Comparison of different sensor thicknesses and substrate materials for the monolithic small collection-electrode technology demonstrator CLICTD
Authors:
Katharina Dort,
Rafael Ballabriga,
Justus Braach,
Eric Buschmann,
Michael Campbell,
Dominik Dannheim,
Lennart Huth,
Iraklis Kremastiotis,
Jens Kröger,
Lucie Linssen,
Magdalena Munker,
Walter Snoeys,
Simon Spannagel,
Peter Švihra,
Tomas Vanat
Abstract:
Small collection-electrode monolithic CMOS sensors profit from a high signal-to-noise ratio and a small power consumption, but have a limited active sensor volume due to the fabrication process based on thin high-resistivity epitaxial layers. In this paper, the active sensor depth is investigated in the monolithic small collection-electrode technology demonstrator CLICTD. Charged particle beams ar…
▽ More
Small collection-electrode monolithic CMOS sensors profit from a high signal-to-noise ratio and a small power consumption, but have a limited active sensor volume due to the fabrication process based on thin high-resistivity epitaxial layers. In this paper, the active sensor depth is investigated in the monolithic small collection-electrode technology demonstrator CLICTD. Charged particle beams are used to study the charge-collection properties and the performance of devices with different thicknesses both for perpendicular and inclined particle incidence. In CMOS sensors with a high-resistivity Czochralski substrate, the depth of the sensitive volume is found to increase by a factor two in comparison with standard epitaxial material and leads to significant improvements in the hit-detection efficiency and the spatial and time resolution.
△ Less
Submitted 30 August, 2022; v1 submitted 22 April, 2022;
originally announced April 2022.
-
Transient Monte Carlo Simulations for the Optimisation and Characterisation of Monolithic Silicon Sensors
Authors:
Rafael Ballabriga,
Justus Braach,
Eric Buschmann,
Michael Campbell,
Dominik Dannheim,
Katharina Dort,
Lennart Huth,
Iraklis Kremastiotis,
Jens Kröger,
Lucie Linssen,
Magdalena Munker,
Paul Schütze,
Walter Snoeys,
Simon Spannagel,
Tomas Vanat
Abstract:
An ever-increasing demand for high-performance silicon sensors requires complex sensor designs that are challenging to simulate and model. The combination of electrostatic finite element simulations with a transient Monte Carlo approach provides simultaneous access to precise sensor modelling and high statistics. The high simulation statistics enable the inclusion of Landau fluctuations and produc…
▽ More
An ever-increasing demand for high-performance silicon sensors requires complex sensor designs that are challenging to simulate and model. The combination of electrostatic finite element simulations with a transient Monte Carlo approach provides simultaneous access to precise sensor modelling and high statistics. The high simulation statistics enable the inclusion of Landau fluctuations and production of secondary particles, which offers a realistic simulation scenario. The transient simulation approach is an important tool to achieve an accurate time-resolved description of the sensor, which is crucial in the face of novel detector prototypes with increasingly precise timing capabilities. The simulated time resolution as a function of operating parameters as well as the full transient pulse can be monitored and assessed, which offers a new perspective on the optimisation and characterisation of silicon sensors.
In this paper, a combination of electrostatic finite-element simulations using 3D TCAD and transient Monte Carlo simulations with the Allpix Squared framework are presented for a monolithic CMOS pixel sensor with a small collection diode, that is characterised by a highly inhomogeneous, complex electric field. The results are compared to transient 3D TCAD simulations that offer a precise simulation of the transient behaviour but long computation times. Additionally, the simulations are benchmarked against test-beam data and good agreement is found for the performance parameters over a wide range of different operation conditions.
△ Less
Submitted 9 February, 2022; v1 submitted 7 February, 2022;
originally announced February 2022.
-
Performance Studies of the ATLASpix HV-MAPS Prototype for Different Substrate Resistivities
Authors:
Jens Kröger
Abstract:
The ATLASpix high-voltage monolithic active pixel sensor (HV-MAPS) was designed as a technology demonstrator for the ATLAS ITk Upgrade and the CLIC tracking detector. In this contribution new results from laboratory-based energy calibration measurements using fluorescence X-rays are presented for the ATLASpix Simple matrix. These findings are complemented by new results from test-beam studies with…
▽ More
The ATLASpix high-voltage monolithic active pixel sensor (HV-MAPS) was designed as a technology demonstrator for the ATLAS ITk Upgrade and the CLIC tracking detector. In this contribution new results from laboratory-based energy calibration measurements using fluorescence X-rays are presented for the ATLASpix Simple matrix. These findings are complemented by new results from test-beam studies with inclined tracks, in which the active charge collection depth is determined.
△ Less
Submitted 11 May, 2022; v1 submitted 26 June, 2021;
originally announced June 2021.
-
Biocompatible carbon nitride-based light-driven microswimmer propulsion in biological and ionic media with responsive on-demand drug delivery
Authors:
Varun Sridhar,
Filip Podjaski,
Yunus Alapan,
Julia Kröger,
Lars Grunenberg,
Vimal Kishore,
Bettina V. Lotsch,
Metin Sitti
Abstract:
We propose two-dimensional organic poly(heptazine imide) (PHI) carbon nitride microparticles as light-driven microswimmers in various ionic and biological media. Their demonstrated high-speed (15-23 $μ$m/s) swimming in multi-component ionic solutions with concentrations up to 1 M and without dedicated fuels is unprecedented, overcoming one of the bottlenecks of previous light-driven microswimmers.…
▽ More
We propose two-dimensional organic poly(heptazine imide) (PHI) carbon nitride microparticles as light-driven microswimmers in various ionic and biological media. Their demonstrated high-speed (15-23 $μ$m/s) swimming in multi-component ionic solutions with concentrations up to 1 M and without dedicated fuels is unprecedented, overcoming one of the bottlenecks of previous light-driven microswimmers. Such high ion tolerance is attributed to a favorable interplay between the particle's textural and structural nanoporosity and optoionic properties, facilitating ionic interactions in solutions with high salinity. Biocompatibility of the microswimmers is validated by cell viability tests with three different cell types and primary cells. The nanopores of the swimmers are loaded with a model cancer drug, doxorubicin (DOX), in high (185%) loading efficiency without passive release. Controlled drug release is reported in different pH conditions and can be triggered on-demand also by illumination. Light-triggered, boosted release of DOX and its active degradation products is demonstrated in oxygen-poor conditions using the intrinsic, environmentally sensitive and light-induced charge storage properties of PHI, which could enable future theranostic applications in oxygen-deprived tumor regions. These organic PHI microswimmers simultaneously solve the current light-driven microswimmer challenges of high ion tolerance, fuel-free high-speed propulsion in biological media, biocompatibility and controlled on-demand cargo release towards their biomedical, environmental and other potential future applications.
△ Less
Submitted 31 March, 2021;
originally announced March 2021.
-
Test-beam characterisation of the CLICTD technology demonstrator - a small collection electrode High-Resistivity CMOS pixel sensor with simultaneous time and energy measurement
Authors:
R. Ballabriga,
E. Buschmann,
M. Campbell,
D. Dannheim,
K. Dort,
N. Egidos,
L. Huth,
I. Kremastiotis,
J. Kröger,
L. Linssen,
X. Llopart,
M. Munker,
A. Nürnberg,
W. Snoeys,
S. Spannagel,
T. Vanat,
M. Vicente,
M. Williams
Abstract:
The CLIC Tracker Detector (CLICTD) is a monolithic pixel sensor. It is fabricated in a 180 nm CMOS imaging process, modified with an additional deep low-dose n-type implant to obtain full lateral depletion. The sensor features a small collection diode, which is essential for achieving a low input capacitance. The CLICTD sensor was designed as a technology demonstrator in the context of the trackin…
▽ More
The CLIC Tracker Detector (CLICTD) is a monolithic pixel sensor. It is fabricated in a 180 nm CMOS imaging process, modified with an additional deep low-dose n-type implant to obtain full lateral depletion. The sensor features a small collection diode, which is essential for achieving a low input capacitance. The CLICTD sensor was designed as a technology demonstrator in the context of the tracking detector studies for the Compact Linear Collider (CLIC). Its design characteristics are of broad interest beyond CLIC, for HL-LHC tracking detector upgrades. It is produced in two different pixel flavours: one with a continuous deep n-type implant, and one with a segmented n-type implant to ensure fast charge collection. The pixel matrix consists of $16\times128$ detection channels measuring $300 \times 30$ microns. Each detection channel is segmented into eight sub-pixels to reduce the amount of digital circuity while maintaining a small collection electrode pitch. This paper presents the characterisation results of the CLICTD sendor in a particle beam. The different pixel flavours are compared in detail by using the simultaneous time-over-threshold and time-of-arrival measurement functionalities. Most notably, a time resolution down to $(5.8 \pm 0.1)$ ns and a spatial resolution down to $(4.6 \pm 0.2)$ microns are measured. The hit detection efficiency is found to be well above 99.7% for thresholds of the order of several hundred electrons.
△ Less
Submitted 8 February, 2021;
originally announced February 2021.
-
Corryvreckan: A Modular 4D Track Reconstruction and Analysis Software for Test Beam Data
Authors:
Dominik Dannheim,
Katharina Dort,
Lennart Huth,
Daniel Hynds,
Iraklis Kremastiotis,
Jens Kröger,
Magdalena Munker,
Florian Pitters,
Paul Schütze,
Simon Spannagel,
Tomas Vanat,
Morag Williams
Abstract:
Corryvreckan is a versatile, highly configurable software with a modular structure designed to reconstruct and analyse test beam and laboratory data. It caters to the needs of the test beam community by providing a flexible offline event building facility to combine detectors with different read-out schemes, with or without trigger information, and includes the possibility to correlate data from m…
▽ More
Corryvreckan is a versatile, highly configurable software with a modular structure designed to reconstruct and analyse test beam and laboratory data. It caters to the needs of the test beam community by providing a flexible offline event building facility to combine detectors with different read-out schemes, with or without trigger information, and includes the possibility to correlate data from multiple devices based on timestamps.
Hit timing information, available with high precision from an increasing number of detectors, can be used in clustering and tracking to reduce combinatorics. Several algorithms, including an implementation of Millepede-II, are provided for offline alignment. A graphical user interface enables direct monitoring of the reconstruction progress and can be employed for quasi-online monitoring during data taking.
This work introduces the Corryvreckan framework architecture and user interface, and provides a detailed overview of the event building algorithm. The reconstruction and analysis capabilities are demonstrated with data recorded at the DESY II Test Beam Facility using the EUDAQ2 data acquisition framework with an EUDET-type beam telescope, a Timepix3 timing reference, a fine-pitch planar silicon sensor with CLICpix2 readout and the AIDA Trigger Logic Unit. The individual steps of the reconstruction chain are presented in detail.
△ Less
Submitted 13 January, 2021; v1 submitted 25 November, 2020;
originally announced November 2020.
-
Efficient Analysis of Test-beam Data with the Corryvreckan Framework
Authors:
Jens Kröger,
Lennart Huth
Abstract:
Stringent requirements are posed on the the next generations of vertex and tracking detectors for high-energy physics experiments to reach the foreseen physics goals. A large variety of silicon pixel sensors targeting the specific needs of each use case are developed and tested both in laboratory and test-beam measurement campaigns. Corryvreckan is a flexible, fast and lightweight test-beam data r…
▽ More
Stringent requirements are posed on the the next generations of vertex and tracking detectors for high-energy physics experiments to reach the foreseen physics goals. A large variety of silicon pixel sensors targeting the specific needs of each use case are developed and tested both in laboratory and test-beam measurement campaigns. Corryvreckan is a flexible, fast and lightweight test-beam data reconstruction and analysis framework based on a modular concept of the reconstruction chain. It is designed to fulfil the requirements for offline event building in complex data-taking environments combining detectors with different readout schemes. Its modular architecture separates the framework core from the implementation of reconstruction, analysis and detector specific algorithms. In this paper, a brief overview of the software framework and the reconstruction and analysis chain is provided. This is complemented by an example analysis of a data set using the offline event building capabilities of the framework and an improved event building scheme allowing for a more efficient usage of test-beam data exploiting the pivot pixel information of the Mimosa26 sensors.
△ Less
Submitted 9 February, 2021; v1 submitted 18 November, 2020;
originally announced November 2020.
-
Adjoint Complement to the Volume-of-Fluid Method for Immiscible Flows
Authors:
Niklas Kühl,
Jörn Kröger,
Martin Siebenborn,
Michael Hinze,
Thomas Rung
Abstract:
The paper is concerned with an adjoint complement to the Volume-of-Fluid (VoF) method for immiscible two-phase flows, e.g. air and water, which is widely used in marine engineering due to its computational efficiency. The particular challenge of the primal and the corresponding adjoint VoF-approach refers to the sharp interface treatment featuring discontinuous physical properties. Both the contin…
▽ More
The paper is concerned with an adjoint complement to the Volume-of-Fluid (VoF) method for immiscible two-phase flows, e.g. air and water, which is widely used in marine engineering due to its computational efficiency. The particular challenge of the primal and the corresponding adjoint VoF-approach refers to the sharp interface treatment featuring discontinuous physical properties. Both the continuous adjoint two-phase system (integration-by-parts) and the corresponding dual compressive convection schemes (summation-by-parts) are derived for two prominent compressive convection schemes, namely the High Resolution Interface Capturing Scheme (HRIC) and Compressive Interface Capturing Scheme for Arbitrary Meshes (CICSAM). The dual scheme rigorously mirrors the primal Normalized-Variable-Diagram (NVD) stencils. Attention is restricted to steady state applications. Thus both the primal and the dual procedures are performed in pseudo time and the backward integration of the dual approach is performed around the (pseudo-temporal) converged primal field. The paper analyses the primal and adjoint equations for an engineering model problem. An analytical solution to the model problem is initially presented, which displays that the adjoint part does not offer a unique, non-trivial solution. As a remedy, an additional diffusive concentration term is introduced to the adjoint concentration equation. Numerical results obtained from the modified approach are benchmarked against the analytical solution for the model problem. Supplementary, the influence of the modification on the sensitivities obtained from simulations for the two-dimensional flow around a submerged hydrofoil are discussed. The final application refers to a shape-optimization of a generic 3D underwater vehicle and underlines a negligible influence of the free mobility parameter.
△ Less
Submitted 6 September, 2020;
originally announced September 2020.
-
Silicon Pixel R&D for the CLIC Tracking Detector
Authors:
Jens Kröger
Abstract:
The physics aims at the proposed high-energy $e^+e^-$ collider CLIC pose challenging demands on the performance of the detector system. Precise hit-time tagging, an excellent spatial resolutions, and a low mass are required for the vertex and tracking detectors. To meet these requirements, an all-silicon vertex and tracking detector system is foreseen, for which a broad R&D programme on a variety…
▽ More
The physics aims at the proposed high-energy $e^+e^-$ collider CLIC pose challenging demands on the performance of the detector system. Precise hit-time tagging, an excellent spatial resolutions, and a low mass are required for the vertex and tracking detectors. To meet these requirements, an all-silicon vertex and tracking detector system is foreseen, for which a broad R&D programme on a variety of novel silicon detector technologies is being pursued. For the ultra-low mass vertex detector, different hybrid technologies with innovative sensor concepts and interconnection techniques are explored. For the large-scale tracking detector, the focus of the R&D lies on monolithic HV-MAPS and HR-CMOS technologies. This contribution gives an overview of the ongoing activities with a focus on monolithic technologies for the CLIC tracking detector. Recent results from laboratory and test-beam measurement campaigns of the ATLASpix_Simple and the CLICTD sensor prototypes are presented.
△ Less
Submitted 20 May, 2020; v1 submitted 2 May, 2020;
originally announced May 2020.
-
MuPix and ATLASPix -- Architectures and Results
Authors:
A. Schöning,
J. Anders,
H. Augustin,
M. Benoit,
N. Berger,
S. Dittmeier,
F. Ehrler,
A. Fehr,
T. Golling,
S. Gonzalez Sevilla,
J. Hammerich,
A. Herkert,
L. Huth,
G. Iacobucci,
D. Immig,
M. Kiehn,
J. Kröger,
F. Meier,
A. Meneses Gonzalez,
A. Miucci,
L. O. S. Noehte,
I. Peric,
M. Prathapan,
T. Rudzki,
R. Schimassek
, et al. (7 additional authors not shown)
Abstract:
High Voltage Monolithic Active Pixel Sensors (HV-MAPS) are based on a commercial High Voltage CMOS process and collect charge by drift inside a reversely biased diode. HV-MAPS represent a promising technology for future pixel tracking detectors. Two recent developments are presented. The MuPix has a continuous readout and is being developed for the Mu3e experiment whereas the ATLASPix is being dev…
▽ More
High Voltage Monolithic Active Pixel Sensors (HV-MAPS) are based on a commercial High Voltage CMOS process and collect charge by drift inside a reversely biased diode. HV-MAPS represent a promising technology for future pixel tracking detectors. Two recent developments are presented. The MuPix has a continuous readout and is being developed for the Mu3e experiment whereas the ATLASPix is being developed for LHC applications with a triggered readout. Both variants have a fully monolithic design including state machines, clock circuitries and serial drivers. Several prototypes and design variants were characterised in the lab and in testbeam campaigns to measure efficiencies, noise, time resolution and radiation tolerance. Results from recent MuPix and ATLASPix prototypes are presented and prospects for future improvements are discussed.
△ Less
Submitted 17 February, 2020;
originally announced February 2020.
-
User Manual for the Corryvreckan Test Beam Data Reconstruction Framework, Version 1.0
Authors:
Jens Kröger,
Simon Spannagel,
Morag Williams
Abstract:
Test beam data reconstruction is a task that requires a large amount of flexibility due to the heterogeneous data acquisition environments found in these experiments. Often, detectors with different readout schemes such as triggered, frame-based or data driven approaches are combined in a single setup. In order to correlate these data and to reconstruct particle tracks, a versatile event building…
▽ More
Test beam data reconstruction is a task that requires a large amount of flexibility due to the heterogeneous data acquisition environments found in these experiments. Often, detectors with different readout schemes such as triggered, frame-based or data driven approaches are combined in a single setup. In order to correlate these data and to reconstruct particle tracks, a versatile event building algorithm and analysis framework is required. Corryvreckan is a flexible, fast and lightweight test beam data reconstruction framework based on a modular concept of the reconstruction chain. It is written in modern C++ , requires a minimum of external dependencies and is designed to be fully configurable by the user without the need to alter code. This document presents the user manual of the software as of release version 1.0.
△ Less
Submitted 2 December, 2019;
originally announced December 2019.
-
Performance of the large scale HV-CMOS pixel sensor MuPix8
Authors:
H. Augustin,
N. Berger,
C. Blattgerste,
S. Dittmeier,
F. Ehrler,
C Grzesik,
J. Hammerich. A. Herkert,
L. Huth,
D. Immig,
A. Kozlinskiy,
M. Köppel,
J. Kröger,
F. Meier,
A. Meneses Gonzales,
M. Müller,
L. Noehte,
I. Perić,
M. Prathapan,
T. Rudzki,
R. Schimassek,
A. Schöning,
I. Sorokin,
F. Stieler,
A. Tyukin,
T. Wagner
, et al. (4 additional authors not shown)
Abstract:
The Mu3e experiment is searching for the charged lepton flavour violating decay $ μ^+\rightarrow e^+ e^- e^+ $, aiming for an ultimate sensitivity of one in $10^{16}$ decays. In an environment of up to $10^9$ muon decays per second the detector needs to provide precise vertex, time and momentum information to suppress accidental and physics background. The detector consists of cylindrical layers o…
▽ More
The Mu3e experiment is searching for the charged lepton flavour violating decay $ μ^+\rightarrow e^+ e^- e^+ $, aiming for an ultimate sensitivity of one in $10^{16}$ decays. In an environment of up to $10^9$ muon decays per second the detector needs to provide precise vertex, time and momentum information to suppress accidental and physics background. The detector consists of cylindrical layers of $50\, μ\text{m}$ thin High Voltage Monolithic Active Pixel Sensors (HV-MAPS) placed in a $1\,\text{T}$ magnetic field. The measurement of the trajectories of the decay particles allows for a precise vertex and momentum reconstruction. Additional layers of fast scintillating fibre and tile detectors provide sub-nanosecond time resolution. The MuPix8 chip is the first large scale prototype, proving the scalability of the HV-MAPS technology. It is produced in the AMS aH18 $180\, \text{nm}$ HV-CMOS process. It consists of three sub-matrices, each providing an untriggered datastream of more than $10\,\text{MHits}/\text{s}$. The latest results from laboratory and testbeam characterisation are presented, showing an excellent performance with efficiencies $>99.6\,\text{\%}$ and a time resolution better than $10\, \text{ns}$ achieved with time walk correction.
△ Less
Submitted 22 May, 2019;
originally announced May 2019.
-
Detector Technologies for CLIC
Authors:
A. C. Abusleme Hoffman,
G. Parès,
T. Fritzsch,
M. Rothermund,
H. Jansen,
K. Krüger,
F. Sefkow,
A. Velyka,
J. Schwandt,
I. Perić,
L. Emberger,
C. Graf,
A. Macchiolo,
F. Simon,
M. Szalay,
N. van der Kolk,
H. Abramowicz,
Y. Benhammou,
O. Borysov,
M. Borysova,
A. Joffe,
S. Kananov,
A. Levy,
I. Levy,
G. Eigen
, et al. (107 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Stan…
▽ More
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Standard Model processes, particularly in the Higgs-boson and top-quark sectors. The precision required for such measurements and the specific conditions imposed by the beam dimensions and time structure put strict requirements on the detector design and technology. This includes low-mass vertexing and tracking systems with small cells, highly granular imaging calorimeters, as well as a precise hit-time resolution and power-pulsed operation for all subsystems. A conceptual design for the CLIC detector system was published in 2012. Since then, ambitious R&D programmes for silicon vertex and tracking detectors, as well as for calorimeters have been pursued within the CLICdp, CALICE and FCAL collaborations, addressing the challenging detector requirements with innovative technologies. This report introduces the experimental environment and detector requirements at CLIC and reviews the current status and future plans for detector technology R&D.
△ Less
Submitted 7 May, 2019;
originally announced May 2019.
-
Characterization of SiPM Avalanche Triggering Probabilities
Authors:
G. Gallina,
F. Retiere,
P. Giampa,
J. Kroeger,
P. Margetak,
S. Byrne Mamahit,
A. De St. Croix,
F. Edaltafar,
N. Massacret,
M. Ward,
G. Zhang
Abstract:
Silicon Photo-Multipliers (SiPMs) are detectors sensitive to single photons that are used to detect scintillation and Cherenkov light in a variety of physics and medical-imaging applications. SiPMs measure single photons by amplifying the photo-generated carriers (electrons or holes) via a Geiger-mode avalanche. The Photon Detection Efficiency (PDE) is the combined probability that a photon is abs…
▽ More
Silicon Photo-Multipliers (SiPMs) are detectors sensitive to single photons that are used to detect scintillation and Cherenkov light in a variety of physics and medical-imaging applications. SiPMs measure single photons by amplifying the photo-generated carriers (electrons or holes) via a Geiger-mode avalanche. The Photon Detection Efficiency (PDE) is the combined probability that a photon is absorbed in the active volume of the device with a subsequently triggered avalanche. Absorption and avalanche triggering probabilities are correlated since the latter probability depends on where the photon is absorbed. In this paper, we introduce a physics motivated parameterization of the avalanche triggering probability that describes the PDE of a SiPM as a function of its reverse bias voltage, at different wavelengths. This parameterization is based on the fact that in p-on-n SiPMs the induced avalanches are electron-driven in the ultra-violet and near-ultra-violet ranges, while they become increasingly hole-driven towards the near-infra-red range. The model has been successfully applied to characterize two Hamamatsu MPPCs and one FBK SiPM, and it can be extended to other SiPMs. Furthermore, this model provides key insight on the electric field structure within SiPMs, which can explain the limitation of existing devices and be used to optimize the performance of future SiPMs.
△ Less
Submitted 11 April, 2019;
originally announced April 2019.
-
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
Authors:
G. Gallina,
P. Giampa,
F. Retiere,
J. Kroeger,
G. Zhang,
M. Ward,
P. Margetak,
G. Lic,
T. Tsang,
L. Doria,
S. Al Kharusi,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. Blatchford,
J. P. Brodsky,
E. Brown,
T. Brunner,
G. F. Cao,
L. Cao
, et al. (126 additional authors not shown)
Abstract:
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency…
▽ More
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233 \text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163 \text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse in the $1 \upmu\text{s}$ interval following the trigger pulse of $0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is $0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of $189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both values are well below the $24\text{ }\%$ saturation PDE advertised by Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
△ Less
Submitted 7 June, 2019; v1 submitted 8 March, 2019;
originally announced March 2019.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Irradiation study of a fully monolithic HV-CMOS pixel sensor design in AMS 180 nm
Authors:
H. Augustin,
N. Berger,
S. Dittmeier,
J. Hammerich,
A. Herkert,
L. Huth,
D. Immig,
J. Kröger,
F. Meier,
I. Perić,
A. -K. Perrevoort,
A. Schöning,
D. vom Bruch,
D. Wiedner
Abstract:
High-Voltage Monolithic Active Pixel Sensors (HV-MAPS) based on the 180 nm HV-CMOS process have been proposed to realize thin, fast and highly integrated pixel sensors. The MuPix7 prototype, fabricated in the commercial AMS H18 process, features a fully integrated on-chip readout, i.e. hit-digitization, zero suppression and data serialization. It is the first fully monolithic HV-CMOS pixel sensor…
▽ More
High-Voltage Monolithic Active Pixel Sensors (HV-MAPS) based on the 180 nm HV-CMOS process have been proposed to realize thin, fast and highly integrated pixel sensors. The MuPix7 prototype, fabricated in the commercial AMS H18 process, features a fully integrated on-chip readout, i.e. hit-digitization, zero suppression and data serialization. It is the first fully monolithic HV-CMOS pixel sensor that has been tested for the use in high irradiation environments like HL-LHC. We present results from laboratory and test beam measurements of MuPix7 prototypes irradiated with neutrons (up to $5.0\cdot10^{15}{\,\rm{n}_{\rm{eq}}/cm^2}$) and protons (up to $7.8\cdot 10^{15} \,\rm{protons}/cm^2$) and compare the performance with non-irradiated sensors. Efficiencies well above 90 % at noise rates below 200 Hz per pixel are measured. A time resolution better than 22 ns is measured for all tested settings and sensors, even at the highest irradiation fluences. The data transmission at 1.25 Gbit/s and the on-chip PLL remain fully functional.
△ Less
Submitted 5 June, 2018; v1 submitted 11 December, 2017;
originally announced December 2017.
-
Beyond conventional photon-number detection with click detectors
Authors:
Johannes Kröger,
Thomas Ahrens,
Jan Sperling,
Werner Vogel,
Heinrich Stolz,
Boris Hage
Abstract:
Photon-number measurements are a fundamental technique for the discrimination and characterization of quantum states of light. Beyond the abilities of state-of-the-art devices, we present measurements with an array of 100 avalanche photodiodes exposed to photon-numbers ranging from well below to significantly above one photon per diode. Despite each single diode only discriminating between zero an…
▽ More
Photon-number measurements are a fundamental technique for the discrimination and characterization of quantum states of light. Beyond the abilities of state-of-the-art devices, we present measurements with an array of 100 avalanche photodiodes exposed to photon-numbers ranging from well below to significantly above one photon per diode. Despite each single diode only discriminating between zero and non-zero photon-numbers we are able to extract characteristic information about the quantum state. We demonstrate a vast enhancement of the applicable intensity range by two orders of magnitude relative to the standard application of such devices. It turns out that the probabilistic mapping of arbitrary photon-numbers on a finite number of registered clicks is not per se a disadvantage compared with true photon counters. Such detector arrays can bridge the gap between single-photon and linear detection, by directly using the recorded data, without the need of elaborate data reconstruction methods.
△ Less
Submitted 3 June, 2017;
originally announced June 2017.