Skip to main content

Showing 1–11 of 11 results for author: Krohn, M

Searching in archive physics. Search in all archives.
.
  1. arXiv:2406.11937  [pdf, other

    physics.ins-det hep-ex physics.data-an

    Using graph neural networks to reconstruct charged pion showers in the CMS High Granularity Calorimeter

    Authors: M. Aamir, G. Adamov, T. Adams, C. Adloff, S. Afanasiev, C. Agrawal, C. Agrawal, A. Ahmad, H. A. Ahmed, S. Akbar, N. Akchurin, B. Akgul, B. Akgun, R. O. Akpinar, E. Aktas, A. Al Kadhim, V. Alexakhin, J. Alimena, J. Alison, A. Alpana, W. Alshehri, P. Alvarez Dominguez, M. Alyari, C. Amendola, R. B. Amir , et al. (550 additional authors not shown)

    Abstract: A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadr… ▽ More

    Submitted 18 December, 2024; v1 submitted 17 June, 2024; originally announced June 2024.

    Journal ref: JINST 19 (2024) P11025

  2. arXiv:2211.04740  [pdf, other

    physics.ins-det

    Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20$-$300 GeV/c

    Authors: B. Acar, G. Adamov, C. Adloff, S. Afanasiev, N. Akchurin, B. Akgün, M. Alhusseini, J. Alison, J. P. Figueiredo de sa Sousa de Almeida, P. G. Dias de Almeida, A. Alpana, M. Alyari, I. Andreev, U. Aras, P. Aspell, I. O. Atakisi, O. Bach, A. Baden, G. Bakas, A. Bakshi, S. Banerjee, P. DeBarbaro, P. Bargassa, D. Barney, F. Beaudette , et al. (435 additional authors not shown)

    Abstract: The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing med… ▽ More

    Submitted 27 May, 2023; v1 submitted 9 November, 2022; originally announced November 2022.

    Comments: Accepted for publication by JINST

  3. arXiv:2111.06855  [pdf, other

    physics.ins-det hep-ex

    Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons

    Authors: B. Acar, G. Adamov, C. Adloff, S. Afanasiev, N. Akchurin, B. Akgün, F. Alam Khan, M. Alhusseini, J. Alison, A. Alpana, G. Altopp, M. Alyari, S. An, S. Anagul, I. Andreev, P. Aspell, I. O. Atakisi, O. Bach, A. Baden, G. Bakas, A. Bakshi, S. Bannerjee, P. Bargassa, D. Barney, F. Beaudette , et al. (364 additional authors not shown)

    Abstract: The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glu… ▽ More

    Submitted 31 March, 2022; v1 submitted 12 November, 2021; originally announced November 2021.

  4. Test Beam Study of SiPM-on-Tile Configurations

    Authors: A. Belloni, Y. M. Chen, A. Dyshkant, T. K. Edberg, S. Eno, V. Zutshi, J. Freeman, M. Krohn, Y. Lai, D. Lincoln, S. Los, J. Mans, G. Reichenbach, L. Uplegger, S. A. Uzunyan

    Abstract: Light yield and spatial uniformity for a large variety of configurations of scintillator tiles was studied. The light from each scintillator was collected by a Silicon Photomultiplier (SiPM) directly viewing the produced scintillation light (SiPM-on-tile technique). The varied parameters included tile transverse size, tile thickness, tile wrapping material, scintillator composition, and SiPM model… ▽ More

    Submitted 17 May, 2021; v1 submitted 16 February, 2021; originally announced February 2021.

    Comments: 19 pages, 15 figures, submitted to JINST

  5. arXiv:2012.06336  [pdf, other

    physics.ins-det hep-ex

    Construction and commissioning of CMS CE prototype silicon modules

    Authors: B. Acar, G. Adamov, C. Adloff, S. Afanasiev, N. Akchurin, B. Akgün, M. Alhusseini, J. Alison, G. Altopp, M. Alyari, S. An, S. Anagul, I. Andreev, M. Andrews, P. Aspell, I. A. Atakisi, O. Bach, A. Baden, G. Bakas, A. Bakshi, P. Bargassa, D. Barney, E. Becheva, P. Behera, A. Belloni , et al. (307 additional authors not shown)

    Abstract: As part of its HL-LHC upgrade program, the CMS Collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modul… ▽ More

    Submitted 10 December, 2020; originally announced December 2020.

    Comments: 35 pages, submitted to JINST

  6. arXiv:2012.03876  [pdf, other

    physics.ins-det hep-ex

    The DAQ system of the 12,000 Channel CMS High Granularity Calorimeter Prototype

    Authors: B. Acar, G. Adamov, C. Adloff, S. Afanasiev, N. Akchurin, B. Akgün, M. Alhusseini, J. Alison, G. Altopp, M. Alyari, S. An, S. Anagul, I. Andreev, M. Andrews, P. Aspell, I. A. Atakisi, O. Bach, A. Baden, G. Bakas, A. Bakshi, P. Bargassa, D. Barney, E. Becheva, P. Behera, A. Belloni , et al. (307 additional authors not shown)

    Abstract: The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endca… ▽ More

    Submitted 8 December, 2020; v1 submitted 7 December, 2020; originally announced December 2020.

  7. arXiv:1706.00222  [pdf, other

    physics.ins-det hep-ex

    Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector

    Authors: M. Dragicevic, M. Friedl, J. Hrubec, H. Steininger, A. Gädda, J. Härkönen, T. Lampén, P. Luukka, T. Peltola, E. Tuominen, E. Tuovinen, A. Winkler, P. Eerola, T. Tuuva, G. Baulieu, G. Boudoul, L. Caponetto, C. Combaret, D. Contardo, T. Dupasquier, G. Gallbit, N. Lumb, L. Mirabito, S. Perries, M. Vander Donckt , et al. (462 additional authors not shown)

    Abstract: A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator… ▽ More

    Submitted 1 June, 2017; originally announced June 2017.

    Report number: CMS-NOTE-2017-002

  8. Trapping in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker

    Authors: W. Adam, T. Bergauer, M. Dragicevic, M. Friedl, R. Fruehwirth, M. Hoch, J. Hrubec, M. Krammer, W. Treberspurg, W. Waltenberger, S. Alderweireldt, W. Beaumont, X. Janssen, S. Luyckx, P. Van Mechelen, N. Van Remortel, A. Van Spilbeeck, P. Barria, C. Caillol, B. Clerbaux, G. De Lentdecker, D. Dobur, L. Favart, A. Grebenyuk, Th. Lenzi , et al. (663 additional authors not shown)

    Abstract: The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determi… ▽ More

    Submitted 7 May, 2015; originally announced May 2015.

    Journal ref: 2016 JINST 11 P04023

  9. arXiv:1501.05966  [pdf, other

    physics.ins-det hep-ex

    Radiation Tolerance of 65nm CMOS Transistors

    Authors: M. Krohn, B. Bentele, J. P. Cumalat, S. R. Wagner, D. C. Christian, G. Deptuch, F. Fahim, J. Hoff, A. Shenai

    Abstract: We report on the effects of ionizing radiation on 65nm CMOS transistors held at approximately -20C during irradiation. The pattern of damage observed after a total dose of 1 Grad is similar to damage reported in room temperature exposures, but we observe less damage than was observed at room temperature.

    Submitted 24 November, 2015; v1 submitted 23 January, 2015; originally announced January 2015.

    Report number: FERMILAB-PUB-15-014-E

  10. arXiv:1402.6384  [pdf, other

    physics.ins-det hep-ex

    Testbeam and Laboratory Characterization of CMS 3D Pixel Sensors

    Authors: M. Bubna, E. Alagoz, A. Krzywda, O. Koybasi, K. Arndt, D. Bortoletto, I. Shipsey, G. Bolla, A. Kok, T. -E. Hansen, T. A. Hansen, G. U. Jensen, J. M. Brom, M. Boscardin, J. Chramowicz, J. Cumalat, G. F. Dalla Betta, M. Dinardo, A. Godshalk, M. Jones, M. D. Krohn, A. Kumar, C. M. Lei, L. Moroni, L. Perera , et al. (10 additional authors not shown)

    Abstract: The pixel detector is the innermost tracking device in CMS, reconstructing interaction vertices and charged particle trajectories. The sensors located in the innermost layers of the pixel detector must be upgraded for the ten-fold increase in luminosity expected with the High- Luminosity LHC (HL-LHC) phase. As a possible replacement for planar sensors, 3D silicon technology is under consideration… ▽ More

    Submitted 30 April, 2014; v1 submitted 25 February, 2014; originally announced February 2014.

    Comments: 14 pages

  11. arXiv:1206.1944  [pdf, other

    physics.ins-det hep-ex

    Long-Term Testing and Properties of Acrylic for the Daya Bay Antineutrino Detectors

    Authors: M. Krohn, B. R. Littlejohn, K. M. Heeger

    Abstract: The Daya Bay reactor antineutrino experiment has recently measured the neutrino mixing parameter sin22θ13 by observing electron antineutrino disappearance over kilometer-scale baselines using six antineutrino detectors at near and far distances from reactor cores at the Daya Bay nuclear power complex. Liquid scintillator contained in transparent target vessels is used to detect electron antineutri… ▽ More

    Submitted 9 June, 2012; originally announced June 2012.

    Comments: 17 pages, 13 figures Submitted to JINST