Future Circular Collider Feasibility Study Report: Volume 2, Accelerators, Technical Infrastructure and Safety
Authors:
M. Benedikt,
F. Zimmermann,
B. Auchmann,
W. Bartmann,
J. P. Burnet,
C. Carli,
A. Chancé,
P. Craievich,
M. Giovannozzi,
C. Grojean,
J. Gutleber,
K. Hanke,
A. Henriques,
P. Janot,
C. Lourenço,
M. Mangano,
T. Otto,
J. Poole,
S. Rajagopalan,
T. Raubenheimer,
E. Todesco,
L. Ulrici,
T. Watson,
G. Wilkinson,
A. Abada
, et al. (1439 additional authors not shown)
Abstract:
In response to the 2020 Update of the European Strategy for Particle Physics, the Future Circular Collider (FCC) Feasibility Study was launched as an international collaboration hosted by CERN. This report describes the FCC integrated programme, which consists of two stages: an electron-positron collider (FCC-ee) in the first phase, serving as a high-luminosity Higgs, top, and electroweak factory;…
▽ More
In response to the 2020 Update of the European Strategy for Particle Physics, the Future Circular Collider (FCC) Feasibility Study was launched as an international collaboration hosted by CERN. This report describes the FCC integrated programme, which consists of two stages: an electron-positron collider (FCC-ee) in the first phase, serving as a high-luminosity Higgs, top, and electroweak factory; followed by a proton-proton collider (FCC-hh) at the energy frontier in the second phase.
FCC-ee is designed to operate at four key centre-of-mass energies: the Z pole, the WW production threshold, the ZH production peak, and the top/anti-top production threshold - delivering the highest possible luminosities to four experiments. Over 15 years of operation, FCC-ee will produce more than 6 trillion Z bosons, 200 million WW pairs, nearly 3 million Higgs bosons, and 2 million top anti-top pairs. Precise energy calibration at the Z pole and WW threshold will be achieved through frequent resonant depolarisation of pilot bunches. The sequence of operation modes remains flexible.
FCC-hh will operate at a centre-of-mass energy of approximately 85 TeV - nearly an order of magnitude higher than the LHC - and is designed to deliver 5 to 10 times the integrated luminosity of the HL-LHC. Its mass reach for direct discovery extends to several tens of TeV. In addition to proton-proton collisions, FCC-hh is capable of supporting ion-ion, ion-proton, and lepton-hadron collision modes.
This second volume of the Feasibility Study Report presents the complete design of the FCC-ee collider, its operation and staging strategy, the full-energy booster and injector complex, required accelerator technologies, safety concepts, and technical infrastructure. It also includes the design of the FCC-hh hadron collider, development of high-field magnets, hadron injector options, and key technical systems for FCC-hh.
△ Less
Submitted 25 April, 2025;
originally announced May 2025.
-
Future Circular Collider Feasibility Study Report: Volume 3, Civil Engineering, Implementation and Sustainability
Authors:
M. Benedikt,
F. Zimmermann,
B. Auchmann,
W. Bartmann,
J. P. Burnet,
C. Carli,
A. Chancé,
P. Craievich,
M. Giovannozzi,
C. Grojean,
J. Gutleber,
K. Hanke,
A. Henriques,
P. Janot,
C. Lourenço,
M. Mangano,
T. Otto,
J. Poole,
S. Rajagopalan,
T. Raubenheimer,
E. Todesco,
L. Ulrici,
T. Watson,
G. Wilkinson,
P. Azzi
, et al. (1439 additional authors not shown)
Abstract:
Volume 3 of the FCC Feasibility Report presents studies related to civil engineering, the development of a project implementation scenario, and environmental and sustainability aspects. The report details the iterative improvements made to the civil engineering concepts since 2018, taking into account subsurface conditions, accelerator and experiment requirements, and territorial considerations. I…
▽ More
Volume 3 of the FCC Feasibility Report presents studies related to civil engineering, the development of a project implementation scenario, and environmental and sustainability aspects. The report details the iterative improvements made to the civil engineering concepts since 2018, taking into account subsurface conditions, accelerator and experiment requirements, and territorial considerations. It outlines a technically feasible and economically viable civil engineering configuration that serves as the baseline for detailed subsurface investigations, construction design, cost estimation, and project implementation planning. Additionally, the report highlights ongoing subsurface investigations in key areas to support the development of an improved 3D subsurface model of the region.
The report describes development of the project scenario based on the 'avoid-reduce-compensate' iterative optimisation approach. The reference scenario balances optimal physics performance with territorial compatibility, implementation risks, and costs. Environmental field investigations covering almost 600 hectares of terrain - including numerous urban, economic, social, and technical aspects - confirmed the project's technical feasibility and contributed to the preparation of essential input documents for the formal project authorisation phase. The summary also highlights the initiation of public dialogue as part of the authorisation process. The results of a comprehensive socio-economic impact assessment, which included significant environmental effects, are presented. Even under the most conservative and stringent conditions, a positive benefit-cost ratio for the FCC-ee is obtained. Finally, the report provides a concise summary of the studies conducted to document the current state of the environment.
△ Less
Submitted 25 April, 2025;
originally announced May 2025.
-
Future Circular Collider Feasibility Study Report: Volume 1, Physics, Experiments, Detectors
Authors:
M. Benedikt,
F. Zimmermann,
B. Auchmann,
W. Bartmann,
J. P. Burnet,
C. Carli,
A. Chancé,
P. Craievich,
M. Giovannozzi,
C. Grojean,
J. Gutleber,
K. Hanke,
A. Henriques,
P. Janot,
C. Lourenço,
M. Mangano,
T. Otto,
J. Poole,
S. Rajagopalan,
T. Raubenheimer,
E. Todesco,
L. Ulrici,
T. Watson,
G. Wilkinson,
P. Azzi
, et al. (1439 additional authors not shown)
Abstract:
Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model.…
▽ More
Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model. The report reviews the experimental opportunities offered by the staged implementation of FCC, beginning with an electron-positron collider (FCC-ee), operating at several centre-of-mass energies, followed by a hadron collider (FCC-hh). Benchmark examples are given of the expected physics performance, in terms of precision and sensitivity to new phenomena, of each collider stage. Detector requirements and conceptual designs for FCC-ee experiments are discussed, as are the specific demands that the physics programme imposes on the accelerator in the domains of the calibration of the collision energy, and the interface region between the accelerator and the detector. The report also highlights advances in detector, software and computing technologies, as well as the theoretical tools /reconstruction techniques that will enable the precision measurements and discovery potential of the FCC experimental programme. This volume reflects the outcome of a global collaborative effort involving hundreds of scientists and institutions, aided by a dedicated community-building coordination, and provides a targeted assessment of the scientific opportunities and experimental foundations of the FCC programme.
△ Less
Submitted 25 April, 2025;
originally announced May 2025.
-
TCAD Simulation of Stitching for Passive CMOS Strip Detectors
Authors:
Marta Baselga,
Jan Hendrik Arling,
Naomi Davis,
Jochen Dingfelder,
Ingrid-Maria Gregor,
Marc Hauser,
Fabian Huegging,
Karl Jakobs,
Michael Karagounis,
Roland Koppenhoefer,
Kevin Kroeninger,
Fabian Lex,
Ulrich Parzefall,
Birkan Sari,
Simon Spannagel,
Dennis Sperlich,
Jens Weingarten,
Iveta Zatocilova
Abstract:
Most of the tracking detectors for high energy particle experiments are filled with silicon detectors since they are radiation hard, they can give very small spatial resolution and they can take advantage of the silicon electronics foundries developments and production lines.
Strip detectors are very useful to cover large areas for tracking purposes, while consuming less power per area compared…
▽ More
Most of the tracking detectors for high energy particle experiments are filled with silicon detectors since they are radiation hard, they can give very small spatial resolution and they can take advantage of the silicon electronics foundries developments and production lines.
Strip detectors are very useful to cover large areas for tracking purposes, while consuming less power per area compared to pixel sensors. The majority of particle physics experiments use conventional silicon strip detectors fabricated in foundries that do not use stitching, relying on a very small number of foundries worldwide that can provide large amounts of strip detectors. Fabricating strip detectors in a CMOS foundry opens the possibility to use more foundries and to include active elements in the strips for future productions. For the passive CMOS strip detectors project we fabricated strip detectors in a CMOS foundry using two 1 cm2 reticles that are stitched together along the wafer. The fabricated strips stitched the reticles three and five times, and it was shown that the performance of those strips is not affected by the stitching.
This paper shows 3D TCAD simulations of the stitching area to investigate the possible effects stitching can have on the performance of the strip detectors, considering different stitching mismatches. We will show that the mismatch of stitched structures up to 1 um does not impact the performance with TCAD simulations which agrees with the results obtained from the measurements.
△ Less
Submitted 19 November, 2024; v1 submitted 26 September, 2024;
originally announced September 2024.
-
Tumor likelihood estimation on MRI prostate data by utilizing k-Space information
Authors:
M. Rempe,
F. Hörst,
C. Seibold,
B. Hadaschik,
M. Schlimbach,
J. Egger,
K. Kröninger,
F. Breuer,
M. Blaimer,
J. Kleesiek
Abstract:
We present a novel preprocessing and prediction pipeline for the classification of magnetic resonance imaging (MRI) that takes advantage of the information rich complex valued k-Space. Using a publicly available MRI raw dataset with 312 subject and a total of 9508 slices, we show the advantage of utilizing the k-Space for better prostate cancer likelihood estimation in comparison to just using the…
▽ More
We present a novel preprocessing and prediction pipeline for the classification of magnetic resonance imaging (MRI) that takes advantage of the information rich complex valued k-Space. Using a publicly available MRI raw dataset with 312 subject and a total of 9508 slices, we show the advantage of utilizing the k-Space for better prostate cancer likelihood estimation in comparison to just using the magnitudinal information in the image domain, with an AUROC of $86.1\%\pm1.8\%$. Additionally, by using high undersampling rates and a simple principal component analysis (PCA) for coil compression, we reduce the time needed for reconstruction by avoiding the time intensive GRAPPA reconstruction algorithm. By using digital undersampling for our experiments, we show that scanning and reconstruction time could be reduced. Even with an undersampling factor of 16, our approach achieves meaningful results, with an AUROC of $71.4\%\pm2.9\%$, using the PCA coil combination and taking into account the k-Space information. With this study, we were able to show the feasibility of preserving phase and k-Space information, with consistent results. Besides preserving valuable information for further diagnostics, this approach can work without the time intensive ADC and reconstruction calculations, greatly reducing the post processing, as well as potential scanning time, increasing patient comfort and allowing a close to real-time prediction.
△ Less
Submitted 14 April, 2025; v1 submitted 4 June, 2024;
originally announced July 2024.
-
Characterisation and simulation of stitched CMOS strip sensors
Authors:
Naomi Davis,
Jan-Hendrik Arling,
Marta Baselga,
Leena Diehl,
Jochen Dingfelder,
Ingrid-Maria Gregor,
Marc Hauser,
Fabian Hügging,
Tomasz Hemperek,
Karl Jakobs,
Michael Karagounis,
Roland Koppenhöfer,
Kevin Kröninger,
Fabian Lex,
Ulrich Parzefall,
Arturo Rodriguez,
Birkan Sari,
Niels Sorgenfrei,
Simon Spannagel,
Dennis Sperlich,
Tianyang Wang,
Jens Weingarten,
Iveta Zatocilova
Abstract:
In high-energy physics, there is a need to investigate alternative silicon sensor concepts that offer cost-efficient, large-area coverage. Sensors based on CMOS imaging technology present such a silicon sensor concept for tracking detectors. The CMOS Strips project investigates passive CMOS strip sensors fabricated by LFoundry in a 150nm technology. By employing the technique of stitching, two dif…
▽ More
In high-energy physics, there is a need to investigate alternative silicon sensor concepts that offer cost-efficient, large-area coverage. Sensors based on CMOS imaging technology present such a silicon sensor concept for tracking detectors. The CMOS Strips project investigates passive CMOS strip sensors fabricated by LFoundry in a 150nm technology. By employing the technique of stitching, two different strip sensor formats have been realised. The sensor performance is characterised based on measurements at the DESY II Test Beam Facility. The sensor response was simulated utilising Monte Carlo methods and electric fields provided by TCAD device simulations. This study shows that employing the stitching technique does not affect the hit detection efficiency. A first look at the electric field within the sensor and its impact on generated charge carriers is being discussed.
△ Less
Submitted 14 May, 2024;
originally announced May 2024.
-
Characterization, Simulation and Test Beam Data Analysis of Stitched Passive CMOS Strip Sensors
Authors:
I. Zatocilova,
J. -H. Arling,
M. Baselga,
N. Davis,
L. Diehl,
J. Dingfelder,
I. -M. Gregor,
M. Hauser,
T. Hemperek,
F. Hügging,
K. Jakobs,
M. Karagounis,
K. Kröninger,
F. Lex,
U. Parzefall,
A. Rodriguez,
B. Sari,
N. Sorgenfrei,
S. Spannagel,
D. Sperlich,
T. Wang,
J. Weingarten
Abstract:
In the passive CMOS Strips Project, strip sensors were designed at the University of Bonn and produced by LFoundry in 150 nm technology, with an additional backside processing from IZM Berlin. Up to five individual reticules were connected by stitching at the foundry in order to obtain the typical strip lengths required for the LHC Phase-II upgrade of ATLAS or CMS trackers. After dicing, sensors w…
▽ More
In the passive CMOS Strips Project, strip sensors were designed at the University of Bonn and produced by LFoundry in 150 nm technology, with an additional backside processing from IZM Berlin. Up to five individual reticules were connected by stitching at the foundry in order to obtain the typical strip lengths required for the LHC Phase-II upgrade of ATLAS or CMS trackers. After dicing, sensors were tested in a probe station and characterised with a Sr90-source as well as laser-based edge- and top-TCT systems. Sensors were also simulated using Sentaurus TCAD. At last, detector modules were constructed from several sensors and thoroughly studied in two beam campaigns at DESY. All of these measurements were performed before and after irradiation. This contribution provides an overview of simulation results, summarises the laboratory measurements and in particular presents first test beam results for irradiated and unirradiated passive CMOS strip sensors. We are demonstrating that large area sensors with sufficient radiation hardness can be obtained by stitching during the CMOS process, and presenting our plans for the next submission in the framework of this project.
△ Less
Submitted 15 November, 2023; v1 submitted 28 September, 2023;
originally announced September 2023.
-
Accurate and fast deep learning dose prediction for a preclinical microbeam radiation therapy study using low-statistics Monte Carlo simulations
Authors:
Florian Mentzel,
Jason Paino,
Micah Barnes,
Matthew Cameron,
Stéphanie Corde,
Elette Engels,
Kevin Kröninger,
Michael Lerch,
Olaf Nackenhorst,
Anatoly Rosenfeld,
Moeva Tehei,
Ah Chung Tsoi,
Sarah Vogel,
Jens Weingarten,
Markus Hagenbuchner,
Susanna Guatelli
Abstract:
Microbeam radiation therapy (MRT) utilizes coplanar synchrotron radiation beamlets and is a proposed treatment approach for several tumour diagnoses that currently have poor clinical treatment outcomes, such as gliosarcomas. Prescription dose estimations for treating preclinical gliosarcoma models in MRT studies at the Imaging and Medical Beamline at the Australian Synchrotron currently rely on Mo…
▽ More
Microbeam radiation therapy (MRT) utilizes coplanar synchrotron radiation beamlets and is a proposed treatment approach for several tumour diagnoses that currently have poor clinical treatment outcomes, such as gliosarcomas. Prescription dose estimations for treating preclinical gliosarcoma models in MRT studies at the Imaging and Medical Beamline at the Australian Synchrotron currently rely on Monte Carlo (MC) simulations. The steep dose gradients associated with the 50$\,μ$m wide coplanar beamlets present a significant challenge for precise MC simulation of the MRT irradiation treatment field in a short time frame. Much research has been conducted on fast dose estimation methods for clinically available treatments. However, such methods, including GPU Monte Carlo implementations and machine learning (ML) models, are unavailable for novel and emerging cancer radiation treatment options like MRT. In this work, the successful application of a fast and accurate machine learning dose prediction model in a retrospective preclinical MRT rodent study is presented for the first time. The ML model predicts the peak doses in the path of the microbeams and the valley doses between them, delivered to the gliosarcoma in rodent patients. The predictions of the ML model show excellent agreement with low-noise MC simulations, especially within the investigated tumour volume. This agreement is despite the ML model being deliberately trained with MC-calculated samples exhibiting significantly higher statistical uncertainties. The successful use of high-noise training set data samples, which are much faster to generate, encourages and accelerates the transfer of the ML model to different treatment modalities for other future applications in novel radiation cancer therapies.
△ Less
Submitted 6 April, 2023; v1 submitted 11 December, 2022;
originally announced December 2022.
-
A step towards treatment planning for microbeam radiation therapy: fast peak and valley dose predictions with 3D U-Nets
Authors:
Florian Mentzel,
Micah Barnes,
Kevin Kröninger,
Michael Lerch,
Olaf Nackenhorst,
Jason Paino,
Anatoly Rosenfeld,
Ayu Saraswati,
Ah Chung Tsoi,
Jens Weingarten,
Markus Hagenbuchner,
Susanna Guatelli
Abstract:
Fast and accurate dose predictions are one of the bottlenecks in treatment planning for microbeam radiation therapy (MRT). In this paper, we propose a machine learning (ML) model based on a 3D U-Net. Our approach predicts separately the large doses of the narrow high intensity synchrotron microbeams and the lower valley doses between them. For this purpose, a concept of macro peak doses and macro…
▽ More
Fast and accurate dose predictions are one of the bottlenecks in treatment planning for microbeam radiation therapy (MRT). In this paper, we propose a machine learning (ML) model based on a 3D U-Net. Our approach predicts separately the large doses of the narrow high intensity synchrotron microbeams and the lower valley doses between them. For this purpose, a concept of macro peak doses and macro valley doses is introduced, describing the respective doses not on a microscopic level but as macroscopic quantities in larger voxels. The ML model is trained to mimic full Monte Carlo (MC) data. Complex physical effects such as polarization are therefore automatically taking into account by the model.
The macro dose distribution approach described in this study allows for superimposing single microbeam predictions to a beam array field making it an interesting candidate for treatment planning. It is shown that the proposed approach can overcome a main obstacle with microbeam dose predictions by predicting a full microbeam irradiation field in less than a minute while maintaining reasonable accuracy.
△ Less
Submitted 21 November, 2022;
originally announced November 2022.
-
Characterization of pixelated silicon detectors for daily quality assurance measurements in proton therapy
Authors:
Isabelle Schilling,
Claus Maximillian Bäcker,
Christian Bäumer,
Carina Behrends,
Kevin Kröninger,
Beate Timmermann,
Jens Weingarten
Abstract:
The advanced imaging and delivery techniques in proton therapy allow conformal high-dose irradiation of the target volume with high accuracy using pencil beam scanning or beam shaping apertures. These irradiation methods increasingly include small radiation fields with large dose gradients, which require detector systems with high spatial resolution for quality assurance. In addition the measureme…
▽ More
The advanced imaging and delivery techniques in proton therapy allow conformal high-dose irradiation of the target volume with high accuracy using pencil beam scanning or beam shaping apertures. These irradiation methods increasingly include small radiation fields with large dose gradients, which require detector systems with high spatial resolution for quality assurance. In addition the measurement of all success parameters for daily quality assurance with only one proton field and one simple detector system would save a lot of time in clinical usage. Based on their good spatial resolution and high rate compatibility, pixelated silicon detectors could meet the new requirements. To assess their applicability in proton therapy, ATLAS pixelated silicon detectors are used to measure the lateral beam profile with high spatial resolution. Furthermore, a dose dependent detector calibration is presented to allow the measurement of the requested output constancy. A strategy to verify the proton energy during the daily quality assurance is under study. Promising results from proof-of-principle measurements at the West German Proton Therapy Centre in Essen, Germany, have been obtained.
△ Less
Submitted 5 April, 2022;
originally announced April 2022.
-
Fast and accurate dose predictions for novel radiotherapy treatments in heterogeneous phantoms using conditional 3D-UNet generative adversarial networks
Authors:
Florian Mentzel,
Kevin Kröninger,
Michael Lerch,
Olaf Nackenhorst,
Jason Paino,
Anatoly Rosenfeld,
Ayu Saraswati,
Ah Chung Tsoi,
Jens Weingarten,
Markus Hagenbuchner,
Susanna Guatelli
Abstract:
Novel radiotherapy techniques like synchrotron X-ray microbeam radiation therapy (MRT), require fast dose distribution predictions that are accurate at the sub-mm level, especially close to tissue/bone/air interfaces. Monte Carlo physics simulations are recognised to be one of the most accurate tools to predict the dose delivered in a target tissue but can be very time consuming and therefore proh…
▽ More
Novel radiotherapy techniques like synchrotron X-ray microbeam radiation therapy (MRT), require fast dose distribution predictions that are accurate at the sub-mm level, especially close to tissue/bone/air interfaces. Monte Carlo physics simulations are recognised to be one of the most accurate tools to predict the dose delivered in a target tissue but can be very time consuming and therefore prohibitive for treatment planning. Faster dose prediction algorithms are usually developed for clinically deployed treatments only. In this work, we explore a new approach for fast and accurate dose estimations suitable for novel treatments using digital phantoms used in pre-clinical development and modern machine learning techniques. We develop a generative adversarial network (GAN) model, which is able to emulate the equivalent Geant4 Monte Carlo simulation with adequate accuracy, and use it to predict the radiation dose delivered by a broad synchrotron beam to various phantoms. The energy depositions used for the training of the GAN are obtained using full Geant4 Monte Carlo simulations of a synchrotron radiation broad beam passing through the phantoms. The energy deposition is scored and predicted in voxel matrices of size 140x18x18 with a voxel edge length of 1 mm. The GAN model consists of two competing 3D convolutional neural networks, which are conditioned on the photon beam and phantom properties. The energy deposition predictions inside all phantom geometries under investigation show deviations of less than 3% of the maximum deposited energy from the simulation for roughly 99% of the voxels in the field of the beam. The computing time for a single prediction is reduced from several hundred hours using Geant4 simulation to less than a second using the GAN model.
△ Less
Submitted 16 February, 2022; v1 submitted 14 February, 2022;
originally announced February 2022.
-
Reformulation of a likelihood approach to fake-lepton estimation in the framework of Bayesian inference
Authors:
Johannes Erdmann,
Cornelius Grunwald,
Kevin Kröninger,
Salvatore La Cagnina,
Lars Röhrig,
Erich Varnes
Abstract:
Prompt isolated leptons are essential in many analyses in high-energy particle physics but are subject to fake-lepton background, i.e. objects that mimic the lepton signature. The fake-lepton background is difficult to estimate from simulation and is often directly determined from data. A popular method is the matrix method, which however suffers from several limitations. This paper recapitulates…
▽ More
Prompt isolated leptons are essential in many analyses in high-energy particle physics but are subject to fake-lepton background, i.e. objects that mimic the lepton signature. The fake-lepton background is difficult to estimate from simulation and is often directly determined from data. A popular method is the matrix method, which however suffers from several limitations. This paper recapitulates an alternative approach based on a likelihood with Poisson constraints and reformulates the problem from a different starting point in the framework of Bayesian statistics. The equality of both approaches is shown and several cases are studied in which the matrix method is limited. In addition, the fake lepton background is recalculated and compared to the estimate with the matrix method in an example top-quark measurement.
△ Less
Submitted 24 November, 2021; v1 submitted 25 June, 2021;
originally announced June 2021.
-
No more glowing in the dark: How deep learning improves exposure date estimation in thermoluminescence dosimetry
Authors:
Florian Mentzel,
Evelin Derugin,
Hannah Jansen,
Kevin Kröninger,
Olaf Nackenhorst,
Jörg Walbersloh,
Jens Weingarten
Abstract:
The time- or temperature-resolved detector signal from a thermoluminescence dosimeter can reveal additional information about circumstances of an exposure to ionizing irradiation. We present studies using deep neural networks to estimate the date of a single irradiation with 12 mSv within a monitoring interval of 42 days from glow curves of novel TL-DOS personal dosimeters developed by the Materia…
▽ More
The time- or temperature-resolved detector signal from a thermoluminescence dosimeter can reveal additional information about circumstances of an exposure to ionizing irradiation. We present studies using deep neural networks to estimate the date of a single irradiation with 12 mSv within a monitoring interval of 42 days from glow curves of novel TL-DOS personal dosimeters developed by the Materialprüfungsamt NRW in cooperation with TU Dortmund University. Using a deep convolutional network, the irradiation date can be predicted from raw time-resolved glow curve data with an uncertainty of roughly 1-2 days on a 68% confidence level without the need for a prior transformation into temperature space and a subsequent glow curve deconvolution. This corresponds to a significant improvement in prediction accuracy compared to a prior publication, which yielded a prediction uncertainty of 2-4 days using features obtained from a glow curve deconvolution as input to a neural network.
△ Less
Submitted 2 September, 2021; v1 submitted 14 June, 2021;
originally announced June 2021.
-
BAT.jl -- A Julia-based tool for Bayesian inference
Authors:
Oliver Schulz,
Frederik Beaujean,
Allen Caldwell,
Cornelius Grunwald,
Vasyl Hafych,
Kevin Kröninger,
Salvatore La Cagnina,
Lars Röhrig,
Lolian Shtembari
Abstract:
We describe the development of a multi-purpose software for Bayesian statistical inference, BAT.jl, written in the Julia language. The major design considerations and implemented algorithms are summarized here, together with a test suite that ensures the proper functioning of the algorithms. We also give an extended example from the realm of physics that demonstrates the functionalities of BAT.jl.
We describe the development of a multi-purpose software for Bayesian statistical inference, BAT.jl, written in the Julia language. The major design considerations and implemented algorithms are summarized here, together with a test suite that ensures the proper functioning of the algorithms. We also give an extended example from the realm of physics that demonstrates the functionalities of BAT.jl.
△ Less
Submitted 7 August, 2020;
originally announced August 2020.
-
First Annealing Studies of Irradiated Silicon Sensors with Modified ATLAS Pixel Implantations
Authors:
M. Wagner,
A. Gisen,
M. Hötting,
V. Hohm,
C. Krause,
K. Kröninger,
A. Kroner,
J. Lönker,
M. Muschak,
J. Weingarten,
F. Wizemann
Abstract:
Planar silicon pixel sensors with modified n$^+$-implantation shapes based on the IBL pixel sensor were designed in Dortmund. The sensors with a pixel size of $250\,μ$m $\times$ $50\,μ$m are produced in n$^+$-in-n sensor technology.
The charge collection efficiency should improve with electrical field strength maxima created by the different n$^+$-implantation shapes. Therefore, higher particle…
▽ More
Planar silicon pixel sensors with modified n$^+$-implantation shapes based on the IBL pixel sensor were designed in Dortmund. The sensors with a pixel size of $250\,μ$m $\times$ $50\,μ$m are produced in n$^+$-in-n sensor technology.
The charge collection efficiency should improve with electrical field strength maxima created by the different n$^+$-implantation shapes. Therefore, higher particle detection efficiencies at lower bias voltages could be achieved. The modified pixel designs and the IBL standard design are placed on one sensor to test and compare the designs. The sensor can be read out with the FE-I4 readout chip.
At the iWoRiD 2018, measurements of sensors irradiated with protons and neutrons respectively at different facilities were presented and showed incongruent results. Unintended annealing during irradiation was considered as an explanation for the observed differences in the hit detection efficiency for two neutron irradiated sensors. This hypothesis will be examined and confirmed in this work, presenting first annealing studies of sensors irradiated with neutrons in Ljubljana.
△ Less
Submitted 9 October, 2019; v1 submitted 28 August, 2019;
originally announced August 2019.
-
Temperature scaling of reverse current generated in proton irradiated silicon bulk
Authors:
Felix Wizemann,
Andreas Gisen,
Kevin Kröninger,
Jens Weingarten
Abstract:
The value of the scaling parameter $E_{\text{eff}}$ of the temperature dependence for current generated in silicon bulk is investigated for highly irradiated devices.
Measurements of devices irradiated to fluences above $1 \times 10^{15} n_{\text{eq}} \text{cm}^{-2} $ have shown a different temperature scaling behaviour than devices irradiated to lower fluences. This paper presents the determina…
▽ More
The value of the scaling parameter $E_{\text{eff}}$ of the temperature dependence for current generated in silicon bulk is investigated for highly irradiated devices.
Measurements of devices irradiated to fluences above $1 \times 10^{15} n_{\text{eq}} \text{cm}^{-2} $ have shown a different temperature scaling behaviour than devices irradiated to lower fluences. This paper presents the determination of the parameter $E_{\text{eff}}$ for diodes irradiated with protons up to fluences of $3 \times 10^{15} n_{\text{eq}} \text{cm}^{-2}$ in the bias range from $0$V to $1000$V at temperatures from $-36 ^{\circ}\text{C}$ to $0 ^{\circ}\text{C}$ at different stages of annealing. It is shown that $E_{\text{eff}}$ for highly irradiated devices depends on the applied electric field: below depletion voltage, $E_{\text{eff}}$ is observed to have a lower value than above depletion voltage
△ Less
Submitted 6 June, 2019; v1 submitted 9 April, 2019;
originally announced April 2019.
-
Investigation of modified ATLAS pixel implantations after irradiation with neutrons
Authors:
A. Gisen,
S. Altenheiner,
C. Gößling,
M. Grothe,
R. Klingenberg,
K. Kröninger,
J. Lönker,
M. Weers,
T. Wittig,
F. Wizemann
Abstract:
The innermost part of the tracking detector of the ATLAS experiment consists mainly of planar n$^+$-in-n silicon pixel sensors. During the phase-0 upgrade, the Insertable B-Layer (IBL) was installed closest to the beam pipe. Its pixels are arranged with a pitch of $250\,μ$m$\,\times\,50\,μ$m with a rectangular shaped n$^+$ implantation. Based on this design modified pixel designs have been develop…
▽ More
The innermost part of the tracking detector of the ATLAS experiment consists mainly of planar n$^+$-in-n silicon pixel sensors. During the phase-0 upgrade, the Insertable B-Layer (IBL) was installed closest to the beam pipe. Its pixels are arranged with a pitch of $250\,μ$m$\,\times\,50\,μ$m with a rectangular shaped n$^+$ implantation. Based on this design modified pixel designs have been developed in Dortmund.
Six of these new pixel designs are arranged in structures of ten columns and were placed beside structures with the standard design on one sensor. Because of a special guard ring design, each structure can be powered and investigated separately. Several of these sensors were bump bonded to FE-I4 read-out chips. One of these modules was irradiated with reactor neutrons up to a fluence of $5 \times 10^{15} \, n_{\text{eq}}\text{cm}^{-2}$.
This contribution presents important sensor characteristics, charge collection determined with radioactive sources and hit efficiency measurements, performed in laboratory and test beam, of this irradiated device. It is shown that the new modified designs perform similar or better than the IBL standard design in terms of charge collection and tracking efficiency, at the cost of a slightly increased leakage current.
△ Less
Submitted 20 August, 2018; v1 submitted 2 February, 2018;
originally announced February 2018.
-
The Large Enriched Germanium Experiment for Neutrinoless Double Beta Decay (LEGEND)
Authors:
LEGEND Collaboration,
N. Abgrall,
A. Abramov,
N. Abrosimov,
I. Abt,
M. Agostini,
M. Agartioglu,
A. Ajjaq,
S. I. Alvis,
F. T. Avignone III,
X. Bai,
M. Balata,
I. Barabanov,
A. S. Barabash,
P. J. Barton,
L. Baudis,
L. Bezrukov,
T. Bode,
A. Bolozdynya,
D. Borowicz,
A. Boston,
H. Boston,
S. T. P. Boyd,
R. Breier,
V. Brudanin
, et al. (208 additional authors not shown)
Abstract:
The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely…
▽ More
The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely low backgrounds, at the level of $\sim$0.1 count /(FWHM$\cdot$t$\cdot$yr) in the region of the signal. The current generation $^{76}$Ge experiments GERDA and the MAJORANA DEMONSTRATOR utilizing high purity Germanium detectors with an intrinsic energy resolution of 0.12%, have achieved the lowest backgrounds by over an order of magnitude in the 0$νββ$ signal region of all 0$νββ$ experiments. Building on this success, the LEGEND collaboration has been formed to pursue a tonne-scale $^{76}$Ge experiment. The collaboration aims to develop a phased 0$νββ$ experimental program with discovery potential at a half-life approaching or at $10^{28}$ years, using existing resources as appropriate to expedite physics results.
△ Less
Submitted 6 September, 2017;
originally announced September 2017.
-
Planar n-in-n quad module prototypes for the ATLAS ITk upgrade at HL-LHC
Authors:
Andreas Gisen,
Silke Altenheiner,
Ingo Burmeister,
Claus Gößling,
Reiner Klingenberg,
Kevin Kröninger,
Jonas Lönker,
Mareike Weers,
Felix Wizemann
Abstract:
In order to meet the requirements of the High Luminosity LHC (HL-LHC), it will be necessary to replace the current tracker of the ATLAS experiment. Therefore, a new all-silicon tracking detector is being developed, the so-called Inner Tracker (ITk). The use of quad chip modules is intended in its pixel region. These modules consist of a silicon sensor that forms a unit along with four read-out chi…
▽ More
In order to meet the requirements of the High Luminosity LHC (HL-LHC), it will be necessary to replace the current tracker of the ATLAS experiment. Therefore, a new all-silicon tracking detector is being developed, the so-called Inner Tracker (ITk). The use of quad chip modules is intended in its pixel region. These modules consist of a silicon sensor that forms a unit along with four read-out chips. The current ATLAS pixel detector consists of planar n-in-n silicon pixel sensors. Similar sensors and four FE-I4 read-out chips were assembled to first prototypes of planar n-in-n quad modules. The main focus of the investigation of these modules was the region between the read-out chips, especially the central area between all four read-out chips. There are special pixel cells placed on the sensor which cover the gap between the read-out chips. This contribution focuses on the characterization of a non-irradiated device, including important sensor characteristics, charge collection determined with radioactive sources as well as hit efficiency measurements, performed in the laboratory and at testbeams. In addition, first laboratory results of an irradiated device are presented.
△ Less
Submitted 18 December, 2017; v1 submitted 28 August, 2017;
originally announced August 2017.
-
Suppression of alpha-induced lateral surface events in the COBRA experiment using CdZnTe detectors with an instrumented guard-ring electrode
Authors:
J. -H. Arling,
M. Gerhardt,
C. Gößling,
D. Gehre,
R. Klingenberg,
K. Kröninger,
C. Nitsch,
T. Quante,
K. Rohatsch,
J. Tebrügge,
R. Temminghoff,
R. Theinert,
S. Zatschler,
K. Zuber
Abstract:
The COBRA collaboration searches for neutrinoless double beta-decay ($0νββ$-decay) using CdZnTe semiconductor detectors with a coplanar-grid readout and a surrounding guard-ring structure. The operation of the COBRA demonstrator at the Gran Sasso underground laboratory (LNGS) indicates that alpha-induced lateral surface events are the dominant source of background events. By instrumenting the guar…
▽ More
The COBRA collaboration searches for neutrinoless double beta-decay ($0νββ$-decay) using CdZnTe semiconductor detectors with a coplanar-grid readout and a surrounding guard-ring structure. The operation of the COBRA demonstrator at the Gran Sasso underground laboratory (LNGS) indicates that alpha-induced lateral surface events are the dominant source of background events. By instrumenting the guard-ring electrode it is possible to suppress this type of background. In laboratory measurements this method achieved a suppression factor of alpha-induced lateral surface events of $5300^{+2660}_{-1380}$, while retaining $85.3\pm0.1\%$ of gamma events occurring in the entire detector volume. This suppression is superior to the pulse-shape analysis methods used so far in COBRA by three orders of magnitude.
△ Less
Submitted 12 December, 2017; v1 submitted 25 January, 2017;
originally announced January 2017.
-
The Dortmund Low Background Facility - Low-Background Gamma Ray Spectrometry with an Artificial Overburden
Authors:
Holger Gastrich,
Claus Gößling,
Reiner Klingenberg,
Kevin Kröninger,
Till Neddermann,
Christian Nitsch,
Thomas Quante,
Kai Zuber
Abstract:
High-purity germanium (HPGe) detectors used for low-background gamma ray spectrometry are usually operated under either a fairly low overburden of the order of one meter of water equivalent (mw.e.) or a high overburden of the order of 100mw.e. or more, e.g. in specialized underground laboratories. The Dortmund Low Background Facility (DLB) combines the advantages of both approaches. The artificial…
▽ More
High-purity germanium (HPGe) detectors used for low-background gamma ray spectrometry are usually operated under either a fairly low overburden of the order of one meter of water equivalent (mw.e.) or a high overburden of the order of 100mw.e. or more, e.g. in specialized underground laboratories. The Dortmund Low Background Facility (DLB) combines the advantages of both approaches. The artificial overburden of 10mw.e. already shields the hadronic component of cosmic rays. The inner shielding, featuring a state-of-the-art neutron shielding and an active muon veto, enables low-background gamma ray spectrometry at an easy-accessible location at the campus of the Technische Universität Dortmund.
The integral background count rate between 40keV and 2700keV is 2.528+-0.004counts/kg/minute. This enables activity measurements of primordial radionuclides in the range of some 10mBq/kg within a week of measurement time.
△ Less
Submitted 6 December, 2015;
originally announced December 2015.
-
Results of a search for neutrinoless double-beta decay using the COBRA demonstrator
Authors:
Joachim Ebert,
Matthew Fritts,
Daniel Gehre,
Claus Goessling,
Caren Hagner,
Nadine Heidrich,
Reiner Klingenberg,
Kevin Kroeninger,
Christian Nitsch,
Christian Oldorf,
Thomas Quante,
Silke Rajek,
Henning Rebber,
Katja Rohatsch,
Jan Tebruegge,
Robert Temminghoff,
Robert Theinert,
Jan Timm,
Bjoern Wonsak,
Stefan Zatschler,
Kai Zuber
Abstract:
Neutrinoless double-$β$ decay ($0νββ$ decay) is a hypothetical process that can occur if the neutrino is its own antiparticle. The COBRA collaboration operates a demonstrator to search for these decays at the Laboratori Nazionali del Gran Sasso in Italy using CdZnTe semiconductor detectors. The exposure of $234.7\,$kg\,d considered in this analysis was collected between September 2011 and February…
▽ More
Neutrinoless double-$β$ decay ($0νββ$ decay) is a hypothetical process that can occur if the neutrino is its own antiparticle. The COBRA collaboration operates a demonstrator to search for these decays at the Laboratori Nazionali del Gran Sasso in Italy using CdZnTe semiconductor detectors. The exposure of $234.7\,$kg\,d considered in this analysis was collected between September 2011 and February 2015. The analysis focuses on the decay of the nuclides $^{114}$Cd, $^{128}$Te, $^{70}$Zn, $^{130}$Te and $^{116}$Cd. A Bayesian analysis is performed to estimate the signal strength of $0νββ$ decay. No signal is observed for any of these nuclides. Therefore, the following half-life limits at 90% credibility are set: $T_{1/2}^{0ν}>1.6\cdot10^{21}\,$yr ($^{114}$Cd), $T_{1/2}^{0ν}>1.9\cdot10^{21}\,$yr ($^{128}Te$), $T_{1/2}^{0ν}>6.8\cdot10^{18}\,$yr ($^{70}$Zn), $T_{1/2}^{0ν}>6.1\cdot10^{21}\,$yr ($^{130}$Te), and $T_{1/2}^{0ν}>1.1\cdot10^{21}\,$yr ($^{116}$Cd).
△ Less
Submitted 29 November, 2016; v1 submitted 14 September, 2015;
originally announced September 2015.
-
Characterization of a large CdZnTe coplanar quad-grid semiconductor detector
Authors:
J. Ebert,
D. Gehre,
C. Gößling,
C. Hagner,
N. Heidrich,
R. Klingenberg,
K. Kröninger,
C. Nitsch,
C. Oldorf,
T. Quante,
S. Rajek,
H. Rebber,
K. Rohatsch,
J. Tebrügge,
R. Temminghoff,
R. Theinert,
J. Timm,
B. Wonsak,
S. Zatschler,
K. Zuber
Abstract:
The COBRA collaboration aims to search for neutrinoless double beta-decay of $^{116}$Cd. A demonstrator setup with 64 CdZnTe semiconductor detectors, each with a volume of 1cm$^3$, is currently being operated at the LNGS underground laboratory in Italy. This paper reports on the characterization of a large (2 $\times$ 2 $\times$ 1.5)cm$^3$ CdZnTe detector with a new coplanar-grid design for applic…
▽ More
The COBRA collaboration aims to search for neutrinoless double beta-decay of $^{116}$Cd. A demonstrator setup with 64 CdZnTe semiconductor detectors, each with a volume of 1cm$^3$, is currently being operated at the LNGS underground laboratory in Italy. This paper reports on the characterization of a large (2 $\times$ 2 $\times$ 1.5)cm$^3$ CdZnTe detector with a new coplanar-grid design for applications in $γ$-ray spectroscopy and low-background operation. Several studies of electric properties as well as of the spectrometric performance, like energy response and resolution, are conducted. Furthermore, measurements including investigating the operational stability and a possibility to identify multiple-scattered photons are presented.
△ Less
Submitted 11 February, 2016; v1 submitted 8 September, 2015;
originally announced September 2015.
-
Long-Term Stability of Underground Operated CZT Detectors Based on the Analysis of Intrinsic $^{113}$Cd β$^{-}$-Decay
Authors:
J. Ebert,
C. Goessling,
D. Gehre,
C. Hagner,
N. Heidrich,
R. Klingenberg,
K. Kroeninger,
C. Nitsch,
C. Oldorf,
T. Quante,
S. Rajek,
H. Rebber,
K. Rohatsch,
J. Tebruegge,
R. Temminghoff,
R. Theinert,
J. Timm,
B. Wonsak,
S. Zatschler,
K. Zuber
Abstract:
The COBRA collaboration operates a demonstrator setup at the underground facility LNGS (Laboratori Nazionali del Gran Sasso, located in Italy) to prove the technological capabilities of this concept for the search for neutrinoless double beta-decay. The setup consists of 64 $(1\times\!1\times\!1)$ cm$^{3}$ CZT detectors in CPG configuration. One purpose of this demonstrator is to test if reliable…
▽ More
The COBRA collaboration operates a demonstrator setup at the underground facility LNGS (Laboratori Nazionali del Gran Sasso, located in Italy) to prove the technological capabilities of this concept for the search for neutrinoless double beta-decay. The setup consists of 64 $(1\times\!1\times\!1)$ cm$^{3}$ CZT detectors in CPG configuration. One purpose of this demonstrator is to test if reliable long-term operation of CZT-CPG detectors in such a setup is possible. The demonstrator has been operated under ultra low-background conditions since more than three years and collected data corresponding to an exposure of 218 kg$\cdot$days. The presented study focuses on the long-term stability of CZT detectors by analyzing the intrinsic, fourfold forbidden non-unique $^{113}$Cd single beta-decay. It can be shown that CZT detectors can be operated stably for long periods of time and that the $^{113}$Cd single beta-decay can be used as an internal monitor of the detector performance during the runtime of the experiment.
△ Less
Submitted 13 August, 2015;
originally announced August 2015.
-
The COBRA demonstrator at the LNGS underground laboratory
Authors:
The COBRA collaboration,
J. Ebert,
M. Fritts,
D. Gehre,
C. Gößling,
T. Göpfert,
C. Hagner,
N. Heidrich,
R. Klingenberg,
T. Köttig,
K. Kröninger,
T. Michel,
T. Neddermann,
C. Nitsch,
C. Oldorf,
T. Quante,
S. Rajek,
H. Rebber,
O. Reinecke,
K. Rohatsch,
O. Schulz,
A. Sörensen,
I. Stekl,
J. Tebrügge,
R. Temminghoff
, et al. (6 additional authors not shown)
Abstract:
The COBRA demonstrator, a prototype for a large-scale experiment searching for neutrinoless double beta-decay, was built at the underground laboratory Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It consists of an array of 64 monolithic, calorimetric CdZnTe semiconductor detectors with a coplanar-grid design and a total mass of 380g. It is used to investigate the experimental challenges fa…
▽ More
The COBRA demonstrator, a prototype for a large-scale experiment searching for neutrinoless double beta-decay, was built at the underground laboratory Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It consists of an array of 64 monolithic, calorimetric CdZnTe semiconductor detectors with a coplanar-grid design and a total mass of 380g. It is used to investigate the experimental challenges faced when operating CdZnTe detectors in low-background mode, to identify potential background sources and to show the long-term stability of the detectors. The first data-taking period started in 2011 with a subset of the detectors, while the demonstrator was completed in November 2013. To date, more than 250kg d of data have been collected. This paper describes technical details of the experimental setup and the hardware components.
△ Less
Submitted 18 November, 2015; v1 submitted 29 July, 2015;
originally announced July 2015.
-
Objective Bayesian analysis of counting experiments with correlated sources of background
Authors:
Diego Casadei,
Cornelius Grunwald,
Kevin Kröninger,
Florian Mentzel
Abstract:
Searches for faint signals in counting experiments are often encountered in particle physics and astrophysics, as well as in other fields. Many problems can be reduced to the case of a model with independent and Poisson-distributed signal and background. Often several background contributions are present at the same time, possibly correlated. We provide the analytic solution of the statistical inf…
▽ More
Searches for faint signals in counting experiments are often encountered in particle physics and astrophysics, as well as in other fields. Many problems can be reduced to the case of a model with independent and Poisson-distributed signal and background. Often several background contributions are present at the same time, possibly correlated. We provide the analytic solution of the statistical inference problem of estimating the signal in the presence of multiple backgrounds, in the framework of objective Bayes statistics. The model can be written in the form of a product of a single Poisson distribution with a multinomial distribution. The first is related to the total number of events, whereas the latter describes the fraction of events coming from each individual source. Correlations among different backgrounds can be included in the inference problem by a suitable choice of the priors.
△ Less
Submitted 19 January, 2017; v1 submitted 10 April, 2015;
originally announced April 2015.
-
(MC)**3 -- a Multi-Channel Markov Chain Monte Carlo algorithm for phase-space sampling
Authors:
Kevin Kroeninger,
Steffen Schumann,
Benjamin Willenberg
Abstract:
A new Monte Carlo algorithm for phase-space sampling, named (MC)**3, is presented. It is based on Markov Chain Monte Carlo techniques but at the same time incorporates prior knowledge about the target distribution in the form of suitable phase-space mappings from a corresponding Multi-Channel importance sampling Monte Carlo. The combined approach inherits the benefits of both techniques while typi…
▽ More
A new Monte Carlo algorithm for phase-space sampling, named (MC)**3, is presented. It is based on Markov Chain Monte Carlo techniques but at the same time incorporates prior knowledge about the target distribution in the form of suitable phase-space mappings from a corresponding Multi-Channel importance sampling Monte Carlo. The combined approach inherits the benefits of both techniques while typical drawbacks of either solution get ameliorated.
△ Less
Submitted 8 October, 2014; v1 submitted 16 April, 2014;
originally announced April 2014.
-
The GERDA experiment for the search of 0νββ decay in ^{76}Ge
Authors:
GERDA Collaboration,
K. -H. Ackermann,
M. Agostini,
M. Allardt,
M. Altmann,
E. Andreotti,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
M. Barnabe Heider,
N. Barros,
L. Baudis,
C. Bauer,
N. Becerici-Schmidt,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
V. Brudanin,
R. Brugnera,
D. Budjas,
A. Caldwell
, et al. (114 additional authors not shown)
Abstract:
The GERDA collaboration is performing a search for neutrinoless double beta decay of ^{76}Ge with the eponymous detector. The experiment has been installed and commissioned at the Laboratori Nazionali del Gran Sasso and has started operation in November 2011. The design, construction and first operational results are described, along with detailed information from the R&D phase.
The GERDA collaboration is performing a search for neutrinoless double beta decay of ^{76}Ge with the eponymous detector. The experiment has been installed and commissioned at the Laboratori Nazionali del Gran Sasso and has started operation in November 2011. The design, construction and first operational results are described, along with detailed information from the R&D phase.
△ Less
Submitted 17 December, 2012;
originally announced December 2012.
-
The MGDO software library for data analysis in Ge neutrinoless double-beta decay experiments
Authors:
M. Agostini,
J. A. Detwiler,
P. Finnerty,
K. Kröninger,
D. Lenz,
J. Liu,
M. G. Marino,
R. Martin,
K. D. Nguyen,
L. Pandola,
A. G. Schubert,
O. Volynets,
P. Zavarise
Abstract:
The GERDA and Majorana experiments will search for neutrinoless double-beta decay of germanium-76 using isotopically enriched high-purity germanium detectors. Although the experiments differ in conceptual design, they share many aspects in common, and in particular will employ similar data analysis techniques. The collaborations are jointly developing a C++ software library, MGDO, which contains a…
▽ More
The GERDA and Majorana experiments will search for neutrinoless double-beta decay of germanium-76 using isotopically enriched high-purity germanium detectors. Although the experiments differ in conceptual design, they share many aspects in common, and in particular will employ similar data analysis techniques. The collaborations are jointly developing a C++ software library, MGDO, which contains a set of data objects and interfaces to encapsulate, store and manage physical quantities of interest, such as waveforms and high-purity germanium detector geometries. These data objects define a common format for persistent data, whether it is generated by Monte Carlo simulations or an experimental apparatus, to reduce code duplication and to ease the exchange of information between detector systems. MGDO also includes general-purpose analysis tools that can be used for the processing of measured or simulated digital signals. The MGDO design is based on the Object-Oriented programming paradigm and is very flexible, allowing for easy extension and customization of the components. The tools provided by the MGDO libraries are used by both GERDA and Majorana.
△ Less
Submitted 30 November, 2011;
originally announced November 2011.
-
p-Values for Model Evaluation
Authors:
Frederik Beaujean,
Allen Caldwell,
Daniel Kollar,
Kevin Kroeninger
Abstract:
Deciding whether a model provides a good description of data is often based on a goodness-of-fit criterion summarized by a p-value. Although there is considerable confusion concerning the meaning of p-values, leading to their misuse, they are nevertheless of practical importance in common data analysis tasks. We motivate their application using a Bayesian argumentation. We then describe commonly a…
▽ More
Deciding whether a model provides a good description of data is often based on a goodness-of-fit criterion summarized by a p-value. Although there is considerable confusion concerning the meaning of p-values, leading to their misuse, they are nevertheless of practical importance in common data analysis tasks. We motivate their application using a Bayesian argumentation. We then describe commonly and less commonly known discrepancy variables and how they are used to define p-values. The distribution of these are then extracted for examples modeled on typical data analysis tasks, and comments on their usefulness for determining goodness-of-fit are given.
△ Less
Submitted 23 May, 2011; v1 submitted 7 November, 2010;
originally announced November 2010.
-
BAT - The Bayesian Analysis Toolkit
Authors:
Allen Caldwell,
Daniel Kollar,
Kevin Kroeninger
Abstract:
We describe the development of a new toolkit for data analysis. The analysis package is based on Bayes' Theorem, and is realized with the use of Markov Chain Monte Carlo. This gives access to the full posterior probability distribution. Parameter estimation, limit setting and uncertainty propagation are implemented in a straightforward manner. A goodness-of-fit criterion is presented which is in…
▽ More
We describe the development of a new toolkit for data analysis. The analysis package is based on Bayes' Theorem, and is realized with the use of Markov Chain Monte Carlo. This gives access to the full posterior probability distribution. Parameter estimation, limit setting and uncertainty propagation are implemented in a straightforward manner. A goodness-of-fit criterion is presented which is intuitive and of great practical use.
△ Less
Submitted 19 August, 2008;
originally announced August 2008.
-
Signal discovery in sparse spectra: a Bayesian analysis
Authors:
Allen Caldwell,
Kevin Kröninger
Abstract:
A Bayesian analysis of the probability of a signal in the presence of background is developed, and criteria are proposed for claiming evidence for, or the discovery of a signal. The method is general and in particular applicable to sparsely populated spectra. Monte Carlo techniques to evaluate the sensitivity of an experiment are described. As an example, the method is used to calculate the sens…
▽ More
A Bayesian analysis of the probability of a signal in the presence of background is developed, and criteria are proposed for claiming evidence for, or the discovery of a signal. The method is general and in particular applicable to sparsely populated spectra. Monte Carlo techniques to evaluate the sensitivity of an experiment are described. As an example, the method is used to calculate the sensitivity of the GERDA experiment to neutrinoless double beta decay.
△ Less
Submitted 25 August, 2006;
originally announced August 2006.