Skip to main content

Showing 1–6 of 6 results for author: Krechetov, Y F

Searching in archive physics. Search in all archives.
.
  1. arXiv:2202.08970  [pdf, other

    physics.ins-det hep-ex nucl-ex nucl-th

    Status and initial physics performance studies of the MPD experiment at NICA

    Authors: MPD Collaboration, V. Abgaryan, R. Acevedo Kado, S. V. Afanasyev, G. N. Agakishiev, E. Alpatov, G. Altsybeev, M. Alvarado Hernández, S. V. Andreeva, T. V. Andreeva, E. V. Andronov, N. V. Anfimov, A. A. Aparin, V. I. Astakhov, E. Atkin, T. Aushev, G. S. Averichev, A. V. Averyanov, A. Ayala, V. A. Babkin, T. Babutsidze, I. A. Balashov, A. Bancer, M. Yu. Barabanov, D. A. Baranov , et al. (454 additional authors not shown)

    Abstract: The Nuclotron-base Ion Collider fAcility (NICA) is under construction at the Joint Institute for Nuclear Research (JINR), with commissioning of the facility expected in late 2022. The Multi-Purpose Detector (MPD) has been designed to operate at NICA and its components are currently in production. The detector is expected to be ready for data taking with the first beams from NICA. This document pro… ▽ More

    Submitted 16 February, 2022; originally announced February 2022.

    Comments: 53 pages, 68 figures, submitted as a Review article to EPJA

    Journal ref: Eur. Phys. J. A 58, 140 (2022)

  2. arXiv:2005.08851  [pdf

    physics.ins-det hep-ex

    Monitoring of the Photon Beam

    Authors: V. I. Alekseev, V. A. Baskov, V. A. Dronov, A. I. Lvov, A. V. Koltsov, Yu. F. Krechetov, V. V. Polyansky, S. S. Sidorin

    Abstract: Presented are the characteristics of systems for monitoring the intensity of the bremsstrahlung photon beam of the PAKHRA accelerator based on Cherenkov counters.

    Submitted 18 May, 2020; originally announced May 2020.

    Comments: 12 pages, 8 figures, 7 references, scientific article

  3. arXiv:2004.07695  [pdf

    physics.ins-det astro-ph.IM

    Calibration of a Shower Lead-Scintillation Spectrometer by Cosmic Radiation

    Authors: V. I. Alekseev, V. A. Baskov, V. A. Dronov, A. I. Lvov, A. V. Koltsov, Yu. F. Krechetov, V. V. Polyansky, S. S. Sidorin

    Abstract: The results of calibration by cosmic muons of a shower lead-scintillation spectrometer of the sandwich type designed to work in high-intensity photon and electron beams with an energy of 0.1 - 1.0 GeV are presented. It was found that the relative energy resolution of the spectrometer depends on the angle of entry of cosmic muons into the spectrometer in the vertical plane and does not depend on th… ▽ More

    Submitted 16 April, 2020; originally announced April 2020.

    Comments: 8 pages, 5 figures, 5 references

  4. arXiv:2004.00937  [pdf

    physics.ins-det hep-ex

    Determination of the Energy Characteristics of an Electron Beam using a Light Scintillator

    Authors: V. I. Alekseev, V. A. Baskov, V. A. Dronov, A. I. L'vov, A. V. Koltsov, Yu. F. Krechetov, V. V. Polyansky

    Abstract: The possibility of using the effect of full energy absorption in a light scintillator when an electron beam passes through it to determine the energy characteristics of a low and medium energy beam (the absorbed energy method) is experimentally presented. The energy calibration of the quasi-monochromatic electron beam of the Pakhra accelerator of the P. N. Lebedev Physical Institute of the Russian… ▽ More

    Submitted 2 April, 2020; originally announced April 2020.

    Comments: 11 pages, 10 figures, 5 references , scientific article

  5. arXiv:1912.08095  [pdf

    physics.ins-det hep-ex

    Characteristics of the secondary electrons calibration beam of the accelerator S-25R "Pakhra"

    Authors: V. I. Alekseev, V. A. Baskov, V. A. Dronov, A. I. Lvov, A. V. Koltsov, Yu. F. Krechetov, V. V. Polyansky, S. S. Sidorin

    Abstract: The characteristics of the secondary electrons` calibration quasi-monochromatic beam of the accelerator S-25R "Pakhra" of the Lebedev Physical Institute of the Russian Academy of Sciences (LPI) on the basis of magnet SP-57 are presented. With an electron energy in the range of 45-280 MeV, a collimator diameter in front of the trigger counters of 3 mm and copper Converter thicknesses of 1-3 mm, the… ▽ More

    Submitted 16 December, 2019; originally announced December 2019.

  6. arXiv:1911.12608  [pdf

    physics.ins-det

    Detection of low energy electrons by a total absorption Cherenkov spectrometer

    Authors: V. I. Alekseev, V. A. Baskov, V. A. Dronov, A. I. L'vov, A. V. Koltsov, Yu. F. Krechetov, E. I. Malinovsky, V. V. Polyansky

    Abstract: Presented are results of calibration, with a quasi-monochromatic electron beam, of a total absorption Cherenkov spectrometer based on the 14.8 X0 lead glass TF-1. It was found that the energy resolution of the spectrometer was 89% to 10% in the energy range of the electron beam E = 6 to 285 MeV, respectively.

    Submitted 28 November, 2019; originally announced November 2019.

    Comments: 6 pages, 5 figures