted photons should be created naturally by cyclotron/synchrotron radiations or Co…
▽ More
We theoretically show that a single free electron in circular/spiral motion radiates an electromagnetic wave possessing helical phase structure and carrying orbital angular momentum. We experimentally demonstrate it by double-slit diffraction on radiation from relativistic electrons in spiral motion. We show that twisted photons should be created naturally by cyclotron/synchrotron radiations or Compton scatterings in various situations in cosmic space. We propose promising laboratory vortex photon sources in various wavelengths ranging from radio wave to gamma-rays.
△ Less
Submitted 15 September, 2016; v1 submitted 12 September, 2016;
originally announced September 2016.
-
A Study of Cooling Time Reduction of Interferometric Cryogenic Gravitational Wave Detectors Using a High-Emissivity Coating
Authors:
Y. Sakakibara,
N. Kimura,
T. Suzuki,
K. Yamamoto,
D. Chen,
S. Koike,
C. Tokoku,
T. Uchiyama,
M. Ohashi,
K. Kuroda
Abstract:
In interferometric cryogenic gravitational wave detectors, there are plans to cool mirrors and their suspension systems (payloads) in order to reduce thermal noise, that is, one of the fundamental noise sources. Because of the large payload masses (several hundred kg in total) and their thermal isolation, a cooling time of several months is required. Our calculation shows that a high-emissivity co…
▽ More
In interferometric cryogenic gravitational wave detectors, there are plans to cool mirrors and their suspension systems (payloads) in order to reduce thermal noise, that is, one of the fundamental noise sources. Because of the large payload masses (several hundred kg in total) and their thermal isolation, a cooling time of several months is required. Our calculation shows that a high-emissivity coating (e.g. a diamond-like carbon (DLC) coating) can reduce the cooling time effectively by enhancing radiation heat transfer. Here, we have experimentally verified the effect of the DLC coating on the reduction of the cooling time.
△ Less
Submitted 18 September, 2013;
originally announced September 2013.
-
Effect of energy deposited by cosmic-ray particles on interferometric gravitational wave detectors
Authors:
Kazuhiro Yamamoto,
Hideaki Hayakawa,
Atsushi Okada,
Takashi Uchiyama,
Shinji Miyoki,
Masatake Ohashi,
Kazuaki Kuroda,
Nobuyuki Kanda,
Daisuke Tatsumi,
Yoshiki Tsunesada
Abstract:
We investigated the noise of interferometric gravitational wave detectors due to heat energy deposited by cosmic-ray particles. We derived a general formula that describes the response of a mirror against a cosmic-ray passage. We found that there are differences in the comic-ray responses (the dependence of temperature and cosmic-ray track position) in cases of interferometric and resonant gravi…
▽ More
We investigated the noise of interferometric gravitational wave detectors due to heat energy deposited by cosmic-ray particles. We derived a general formula that describes the response of a mirror against a cosmic-ray passage. We found that there are differences in the comic-ray responses (the dependence of temperature and cosmic-ray track position) in cases of interferometric and resonant gravitational wave detectors. The power spectral density of vibrations caused by low-energy secondary muons is 100-times smaller than the goal sensitivity of future second-generation interferometer projects, such as LCGT and Advanced LIGO. The arrival frequency of high-energy cosmic-ray muons that generate enough large showers inside mirrors of LCGT and Advanced LIGO is one per a millennium. We also discuss the probability of exotic-particle detection with interferometers.
△ Less
Submitted 3 August, 2008; v1 submitted 15 May, 2008;
originally announced May 2008.
-
Parametric instabilities in the LCGT arm cavity
Authors:
K Yamamoto,
T Uchiyama,
S Miyoki,
M Ohashi,
K Kuroda,
K Numata
Abstract:
We evaluated the parametric instabilities of LCGT (Japanese interferometric gravitational wave detector project) arm cavity. The number of unstable modes of LCGT is 10-times smaller than that of Advanced LIGO (U.S.A.). Since the strength of the instabilities of LCGT depends on the mirror curvature more weakly than that of Advanced LIGO, the requirement of the mirror curvature accuracy is easier…
▽ More
We evaluated the parametric instabilities of LCGT (Japanese interferometric gravitational wave detector project) arm cavity. The number of unstable modes of LCGT is 10-times smaller than that of Advanced LIGO (U.S.A.). Since the strength of the instabilities of LCGT depends on the mirror curvature more weakly than that of Advanced LIGO, the requirement of the mirror curvature accuracy is easier to be achieved. The difference in the parametric instabilities between LCGT and Advanced LIGO is because of the thermal noise reduction methods (LCGT, cooling sapphire mirrors; Advanced LIGO, fused silica mirrors with larger laser beams), which are the main strategies of the projects. Elastic Q reduction by the barrel surface (0.2 mm thickness Ta$_2$O$_5$) coating is effective to suppress instabilities in the LCGT arm cavity. Therefore, the cryogenic interferometer is a smart solution for the parametric instabilities in addition to thermal noise and thermal lensing.
△ Less
Submitted 15 May, 2008;
originally announced May 2008.
-
Current status of the CLIO project
Authors:
K Yamamoto,
T Uchiyama,
S Miyoki,
M Ohashi,
K Kuroda,
H Ishitsuka,
T Akutsu,
S Telada,
T Tomaru,
T Suzuki,
N Sato,
Y Saito,
Y Higashi,
T Haruyama,
A Yamamoto,
T Shintomi,
D Tatsumi,
M Ando,
H Tagoshi,
N Kanda,
N Awaya,
S Yamagishi,
H Takahashi,
A Araya,
A Takamori
, et al. (5 additional authors not shown)
Abstract:
CLIO (Cryogenic Laser Interferometer Observatory) is a Japanese gravitational wave detector project. One of the main purposes of CLIO is to demonstrate thermal-noise suppression by cooling mirrors for a future Japanese project, LCGT (Large-scale Cryogenic Gravitational Telescope). The CLIO site is in Kamioka mine, as is LCGT. The progress of CLIO between 2005 and 2007 (room- and cryogenic-temper…
▽ More
CLIO (Cryogenic Laser Interferometer Observatory) is a Japanese gravitational wave detector project. One of the main purposes of CLIO is to demonstrate thermal-noise suppression by cooling mirrors for a future Japanese project, LCGT (Large-scale Cryogenic Gravitational Telescope). The CLIO site is in Kamioka mine, as is LCGT. The progress of CLIO between 2005 and 2007 (room- and cryogenic-temperature experiments) is introduced in this article. In a room-temperature experiment, we made efforts to improve the sensitivity. The current best sensitivity at 300 K is about $6 \times 10^{-21} /\sqrt{\rm Hz}$ around 400 Hz. Below 20 Hz, the strain (not displacement) sensitivity is comparable to that of LIGO, although the baselines of CLIO are 40-times shorter (CLIO: 100m, LIGO: 4km). This is because seismic noise is extremely small in Kamioka mine. We operated the interferometer at room temperature for gravitational wave observations. We obtained 86 hours of data. In the cryogenic experiment, it was confirmed that the mirrors were sufficiently cooled (14 K). However, we found that the radiation shield ducts transferred 300K radiation into the cryostat more effectively than we had expected. We observed that noise caused by pure aluminum wires to suspend a mirror was suppressed by cooling the mirror.
△ Less
Submitted 15 May, 2008;
originally announced May 2008.
-
Conduction Effect of Thermal Radiation in a Metal Shield Pipe in a Cryostat for a Cryogenic Interferometric Gravitational Wave Detector
Authors:
Takayuki Tomaru,
Masao Tokunari,
Kazuaki Kuroda,
Takashi Uchiyama,
Akira Okutomi,
Masatake Ohashi,
Hiroyuki Kirihara,
Nobuhiro Kimura,
Yoshio Saito,
Nobuaki Sato,
Takakazu Shintomi,
Toshikazu Suzuki,
Tomiyoshi Haruyama,
Shinji Miyoki,
Kazuhiro Yamamoto,
Akira Yamamoto
Abstract:
A large heat load caused by thermal radiation through a metal shield pipe was observed in a cooling test of a cryostat for a prototype of a cryogenic interferometric gravitational wave detector. The heat load was approximately 1000 times larger than the value calculated by the Stefan-Boltzmann law. We studied this phenomenon by simulation and experiment and found that it was caused by the conduc…
▽ More
A large heat load caused by thermal radiation through a metal shield pipe was observed in a cooling test of a cryostat for a prototype of a cryogenic interferometric gravitational wave detector. The heat load was approximately 1000 times larger than the value calculated by the Stefan-Boltzmann law. We studied this phenomenon by simulation and experiment and found that it was caused by the conduction of thermal radiation in a metal shield pipe.
△ Less
Submitted 6 November, 2007;
originally announced November 2007.
-
Thermal lensing in cryogenic sapphire substrates
Authors:
Takayuki Tomaru,
Toshikazu Suzuki,
Shinji Miyoki,
Takashi Uchiyama,
C. T. Taylor,
Akira Yamamoto,
Takakazu Shintomi,
Masatake Ohashi,
Kazuaki Kuroda
Abstract:
We report the reduction of the thermal lensing in cryogenic sapphire mirrors, which is planed to be used in the Large scale Cryogenic Gravitational wave Telescope (LCGT) project. We measured three key parameters of sapphire substrate for thermal lensing at cryogenic temperature. They are optical absorption coefficient, thermal conductivity and temperature coefficient of refractive index at cryog…
▽ More
We report the reduction of the thermal lensing in cryogenic sapphire mirrors, which is planed to be used in the Large scale Cryogenic Gravitational wave Telescope (LCGT) project. We measured three key parameters of sapphire substrate for thermal lensing at cryogenic temperature. They are optical absorption coefficient, thermal conductivity and temperature coefficient of refractive index at cryogenic temperature. On basis of these measurements, we estimated the shot noise sensitivity of the interferometer with thermal lensing by using a wave-front tracing simulation. We found that thermal lensing in cryogenic sapphire mirrors is negligible.
△ Less
Submitted 12 February, 2002;
originally announced February 2002.
-
Cryogenic measurement of the optical absorption coefficient in sapphire crystals at 1.064(micro)m for the Large-scale Cryogenic Gravitational wave Telescope
Authors:
Takayuki Tomaru,
Takashi Uchiyama,
Daisuke Tatsumi,
Shinji Miyoki,
Masatake Ohashi,
Kazuaki Kuroda,
Toshikazu Suzuki,
Akira Yamamoto,
Takakazu Shintomi
Abstract:
We have applied laser calorimetry to the measurement of optical absorption in mono-crystalline sapphire at cryogenic temperatures. Sapphire is a promising candidate for the mirror substrates of the Large-scale Cryogenic Gravitational wave Telescope. The optical absorption coefficients of different sapphire samples at a wavelength of 1.064(micro)m at 5K were found to average 90ppm/cm.
We have applied laser calorimetry to the measurement of optical absorption in mono-crystalline sapphire at cryogenic temperatures. Sapphire is a promising candidate for the mirror substrates of the Large-scale Cryogenic Gravitational wave Telescope. The optical absorption coefficients of different sapphire samples at a wavelength of 1.064(micro)m at 5K were found to average 90ppm/cm.
△ Less
Submitted 8 March, 2001; v1 submitted 17 January, 2001;
originally announced January 2001.