-
BICEP/Keck XIX: Extremely Thin Composite Polymer Vacuum Windows for BICEP and Other High Throughput Millimeter Wave Telescopes
Authors:
BICEP/Keck Collaboration,
:,
P. A. R. Ade,
Z. Ahmed,
M. Amiri,
D. Barkats,
R. Basu Thakur,
C. A. Bischoff,
D. Beck,
J. J. Bock,
H. Boenish,
V. Buza,
K. Carter,
J. R. Cheshire IV,
J. Connors,
J. Cornelison,
L. Corrigan,
M. Crumrine,
S. Crystian,
A. J. Cukierman,
E. Denison,
L. Duband,
M. Echter,
M. Eiben,
B. D. Elwood
, et al. (69 additional authors not shown)
Abstract:
Millimeter-wave refracting telescopes targeting the degree-scale structure of the cosmic microwave background (CMB) have recently grown to diffraction-limited apertures of over 0.5 meters. These instruments are entirely housed in vacuum cryostats to support their sub-kelvin bolometric detectors and to minimize radiative loading from thermal emission due to absorption loss in their transmissive opt…
▽ More
Millimeter-wave refracting telescopes targeting the degree-scale structure of the cosmic microwave background (CMB) have recently grown to diffraction-limited apertures of over 0.5 meters. These instruments are entirely housed in vacuum cryostats to support their sub-kelvin bolometric detectors and to minimize radiative loading from thermal emission due to absorption loss in their transmissive optical elements. The large vacuum window is the only optical element in the system at ambient temperature, and therefore minimizing loss in the window is crucial for maximizing detector sensitivity. This motivates the use of low-loss polymer materials and a window as thin as practicable. However, the window must simultaneously meet the requirement to keep sufficient vacuum, and therefore must limit gas permeation and remain mechanically robust against catastrophic failure under pressure. We report on the development of extremely thin composite polyethylene window technology that meets these goals. Two windows have been deployed for two full observing seasons on the BICEP3 and BA150 CMB telescopes at the South Pole. On BICEP3, the window has demonstrated a 6% improvement in detector sensitivity.
△ Less
Submitted 15 November, 2024;
originally announced November 2024.
-
Fabry-Pérot open resonant cavities for measuring the dielectric parameters of mm-wave optical materials
Authors:
Brodi D. Elwood,
Paul K. Grimes,
John Kovac,
Miranda Eiben,
Grant Meiners
Abstract:
As millimeter-wave cosmology experiments refine their optical chains, precisely characterizing their optical materials under cryogenic conditions becomes increasingly important. For instance, as the aperture sizes and bandwidths of millimeter-wave receivers increase, the design of antireflection coatings becomes progressively more constrained by an accurate measure of material optical properties i…
▽ More
As millimeter-wave cosmology experiments refine their optical chains, precisely characterizing their optical materials under cryogenic conditions becomes increasingly important. For instance, as the aperture sizes and bandwidths of millimeter-wave receivers increase, the design of antireflection coatings becomes progressively more constrained by an accurate measure of material optical properties in order to achieve forecasted performance. Likewise, understanding dielectric and scattering losses is relevant to photon noise modeling in presently-deploying receivers such as BICEP Array and especially to future experiments such as CMB-S4. Additionally, the design of refractive elements such as lenses necessitates an accurate measure of the refractive index. High quality factor Fabry-Pérot open resonant cavities provide an elegant means for measuring these optical properties. Employing a hemispherical resonator that is compatible with a quick-turnaround 4 Kelvin cryostat, we can measure the dielectric and scattering losses of low-loss materials at both ambient and cryogenic temperatures. We review the design, characterization, and metrological applications of quasioptical cavities commissioned for measuring the dielectric materials in the BICEP3 (95 GHz) and BICEP Array mid-frequency (150 GHz) optics. We also discuss the efforts to improve the finesse of said cavities, for better resolution of degenerate higher order modes, which can provide stronger constraints on cavity parameters and sample material thickness.
△ Less
Submitted 1 November, 2024;
originally announced November 2024.
-
Multi-layer anti-reflection coats using ePTFE membrane for mm-wavelength plastic optics
Authors:
Miranda Eiben,
Keara Carter,
Marion Dierickx,
Brodi Elwood,
Paul Grimes,
John Kovac,
Matthew Miller,
Matthew A. Petroff,
Annie Polish,
Clara Vergès
Abstract:
Future millimeter wavelength experiments aim to both increase aperture diameters and broaden bandwidths to increase the sensitivity of the receivers. These changes produce a challenging anti-reflection (AR) design problem for refracting and transmissive optics. The higher frequency plastic optics require consistently thin polymer coats across a wide area, while wider bandwidths require multilayer…
▽ More
Future millimeter wavelength experiments aim to both increase aperture diameters and broaden bandwidths to increase the sensitivity of the receivers. These changes produce a challenging anti-reflection (AR) design problem for refracting and transmissive optics. The higher frequency plastic optics require consistently thin polymer coats across a wide area, while wider bandwidths require multilayer designs. We present multilayer AR coats for plastic optics of the high frequency BICEP Array receiver (200-300 GHz) utilizing an expanded polytetrafluoroethylene (ePTFE) membrane, layered and compressively heat-bonded to itself. This process allows for a range of densities (from 0.3g/cc to 1g/cc) and thicknesses (>0.05mm) over a wide radius (33cm), opening the parameter space of potential AR coats in interesting directions. The layered ePTFE membrane has been combined with other polymer layers to produce band average reflections between 0.2% and 0.6% on high density polyethylene and a thin high modulus polyethylene window, respectively.
△ Less
Submitted 24 July, 2024;
originally announced July 2024.
-
Results and Limits of Time Division Multiplexing for the BICEP Array High Frequency Receivers
Authors:
S. Fatigoni,
P. A. R. Ade,
Z. Ahmed,
M. Amiri,
D. Barkats,
R. Basu Thakur,
C. A. Bischoff,
D. Beck,
J. J. Bock,
V. Buza,
J. Cheshire,
J. Connors,
J. Cornelison,
M. Crumrine,
A. J. Cukierman,
E. V. Denison,
M. I. Dierickx,
L. Duband,
M. Eiben,
J. P. Filippini,
A. Fortes,
M. Gao,
C. Giannakopoulos,
N. Goeckner-Wald,
D. C. Goldfinger
, et al. (62 additional authors not shown)
Abstract:
Time-Division Multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in multiplexing. Once fully populated, each of the two BICEP Array high frequency receivers, observing at 150GHz and 220/270GHz, will have 7776 TES detectors tiled on the…
▽ More
Time-Division Multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in multiplexing. Once fully populated, each of the two BICEP Array high frequency receivers, observing at 150GHz and 220/270GHz, will have 7776 TES detectors tiled on the focal plane. The constraints set by these two receivers required a redesign of the warm readout electronics. The new version of the standard Multi Channel Electronics, developed and built at the University of British Columbia, is presented here for the first time. BICEP Array operates Time Division Multiplexing readout technology to the limits of its capabilities in terms of multiplexing rate, noise and crosstalk, and applies them in rigorously demanding scientific application requiring extreme noise performance and systematic error control. Future experiments like CMB-S4 plan to use TES bolometers with Time Division/SQUID-based readout for an even larger number of detectors.
△ Less
Submitted 24 October, 2023; v1 submitted 16 October, 2023;
originally announced October 2023.
-
Conceptual Design of the Modular Detector and Readout System for the CMB-S4 survey experiment
Authors:
D. R. Barron,
Z. Ahmed,
J. Aguilar,
A. J. Anderson,
C. F. Baker,
P. S. Barry,
J. A. Beall,
A. N. Bender,
B. A. Benson,
R. W. Besuner,
T. W. Cecil,
C. L. Chang,
S. C. Chapman,
G. E. Chesmore,
G. Derylo,
W. B. Doriese,
S. M. Duff,
T. Elleflot,
J. P. Filippini,
B. Flaugher,
J. G. Gomez,
P. K. Grimes,
R. Gualtieri,
I. Gullett,
G. Haller
, et al. (25 additional authors not shown)
Abstract:
We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background Stage 4 (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60 percent of the sky. The fundamental…
▽ More
We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background Stage 4 (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60 percent of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over a wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4's science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 square meters of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing.
△ Less
Submitted 3 August, 2022;
originally announced August 2022.
-
Review of Radio Frequency Interference and Potential Impacts on the CMB-S4 Cosmic Microwave Background Survey
Authors:
Darcy R. Barron,
Amy N. Bender,
Ian E. Birdwell,
John E. Carlstrom,
Jacques Delabrouille,
Sam Guns,
John Kovac,
Charles R. Lawrence,
Scott Paine,
Nathan Whitehorn
Abstract:
CMB-S4 will map the cosmic microwave background to unprecedented precision, while simultaneously surveying the millimeter-wave time-domain sky, in order to advance our understanding of cosmology and the universe. CMB-S4 will observe from two sites, the South Pole and the Atacama Desert of Chile. A combination of small- and large-aperture telescopes with hundreds of thousands of polarization-sensit…
▽ More
CMB-S4 will map the cosmic microwave background to unprecedented precision, while simultaneously surveying the millimeter-wave time-domain sky, in order to advance our understanding of cosmology and the universe. CMB-S4 will observe from two sites, the South Pole and the Atacama Desert of Chile. A combination of small- and large-aperture telescopes with hundreds of thousands of polarization-sensitive detectors will observe in several frequency bands from 20-300 GHz, surveying more than 50 percent of the sky to arcminute resolution with unprecedented sensitivity. CMB-S4 seeks to make a dramatic leap in sensitivity while observing across a broad range of largely unprotected spectrum which is increasingly being utilized for terrestrial and satellite transmissions. Fundamental aspects of CMB instrument technology leave them vulnerable to radio frequency interference (RFI) across a wide range of frequencies, including frequencies outside of their observing bands. Ground-based CMB instruments achieve their extraordinary sensitivities by deploying large focal planes of superconducting bolometers to extremely dry, high-altitude sites, with large fractional bandwidths, wide fields of view, and years of integration time. Suitable observing sites have historically offered significant protection from RFI, both naturally through their extremely remote locations as well as through restrictions on local emissions. Since the coupling mechanisms are complex, safe levels or frequencies of emission that would not interfere with CMB measurements cannot always be determined through straightforward calculations. We discuss models of interference for various types of RFI relevant to CMB-S4, mitigation strategies, and the potential impacts on survey sensitivity.
△ Less
Submitted 2 August, 2022; v1 submitted 26 July, 2022;
originally announced July 2022.
-
Fluke 8588A and Keysight 3458A DMM Sampling Performance
Authors:
Rado Lapuh,
Jan Kucera,
Jakub Kovac,
Bostjan Voljc
Abstract:
This paper reports on an evaluation of the Fluke 8588A digital multimeter (DMM) sampling performance and comparison to Keysight 3458A DMM sampling performance. The design of 8588A type DMM shows both similarities and striking differences in design compared to 3458A type DMM. Apart from their specified sampling capabilities, measurements were performed to evaluate frequency response, noise performa…
▽ More
This paper reports on an evaluation of the Fluke 8588A digital multimeter (DMM) sampling performance and comparison to Keysight 3458A DMM sampling performance. The design of 8588A type DMM shows both similarities and striking differences in design compared to 3458A type DMM. Apart from their specified sampling capabilities, measurements were performed to evaluate frequency response, noise performance, including a 1 / f type noise and a timing jitter induced noise, as well as phase measurement performance. The given comprehensive report is crucial for careful application of DMMs in metrology tasks with optimal utilization of their performance.
△ Less
Submitted 23 May, 2022;
originally announced May 2022.
-
Receiver development for BICEP Array, a next-generation CMB polarimeter at the South Pole
Authors:
L. Moncelsi,
P. A. R. Ade,
Z. Ahmed,
M. Amiri,
D. Barkats,
R. Basu Thakur,
C. A. Bischoff,
J. J. Bock,
V. Buza,
J. Cheshire,
J. Connors,
J. Cornelison,
M. Crumrine,
A. Cukierman,
E. V. Denison,
M. Dierickx,
L. Duband,
M. Eiben,
S. Fatigoni,
J. P. Filippini,
N. Goeckner-Wald,
D. C. Goldfinger,
J. Grayson,
P. Grimes,
G. Hall
, et al. (50 additional authors not shown)
Abstract:
A detection of curl-type ($B$-mode) polarization of the primary CMB would be direct evidence for the inflationary paradigm of the origin of the Universe. The BICEP/Keck Array (BK) program targets the degree angular scales, where the power from primordial $B$-mode polarization is expected to peak, with ever-increasing sensitivity and has published the most stringent constraints on inflation to date…
▽ More
A detection of curl-type ($B$-mode) polarization of the primary CMB would be direct evidence for the inflationary paradigm of the origin of the Universe. The BICEP/Keck Array (BK) program targets the degree angular scales, where the power from primordial $B$-mode polarization is expected to peak, with ever-increasing sensitivity and has published the most stringent constraints on inflation to date. BICEP Array (BA) is the Stage-3 instrument of the BK program and will comprise four BICEP3-class receivers observing at 30/40, 95, 150 and 220/270 GHz with a combined 32,000+ detectors; such wide frequency coverage is necessary for control of the Galactic foregrounds, which also produce degree-scale $B$-mode signal. The 30/40 GHz receiver is designed to constrain the synchrotron foreground and has begun observing at the South Pole in early 2020. By the end of a 3-year observing campaign, the full BICEP Array instrument is projected to reach $σ_r$ between 0.002 and 0.004, depending on foreground complexity and degree of removal of $B$-modes due to gravitational lensing (delensing). This paper presents an overview of the design, measured on-sky performance and calibration of the first BA receiver. We also give a preview of the added complexity in the time-domain multiplexed readout of the 7,776-detector 150 GHz receiver.
△ Less
Submitted 7 December, 2020;
originally announced December 2020.
-
Characterizing the Sensitivity of 40 GHz TES Bolometers for BICEP Array
Authors:
C. Zhang,
P. A. R. Ade,
Z. Ahmed,
M. Amiri,
D. Barkats,
R. Basu Thakur,
C. A. Bischoff,
J. J. Bock,
H. Boenish,
E. Bullock,
V. Buza,
J. Cheshire,
J. Connors,
J. Cornelison,
M. Crumrine,
A. Cukierman,
M. Dierickx,
L. Duband,
S. Fatigoni,
J. P. Filippini,
G. Hall,
M. Halpern,
S. Harrison,
S. Henderson,
S. R. Hildebrandt
, et al. (44 additional authors not shown)
Abstract:
The BICEP/Keck (BK) experiment aims to detect the imprint of primordial gravitational waves in the Cosmic Microwave Background polarization, which would be direct evidence of the inflation theory. While the tensor-to-scalar ratio has been constrained to be r_0.05 < 0.06 at 95% c.l., further improvements on this upper limit are hindered by polarized Galactic foreground emissions and removal of grav…
▽ More
The BICEP/Keck (BK) experiment aims to detect the imprint of primordial gravitational waves in the Cosmic Microwave Background polarization, which would be direct evidence of the inflation theory. While the tensor-to-scalar ratio has been constrained to be r_0.05 < 0.06 at 95% c.l., further improvements on this upper limit are hindered by polarized Galactic foreground emissions and removal of gravitational lensing polarization. The 30/40 GHz receiver of the BICEP Array (BA) will deploy at the end of 2019 and will constrain the synchrotron foreground with unprecedented accuracy within the BK sky patch. We will show the design of the 30/40 GHz detectors and test results summarizing its performance. The low optical and atmospheric loading at these frequencies requires our TES detectors to have low saturation power in order to be photon-noise dominated. To realize the low thermal conductivity required from a 250 mK base temperature, we developed new bolometer leg designs. We will present the relevant measured detector parameters: G, Tc, Rn, Psat , and spectral bands, and noise spectra. We achieved a per bolometer NEP including all noise components of 2.07E-17 W/sqrt(Hz), including an anticipated photon noise level 1.54E-17 W/sqrt(Hz).
△ Less
Submitted 12 February, 2020;
originally announced February 2020.
-
Coupling loss at the end connections of REBCO stacks: 2D modelling and measurement
Authors:
Shuo Li,
Enric Pardo,
Jan Kovac
Abstract:
In high power density superconducting motors, superconducting tapes are usually stacked and connected together at terminals to improve the current capacity. When a parallel sinusoidal magnetic field is applied on this partially coupled stack, the coupling current is induced and causes additional coupling loss. Usually 3D modeling is needed to calculate the coupling loss but it takes too much compu…
▽ More
In high power density superconducting motors, superconducting tapes are usually stacked and connected together at terminals to improve the current capacity. When a parallel sinusoidal magnetic field is applied on this partially coupled stack, the coupling current is induced and causes additional coupling loss. Usually 3D modeling is needed to calculate the coupling loss but it takes too much computing resource and time. In this paper, a numerical 2D modeling by minimum electromagnetic entropy production (MEMEP) method is developed to speed up the calculation. The presented MEMEP model shows good accuracy and the capability to take the realistic resistance between tapes into account for coupling loss calculation with a high number of mesh element, which agrees to measurements.Thanks to the model, a systemic study of coupling loss on amplitude-dependence, frequency-dependence, resistance-dependence, and length-dependence, is presented and discussed. The results reveal the features of coupling loss which is very helpful devices with multi-tape conductors, such as the stator or rotor windings of motors.
△ Less
Submitted 9 January, 2020;
originally announced January 2020.
-
Broadband, millimeter-wave antireflection coatings for large-format, cryogenic aluminum oxide optics
Authors:
A. Nadolski,
J. D. Vieira,
J. A. Sobrin,
A. M. Kofman,
P. A. R. Ade,
Z. Ahmed,
A. J. Anderson,
J. S. Avva,
R. Basu Thakur,
A. N. Bender,
B. A. Benson,
L. Bryant,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
J. R. Cheshire IV,
G. E. Chesmore,
J. F. Cliche,
A. Cukierman,
T. de Haan,
M. Dierickx,
J. Ding,
D. Dutcher,
W. Everett
, et al. (64 additional authors not shown)
Abstract:
We present two prescriptions for broadband (~77 - 252 GHz), millimeter-wave antireflection coatings for cryogenic, sintered polycrystalline aluminum oxide optics: one for large-format (700 mm diameter) planar and plano-convex elements, the other for densely packed arrays of quasi-optical elements, in our case 5 mm diameter half-spheres (called "lenslets"). The coatings comprise three layers of com…
▽ More
We present two prescriptions for broadband (~77 - 252 GHz), millimeter-wave antireflection coatings for cryogenic, sintered polycrystalline aluminum oxide optics: one for large-format (700 mm diameter) planar and plano-convex elements, the other for densely packed arrays of quasi-optical elements, in our case 5 mm diameter half-spheres (called "lenslets"). The coatings comprise three layers of commercially-available, polytetrafluoroethylene-based, dielectric sheet material. The lenslet coating is molded to fit the 150 mm diameter arrays directly while the large-diameter lenses are coated using a tiled approach. We review the fabrication processes for both prescriptions then discuss laboratory measurements of their transmittance and reflectance. In addition, we present the inferred refractive indices and loss tangents for the coating materials and the aluminum oxide substrate. We find that at 150 GHz and 300 K the large-format coating sample achieves (97 +/- 2)% transmittance and the lenslet coating sample achieves (94 +/- 3)% transmittance.
△ Less
Submitted 2 March, 2020; v1 submitted 6 December, 2019;
originally announced December 2019.